Johan Kosmalski
Centre national de la recherche scientifique
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Johan Kosmalski.
Proceedings of SPIE | 2014
Roger Haynes; Samuel C. Barden; Roelof S. de Jong; Olivier Schnurr; Olga Bellido; Jakob Walcher; Dionne M. Haynes; R. Winkler; Svend-Marian Bauer; Frank Dionies; Allar Saviauk; Cristina Chiappini; A. D. Schwope; Joar Brynnel; Matthias Steinmetz; Richard McMahon; Sofia Feltzing; Patrick Francois; Scott Trager; Ian R. Parry; M. J. Irwin; Nicholas A. Walton; David A. King; David Sun; Eduaro Gonzalez-Solares; Ian Tosh; Gavin Dalton; Kevin Middleton; P. Bonifacio; Pascal Jagourel
The 4MOST[1] instrument is a concept for a wide-field, fibre-fed high multiplex spectroscopic instrument facility on the ESO VISTA telescope designed to perform a massive (initially >25x106 spectra in 5 years) combined all-sky public survey. The main science drivers are: Gaia follow up of chemo-dynamical structure of the Milky Way, stellar radial velocities, parameters and abundances, chemical tagging; eROSITA follow up of cosmology with x-ray clusters of galaxies, X-ray AGN/galaxy evolution to z~5, Galactic X-ray sources and resolving the Galactic edge; Euclid/LSST/SKA and other survey follow up of Dark Energy, Galaxy evolution and transients. The surveys will be undertaken simultaneously requiring: highly advanced targeting and scheduling software, also comprehensive data reduction and analysis tools to produce high-level data products. The instrument will allow simultaneous observations of ~1600 targets at R~5,000 from 390-900nm and ~800 targets at R<18,000 in three channels between ~395-675nm (channel bandwidth: 45nm blue, 57nm green and 69nm red) over a hexagonal field of view of ~ 4.1 degrees. The initial 5-year 4MOST survey is currently expect to start in 2020. We provide and overview of the 4MOST systems: optomechanical, control, data management and operations concepts; and initial performance estimates.
Proceedings of SPIE | 2010
Roland Bacon; Matteo Accardo; L. Adjali; Heiko Anwand; Svend-Marian Bauer; I. Biswas; J. Blaizot; D. Boudon; Sylvie Brau-Nogue; Jarle Brinchmann; P. Caillier; L. Capoani; C. M. Carollo; T. Contini; P. Couderc; E. Daguisé; Sebastian Deiries; B. Delabre; S. Dreizler; Jean-Pierre Dubois; M. Dupieux; Christophe Dupuy; Eric Emsellem; T. Fechner; A. Fleischmann; Marc François; G. Gallou; T. Gharsa; Andreas Glindemann; Domingo Gojak
Summary: The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT panoramic integral-field spectrograph currently in manufacturing, assembly and integration phase. MUSE has a field of 1x1 arcmin2 sampled at 0.2x0.2 arcsec2 and is assisted by the VLT ground layer adaptive optics ESO facility using four laser guide stars. The instrument is a large assembly of 24 identical high performance integral field units, each one composed of an advanced image slicer, a spectrograph and a 4kx4k detector. In this paper we review the progress of the manufacturing and report the performance achieved with the first integral field unit.
