Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where John Edwin Charles Gibbons is active.

Publication


Featured researches published by John Edwin Charles Gibbons.


Clinica Chimica Acta | 1996

A simple near-patient test for nicotine and its metabolites in urine to assess smoking habit

Graham Cope; Pamela Nayyar; Roger Holder; John Edwin Charles Gibbons; Roger Abraham Bunce

We describe a disposable, near-patient urine test to monitor cigarette smoking. A plastic device contains the sealed dried reagents to measure nicotine and its metabolites, by a colorimetric assay. The device can be used to give a qualitative assessment of tobacco consumption, simply by observing a colour change. Alternatively, the test can be quantified by measuring the light absorbance with a simple colorimeter, and a concentration of nicotinic metabolites obtained with reference to a cotinine standard. A correction factor for the concentration of the urine sample, based on light absorbance, allows the result to be expressed as a ratio to urine concentration. This method correlates with reported daily cigarette consumption (r = 0.69, p < 0.0001) and compares favourably with cotinine, as measured by gas chromatography (r = 0.89, p < 0.0001). The method provides a simple-to-use, inexpensive way to monitoring tobacco consumption in extralaboratory situations.


Analyst | 1985

Camera luminometer for use with luminescent assays

Roger Abraham Bunce; Gary Harold Gregory Henry Thorpe; John Edwin Charles Gibbons; Paul R. Killeen; Gregory Ogden; Larry J. Kricka; Thomas Patterson Whitehead

An instrument, a camera luminometer, has been developed that detects light emission from luminescent reactions using high-speed instant photographic film (ASA 20000). The luminometer simultaneously monitors light emission from 63 reaction vessels in the form of a 7 × 9 array. It also incorporates a multiple pipette, which enables luminescent reactions to be simultaneously initiated directly above the instant film. Photographic results are interpreted visually and semi-quantitative assessment is possible. This may be improved by interposing a stepped neutral density filter between each reaction vessel and the film. The application of this instrument is illustrated by an enhanced luminescent enzyme immunoassay for serum ferritin and chemiluminescent assays for Co(II), Cr(III), peroxide and luminol. The film has a limited exposure latitude and so the assays operate as threshold tests with the following detection limits: ferritin, 1 ng; Co(II), 5 pmol; Cr(III), 500 fmol; peroxide, 500 pmol; and luminol, 500 fmol.


Journal of Automated Methods & Management in Chemistry | 1989

Application of robotics In the clinical laboratory

Roger Abraham Bunce; P. M. G. Broughton; D. M. Browning; John Edwin Charles Gibbons; Larry J. Kricka

The basic types of robot are explained, and the performances and costs of some commercial examples are given. The potential advantages and problems of introducing robots into clinical laboratories are identified and the specifcation of a suitable robot is developed. None of the commercially available robots meets all aspects of the specificalion, and currently the purchase of a robot is considered premature for most clinical laboratories.


Archive | 1990

Liquid transfer devices

Roger Abraham Bunce; Gary Harold Gregory Hen Thorpe; John Edwin Charles Gibbons; Louise Jane Keen; Matthew Robert Walker


Archive | 1983

Dispensing device and recording apparatus

T.P. Whitehead; Gary Harold Gregory Henry Thorpe; Larry J. Kricka; John Edwin Charles Gibbons; Roger Abraham Bunce


Archive | 2001

Combustion simulating device

Anthony Christopher Ryan; Roger Abraham Bunce; John Edwin Charles Gibbons; Stephen John Starsmore; Mark Stuart Ryan


Archive | 1988

Assay apparatus and use thereof.

Roger Abraham Bunce; John Edwin Charles Gibbons; Jayne A. Matthews; Catherine Ann Burn; Larry Jan Kricka


Archive | 1980

Improvements in or relating to pipette means

Roger Abraham Bunce; John Edwin Charles Gibbons; Larry Jan Kricka


Emerging Therapeutic Targets | 1997

A Simple Near-Patient Urine Test for Nicotine and Its Metabolites to Assess Smoking Habit

Graham Cope; Pamela Nayyar; John Edwin Charles Gibbons; Roger Abraham Bunce


Archive | 1992

Prüfungsvorrichtung Testing device

Graham Cope; Roger Abraham Bunce; John Edwin Charles Gibbons

Collaboration


Dive into the John Edwin Charles Gibbons's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

T.P. Whitehead

University of Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Graham Cope

University of Birmingham

View shared research outputs
Top Co-Authors

Avatar

Larry J. Kricka

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Pamela Nayyar

University of Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Roger Holder

University of Birmingham

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge