Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Johannes Herta is active.

Publication


Featured researches published by Johannes Herta.


Neurophysiologie Clinique-clinical Neurophysiology | 2015

Automatic detection of rhythmic and periodic patterns in critical care EEG based on American Clinical Neurophysiology Society (ACNS) standardized terminology.

Franz Fürbass; Manfred Hartmann; J.J. Halford; J. Koren; Johannes Herta; Andreas Gruber; C. Baumgartner; Tilmann Kluge

AIMS OF THE STUDY Continuous EEG from critical care patients needs to be evaluated time efficiently to maximize the treatment effect. A computational method will be presented that detects rhythmic and periodic patterns according to the critical care EEG terminology (CCET) of the American Clinical Neurophysiology Society (ACNS). The aim is to show that these detected patterns support EEG experts in writing neurophysiological reports. MATERIALS AND METHODS First of all, three case reports exemplify the evaluation procedure using graphically presented detections. Second, 187 hours of EEG from 10 critical care patients were used in a comparative trial study. For each patient the result of a review session using the EEG and the visualized pattern detections was compared to the original neurophysiology report. RESULTS In three out of five patients with reported seizures, all seizures were reported correctly. In two patients, several subtle clinical seizures with unclear EEG correlation were missed. Lateralized periodic patterns (LPD) were correctly found in 2/2 patients and EEG slowing was correctly found in 7/9 patients. In 8/10 patients, additional EEG features were found including LPDs, EEG slowing, and seizures. CONCLUSION The use of automatic pattern detection will assist in review of EEG and increase efficiency. The implementation of bedside surveillance devices using our detection algorithm appears to be feasible and remains to be confirmed in further multicenter studies.


Clinical Neurophysiology | 2017

Applicability of NeuroTrend as a bedside monitor in the neuro ICU

Johannes Herta; Johannes Koren; Franz Fürbass; A. Zöchmeister; Manfred Hartmann; A. Hosmann; Christoph Baumgartner; Andreas Gruber

OBJECTIVE To assess whether ICU caregivers can correctly read and interpret continuous EEG (cEEG) data displayed with the computer algorithm NeuroTrend (NT) with the main attention on seizure detection and determination of sedation depth. METHODS 120 screenshots of NT (480h of cEEG) were rated by 18 briefly trained nurses and biomedical analysts. Multirater agreements (MRA) as well as interrater agreements (IRA) compared to an expert opinion (EXO) were calculated for items such as pattern type, pattern location, interruption of recording, seizure suspicion, consistency of frequency, seizure tendency and level of sedation. RESULTS MRA as well as IRA were almost perfect (80-100%) for interruption of recording, spike-and-waves, rhythmic delta activity and burst suppression. A substantial agreement (60-80%) was found for electrographic seizure patterns, periodic discharges and seizure suspicion. Except for pattern localization (70.83-92.26%), items requiring a precondition and especially those who needed interpretation like consistency of frequency (47.47-79.15%) or level of sedation (41.10%) showed lower agreements. CONCLUSIONS The present study demonstrates that NT might be a useful bedside monitor in cases of subclinical seizures. Determination of correct sedation depth by ICU caregivers requires a more detailed training. SIGNIFICANCE Computer algorithms may reduce the workload of cEEG analysis in ICU patients.


Clinical Neurophysiology | 2016

Monitoring burst suppression in critically ill patients: Multi-centric evaluation of a novel method.

Franz Fürbass; Johannes Herta; Johannes Koren; M. Brandon Westover; Manfred Hartmann; Andreas Gruber; Christoph Baumgartner; Tilmann Kluge

OBJECTIVE To develop a computational method to detect and quantify burst suppression patterns (BSP) in the EEGs of critical care patients. A multi-center validation study was performed to assess the detection performance of the method. METHODS The fully automatic method scans the EEG for discontinuous patterns and shows detected BSP and quantitative information on a trending display in real-time. The method is designed to work without setting any patient specific parameters and to be insensitive to EEG artifacts and periodic patterns. For validation a total of 3982 h of EEG from 88 patients were analyzed from three centers. Each EEG was annotated by two reviewers to assess the detection performance and the inter-rater agreement. RESULTS Average inter-rater agreement between pairs of reviewers was κ=0.69. On average 22% of the review segments included BSP. An average sensitivity of 90% and a specificity of 84% were measured on the consensus annotations of two reviewers. More than 95% of the periodic patterns in the EEGs were correctly suppressed. CONCLUSION A fully automatic method to detect burst suppression patterns was assessed in a multi-center study. The method showed high sensitivity and specificity. SIGNIFICANCE Clinically applicable burst suppression detection method validated in a large multi-center study.


