Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Joost F. Swennenhuis is active.

Publication


Featured researches published by Joost F. Swennenhuis.


Journal of Clinical Oncology | 2010

Significant and Sustained Antitumor Activity in Post-Docetaxel, Castration-Resistant Prostate Cancer With the CYP17 Inhibitor Abiraterone Acetate

Alison Reid; Gerhardt Attard; Daniel C. Danila; Nikhil Babu Oommen; David Olmos; Peter C.C. Fong; L. Rhoda Molife; Joanne Hunt; Christina Messiou; Chris Parker; David P. Dearnaley; Joost F. Swennenhuis; Leon W.M.M. Terstappen; Gloria Lee; Thian Kheoh; Arturo Molina; Charles J. Ryan; Eric J. Small; Howard I. Scher; Johann S. de Bono

PURPOSE The principal objective of this trial was to evaluate the antitumor activity of abiraterone acetate, an oral, specific, irreversible inhibitor of CYP17 in docetaxel-treated patients with castration-resistant prostate cancer (CRPC). PATIENTS AND METHODS In this multicenter, two-stage, phase II study, abiraterone acetate 1,000 mg was administered once daily continuously. The primary end point was achievement of a prostate-specific antigen (PSA) decline of > or = 50% in at least seven of 35 patients. Per an attained phase II design, more than 35 patients could be enrolled if the primary end point was met. Secondary objectives included: PSA declines of > or = 30% and > or = 90%; rate of RECIST (Response Evaluation Criteria in Solid Tumors) responses and duration on study; time to PSA progression; safety and tolerability; and circulating tumor cell (CTC) enumeration. RESULTS Docetaxel-treated patients with CRPC (N = 47) were enrolled. PSA declines of > or = 30%, > or = 50% and > or = 90% were seen in 68% (32 of 47), 51% (24 of 47), and 15% (seven of 47) of patients, respectively. Partial responses (by RECIST) were reported in eight (27%) of 30 patients with measurable disease. Median time to PSA progression was 169 days (95% CI, 113 to 281 days). The median number of weeks on study was 24, and 12 (25.5%) of 47 patients remained on study > or = 48 weeks. CTCs were enumerated in 34 patients; 27 (79%) of 34 patients had at least five CTCs at baseline. Eleven (41%) of 27 patients had a decline from at least five to less than 5 CTCs, and 18 (67%) of 27 had a > or = 30% decline in CTCs after starting treatment with abiraterone acetate. Abiraterone acetate was well tolerated. CONCLUSION Abiraterone acetate has significant antitumor activity in post-docetaxel patients with CRPC. Randomized, phase III trials of abiraterone acetate are underway to define the future role of this agent.


Cytometry Part A | 2009

Characterization of circulating tumor cells by fluorescence in situ hybridization

Joost F. Swennenhuis; Arjan G.J. Tibbe; Rianne Levink; Ronald Sipkema; Leon W.M.M. Terstappen

Tumor cells in blood of patients with metastatic carcinomas have been associated with poor survival prospects. Further characterization of these cells may provide further insights into the metastatic process. Circulating Tumor Cells (CTC) were enumerated in 7.5 mL of blood with the CellSearch™ system. After enumeration of Cytokeratin+, CD45−, nucleated cells, the cells are fixed in the cartridge while maintaining their original position. Cartridges were hybridized with FISH probes against the centromeric regions of chromosome 1, 7, 8, and 17. Next fluorescence images of the FISH probes of the previous identified CTC were acquired. Leukocytes surrounding the CTC were used as internal controls. The number of copies of chromosome 1, 7, 8, and 17 could be determined in 118 CTC containing blood samples from 59 metastatic prostate cancer patients. The samples contained a total of 21,751 CTC (mean 184, median 16, SD 650). Chromosome counts were obtained in 61% of the relocated CTC. On an average, these CTC contained 2.8 copies of chromosome 1, 2.7 copies of chromosome 7, 3.1 copies of chromosome 8, and 2.3 copies of chromosome 17. CTC in which no chromosome count was obtained most likely underwent apoptosis indicated by the expression of M30. In 6/59 patients only diploid CTC were detected these samples, however, only contained 1–5 CTC. Heterogeneity in the chromosomal abnormalities was observed between CTC of different patients as well as among CTC of the same patient. Cytogenetic composition of CTC can be reliably assessed after they have been identified by the CellSearch™ system. The majority of CTC in hormone refractory prostate cancer are aneuploid confirming that they indeed are cancer cells. An extensive heterogeneity in the copy number of each of the chromosomes was observed.