Proceedings of SPIE | 2006
Roland Bacon; Svend-Marian Bauer; P. Boehm; D. Boudon; Sylvie Brau-Nogue; P. Caillier; L. Capoani; C. M. Carollo; N. Champavert; T. Contini; E. Daguisé; D. Dallé; Bernhard Delabre; Julien Devriendt; S. Dreizler; Jean-Pierre Dubois; M. Dupieux; J. P. Dupin; Eric Emsellem; Pierre Ferruit; Marijn Franx; G. Gallou; J. Gerssen; B. Guiderdoni; T. Hahn; D. Hofmann; Aurélien Jarno; Andreas Kelz; C. Koehler; Wolfram Kollatschny
The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT panoramic integral-field spectrograph under preliminary design study. MUSE has a field of 1x1 arcmin2 sampled at 0.2x0.2 arcsec2 and is assisted by the VLT ground layer adaptive optics ESO facility using four laser guide stars. The simultaneous spectral range is 0.465-0.93 μm, at a resolution of R~3000. MUSE couples the discovery potential of a large imaging device to the measuring capabilities of a high-quality spectrograph, while taking advantage of the increased spatial resolution provided by adaptive optics. This makes MUSE a unique and tremendously powerful instrument for discovering and characterizing objects that lie beyond the reach of even the deepest imaging surveys. MUSE has also a high spatial resolution mode with 7.5x7.5 arcsec2 field of view sampled at 25 milli-arcsec. In this mode MUSE should be able to obtain diffraction limited data-cubes in the 0.6-0.93 μm wavelength range. Although the MUSE design has been optimized for the study of galaxy formation and evolution, it has a wide range of possible applications; e.g. monitoring of outer planets atmosphere, environment of young stellar objects, super massive black holes and active nuclei in nearby galaxies or massive spectroscopic surveys of stellar fields in the Milky Way and nearby galaxies.
Proceedings of SPIE | 2016
Niranjan Thatte; Fraser Clarke; Ian Bryson; Hermine Shnetler; Matthias Tecza; Thierry Fusco; Roland Bacon; Johan Richard; Evencio Mediavilla; Benoit Neichel; S. Arribas; B. García-Lorenzo; C. J. Evans; Alban Remillieux; Kacem El Madi; José Miguel Herreros; Dave Melotte; K. O'Brien; Ian Tosh; J. Vernet; P. L. Hammersley; Derek Ives; Gert Finger; Ryan C. W. Houghton; D. Rigopoulou; J. Lynn; Jamie R. Allen; Simon Zieleniewski; Sarah Kendrew; Vanessa Ferraro-Wood
HARMONI is the E-ELT’s first light visible and near-infrared integral field spectrograph. It will provide four different spatial scales, ranging from coarse spaxels of 60 × 30 mas best suited for seeing limited observations, to 4 mas spaxels that Nyquist sample the diffraction limited point spread function of the E-ELT at near-infrared wavelengths. Each spaxel scale may be combined with eleven spectral settings, that provide a range of spectral resolving powers (R ~3500, 7500 and 20000) and instantaneous wavelength coverage spanning the 0.5 – 2.4 μm wavelength range of the instrument. In autumn 2015, the HARMONI project started the Preliminary Design Phase, following signature of the contract to design, build, test and commission the instrument, signed between the European Southern Observatory and the UK Science and Technology Facilities Council. Crucially, the contract also includes the preliminary design of the HARMONI Laser Tomographic Adaptive Optics system. The instrument’s technical specifications were finalized in the period leading up to contract signature. In this paper, we report on the first activity carried out during preliminary design, defining the baseline architecture for the system, and the trade-off studies leading up to the choice of baseline.
Proceedings of SPIE | 2010
Niranjan Thatte; Mathias Tecza; Fraser Clarke; Roger L. Davies; Alban Remillieux; Roland Bacon; David Lunney; S. Arribas; Evencio Mediavilla; Fernando Gago; Naidu Bezawada; Pierre Ferruit; Ana Fragoso; David Freeman; Javier Fuentes; Thierry Fusco; Angus Gallie; Adolfo Garcia; Timothy Goodsall; Felix Gracia; Aurélien Jarno; Johan Kosmalski; J. Lynn; Stuart McLay; David Montgomery; Arlette Pecontal; Hermine Schnetler; Harry Smith; Dario Sosa; G. Battaglia
We describe the results of a Phase A study for a single field, wide band, near-infrared integral field spectrograph for the European Extremely Large Telescope (E-ELT). HARMONI, the High Angular Resolution Monolithic Optical & Nearinfrared Integral field spectrograph, provides the E-ELTs core spectroscopic requirement. It is a work-horse instrument, with four different spatial scales, ranging from seeing to diffraction-limited, and spectral resolving powers of 4000, 10000 & 20000 covering the 0.47 to 2.45 μm wavelength range. It is optimally suited to carry out a wide range of observing programs, focusing on detailed, spatially resolved studies of extended objects to unravel their morphology, kinematics and chemical composition, whilst also enabling ultra-sensitive observations of point sources. We present a synopsis of the key science cases motivating the instrument, the top level specifications, a description of the opto-mechanical concept, operation and calibration plan, and image quality and throughput budgets. Issues of expected performance, complementarity and synergies, as well as simulated observations are presented elsewhere in these proceedings[1].