Central European Neurosurgery | 2015

De Novo Aneurysm Formation at the Anastomosis Site Incidentally Detected 2 Years after Single-Barrel STA-MCA Bypass Surgery: Case Report and Review of the Literature

Matthias Millesi; Wei-Te Wang; Johannes Herta; Gerhard Bavinzski; Andreas Gruber

This case report describes the de novo aneurysm formation at the anastomosis site 2 years after single-barrel superficial temporal artery to middle cerebral artery bypass surgery. Correct bypass patency and morphology of the anastomosis site was documented intraoperatively and immediately postoperatively by indocyanine green videoangiography and digital subtraction angiography (DSA). Aneurysmatic dilatation at the anastomosis site was observed 2 years postoperatively upon computed tomography angiographic follow-up examination. After repeat DSA, the patient underwent microsurgical reexploration and clip ligation of the aneurysmatic portion of the donor artery. The possible underlying mechanisms are discussed and the current literature is reviewed.


Frontiers in Neurology | 2018

Automated Long-Term EEG Review: Fast and Precise Analysis in Critical Care Patients

Johannes Koren; Johannes Herta; Franz Fürbass; Susanne Pirker; Veronika Reiner-Deitemyer; Franz Riederer; Julia Flechsenhar; Manfred Hartmann; Tilmann Kluge; Christoph Baumgartner

Background: Ongoing or recurrent seizure activity without prominent motor features is a common burden in neurological critical care patients and people with epilepsy during ICU stays. Continuous EEG (CEEG) is the gold standard for detecting ongoing ictal EEG patterns and monitoring functional brain activity. However CEEG review is very demanding and time consuming. The purpose of the present multirater, EEG expert reviewer study, is to test and assess the clinical feasibility of an automatic EEG pattern detection method (Neurotrend). Methods: Four board certified EEG reviewers used Neurotrend to annotate 76 CEEG datasets à 6 h (in total 456 h of EEG) for rhythmic and periodic EEG patterns (RPP), unequivocal ictal EEG patterns and burst suppression. All reviewers had a predefined time limit of 5 min (± 2 min) per CEEG dataset and were compared to a predefined gold standard (conventional EEG review with unlimited time). Subanalysis of specific features of RPP was conducted as well. We used Gwets AC1 and AC2 coefficients to calculate interrater agreement (IRA) and multirater agreement (MRA). Also, we determined individual performance measures for unequivocal ictal EEG patterns and burst suppression. Bonferroni-Holmes correction for multiple testing was applied to all statistical tests. Results: Mean review time was 3.3 min (± 1.9 min) per CEEG dataset. We found substantial IRA for unequivocal ictal EEG patterns (0.61–0.79; mean sensitivity 86.8%; mean specificity 82.2%, p < 0.001) and burst suppression (0.68–0.71; mean sensitivity 96.7%; mean specificity 76.9% p < 0.001). Two reviewers showed substantial IRA for RPP (0.68–0.72), whereas the other two showed moderate agreement (0.45–0.54), compared to the gold standard (p < 0.001). MRA showed almost perfect agreement for burst suppression (0.86) and moderate agreement for RPP (0.54) and unequivocal ictal EEG patterns (0.57). Conclusions: We demonstrated the clinical feasibility of an automatic critical care EEG pattern detection method on two levels: (1) reasonable high agreement compared to the gold standard, (2) reasonable short review times compared to previously reported EEG review times with conventional EEG analysis.


Clinical Neurophysiology | 2018

Automatic ictal onset source localization in presurgical epilepsy evaluation

Johannes Koren; Gerhard Gritsch; Susanne Pirker; Johannes Herta; Hannes Perko; Tilmann Kluge; Christoph Baumgartner

OBJECTIVE To test the diagnostic accuracy of a new automatic algorithm for ictal onset source localization (IOSL) during routine presurgical epilepsy evaluation following STARD (Standards for Reporting of Diagnostic Accuracy) criteria. METHODS We included 28 consecutive patients with refractory focal epilepsy (25 patients with temporal lobe epilepsy (TLE) and 3 with extratemporal epilepsy) who underwent resective epilepsy surgery. Ictal EEG patterns were analyzed with a novel automatic IOSL algorithm. IOSL source localizations on a sublobar level were validated by comparison with actual resection sites and seizure free outcome 2 years after surgery. RESULTS Sensitivity of IOSL was 92.3% (TLE: 92.3%); specificity 60% (TLE: 50%); positive predictive value 66.7% (TLE: 66.7%); and negative predictive value 90% (TLE: 85.7%). The likelihood ratio was more than ten times higher for concordant IOSL results as compared to discordant results (p = 0.013). CONCLUSIONS We demonstrated the clinical feasibility of our IOSL approach yielding reasonable high performance measures on a sublobar level. SIGNIFICANCE Our IOSL method may contribute to a correct localization of the seizure onset zone in temporal lobe epilepsy and can readily be used in standard epilepsy monitoring settings. Further studies are needed for validation in extratemporal epilepsy.


