Publication


Featured researches published by John F. Seely.


Applied Optics | 1998

High-resolution monochromatic x-ray imaging system based on spherically bent crystals.

Y. Aglitskiy; Thomas Lehecka; Stephen Obenschain; Stephen E. Bodner; Carl Pawley; Kent Gerber; John Sethian; Charles M. Brown; John F. Seely; Uri Feldman; Glenn E. Holland

We have developed an improved x-ray imaging system based on spherically curved crystals. It is designed and used for diagnostics of targets ablatively accelerated by the Nike KrF laser. A spherically curved quartz crystal (d = .?, R = mm) has been used to produce monochromatic backlit images with the He-like Si resonance line (1865 eV) as the source of radiation. The spatial resolution of the x-ray optical system is 1.7 mum in selected places and 2-3 mum over a larger area. Time-resolved backlit monochromatic images of polystyrene planar targets driven by the Nike facility have been obtained with a spatial resolution of 2.5 mum in selected places and 5 mum over the focal spot of the Nike laser.


Other Information: PBD: 3 May 1999 | 1999

Study of 2D laser beam imprinting using an asymmetric channel cut crystal

John F. Seely; Charles M. Brown; Glenn E. Holland

The contents of this report cover the following three topics: (1) design of the asymmetric channel cut crystal; (2) fabrication of the silicon crystal; and (3) experimental x-ray data.


Archive | 2011

Mobile X-ray unit

Craig N. Boyer; Glenn E. Holland; John F. Seely


Archive | 1999

Dual energy x-ray densitometry apparatus and method using single x-ray pulse

John F. Seely; Craig N. Boyer; Glenn E. Holland


Archive | 1998

Capacitor mounting arrangement for marx generators

Glenn E. Holland; Craig N. Boyer; John F. Seely


Archive | 1998

Field emission tube for a mobile X-ray unit

Glenn E. Holland; Craig N. Boyer; John F. Seely


Archive | 2001

Trigger circuit for Marx generators

John F. Seely; Craig N. Boyer; Glenn E. Holland


Archive | 2016

High Resolution X-Ray Spectrometer for Precision EXAFS Measurements in the 6 keV to 15 keV Energy Range | NIST

Lawrence T. Hudson; John F. Seely; Albert Henins; U. Feldman


Archive | 2010

Spectroscopy of positron annihilation gamma rays from laser-exited media

Csilla I. Szabo; U. Feldman; John F. Seely; Lawrence T. Hudson; H. Chen; Riccardo Tommasini; Andrew U. Hazi; R. Shepherd; C. Zulick; Franklin J. Dollar; K. Falk; C. D. M. Murphy


Archive | 2008

A proposed new method for the determination of the solar irradiance at EUV wavelength range

U. Feldman; G. A. Doschek; John F. Seely; E. Landi; Ingolf E. Dammasch

Researchain Logo
Decentralizing Knowledge