Proceedings of SPIE | 2010
Florence Laurent; Louisa Adjali; James A. Arns; Roland Bacon; Didier Boudon; Patrick Caillier; Eric Daguisé; Bernard Delabre; Jean-Pierre Dubois; Philippe Godefroy; Aurélien Jarno; Paul Jorden; Johan Kosmalski; Vincent Lapère; Jean-Louis Lizon; Magali Loupias; Arlette Pecontal; Roland Reiss; Alban Remillieux; Edgard Renault; Gero Rupprecht; Yves Salaun
MUSE (Multi Unit Spectroscopic Explorer) is a second generation VLT panoramic integral field spectrograph developed for the European Southern Observatory (ESO), operating in the visible wavelength range (0.465-0.93 μm). It is composed of 24 identical Integral Field Units (IFU); each one incorporates an advanced image slicer associated with a classical spectrograph and a detector vessel. The Image Slicer subsystem -ISS- is composed of two mirror arrays of 48 spherical elements each. It is made of Zerodur and uses an innovative polishing approach where all individual components are polished together by classical method. The MUSE Spectrograph -SPS-, with fast output focal ratio of f/1.95, implements a Volume Phase Holographic Grating - VPHG. The last subsystem, the Detector Vessel -DV- includes a chip of 4k by 4k 15μm pixels supported by a Vacuum and Cryogenic System - VCS - provided by ESO. The first out of 24 IFUs for MUSE instrument has been manufactured, aligned and tested last months. First, this paper describes the optical design, the manufacturing and test results (image quality, pupil and field of view positioning) of each subsystem independently. Second, we will focus on overall system performance (image quality and positioning) of the spectrograph associated with the detector vessel. At the end, the test results (image quality, positioning, throughput, mechanical interfaces) of the first IFU for MUSE instrument will be reported. Most of them are compliant with requirements that it demonstrates that the manufacturing, integration, alignment and tests processes are mature and gives good confidence for serial production by 24 times applied to MUSE instrument.
Proceedings of SPIE | 2014
Niranjan Thatte; Fraser Clarke; Ian Bryson; Hermine Schnetler; Matthias Tecza; Roland Bacon; Alban Remillieux; Evencio Mediavilla; J. Linares; S. Arribas; C. J. Evans; David Lunney; Thierry Fusco; K. O'Brien; Ian Tosh; Derek Ives; Gert Finger; Ryan C. W. Houghton; Roger L. Davies; J. Lynn; Jamie R. Allen; Simon Zieleniewski; Sarah Kendrew; Vanessa Ferraro-Wood; Arlette Pécontal-Rousset; Johan Kosmalski; Johan Richard; Aurélien Jarno; Angus Gallie; David M. Montgomery
HARMONI is a visible and near-infrared (0.47 to 2.45 μm) integral field spectrometer, providing the E-ELTs core spectroscopic capability, over a range of resolving powers from R (≡λ/Δλ)~500 to R~20000. The instrument provides simultaneous spectra of ~32000 spaxels at visible and near-IR wavelengths, arranged in a √2:1 aspect ratio contiguous field. HARMONI is conceived as a workhorse instrument, addressing many of the E-ELT’s key science cases, and will exploit the E-ELTs scientific potential in its early years, starting at first light. HARMONI provides a range of spatial pixel (spaxel) scales and spectral resolving powers, which permit the user to optimally configure the instrument for a wide range of science programs; from ultra-sensitive to diffraction limited, spatially resolved, physical (via morphology), chemical (via abundances and line ratios) and kinematic (via line-of-sight velocities) studies of astrophysical sources. Recently, the HARMONI design has undergone substantial changes due to significant modifications to the interface with the telescope and the architecture of the E-ELT Nasmyth platform. We present an overview of the capabilities of HARMONI, and of its design from a functional and performance viewpoint.