Clinical Neurophysiology | 2018

Platform Session – Evoked potentials & NIOM: Reduced electrode arrays for the automated detection of rhythmic and periodic patterns in the intensive care unit: Frequently tried, frequently failed?

Johannes Herta; Johannes Koren; Franz Fürbass; Manfred Hartmann; Andreas Gruber; Christoph Baumgartner

Introduction To investigate the effect of systematic electrode reduction from a common 10–20 EEG system on pattern detection sensitivity (SEN). Methods Two reviewers rated 17,130 one-minute segments of 83 prospectively recorded cEEGs according to the ACNS standardized critical care EEG terminology (CCET), including burst suppression patterns (BS) and unequivocal electrographic seizures. Consensus annotations between reviewers were used as a gold standard to determine pattern detection SEN and specificity (SPE) of a computational algorithm (baseline, 19 electrodes). Electrodes were than reduced one by one in four different variations. SENs and SPEs were calculated to determine the most beneficial assembly with respect to the number and location of electrodes. Results High automated baseline SENs (84.99–93.39%) and SPEs (90.05–95.6%) were achieved for all patterns. Best overall results in detecting BS and CCET patterns were found using the “hairline + vertex” montage. While the “forehead + behind ear” montage showed an advantage in detecting ictal patterns, reaching a 15% drop of SEN with 10 electrodes, all montages could detect BS sufficiently if at least nine electrodes were available. Conclusion For the first time an automated approach was used to systematically evaluate the effect of electrode reduction on pattern detection SEN in cEEG. Prediction of the expected detection SEN of specific EEG patterns with reduced EEG montages in ICU patients.


Clinical Neurophysiology | 2016

ID 145 – NeuroTrend: Prospective validation of rhythmic and periodic pattern detection method for Scalp

Franz Fürbass; Johannes Herta; Johannes Koren; Ana M. Skupch; Manfred Hartmann; Tilmann Kluge; Andreas Gruber; Christoph Baumgartner

NeuroTrend is a computational method that automatically analyses long-term scalp EEGs in the ICU according to ACNS standardized critical care EEG terminology (CCET). At present, it is a screening aid to facilitate the review process and optimize resources. A prospective multi-center study was performed in two neuro-ICUs including 68 patients who were subjected to continuous video-EEG (cEEG). Two reviewers independently annotated the first minute of each hour in the cEEG according to CCET and electrographic seizures. The matching annotations (2911 segments) were then used as gold standard condition to test sensitivity and specificity of the rhythmic and periodic pattern detection of NeuroTrend. Inter-rater agreement was substantial for main term 1 and main term 2 of the CCET. The overall detection sensitivity of NeuroTrend was 94% with high detection rates for periodic discharges (PD 81%) and rhythmic delta activity (RDA 82%). The overall specificity was 67% due to false positive detections of RDA in cases of general slowing. In contrast, for PDs a detection specificity of 88% was reached. NeuroTrend is suitable as a screening tool for cEEG in the ICU and will raise the efficiency of long-term EEG-monitoring in the ICU. Pattern differentiation between RDA and general slowing still needs improvement.


Epilepsy & Behavior | 2015

Prospective assessment and validation of rhythmic and periodic pattern detection in NeuroTrend: A new approach for screening continuous EEG in the intensive care unit

Johannes Herta; J. Koren; Franz Fürbass; Manfred Hartmann; Tilmann Kluge; Christoph Baumgartner; Andreas Gruber


Clinical Neurophysiology | 2016

Rhythmic and periodic EEG patterns of ‘ictal–interictal uncertainty’ in critically ill neurological patients

Johannes Koren; Johannes Herta; Susanne Pirker; Franz Fürbass; Manfred Hartmann; Tilmann Kluge; Christoph Baumgartner

Collaboration


Dive into the Johannes Herta's collaboration.

Top Co-Authors

Avatar

Manfred Hartmann

Austrian Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Franz Fürbass

Austrian Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Andreas Gruber

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar

Tilmann Kluge

Austrian Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Johannes Koren

Massachusetts Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J.J. Halford

Medical University of South Carolina

View shared research outputs
Top Co-Authors

Avatar

Hannes Perko

Austrian Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge