John W. Kakareka
Center for Information Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by John W. Kakareka.
Cerebral Cortex | 2011
Fatta B. Nahab; Prantik Kundu; Cecile Gallea; John W. Kakareka; Randy Pursley; Tom Pohida; Nathaniel Miletta; Jason Friedman; Mark Hallett
Self-agency (SA) is the individuals perception that an action is the consequence of his/her own intention. The neural networks underlying SA are not well understood. We carried out a novel, ecologically valid, virtual-reality experiment using blood oxygen level-dependent functional magnetic resonance imaging (fMRI) where SA could be modulated in real-time while subjects performed voluntary finger movements. Behavioral testing was also performed to assess the explicit judgment of SA. Twenty healthy volunteers completed the experiment. Results of the behavioral testing demonstrated paradigm validity along with the identification of a bias that led subjects to over- or underestimate the amount of control they had. The fMRI experiment identified 2 discrete networks. These leading and lagging networks likely represent a spatial and temporal flow of information, with the leading network serving the role of mismatch detection and the lagging network receiving this information and mediating its elevation to conscious awareness, giving rise to SA.
Journal of Magnetic Resonance | 2003
Randall Pursley; John W. Kakareka; Ghadi Salem; Nallathamby Devasahayam; Sankaran Subramanian; Rolf Tschudin; Murali C. Krishna; Thomas J. Pohida
The application of correlation spectroscopy employing stochastic excitation and the Hadamard transform to time-domain Fourier transform electron paramagnetic resonance (FT-EPR) spectroscopy in the radiofrequency (RF) band is described. An existing, time-domain FT-EPR spectrometer system with a Larmor frequency (L(f)) of 300 MHz was used to develop this technique by incorporating a pseudo-random pulse sequence generator to output the maximum length binary sequence (MLBS, 10- and 11-bit). Software developed to control the EPR system setup, acquire the signals, and post process the data, is outlined. The software incorporates the Hadamard transform algorithm to perform the required cross-correlation of the acquired signal and the MLBS after stochastic excitation. To accommodate the EPR signals, bandwidth extension was accomplished by sampling at a rate many times faster than the RF pulse repetition rate, and subsequent digital signal processing of the data. The results of these experiments showed that there was a decrease in the total acquisition time, and an improved free induction decay (FID) signal-to-noise (S/N) ratio compared to the conventional coherent averaging approach. These techniques have the potential to reduce the RF pulse power to the levels used in continuous wave (CW) EPR while retaining the advantage of time-domain EPR methods. These methods have the potential to facilitate the progression to in vivo FT-EPR imaging of larger volumes.
Nuclear Medicine and Biology | 2010
Wenze Xi; Jurgen Seidel; John W. Kakareka; Thomas J. Pohida; Diane E. Milenic; James Proffitt; Stan Majewski; Andrew G. Weisenberger; Michael V. Green; Peter L. Choyke
INTRODUCTIONnWe describe a compact, portable dual-gamma camera system (named MONICA for MObile Nuclear Imaging CAmeras) for visualizing and analyzing the whole-body biodistribution of putative diagnostic and therapeutic single photon emitting radiotracers in animals the size of mice.nnnMETHODSnTwo identical, miniature pixelated NaI(Tl) gamma cameras were fabricated and installed looking up through the tabletop of a compact portable cart. Mice are placed directly on the tabletop for imaging. Camera imaging performance was evaluated with phantoms and field performance was evaluated in a weeklong In-111 imaging study performed in a mouse tumor xenograft model.nnnRESULTSnTc-99m performance measurements, using a photopeak energy window of 140 keV+/-10%, yielded the following results: spatial resolution (FWHM at 1 cm), 2.2 mm; sensitivity, 149 cps (counts per seconds)/MBq (5.5 cps/microCi); energy resolution (FWHM, full width at half maximum), 10.8%; count rate linearity (count rate vs. activity), r(2)=0.99 for 0-185 MBq (0-5 mCi) in the field of view (FOV); spatial uniformity, <3% count rate variation across the FOV. Tumor and whole-body distributions of the In-111 agent were well visualized in all animals in 5-min images acquired throughout the 168-h study period.nnnCONCLUSIONnPerformance measurements indicate that MONICA is well suited to whole-body single photon mouse imaging. The field study suggests that inter-device communications and user-oriented interfaces included in the MONICA design facilitate use of the system in practice. We believe that MONICA may be particularly useful early in the (cancer) drug development cycle where basic whole-body biodistribution data can direct future development of the agent under study and where logistical factors, e.g., limited imaging space, portability and, potentially, cost are important.
