Jodi Blake Courtney
Duke University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Jodi Blake Courtney.
Therapeutic Drug Monitoring | 2009
Jan H. Beumer; Michelle Boisdron-Celle; William Clarke; Jodi Blake Courtney; Merrill J. Egorin; Erick Gamelin; Rebecca L. Harney; Catherine A. Hammett-Stabler; Sandy Lepp; Yunying Li; Gregory D. Lundell; Gwen McMillin; Gérard Milano; Salvatore J. Salamone
Bishop, DC, Smith, RJ, Smith, MF, and Rigby, HE. Effect of plyometric training on swimming block start performance in adolescents. J Strength Cond Res 23(7): 2137-2143, 2009-This study aimed to identify the effect of plyometric training (PT), when added to habitual training (HT) regimes, on swim start performance. After the completion of a baseline competitive swim start, 22 adolescent swimmers were randomly assigned to either a PT (n = 11, age: 13.1 ± 1.4 yr, mass: 50.6 ± 12.3 kg, stature: 162.9 ± 11.9 cm) or an HT group (n = 11, age: 12.6 ± 1.9 yr, mass: 43.3 ± 11.6 kg, stature: 157.6 ± 11.9 cm). Over an 8-week preseason period, the HT group continued with their normal training program, whereas the PT group added 2 additional 1-hour plyometric-specific sessions, incorporating prescribed exercises relating to the swimming block start (SBS). After completion of the training intervention, post-training swim start performance was reassessed. For both baseline and post-trials, swim performance was recorded using videography (50Hz Canon MVX460) in the sagital plane of motion. Through the use of Silicon Coach Pro analysis package, data revealed significantly greater change between baseline and post-trials for PT when compared with the HT group for swim performance time to 5.5 m (−0.59 s vs. −0.21 s; p < 0.01) and velocity of take-off to contact (0.19 ms−1 vs. −0.07 ms−1; p < 0.01). Considering the practical importance of a successful swim start to overall performance outcome, the current study has found that inclusion of suitable and safely implemented PT to adolescent performers, in addition to HT routines, can have a positive impact on swim start performance.BACKGROUND 5-Fluorouracil (5-FU) is the most widely used chemotherapy drug, primarily against gastrointestinal, head and neck, and breast cancers. 5-FU has large pharmacokinetic variability resulting in unexpected toxicity or ineffective treatment. Therapeutic drug management of 5-FU minimizes toxicity and improves outcome. A nanoparticle-based immunoassay was developed to provide oncologists with a rapid, cost-effective tool for determining 5-FU plasma concentrations. METHODS Monoclonal antibodies, bound to nanoparticles, were used to develop an immunoassay for the Olympus AU400. Assay precision, linearity, calibration stability, and limit of detection were run at multiple centers; interference, cross-reactivity, lower limit of quantitation and recovery at 1 center. Clinical samples collected from 4 cancer centers were analyzed for 5-FU concentrations by liquid chromatography-tandem mass spectrometry and compared with the immunoassay results. RESULTS With calibrators from 0 to 1800 ng/mL 5-FU and autodilution, concentrations up to 9000 ng/mL could be determined. Time to first result was 10 minutes, and 400 samples per hour could be quantitated from a standard curve stored for >30 days. Imprecision across all laboratories was <5%, and the assay was linear upon dilution over the entire range. Cross-reactivities for dihydro-5-FU, uracil, capecitabine, and tegafur were <1%, 9.9%, 0.05%, and 0.23%, respectively. The limit of detection was 52 ng/mL with a lower limit of quantitation of 86 ng/mL. Assay results of clinical samples (93-1774 ng/mL) correlated with liquid chromatography-tandem mass spectrometry results: (R = 0.9860, slope 1.035, intercept 10.87 ng/mL). CONCLUSIONS This novel immunoassay is suitable for quantitating 5-FU plasma concentrations with advantages of speed, small sample size, minimal sample pretreatment, and application on automated instrumentation. These advantages enable efficient therapeutic drug management of 5-FU in clinical practice.
Therapeutic Drug Monitoring | 2009
Jodi Blake Courtney; Rebecca L. Harney; Yunying Li; Gregory D. Lundell; Gwendolyn A. McMillin; Geeta Agarwal; JoEtta M. Juenke; Anu Mathew; Rita Gonzalez-Espinoza; Martin Fleisher; Salvatore J. Salamone
High-dose busulfan is an important component of many bone marrow transplantation-preparative regimens. High busulfan plasma levels have been shown to increase the chance of venoocclusive disease and low levels are associated with recurrence of disease or graft rejection. Currently, busulfan levels are monitored by physical methods that are expensive and time consuming, resulting in relatively low overall use of busulfan testing for dose adjustment. Novel highly selective antibodies for busulfan have been generated and a microtiter plate immunoassay capable of quantifying busulfan levels in plasma has been developed. The assay was configured using a busulfan-horseradish peroxidase (HRP) conjugate as the reporter group and busulfan monoclonal antibodies. The assay requires 30 μL of plasma with no sample preparation. The immunoassay has a standard curve based on busulfan with a range of 75-2000 ng/mL. The time to first result is 30 minutes with up to 40 patient samples in duplicate; multiple plates can be run at once. The coefficient of variation (CV) on signal is <5% for an entire plate, and the 95% confidence interval for negative samples (n = 78) is below the lowest calibrator of 75 ng/mL. Cross-reactivity with the major inactive metabolites (tetrahydrothiophene, tetramethyl sulfone, and tetrahydrothiophene-3-ol-1,1-dioxide) was <0.1%. Results generated with clinical samples (n = 35 and n = 70) correlate well to gas chromatography-mass spectrometry (R = 0.976 and 0.985, respectively) with a slope of 1.05 ± 0.05. This immunoassay method is suitable for determining levels of busulfan in human plasma. It offers the advantages of using a smaller sample size, does not require sample preparation, and is less labor intensive than other methods. The ability to make 240 determinations per hour enables effective and timely routine monitoring of busulfan levels in clinical practice.
Therapeutic Drug Monitoring | 2013
Daniel J. Cline; Hongxia Zhang; Gregory D. Lundell; Rebecca L. Harney; Hadia K. Riaz; Justin Jarrah; Yunying Li; Makoto Miyazaki; Jodi Blake Courtney; Irina Baburina; Salvatore J. Salamone
Background: Docetaxel (Taxotere) (DTX) is a widely used chemotherapy agent used in many regimens for the treatment of solid tumors, for example breast cancer, non–small cell lung cancer, gastric, prostate, and head and neck cancers. This drug meets the criteria for therapeutic dose management, in that it is associated with high pharmacokinetic variability and dose-limiting toxicity; it has a narrow therapeutic window, and there is a significant pharmacokinetic–pharmacodynamic relationship. Measures of exposure and area under the time–concentration curve have been associated with both toxicity and outcomes, making therapeutic dose management for this drug an unmet clinical need. The current methodologies for measuring DTX are based on physical methods, making the analysis less available and costly. An automated immunoassay has been developed to provide greater access to DTX dose management. Methods: A DTX immunoassay (MyDocetaxel) has been developed using a generic nanoparticle turbidimetric method that can be used on a wide variety of automated clinical chemistry analyzers including the Beckman Coulter AU400 and AU640 instruments, which were used in this study. The assay is based on a competitive assay format using a selective DTX monoclonal antibody. Clinical Laboratory Standards Institute protocols for establishing manufacturers claims were used to verify performance. Testing at 3 clinical laboratories was undertaken using the same protocols for laboratory validation of precision, accuracy, and linearity. Method comparison (n = 89) was done using samples collected from patients on DTX therapy. The comparative method was LC–MS/MS validated according to Food and Drug Administration guidance on bioanalytical methods. Institutional review board approval was obtained for prospective collection of samples from patients on DTX therapy. Results: The assay on the AU400 uses 2 &mgr;L of sample, provides the first result in 9.0 minutes and can generate 400 determinations per hour. Internal studies established a lower limit of detection ⩽25 ng/mL and a lower limit of quantitation ⩽30 ng/mL. Additional studies demonstrated no interference from coadministered drugs, major metabolites, or related compounds. Linearity from 50 to 1000 ng/mL was validated. Method comparisons between laboratories and to the physical method gave slopes: 1 ± 0.5, intercepts: < 2.0 ng/mL, R > 0.99, with the range of DTX concentrations measured by the assay 31–9754 ng/mL, with a mean of 689 ng/mL. In all 3 laboratories, the coefficient of variation percentage for repeatability ranged from 0.8% to 6.2% and the within-laboratory precision ranged from 1.4% to 10.1%. Conclusions: This immunoassay is suitable for quantifying DTX in plasma with advantages of small sample size, no sample pretreatment, and the ability to be applied to a wide range of clinical analyzers. With the validation of this method, the application of DTX testing in clinical practice may gain wider acceptance for individualizing patient DTX dosing.
Therapeutic Drug Monitoring | 2013
Daniel J. Cline; Hongxia Zhang; Gregory D. Lundell; Rebecca L. Harney; Hadia K. Riaz; Justin Jarrah; Yunying Li; Makoto Miyazaki; Jodi Blake Courtney; Irina Baburina; Salvatore J. Salamone
Background: Paclitaxel (PTX; Taxol, Abraxane) is used in many regimens for breast cancer, non–small cell lung cancer (NSCLC), and ovarian cancer. Multiple studies have demonstrated that PTX exhibits a greater than 10-fold interpatient variability of clearance rates when patients are dosed according to body surface area (BSA). Pharmacokinetic and pharmacodynamic relationships have been elucidated from BSA-based dosing. PTX is a candidate for dose management, and studies have shown that therapeutic dose management (TDM) is feasible and may provide improved outcomes for patients undergoing treatment. Methods: A PTX immunoassay (MyPaclitaxel) has been developed, which employs a novel PTX monoclonal antibody in a nanoparticle-based turbidimetric assay in a competitive format. Precision, accuracy, and linearity were evaluated by Clinical Laboratory Standards Institute protocols at 3 laboratories on the Olympus AU400 analyzer. Method comparison was done versus a validated high-performance liquid chromatography–tandem mass spectroscopy method using samples (n = 119) collected from patients on PTX therapy. Results: The assay requires 8 &mgr;L of plasma sample and can produce 400 determinations per hour. The response curve is based on a 6-point nonlinear curve fit and has a range of 0-320 ng/mL, extended to 3200 ng/mL with 10-fold autodilution. Three controls and 4 patient pools were used in precision studies. For all samples across 3 sites, repeatability coefficient of variation percentages ranged 0.9%-4.9%, and within-laboratory coefficient of variation percentages were 1.0%-4.2% with standard curve stability up to 24 days. Linearity was demonstrated over the linear range. Lower limits of detection and quantitation were 11 and 19 ng/mL, respectively. Method comparison results were analyzed by Deming regression, demonstrating a slope = 1.002 and intercept = −3.029 and an R = 0.996. The PTX samples ranged from 24 to 3164 ng/mL with a mean of 745 ng/mL. Conclusions: The analytical performance of an automated immunoassay for PTX has been validated and may serve as a useful tool for TDM of this drug.
Therapeutic Drug Monitoring | 2015
Jan H. Beumer; Daniel Kozo; Rebecca L. Harney; Caitlin N. Baldasano; Justin Jarrah; Susan M. Christner; Robert A. Parise; Irina Baburina; Jodi Blake Courtney; Salvatore J. Salamone
Background: Imatinib pharmacokinetic variability and the relationship of trough concentrations with clinical outcomes have been extensively reported. Although physical methods to quantitate imatinib exist, they are not widely available for routine use. An automated homogenous immunoassay for imatinib has been developed, facilitating routine imatinib testing. Methods: Imatinib-selective monoclonal antibodies, without substantial cross-reactivity to the N-desmethyl metabolite or N-desmethyl conjugates, were produced. The antibodies were conjugated to 200 nm particles to develop immunoassay reagents on the Beckman Coulter AU480 analyzer. These reagents were analytically validated using Clinical Laboratory Standards Institute protocols. Method comparison to liquid chromatography tandem mass spectrometry (LC-MS/MS) was conducted using 77 plasma samples collected from subjects receiving imatinib. Results: The assay requires 4 µL of sample without pretreatment. The nonlinear calibration curve ranges from 0 to 3000 ng/mL. With automated sample dilution, concentrations of up to 9000 ng/mL can be quantitated. The AU480 produces the first result in 10 minutes and up to 400 tests per hour. Repeatability ranged from 2.0% to 6.0% coefficient of variation, and within-laboratory reproducibility ranged from 2.9% to 7.4% coefficient of variation. Standard curve stability was 2 weeks and on-board reagent stability was 6 weeks. For clinical samples with imatinib concentrations from 438 to 2691 ng/mL, method comparison with LC-MS/MS gave a slope of 0.995 with a y-intercept of 24.3 and a correlation coefficient of 0.978. Conclusions: The immunoassay is suitable for quantitating imatinib in human plasma, demonstrating good correlation with a physical method. Testing for optimal imatinib exposure can now be performed on routine clinical analyzers.
