Joël Cugnoni
École Polytechnique Fédérale de Lausanne
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Joël Cugnoni.
Journal of Biomechanics | 2011
Marzio Bergomi; Joël Cugnoni; Matteo Galli; J. Botsis; Urs C. Belser; H. W. Anselm Wiskott
Harmonic tension-compression tests at 0.1, 0.5 and 1 Hz on hydrated bovine periodontal ligament (PDL) were numerically simulated. The process was modeled by finite elements (FE) within the framework of poromechanics, with the objective of isolating the contributions of the solid- and fluid phases. The solid matrix was modeled as a porous hyperelastic material (hyperfoam) through which the incompressible fluid filling the pores flowed in accordance with the Darcys law. The hydro-mechanical coupling between the porous solid matrix and the fluid phase circulating through it provided an apparent time-dependent response to the PDL, whose rate of deformation depended on the permeability of the porous solid with respect to the interstitial fluid. Since the PDL was subjected to significant deformations, finite strains were taken into account and an exponential dependence of PDL permeability on void ratio - and therefore on the deformation state - was assumed. PDL constitutive parameters were identified by fitting the simulated response to the experimental data for the tests at 1 Hz. The values thus obtained were then used to simulate the tests at 0.1 and 0.5 Hz. The results of the present simulation demonstrate that a porohyperelastic model with variable permeability is able to describe the two main aspects of the PDLs response: (1) the dependency on strain-rate-the saturated material can develop volumetric strains by only exchanging fluid and (2) the asymmetry between tension and compression, which is due to the effect of both the permeability and the elastic properties on deformation.
Journal of Electronic Materials | 2014
Milad Maleki; Joël Cugnoni; J. Botsis
Due to the high homologous temperature and fast cooling rates, the microstructures of SnAgCu (SAC) solders are in a meta-stable state in most applications, which is the cause of significant microstructural evolution and continuous variation in the mechanical behavior of the joints during service. The link between microstructures evolution and deformation behavior of Sn-4.0Ag-0.5Cu solder during isothermal ageing is investigated. The evolution of the microstructures in SAC solders are visualized at different scales in 3D by using a combination of synchrotron x-ray and focused ion beam/scanning electron microscopy tomography techniques at different states of ageing. The results show that, although the grain structure, morphology of dendrites, and overall volume fraction of intermetallics remain almost constant during ageing, considerable coarsening occurs in the Ag3Sn and Cu6Sn5 phases to lower the interfacial energy. The change in the morphometrics of sub-micron intermetallics is quantified by 3D statistical analyses and the kinetic of coarsening is discussed. The mechanical behavior of SAC solders is experimentally measured and shows a continuous reduction in the yield resistance of solder during ageing. For comparison, the mechanical properties and grain structure of β-tin are evaluated at different annealing conditions. Finally, the strengthening effect due to the intermetallics at different ageing states is evaluated by comparing the deformation behaviors of SAC solder and β-tin with similar grain size and composition. The relationship between the morphology and the strengthening effect due to intermetallics particles is discussed and the causes for the strength degradation in SAC solder during ageing are identified.
Computer Methods in Biomechanics and Biomedical Engineering | 2014
Marco Piccinini; Joël Cugnoni; John Botsis; Giovanna Zacchetti; Patrick Ammann; Anselm Wiskott
The authors propose a protocol to derive finite element (FE) models from micro computer tomography scans of implanted rat bone. A semi-automatic procedure allows segmenting the images using specimen-specific bone mineral density (BMD) thresholds. An open-source FE model generator processes the segmented images to a quality tetrahedral mesh. The material properties assigned to each element are integrated from the BMD field. Piecewise, threshold-dependent density–elasticity relationships are implemented to limit the effects of metal artefacts. A detailed sensitivity study highlights the coherence of the generated models and quantifies the influence of the modelling parameters on the results. Two applications of the protocol are proposed. The stiffness of bare and implanted rat tibiae specimens is predicted by simulating three-point bending and inter-implant displacement, respectively. Results are compared with experimental tests. The mean value and the variability between the specimens are well captured in both tests.
Medical Engineering & Physics | 2016
Marco Piccinini; Joël Cugnoni; John Botsis; Patrick Ammann; Anselm Wiskott
Long term durability of osseointegrated implants depends on bone adaptation to stress and strain occurring in proximity of the prosthesis. Mechanical overloading, as well as disuse, may reduce the stability of implants by provoking bone resorption. However, an appropriate mechanical environment can improve integration. Several studies have focused on the definition of numerical methods to predict bone peri-implant adaptation to the mechanical environment. Existing adaptation models differ notably in the type of mechanical variable adopted as stimulus but also in the bounds and shape of the adaptation rate equation. However, a general comparison of the different approaches on a common benchmark case is still missing and general guidelines to determine physically sound parameters still need to be developed. This current work addresses these themes in two steps. Firstly, the histograms of effective stress, strain and strain energy density are compared for rat tibiae in physiological (homeostatic) conditions. According to the Mechanostat, the ideal stimulus should present a clearly defined, position and tissue invariant lazy zone in homeostatic conditions. Our results highlight that only the octahedral shear strain presents this characteristic and can thus be considered the optimal choice for implementation of a continuum level bone adaptation model. Secondly, critical modeling parameters such as lazy zone bounds, type of rate equation and bone overloading response are classified depending on their influence on the numerical predictions of bone adaptation. Guidelines are proposed to establish the dominant model parameters based on experimental and simulated data.
