Joo-young Kang
Samsung
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Joo-young Kang.
international conference on image processing | 2013
Kyu-hong Kim; Suhyun Park; Sung-Chan Park; Joo-young Kang; Yun-Tae Kim; Jung-Ho Kim
Minimum Variance (MV) beamforming has been studied for high resolution ultrasonic imaging. However, it is not easy for the MV beamformer to be implemented into a real time diagnostic system, because it requires too many computations for covariance matrix inversion. We introduce a transform-based adaptive beamforming algorithm for ultrasound medical imaging where the transformation can reduce the dimension of the covariance matrix in estimating beamformation weights. Moreover, it is shown that beamformation result can be directly calculated in the transformed domain. Experimental results indicate that our beamforming method shows better resolution and contrast under a real phantom and in-vivo environment.
Proceedings of SPIE | 2013
Joo-young Kang; Sung-Chan Park; Kyu-hong Kim; Jung-Ho Kim
In the ultrasound medical imaging system, blurring which occurs after passing through ultrasound scanner system, represents Point Spread Function (PSF) that describes the response of the ultrasound imaging system to a point source distribution. So, de-blurring can be achieved by de-convolving the images with an estimated of PSF. However, it is hard to attain an accurate estimation of PSF due to the unknown properties of the tissues of the human body through the ultrasound signal propagates. In addition to, the complexity is very high in order to estimate point spread function and de-convolve the ultrasound image with estimated PSF for real-time implementation of ultrasound imaging. Therefore, conventional methods of ultrasound image restoration are based on a simple 1D PSF estimation [8] that axial direction only by restoring the performance improvement is not in the direction of Lateral. And, in case of 2D PSF estimation, PSF estimation and restoration of the high complexity is not being widely used. In this paper, we proposed new method for selection of the 2D PSF (estimated PSF of the average speed sound and depth) simultaneously with performing fast non-blind 2D de-convolution in the ultrasound imaging system. Our algorithm works on the beam-formed uncompressed radio-frequency data, with pre-measured and estimated 2D PSFs database from actual probe used. In the 2d PSF database, there are pre-measured and estimated 2D PSFs that classified the each different depth (about 5 different depths) and speed of sound (about 1450 or 1540m/s). Using a minimum variance and simple Weiner filter method, we present a novel way to select the optimal 2D PSF in pre-measured and estimated 2D PSFs database that acquired from the actual transducer being used. For de-convolution part with the chosen PSF, we focused on the low complexity issue. So, we are using the Weiner Filter and fast de-convolution technique using hyper-Laplacian priors [11], [12] which is several orders of magnitude faster than existing techniques that use hyper-Laplacian priors. Then, in order to prevent discontinuities between the differently restored each depth image regions, we use the piecewise linear interpolation on overlapping regions. We have tested our algorithm with vera-sonic system and commercial ultrasound scanner (Philips C4-2), in known speed of sound phantoms and unknown speeds in vivo scans. We have applied a non-blind de-convolution with 2D PSFs database for ultrasound imaging system. Using the real PSF from actual transducer being used, our algorithm produces a better restoration of ultrasound image than de-convolution by simulated PSF, and has low complexity for real-time ultrasound imaging. This method is robust and easy to implement. This method may be a realistic candidate for real-time implementation.
Proceedings of SPIE | 2014
Joo-young Kang; Sung-Chan Park; Jung-Ho Kim; Jongkeun Song
In the ultrasound imaging system, blurring which occurs after passing through ultrasound scanner system, represents point spread function (PSF) that describes the response of the ultrasound imaging system to a point source distribution. So, de-blurring can be achieved by de-convolving the ultrasound images with an estimated of corresponding PSF. However, it is hard to attain an accurate estimation of PSF due to the unknown properties of the tissues of the human body through the ultrasound signal propagates. In this paper, we present a new method for PSF estimation in the Fourier domain (FD) based on parametric minimum phase information, and simultaneously, it performs fast 2D de-convolution in the ultrasound imaging system. Although most of complex cepstrum methods [14], are obtained using complex 2D phase unwrapping [18] [19] in order to estimate the FD-phase information of PSF, our algorithm estimates the 2D PSF using 2D FD-phase information with the parametric weighting factor α and β. They affect the feature of PSF shapes.This makes the computations much simpler and the estimation more accurate. Our algorithm works on the beam-formed uncompressed radio-frequency data, with pre-measured and estimated 2D PSFs database from actual probe used. We have tested our algorithm with vera-sonic system and commercial ultrasound scanner (Philips C4-2), in known speed of sound phantoms and unknown speeds in vivo scans.
Proceedings of SPIE | 2014
Yun-Tae Kim; Kyu-hong Kim; Sung-Chan Park; Joo-young Kang; Jung-Ho Kim
This paper proposes realistic fetus skin color processing using a 2D color map and a tone mapping function (TMF) for ultrasound volume rendering. The contributions of this paper are a 2D color map generated through a gamut model of skin color and a TMF that depends on the lighting position. First, the gamut model of fetus skin color is calculated by color distribution of baby images. The 2D color map is created using a gamut model for tone mapping of ray casting. For the translucent effect, a 2D color map in which lightness is inverted is generated. Second, to enhance the contrast of rendered images, the luminance, color, and tone curve TMF parameters are changed using 2D Gaussian function that depends on the lighting position. The experimental results demonstrate that the proposed method achieves better realistic skin color reproduction than the conventional method.
Archive | 2009
Byung-kwan Park; Hyun-wook Ok; Joo-young Kang; Jae-guyn Lim
Archive | 2009
Jae-guyn Lim; Byung-kwan Park; Seong-deok Lee; Youngkyoo Hwang; Hyun-wook Ok; Joo-young Kang
Archive | 2014
Joo-young Kang; Hyun-wook Ok; Seong-deok Lee; Hyun-hwa Oh
Archive | 2010
Joo-young Kang; Hyun-wook Ok; Seong-deok Lee; Byung-kwan Park; Jae-guyn Lim
Archive | 2010
Joo-young Kang; Byung-kwan Park; Sang-Wook Han; Seong-deok Lee; Won-Hee Choe; Jae-guyn Lim
Archive | 2010
Joo-young Kang; Sang-Wook Han; Won-Hee Choe; Seong-deok Lee