Alzheimers & Dementia | 2014
Daniel Kozo; Salvatore J. Salamone; Irina Baburina; Kim Williams; Caitlin N. Baldasano; Jodi Blake Courtney; George Green; Holly Soares; Gary Feiss; Adam J. Simon
of the optical densities in ten repetitions of the standard curves was 5% for all standards. In the clinical part, at the cut off value 691 pg/mL, Ab 1-42 showed the sensitivity and the specificity of 69.3 %, and 88.9%, respectively, whereas at the cut off value 0.06, Ab 42/40 ratio showed even better sensitivity and specificity of 93.3%, and 100%, respectively. The area under the ROC curve for Ab 42/40 (0.974) was highly significantly larger compared to the AUC of the Ab 1-42 concentration ROC curve (0.827, p<0.0001). Conclusions: (a) the novel Ab1-40 and Ab1-42 ELISA assays characterize with very good analytical performance; (b) we reconfirm that the CSF Ab42/40 concentration ratio shows significantly better diagnostic performance compared to the CSF Ab1-42 concentration alone.
Alzheimers & Dementia | 2013
Adam J. Simon; Salvatore J. Salamone; William Clarke; George Green; Holly Soares; Leah Burns; Irina Baburina; Daniel Kozo; Jodi Blake Courtney; Paul Contestable; Shari Jackson; Patience Ajongwen
P2-072 PERFORMANCE OF PRELIMINARY CUT-POINTS FOR PROGRESSION FROM MILD COGNITIVE IMPAIRMENT TO DEMENTIA OF THE ALZHEIMER’S DISEASE TYPE USING FULLY AUTOMATED CHEMILUMINESCENT BETAAMYLOID 42 AND TAU ASSAYS Adam Simon, Salvatore Salamone, William Clarke, George Green, Holly Soares, Leah Burns, Irina Baburina, Daniel Kozo, Jodi Courtney, Paul Contestable, Shari Jackson, Patience Ajongwen, AJ Simon Enterprises LLC., Yardley, Pennsylvania, United States; Saladax Biomedical, Inc., Bethlehem, New Jersey, United States; Johns Hopkins University School of Medicine, Baltimore, Maryland, United States; Bristol Myers Squibb, Princeton, New Jersey, United States; Bristol Myers Squibb, Wallingford, New Jersey, United States; Bristol-Myers Squibb, Wallingford, New Jersey, United States; Saladax Biomedical, Bethlehem, Pennsylvania, United States; Ortho Clinical Diagnostics, Rochester, New York, United States; Ortho Clinical Diagnostics, Rochester, New York, United States. Contact e-mail: [email protected]
Alzheimers & Dementia | 2013
Adam J. Simon; Irina Baburina; William Clarke; George Green; Holly Soares; Salvatore J. Salamone; Daniel Kozo; Jodi Blake Courtney; Paul Contestable; Shari Jackson; Patience Ajongwen
P1-179 INITIAL EVALUATION OF FULLYAUTOMATED, CHEMILUMINESCENT BETA-AMYLOID 42 AND TAU ASSAYS Adam Simon, Irina Baburina, William Clarke, George Green, Holly Soares, Salvatore Salamone, Daniel Kozo, Jodi Courtney, Paul Contestable, Shari Jackson, Patience Ajongwen, A.J. Simon Enterprises Llc., Yardley, Pennsylvania, United States; Saladax Biomedical, Bethlehem, Pennsylvania, United States; Johns Hopkins University School of Medicine, Baltimore, Maryland, United States; Bristol Myers Squibb, Princeton, New Jersey, United States; Bristol Myers Squibb, Wallingford, New Jersey, United States; Saladax Biomedical, Inc., Bethlehem, Pennsylvania, United States; Ortho Clinical Diagnostics, Rochester, New York, United States; Ortho Clinical Diagnostics, Rochester, New York, United States. Contact e-mail: [email protected]
Alzheimers & Dementia | 2013
Irina Baburina; Paul Contestable; George Green; Holly Soares; Shari Jackson; Karen Ackles; Anne Tweedie; Daniel Kozo; Jodi Blake Courtney; Salvatore J. Salamone
Archive | 2006
Salvatore J. Salamone; Jodi Blake Courtney; Dennis Stocker