Genome Medicine | 2013

Efficiency of whole genome amplification of single circulating tumor cells enriched by CellSearch and sorted by FACS

Joost F. Swennenhuis; Joke Reumers; K. Thys; J. Aerssens; Leonardus Wendelinus Mathias Marie Terstappen

BackgroundTumor cells in the blood of patients with metastatic carcinomas are associated with poor survival. Knowledge of the cells’ genetic make-up can help to guide targeted therapy. We evaluated the efficiency and quality of isolation and amplification of DNA from single circulating tumor cells (CTC).MethodsThe efficiency of the procedure was determined by spiking blood with SKBR-3 cells, enrichment with the CellSearch system, followed by single cell sorting by fluorescence-activated cell sorting (FACS) and whole genome amplification. A selection of single cell DNA from fixed and unfixed SKBR-3 cells was exome sequenced and the DNA quality analyzed. Single CTC from patients with lung cancer were used to demonstrate the potential of single CTC molecular characterization.ResultsThe overall efficiency of the procedure from spiked cell to amplified DNA was approximately 20%. Losses attributed to the CellSearch system were around 20%, transfer to FACS around 25%, sorting around 5% and DNA amplification around 25%. Exome sequencing revealed that the quality of the DNA was affected by the fixation of the cells, amplification, and the low starting quantity of DNA. A single fixed cell had an average coverage at 20× depth of 30% when sequencing to an average of 40× depth, whereas a single unfixed cell had 45% coverage. GenomiPhi-amplified genomic DNA had a coverage of 72% versus a coverage of 87% of genomic DNA. Twenty-one percent of the CTC from patients with lung cancer identified by the CellSearch system could be isolated individually and amplified.ConclusionsCTC enriched by the CellSearch system were sorted by FACS, and DNA retrieved and amplified with an overall efficiency of 20%. Analysis of the sequencing data showed that this DNA could be used for variant calling, but not for quantitative measurements such as copy number detection. Close to 55% of the exome of single SKBR-3 cells were successfully sequenced to 20× depth making it possible to call 72% of the variants. The overall coverage was reduced to 30% at 20× depth, making it possible to call 56% of the variants in CellSave-fixed cells.


Cytometry Part A | 2012

Automated identification of circulating tumor cells by image cytometry

T.M. Scholtens; F. Schreuder; Sjoerd Ligthart; Joost F. Swennenhuis; Jan Greve; Leonardus Wendelinus Mathias Marie Terstappen

Presence of circulating tumor cells (CTC), as detected by the CellSearch® System, in patients with metastatic carcinomas is associated with poor survival prospects. CellTracks TDI, a dedicated image cytometer, was developed to improve the enumeration of these rare CTC. The CellSearch System was used to enumerate CTC in 7.5 mL blood of 68 patients with cancer and 9 healthy controls. Cartridges containing the fluorescently labeled CTC from this system were reanalyzed using the image cytometer, which acquires images with a TDI camera using a 40×/0.6 NA objective and lasers as light source. Automated classification of events was performed by the Random Forest method using Matlab. An automated classifier was developed to classify events into CTC, apoptotic CTC, CTC debris, leukocytes, and debris not related to CTC. A high agreement in classification was obtained between the automated classifier and five expert reviewers. Comparison of images from the same events in CellTracks TDI and CellTracks Analyzer II shows improved resolution in fluorescence images and improved classification by adding bright‐field images. Improved detection efficiency for CD45‐APC avoids the classification of leukocytes nonspecifically binding to cytokeratin as CTC. The correlation between number of CTC detected in CellTracks TDI and CellTracks Analyzer II is good with a slope of 1.88 and a correlation coefficient of 0.87. Automated classification of events by CellTracks TDI eliminates the operator error in classification of events as CTC and permits quantitative assessment of parameters. The clinical relevance of various CTC definitions can now be investigated.


