Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where João Loures Salinet is active.

Publication


Featured researches published by João Loures Salinet.


Journal of Cardiovascular Electrophysiology | 2014

Distinctive Patterns of Dominant Frequency Trajectory Behavior in Drug-Refractory Persistent Atrial Fibrillation: Preliminary Characterization of Spatiotemporal Instability

João Loures Salinet; Jiun H. Tuan; A J Sandilands; Peter J. Stafford; Fernando S. Schlindwein; G. André Ng

The role of substrates in the maintenance of persistent atrial fibrillation (persAF) remains poorly understood. The use of dominant frequency (DF) mapping to guide catheter ablation has been proposed as a potential strategy, but the characteristics of high DF sites have not been extensively studied. This study aimed to assess the DF spatiotemporal stability using high density noncontact mapping (NCM) in persAF.


Computing in Science and Engineering | 2013

Visualizing intracardiac atrial fibrillation electrograms using spectral analysis

João Loures Salinet; Guilherme N. Oliveira; Frederique Jos Vanheusden; João Luiz Dihl Comba; G.A. Ng; Fernando S. Schlindwein

Atrial fibrillation is the most common cardiac arrhythmia, and it is associated with increased risk of stroke, heart failure, and mortality. This work describes spectral analysis techniques that are being used in conjunction with visualization algorithms to help guide catheter ablation procedures that aim at treating patients with arrhythmia.


Computer Methods and Programs in Biomedicine | 2017

An interactive platform to guide catheter ablation in human persistent atrial fibrillation using dominant frequency, organization and phase mapping

Xin Li; João Loures Salinet; Tiago P. Almeida; Frederique Jos Vanheusden; Gavin S. Chu; G. André Ng; Fernando S. Schlindwein

BACKGROUND AND OBJECTIVE Optimal targets for persistent atrial fibrillation (persAF) ablation are still debated. Atrial regions hosting high dominant frequency (HDF) are believed to participate in the initiation and maintenance of persAF and hence are potential targets for ablation, while rotor ablation has shown promising initial results. Currently, no commercially available system offers the capability to automatically identify both these phenomena. This paper describes an integrated 3D software platform combining the mapping of both frequency spectrum and phase from atrial electrograms (AEGs) to help guide persAF ablation in clinical cardiac electrophysiological studies. METHODS 30s of 2048 non-contact AEGs (EnSite Array, St. Jude Medical) were collected and analyzed per patient. After QRST removal, the AEGs were divided into 4s windows with a 50% overlap. Fast Fourier transform was used for DF identification. HDF areas were identified as the maximum DF to 0.25Hz below that, and their centers of gravity (CGs) were used to track their spatiotemporal movement. Spectral organization measurements were estimated. Hilbert transform was used to calculate instantaneous phase. RESULTS The system was successfully used to guide catheter ablation for 10 persAF patients. The mean processing time was 10.4 ± 1.5min, which is adequate comparing to the normal electrophysiological (EP) procedure time (120∼180min). CONCLUSIONS A customized software platform capable of measuring different forms of spatiotemporal AEG analysis was implemented and used in clinical environment to guide persAF ablation. The modular nature of the platform will help electrophysiological studies in understanding of the underlying AF mechanisms.


computing in cardiology conference | 2015

Investigation on recurrent high dominant frequency spatiotemporal patterns during persistent atrial fibrillation

Xin Li; Gavin S. Chu; Tiago P. Almeida; Frederique Jos Vanheusden; Nawshin Dastagir; João Loures Salinet; Peter J. Stafford; G. André Ng; Fernando S. Schlindwein

Atrial regions hosting dominant frequency (DF) may represent potential drivers of persistent atrial fibrillation (persAF). Previous work showed that DF can exhibit cyclic behaviour. This study aims to better understand the spatiotemporal behaviours of persAF over longer time periods. 10 patients undergoing persAF ablation targeted at DF were included. Left atrial (LA) non-contact virtual electrograms (VEGMs, Ensite Array, St Jude Medical) were collected for up to 5 min pre-/post- ablation. DF was identified as the peak from 4-10 Hz, in 4 s windows (50 % overlap). High DF (HDF) map was created and automated pattern recognition algorithm was applied to look for recurring HDF spatial patterns within each patient. Recurring HDF patterns were found in all patients. Patients who changed rhythm to atrial flutter after ablation demonstrated single dominant pattern (DP) among the recorded time period, which might consistent with the higher level of regularity during flutter. Ablation regularized AF as demonstrated by increased DP recurrence after ablation. The time interval (median [IQR]) of DP recurrence for the patients still in atrial fibrillation(AF) after ablation (7 patients) decreased from 21.1 s [11.8~49.7 s] to 15.7s [6.5~18.2 s]. The proposed method quantifies the spatiotemporal regularity of HDF DPs over long time periods and may offer a more comprehensive dynamic overview of persAF behaviour and the impact of ablation.


computing in cardiology conference | 2015

Drifting rotor prevalence is associated with dominant frequency reduction after persistent atrial fibrillation ablation

João Loures Salinet; Maria S. Guillem; Tiago P. Almeida; Xin Li; Gustavo Goroso; Gavin S. Chu; G. André Ng; Fernando S. Schlindwein

Identification and targeting of arrhythmogenic atrial regions remains an evident challenge in persistent atrial fibrillation patients. Frequency and phase analysis have shown their usefulness for better understanding the arrhythmia. This study aimed to investigate the spatio-temporal association between dominant frequency (DF) and re-entrant phase activation areas. For this, eight persistent AF patients were enrolled and 2048 left atrial AF electrograms (AEG) were acquired from each for up to 15 seconds following ventricular far-field cancellation. DF and phase singularity (PS) points were automatically identified and tracked over consecutive frames for spatio-temporal analysis. As result, simultaneous not spatio-temporally stable PS points were identified drifting throughout the left atrium. After pulmonary vein isolation PS incidence reduced (90.8±59.8 vs. 23.8±31.6, p<;0.05), concomitantly, DF decreased (DFmax from 7.3±0.4 Hz to 7.1±0.8 Hz, p=0.26 and DFmin from 5.1±1.2 Hz to 4.2±1.1 Hz, p<;0.05). Higher concentrations of PS areas seem to have a certain degree of co-localisation with HDF regions. Both frequency and phase analyses seem to have a role in identifying atrial regions that might be perpetuating persistent AF. Concatenated DF/PS mapping may contribute as an auxiliary tool for AF ablation.


computing in cardiology conference | 2015

A novel method for automatic standardization of digital electrocardiographs

Eduardo B Freitas; João Loures Salinet; Tiago P. Almeida; Henrique Jq Oliveira

It is crucial to assure the quality of ECG recordings to support correct clinical interpretation. This research aimed at developing an automated standardization method to gauge digital electrocardiography (EC) devices. The proposed microprocessed gauge equipment (MGE) is divided into digital and analogic circuits, and embedded software to control them. Conditioned reference signals (CRS) from Physionet Bank were embedded in the MGE to simulate cardiac activity. The outputs from the MGE (or EC) are then compared with the CRS. All circuits of the MGE are gauged at the self-check mode. CRS are sent to the EC when set at the EC check mode. A commercial EC equipment was used in the MGE validation (IEC60601-2-51:2005), assessed with the statistical R2 correlation analysis and Kolmogorov-Smirnov (KS). At the MGE self-test, temperature and humidity were changed (R2≥0.99 as designed). The KS test (P<;0.01) resulted in D=0.012 for amplitude accuracy, 0.0028 for timing accuracy and 0.021 for signal stability against noise influence. All KS values were lower than their respective critical values according to the default standard (5%). Finally, visual inspection between EC signals and CRS on printed graph paper at a standard scale certifies the EC reliability.


computing in cardiology conference | 2015

Unifying automated fractionated atrial electrogram classification using electroanatomical mapping systems in persistent atrial fibrillation studies

Tiago P. Almeida; Gavin S. Chu; João Loures Salinet; Frederique Jos Vanheusden; Xin Li; Jiun H. Tuan; Peter J. Stafford; G. André Ng; Fernando S. Schlindwein

Ablation targeting complex fractionated atrial electrograms (CFAE) for treating persistent atrial fibrillation (persAF) has shown conflicting results. Differences in automated algorithms embedded in NavX (St Jude Medical) and CARTO (Biosense Webster) could influence CFAE target identification for ablation, potentially affecting ablation outcomes. To evaluate this effect, automated CFAE classification performed by NavX and CARTO on the same bipolar electrograms from 18 persAF patients undergoing ablation was compared. Using the default thresholds, NavX classified 69±5% of the electrograms as CFAEs, while CARTO detected 35±5%% (Cohens kappa κ≈0.3, P<;0.0001). Both primary and complementary metrics for each system were optimized to balance CFAE detection for both systems. Using revised thresholds found from receiver operating characteristic curves, NavX classified 45±4%, while CARTO detected 42±5% (κ≈0.5, P<;0.0001). Our work takes a first step towards the optimization of CFAE detection between NavX and CARTO by providing revised thresholds to reduce differences in CFAE classification. This would facilitate direct comparisons of persAF CFAE-guided ablation outcome guided by NavX or CARTO.


Medical & Biological Engineering & Computing | 2013

Analysis of QRS-T subtraction in unipolar atrial fibrillation electrograms

João Loures Salinet; J. P. V. Madeiro; Paulo César Cortez; Peter J. Stafford; G. André Ng; Fernando S. Schlindwein


Medical & Biological Engineering & Computing | 2016

Minimizing discordances in automated classification of fractionated electrograms in human persistent atrial fibrillation.

Tiago P. Almeida; Gavin S. Chu; João Loures Salinet; Frederique Jos Vanheusden; Xin Li; Jiun H. Tuan; Peter J. Stafford; G. André Ng; Fernando S. Schlindwein


Medical & Biological Engineering & Computing | 2011

QRS subtraction for atrial electrograms: flat, linear and spline interpolations

A. Ahmad; João Loures Salinet; P. Brown; J. H. Tuan; Peter J. Stafford; G. André Ng; Fernando S. Schlindwein

Collaboration


Dive into the João Loures Salinet's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

G. André Ng

University of Leicester

View shared research outputs
Top Co-Authors

Avatar

Peter J. Stafford

University Hospitals of Leicester NHS Trust

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gavin S. Chu

University of Leicester

View shared research outputs
Top Co-Authors

Avatar

Xin Li

University of Leicester

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jiun H. Tuan

University Hospitals of Leicester NHS Trust

View shared research outputs
Top Co-Authors

Avatar

G.A. Ng

University of Leicester

View shared research outputs
Researchain Logo
Decentralizing Knowledge