Proceedings of SPIE | 2006
Florence Laurent; Edgard Renault; Roland Bacon; Bernard Delabre; Jean-Pierre Dubois; François Hénault; Johan Kosmalski
Glass and metallic image slicer breadboards have been designed, manufactured and tested for MUSE (Multi Unit Spectroscopic Explorer) instrument, a second generation integral field spectrograph developed for the European Southern Observatory (ESO) for the VLT. MUSE is operating in the visible and near IR wavelength range (0.465-0.93 μm) and is composed of 24 identical integral field units; each one incorporates an advanced image slicer associated with a classical spectrograph. This presentation describes the optical design, the manufacturing, component test results (shape, roughness, Bidirectional Reflection Distribution Function - BRDF) and overall system performance (image quality, alignment) of two image slicer breadboards. The first one is made of Zerodur and uses individual optical components polished by a classical method and assembled together by molecular adhesion. This breadboard is a combination of mirrors and mini-lens arrays. The second one is made of metal (copper or invar) using monolithic or segmented optical elements and state-ofthe- art diamond-turning machines. It is composed of two sets of reflective mirrors. We will then conclude with a comparison between these two different breadboards by choosing the most suitable solution for the 24 MUSE image slicers.
Proceedings of SPIE | 2008
Florence Laurent; Edgard Renault; Johan Kosmalski; Louisa Adjali; Didier Boudon; Roland Bacon; Patrick Caillier; Alban Remillieux; Yves Salaun; Bernard Delabre
An image slicer breadboard has been designed, manufactured and tested for MUSE (Multi Unit Spectroscopic Explorer) instrument, a second generation integral field spectrograph developed for the European Southern Observatory (ESO) for the VLT. MUSE is operating in the visible and near IR wavelength range (0.465-0.93 μm) and is composed of 24 identical Integral Field Units; each one incorporates an advanced image slicer associated with a classical spectrograph. This paper describes the original optical design, the manufacturing, component test results (shape, roughness, reflectivity, microscopic visualization) and overall system performance (image quality, alignment) of the image slicer breadboard. This one is a combination of two mirror arrays of 48 elements each. It is made of Zerodur and uses a new polishing approach where all individual optical components are polished together by classical method. This image slicer constitutes the first one which has the largest number of active slices (48) associated with strict tolerances in term of positioning. The main results of the tests on this image slicer breadboard will then be presented. Most of them are compliant with requirements. This demonstrates that the manufacturing process is mature and gives good confidence for serial production applied to MUSE instrument.
Proceedings of SPIE | 2012
Magali Loupias; Johan Kosmalski; L. Adjali; Roland Bacon; D. Boudon; L. Brotons; P. Caillier; L. Capoani; E. Daguisé; Aurélien Jarno; G. Hansali; Andreas Kelz; F. Laurent; J. E. Migniau; Arlette Pécontal-Rousset; Laure Piqueras; Alban Remillieux; E. Renault; Ole Streicher; Peter M. Weilbacher; G. Zins
MUSE (Multi Unit Spectroscopic Explorer) is a second generation instrument developed for ESO (European Southern Observatory) and will be assembled to the VLT (Very Large Telescope) in 2013. The MUSE instrument can simultaneously record 90.000 spectra in the visible wavelength range (465-930nm), across a 1*1arcmin² field of view, thanks to 24 identical Integral Field Units (IFU). A collaboration of 7 institutes has partly validated and sent their subsystems to CRAL (Centre de Recherche Astrophysique de Lyon) in 2011, where they have been assembled together. The global test and validation process is currently going on to reach the Preliminary Acceptance in Europe in 2012. The sharing of performances has been based on 5 main functional sub-systems. The Fore Optics sub-system derotates and anamorphoses the VLT Nasmyth focal plane image, the Splitting and Relay Optics associated with the Main Structure are feeding each IFU with 1/24th of the field of view. Each IFU is composed of a 3D function insured by an image slicer system and a spectrograph, and a detection function by a 4k*4k CCD cooled down to 163°K. The 5th function is the calibration and data reduction of the instrument. This article depicts the sequence of tests that has been completely reshafled mainly due to planning constraints. It highlights the priority given to the most critical performances tests of the sub-systems and their results. It enhances then the importance given to global tests. Finally, it makes a status on the verification matrix and the validation of the instrument and gives a critical view on the risks taken.