Holzforschung | 2013
Martin Rhême; John Botsis; Joël Cugnoni; Parviz Navi
Abstract Friction welding is a joining technique for wood materials. The positive aspects of this technique are the speed of processing and the absence of chemical or mechanical agents, but the welded joints are not water resistant. To understand better the effect of moisture on the fracture behavior of welded joints, their fracture characteristics have been investigated. The double cantilever beam specimens were tested, which permit to compute the mode I energy release rate of a welded joint. The results confirm the negative effect of moisture on the fracture properties of the joint. The data concerning the maximal tensile strength of the joining material were collected by uniaxial tests and implemented in a finite element model to establish a cohesive law, which describes the behavior of welded pieces in terms of moisture content.
Smart Materials and Structures | 2015
Enrique Guzmán; Joël Cugnoni; Thomas Gmür
Aiming to reduce costs, polyvinylidene difluoride (PVDF) film patches are an emerging alternative to more classic piezoelectric technologies, like ceramic patches, as transducers to measure local deformation in many structural applications. This choice is supported by advantages such as the low weight and mechanical flexibility of PVDF, making this polymer suitable for embedding inside full scale polymer based composite structures. Piezoelectric transducer patches can be used as actuators to dynamically excite full-scale composite structures, and as sensors to measure the strain. The main objective of this paper is to verify that the PVDF transducers can provide exploitable signals in the context of structural health monitoring. In order to do so, two aspects of the design of transducer network are investigated: the optimization of the sensor network, for which the effective independence method is proposed, and the use of operational modal analysis (OMA), since it is a simple method to extract the natural frequencies of a structure from a time series. The results of the analysis are compared to a reference set issued from experimental modal analysis (EMA), a simple, well-known, classic method, which is carried out using accelerometers and an impact hammer. By statistical means, it is shown that there is no significant difference between the two methods, and an optimized PVDF transducer network combined with OMA can perform the dynamic analysis of a structure as well as a classic EMA setup would do. This leads the way to the use of low-cost PVDF embedded transducer networks for robust composite material characterization.
Journal of Biomechanics | 2014
Marco Piccinini; Joël Cugnoni; John Botsis; Patrick Ammann; Anselm Wiskott
Implanted rat bones play a key role in studies involving fracture healing, bone diseases or drugs delivery among other themes. In most of these studies the implants integration also depends on the animal daily activity and musculoskeletal loads, which affect the implants mechanical environment. However, the tissue adaption to the physiological loads is often filtered through control groups or not inspected. This work aims to investigate experimentally and numerically the effects of the daily activity on the integration of implants inserted in the rat tibia, and to establish a physiological loading condition to analyse the peri-implant bone stresses during gait. Two titanium implants, single and double cortex crossing, are inserted in the rat tibia. The animals are caged under standard conditions and divided in three groups undergoing progressive integration periods. The results highlight a time-dependent increase of bone samples with significant cortical bone loss. The phenomenon is analysed through specimen-specific Finite Element models involving purpose-built musculoskeletal loads. Different boundary conditions replicating the post-surgery bone-implant interaction are adopted. The effects of the gait loads on the implants integration are quantified and agree with the results of the experiments. The observed cortical bone loss can be considered as a transient state of integration due to bone disuse atrophy, initially triggered by a loss of bone-implant adhesion and subsequently by a cyclic opening of the interface.
Journal of Anatomy | 2010
Marzio Bergomi; Joël Cugnoni; H. W. Anselm Wiskott; Philipp Schneider; Marco Stampanoni; J. Botsis; Urs C. Belser
The periodontal ligament (PDL) is a highly vascularized soft connective tissue. Previous studies suggest that the viscous component of the mechanical response may be explained by the deformation‐induced collapse and expansion of internal voids (i.e. chiefly blood vessels) interacting with liquids (i.e. blood and interstitial fluids) flowing through the pores. In the present work we propose a methodology by means of which the morphology of the PDL vascular plexus can be monitored at different levels of compressive and tensile strains. To this end, 4‐mm‐diameter cylindrical specimens, comprising layers of bone, PDL and dentin covered by cementum, were strained at stretch ratios ranging from λ = 0.6 to λ = 1.4 and scanned using synchrotron radiation‐based computer tomography. It was concluded that: (1) the PDL vascular network is layered in two distinct planes of blood vessels (BVs): an inner layer (close to the tooth), in which the BVs run in apico‐coronal direction, and an outer layer (close to the alveolar bone), in which the BVs distribution is more diffuse; (2) during tension and compression, the porosity tissue is kept fairly constant; (3) mechanical straining induces important changes in BV diameters, possibly modifying the permeability of the PDL and thus contributing to the viscous component of the viscoelastic response observed under compressive forces.
Composites Science and Technology | 2014
R. Amacher; Joël Cugnoni; J. Botsis; L. Sorensen; W. Smith; C. Dransfeld
Composites Part A-applied Science and Manufacturing | 2007
Larissa Sorensen; J. Botsis; Thomas Gmür; Joël Cugnoni
Collaboration
Dive into the Joël Cugnoni's collaboration.
Swiss Federal Laboratories for Materials Science and Technology
View shared research outputs