PLOS ONE | 2015
Suk Yun Kang; Chang-Hwan Im; Miseon Shim; Fatta B. Nahab; Ji Hye Park; D.H. Kim; John W. Kakareka; Nathanial Miletta; Mark Hallett
Background Self-agency (SA) is a person’s feeling that his action was generated by himself. The neural substrates of SA have been investigated in many neuroimaging studies, but the functional connectivity of identified regions has rarely been investigated. The goal of this study is to investigate the neural network related to SA. Methods SA of hand movements was modulated with virtual reality. We examined the cortical network relating to SA modulation with electroencephalography (EEG) power spectrum and phase coherence of alpha, beta, and gamma frequency bands in 16 right-handed, healthy volunteers. Results In the alpha band, significant relative power changes and phase coherence of alpha band were associated with SA modulation. The relative power decrease over the central, bilateral parietal, and right temporal regions (C4, Pz, P3, P4, T6) became larger as participants more effectively controlled the virtual hand movements. The phase coherence of the alpha band within frontal areas (F7-FP2, F7-Fz) was directly related to changes in SA. The functional connectivity was lower as the participants felt that they could control their virtual hand. In the other frequency bands, significant phase coherences were observed in the frontal (or central) to parietal, temporal, and occipital regions during SA modulation (Fz-O1, F3-O1, Cz-O1, C3-T4L in beta band; FP1-T6, FP1-O2, F7-T4L, F8-Cz in gamma band). Conclusions Our study suggests that alpha band activity may be the main neural oscillation of SA, which suggests that the neural network within the anterior frontal area may be important in the generation of SA.
Journal of Magnetic Resonance | 2012
Raisa Z. Freidlin; John W. Kakareka; Thomas J. Pohida; Michal E. Komlosh; Peter J. Basser
In vivo MRI data can be corrupted by motion. Motion artifacts are particularly troublesome in Diffusion Weighted MRI (DWI), since the MR signal attenuation due to Brownian motion can be much less than the signal loss due to dephasing from other types of complex tissue motion, which can significantly degrade the estimation of self-diffusion coefficients, diffusion tensors, etc. This paper describes a snapshot DWI sequence, which utilizes a novel single-sided bipolar diffusion sensitizing gradient pulse within a spin echo sequence. The proposed method shortens the diffusion time by applying a single refocused bipolar diffusion gradient on one side of a refocusing RF pulse, instead of a set of diffusion sensitizing gradients, separated by a refocusing RF pulse, while reducing the impact of magnetic field inhomogeneity by using a spin echo sequence. A novel MRI phantom that can exhibit a range of complex motions was designed to demonstrate the robustness of the proposed DWI sequence.
nuclear science symposium and medical imaging conference | 2010
Jurgen Seidel; Wenze Xi; John W. Kakareka; Thomas J. Pohida; Michael V. Green; Peter L. Choyke
Certain experimental questions in molecular imaging can be answered with projection imaging systems rather than tomographs. Accordingly, we have designed, assembled and are now testing a projection imaging system able to visualize the whole-body distribution of positron-emitting compounds in mouse-size animals. When completed, this positron projection imager (PPI) will plug into the MONICA portable dual gamma camera system to provide the user with a positron projection imaging capability and all of the data acquisition and analysis features available with MONICA for single photon projection imaging.
PLOS ONE | 2015
Suk Yun Kang; Chang-Hwan Im; Miseon Shim; Fatta B. Nahab; Ji Hye Park; D.H. Kim; John W. Kakareka; Nathanial Miletta; Mark Hallett
[This corrects the article DOI: 10.1371/journal.pone.0135261.].
Nuclear Medicine and Biology | 2013
Jurgen Seidel; Wenze Xi; John W. Kakareka; Thomas J. Pohida; Elaine M. Jagoda; Michael V. Green; Peter L. Choyke
INTRODUCTIONnWe describe a prototype positron projection imager (PPI) for visualizing the whole-body biodistribution of positron-emitting compounds in mouse-size animals. The final version of the PPI will be integrated into the MONICA portable dual-gamma camera system to allow the user to interchangeably image either single photon or positron-emitting compounds in a shared software and hardware environment.nnnMETHODSnA mouse is placed in the mid-plane between two identical, opposed, pixelated LYSO arrays separated by 21.8-cm and in time coincidence. An image of the distribution of positron decays in the animal is formed on this mid-plane by coincidence events that fall within a small cone angle perpendicular to the two detectors and within a user-specified energy window. We measured the imaging performance of this device with phantoms and in tests performed in mice injected with various compounds labeled with positron-emitting isotopes.nnnRESULTSnRepresentative performance measurements yielded the following results (energy window 250-650keV, cone angle 3.5°): resolution in the image mid-plane, 1.66-mm (FWHM), resolution ±1.5-cm above and below the image plane, 2.2-mm (FWHM), sensitivity: 0.237-cps/kBq (8.76-cps/μCi) (18)F (0.024% absolute). Energy resolution was 15.9% with a linear-count-rate operating range of 0-14.8MBq (0-400μCi) and a corrected sensitivity variation across the field-of-view of <3%. Whole-body distributions of [(18)F] FDG and [(18)F] fluoride were well visualized in mice of typical size.nnnCONCLUSIONnPerformance measurements and field studies indicate that the PPI is well suited to whole-body positron projection imaging of mice. When integrated into the MONICA gamma camera system, the PPI may be particularly useful early in the drug development cycle where, like MONICA, basic whole-body biodistribution data can direct future development of the agent under study and where logistical factors (e.g., available imaging space, non-portability, and cost) may be limitations.
Frontiers in Aging Neuroscience | 2018
Daniel A. Pupo; John W. Kakareka; Jonathan Krynitsky; Lorenzo Leggio; Tom Pohida; Stephanie A. Studenski; Brandon K. Harvey
Monitoring age-related changes in motor function can be used to identify deviations that represent underlying diseases for which early diagnosis is often paramount for efficacious, interventional therapies. Currently, the availability of cost-effective and reliable diagnostic tools capable of routine monitoring is limited. Adequate diagnostic systems are needed to identify, monitor and distinguish early subclinical symptoms of neurological diseases from normal aging-associated changes. Herein, we describe the development, initial validation and reliability of the Hand-Arm Movement Monitoring System (HAMMS), a video-based data acquisition system built using a programmable, versatile platform for acquiring temporal and spatial metrics of hand and arm movements. A healthy aging population of 111 adults were used to evaluate the HAMMS via a repetitive motion test of changing target size. The test required participants to move a fiducial on their hand between two targets presented on a video monitor. The test-retest reliability based on Intraclass Correlation Coefficient (ICCs) for the system ranged from 0.56 to 0.87 and the Linear Correlation Coefficients (LCCs) ranged from 0.58 to 0.87. Average speed, average acceleration, speed error and center offset all demonstrated a positive correlation with age. Using an intertarget path of hand motion, we observed an age-dependent increase in the average number of points outside the most direct motion path, indicating a reduction in hand-arm movement control with age. The reliability, flexibility and programmability of the HAMMS makes this low cost, video-based platform an effective tool for evaluating longitudinal changes in hand-arm related movements and a potential diagnostic device for neurological diseases where hand-arm movements are affected.
Applied Spectroscopy | 2015
Richard W. Hendler; Curtis W. Meuse; Travis Gallagher; Joerg Labahn; Jan Kubicek; Paul D. Smith; John W. Kakareka
It has long been known in spectroscopy that light not passing through a sample, but reaching the detector (i.e., stray light), results in a distortion of the spectrum known as absorption flattening. In spectroscopy with crystals, one must either include such stray light or take steps to exclude it. In the former case, the derived spectra are not accurate. In the latter case, a significant amount of the crystal must be masked off and excluded. In this paper, we describe a method that allows use of the entire crystal by correcting the distorted spectrum.