Sensors | 2017
Gwanghee Heo; Joonryong Jeon
In this paper, a data compression technology-based intelligent data acquisition (IDAQ) system was developed for structural health monitoring of civil structures, and its validity was tested using random signals (El-Centro seismic waveform). The IDAQ system was structured to include a high-performance CPU with large dynamic memory for multi-input and output in a radio frequency (RF) manner. In addition, the embedded software technology (EST) has been applied to it to implement diverse logics needed in the process of acquiring, processing and transmitting data. In order to utilize IDAQ system for the structural health monitoring of civil structures, this study developed an artificial filter bank by which structural dynamic responses (acceleration) were efficiently acquired, and also optimized it on the random El-Centro seismic waveform. All techniques developed in this study have been embedded to our system. The data compression technology-based IDAQ system was proven valid in acquiring valid signals in a compressed size.
Sensors | 2018
Gwanghee Heo; Byungjik Son; Chunggil Kim; Seunggon Jeon; Joonryong Jeon
A disaster preventive structural health monitoring (SHM) system needs to be equipped with the following abilities: First, it should be able to simultaneously measure diverse types of data (e.g., displacement, velocity, acceleration, strain, load, temperature, humidity, etc.) for accurate diagnosis. Second, it also requires standalone power supply to guarantee its immediate response in crisis (e.g., sudden interruption of normal AC power in disaster situations). Furthermore, it should be capable of prompt processing and realtime wireless communication of a huge amount of data. Therefore, this study is aimed at developing a wireless unified-maintenance system (WUMS) that would satisfy all the requirements for a disaster preventive SHM system of civil structures. The WUMS is designed to measure diverse types of structural responses in realtime based on wireless communication, allowing users to selectively use WiFi RF band and finally working in standalone mode by means of the field-programmable gate array (FPGA) technology. To verify its performance, the following tests were performed: (i) A test to see how far communication is possible in open field, (ii) a test on a shaker to see how accurate responses are, (iii) a modal test on a bridge to see how exactly characteristic real-time dynamic responses are of structures. The test results proved that the WUMS was able to secure stable communication far up to nearly 800 m away by acquiring wireless responses in realtime accurately, when compared to the displacement and acceleration responses which were acquired through wired communication. The analysis of dynamic characteristics also showed that the wireless acceleration responses in real-time represented satisfactorily the dynamic properties of structures. Therefore, the WUMS is proved valid as a SHM, and its outstanding performance is also proven.
Journal of Physics: Conference Series | 2016
Gwanghee Heo; Chunggil Kim; Seunggon Jeon; S Seo; Joonryong Jeon
In this paper, a hybrid seismic response control (HSRC) system was developed to control bridge motion caused by seismic load. It was aimed at optimum vibration control, composed of a rubber bearing of passive type and a MR-damper of semi-active type. The bridge model was built for experiment, a two-span bridge of 8.3 meters in length with the HSRC system put up on it. Then, inflicting El-centro seismic load on it, shaking table tests were carried out to confirm the systems validity. The experiments were conducted under the basic structure state (without an MR-damper applied) first, and then under the state with an MR-damper applied. It was also done under the basic structure state with a reinforced rubber bearing applied, then the passive on/off state of the HSRC system, and finally the semi-active state where the control algorithm was applied to the system. From the experiments, it was observed that collision rather increased when the MR-damper alone was applied, and also that the application of the HSRC system effectively prevented it from occurring. As a result, the HSRC system was proven to be effective in mitigating responses of the two-span bridge under seismic load.
Smart Structures and Materials 2006: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems | 2006
Gwanghee Heo; WooSang Lee; Giu Lee; Joonryong Jeon; ChangHwan Kim
This paper attempts to validate the effectiveness of wireless sensor unit by field experiments on a self-anchored suspension bridge. This wireless sensor unit was developed at Konyang Universitys SIS lab in Korea for real-time dynamic response measurement of structures. This sensing unit called SWMAS(Smart Wireless MEMS-based Sensor System) consists of a sensor system module, a control and processing module, and a wireless modem module. In order to evaluate whether SWMAS would be applicable to structural monitoring system, experiments were performed to a full-scaled structure, which was a self-anchored suspension bridge, a wire-based monitoring system placed inside. In the field experiments, the data from the ambient vibrations of the bridge were acquired in real-time using SWMAS. All data acquired were compared with those of wire-based monitoring system. As a result, the comparison proved that SWMAS would be effectively applicable to smart monitoring system.
Key Engineering Materials | 2006
Gwanghee Heo; Joonryong Jeon; Chin Ok Lee; Gui Lee; Woo Sang Lee
This paper presents an effective method of FE model updating for health monitoring of structures by applying ambient vibration. And this method is experimented through damage detection and proved to be valid. Experiment about ambient vibration is performed on cantilever beam, and the dynamic characteristics are analyzed by NExT and ERA. The results of such experiments are compared to those of FE analysis, and this comparison enables us to overcome some errors in experiments and analysis. On the basis of improved results by the comparison, model updating is performed in order to construct a basic structure for health monitoring. For model updating, we employ direct matrix updating method (DMUM) and Error matrix method (EMM) in which ambient vibration is easily applied. The model updating by the methods are again evaluated in terms of error ratio of natural frequency, comparing each result before and after updating. Finally, we perform experiments on damage detection to verify the method of updating presented here, and evaluate its performance by eigen-parameter change method. The evaluation proves that the method of FE model updating using ambient vibration is effective for health monitoring of structure, and some further application of this method is suggested.
Shock and Vibration | 2016
Gwanghee Heo; Joonryong Jeon
This paper aims to develop an SI (structural identification) technique using the KEOT and the DMUM to decide on optimal location of sensors and to update FE model, respectively, which ultimately contributes to a composition of more effective SHM. Owing to the characteristic structural flexing behavior of cable bridges (e.g., cable-stayed bridges and suspension bridges), which makes them vulnerable to any vibration, systematic and continuous structural health monitoring (SHM) is pivotal for them. Since it is necessary to select optimal measurement locations with the fewest possible measurements and also to accurately assess the structural state of a bridge for the development of an effective SHM, an SI technique is as much important to accurately determine the modal parameters of the current structure based on the data optimally obtained. In this study, the kinetic energy optimization technique (KEOT) was utilized to determine the optimal measurement locations, while the direct matrix updating method (DMUM) was utilized for FE model updating. As a result of experiment, the required number of measurement locations derived from KEOT based on the target mode was reduced by approximately 80% compared to the initial number of measurement locations. Moreover, compared to the eigenvalue of the modal experiment, an improved FE model with a margin of error of less than 1% was derived from DMUM. Thus, the SI technique for cable-stayed bridges proposed in this study, which utilizes both KEOT and DMUM, is proven effective in minimizing the number of sensors while accurately determining the structural dynamic characteristics.
Journal of The Earthquake Engineering Society of Korea | 2016
Gwanghee Heo; Joonryong Jeon; Seunggon Jeon
This paper is concerned with an experimental research to control of random vibration caused by external loads specially in cable-stayed bridges which tend to be structurally flexible. For the vibration control, we produced a model structure modelled on Seohae Grand Bridge, and we designed a shear type MR damper. On the center of its middle span, we placed a shear type MR damper which was to control its vibration and also acquire its structural responses such as displacement and acceleration at the same site. The experiments concerning controlling vibration were performed according to a variety of theories including un-control, passive on/off control, and clipped-optimal control. Its control performance was evaluated in terms of the absolute maximum displacements, RMS displacements, the absolute maximum accelerations, RMS accelerations, and the total power required to control the bridge which differ from each different experiment method. Among all the methods applied in this paper, clipped-optimal control method turned out to be the most effective to reduces of displacements, accelerations, and external power. Finally, It is proven that the clipped-optimal control method was effective and useful in the vibration control employing a semi-active devices such MR damper.
Journal of The Earthquake Engineering Society of Korea | 2016
Gwanghee Heo; Seunggon Jeon; Chunggil Kim; Joonryong Jeon; Chin-Ok Lee; Sanggu Seo
In the case where a MR-damper is employed for vibration control, it is important to decide on how much control capacity should be assigned to it against structural capacities (strength and load, etc). This paper aims to present a MR-dampers control capacity suitable for the capacities of the structure which needs to be controlled. First, a two span bridge was built equipped with a MR-damper, which constitutes a two-span MR-damper control system. Then, inflicting an earthquake load on the system, a basic experiment was performed for vibration control, and a simulation was also carried out reflecting specific control conditions such as MR-damper and rubber bearing. The comparison of the results against each other proved their validity. Then, in order to calculate an optimal control capacity of the MR-damper, structural capacity was divided into eleven cases in total and simulated. For each case, an additional load of 30 KN was inflicted everytime, thereby increasingly strengthening structural capacity. As a result of the study, it was found that the control capacity of MR-damper of 30 KN was safely secured only with lumped mass of more than 150 KN(case 6). Therefore, it is concluded the MR-damper showed the best performance of control when it exerted its capacity at around 20% of structural capacity.
Journal of Physics: Conference Series | 2016
Gwanghee Heo; Joonryong Jeon; B Son; Chunggil Kim; Seunggon Jeon; Chin-Ok Lee
In this study, a cochlea-inspired artificial filter bank (CAFB) was developed to efficiently obtain dynamic response of a structure, and a dynamic response measurement of a cable-stayed bridge model was also carried out to evaluate the performance of the developed CAFB. The developed CAFB used a band-pass filter optimizing algorithm (BOA) and peakpicking algorithm (PPA) to select and compress dynamic response signal containing the modal information which was significant enough. The CAFB was then optimized about the El-Centro earthquake wave which was often used in the construction research, and the software implementation of CAFB was finally embedded in the unified structural management system (USMS). For the evaluation of the developed CAFB, a real time dynamic response experiment was performed on a cable-stayed bridge model, and the response of the cable-stayed bridge model was measured using both the traditional wired system and the developed CAFB-based USMS. The experiment results showed that the compressed dynamic response acquired by the CAFB-based USMS matched significantly with that of the traditional wired system while still carrying sufficient modal information of the cable-stayed bridge.
Transactions of The Korean Society for Noise and Vibration Engineering | 2015
Gwanghee Heo; Joonryong Jeon; Seunggon Jeon
In this paper, a cochlea-inspired artificial filter bank(CAFB) was developed in order to efficiently acquire dynamic response of structure, and it was also evaluated via dynamic response experiments. To sort out signals containing significant modal information from all the dynamic responses of structure, it was made to adopt a band-pass filter optimizing algorithm(BOA) and a peak-picking algorithm (PPA). Optimally designed on the basis of El-centro and Kobe earthquake signals, it was then embedded into the wireless multi-measurement system(WiMMS). In order to evaluate the performance of the developed CAFB, a vibration test was conducted using the El-centro and Kobe earthquake signals, and structural responses of a two-span bridge were obtained and analyzed simultaneously by both a wired measurement system and a CAFB-based WiMMS. The test results showed that the compressed dynamic responses acquired by the CAFB-based WiMMS matched with those of the wired system, and they included significant modal information of the two-span bridge. Therefore this study showed that the developed CAFB could be used as a new, economic, and efficient measurement device for wireless sensor networks(WSNs) based real time structural health monitoring because it could reconstruct the whole dynamic response using the compressed dynamic response with significant modal information.