Cytometry Part A | 2011

CellTracks TDI: an Image Cytometer for Cell Characterization.

T.M. Scholtens; F. Schreuder; Sjoerd Ligthart; Joost F. Swennenhuis; Arjan G.J. Tibbe; Jan Greve; Leonardus Wendelinus Mathias Marie Terstappen

Characterization of rare cells usually requires high sensitivity quantification of multiple parameters. Detection of morphological features of these cells is highly desired when routinely identifying circulating tumor cells (CTC) in blood of patients. We have designed an image cytometer intended for fast and sensitive routine analysis of CTC. After an initial scan, prospective events can be revisited for more detailed analysis. The image cytometer features: 375, 491, and 639 nm laser lines, a 40×/0.6NA objective, a CCD camera operating in TDI mode, servo stages to move the sample in two dimensions and a piëzo microscope objective positioner to move the objective in the third dimension. ImageJ is used for dedicated image analysis. A homogeneous illumination area, measuring 180 × 180 μm2, was created by the use of a rotating diffuser in combination with two micro‐lens arrays. For feed‐forward automatic focusing of the sample during a scan, a 3D spline was fitted through 30 predetermined focus positions before scanning the sample. Continuous signal acquisition is made possible by using a CCD operating in TDI mode synchronized to the movement of two servo scan stages. The limit of fluorescence sensitivity is 120 PE molecules on a bead with a diameter of 6.8 μm, at a scanning speed of 1.0 mm s−1. The resolution of the imaging system is 0.76 μm in the TDI scan direction at a wavelength of 580 nm. Identification of cells is facilitated by scatter plots of the fluorescent parameters in which each individual event can be viewed for its morphological features by fluorescence as well as bright field. The image cytometer measures quantitative fluorescence and morphological features at a high sensitivity, high resolution, and with minimal overhead time. It has the ability torelocate events of interest for further detailed analysis. The system can be used for routine identification and characterization of rare cells.


PLOS ONE | 2014

Parallel Single Cancer Cell Whole Genome Amplification Using Button-Valve Assisted Mixing in Nanoliter Chambers

Yoonsun Yang; Joost F. Swennenhuis; Hoon Suk Rho; Séverine Le Gac; Leon W.M.M. Terstappen

The heterogeneity of tumor cells and their alteration during the course of the disease urges the need for real time characterization of individual tumor cells to improve the assessment of treatment options. New generations of therapies are frequently associated with specific genetic alterations driving the need to determine the genetic makeup of tumor cells. Here, we present a microfluidic device for parallel single cell whole genome amplification (pscWGA) to obtain enough copies of a single cell genome to probe for the presence of treatment targets and the frequency of its occurrence among the tumor cells. Individual cells were first captured and loaded into eight parallel amplification units. Next, cells were lysed on a chip and their DNA amplified through successive introduction of dedicated reagents while mixing actively with the help of integrated button-valves. The reaction chamber volume for scWGA 23.85 nl, and starting from 6–7 pg DNA contained in a single cell, around 8 ng of DNA was obtained after WGA, representing over 1000-fold amplification. The amplified products from individual breast cancer cells were collected from the device to either directly investigate the amplification of specific genes by qPCR or for re-amplification of the DNA to obtain sufficient material for whole genome sequencing. Our pscWGA device provides sufficient DNA from individual cells for their genetic characterization, and will undoubtedly allow for automated sample preparation for single cancer cell genomic characterization.


Nucleic Acids Research | 2012

Construction of repeat-free Fluorescence In situ Hybridization probes

Joost F. Swennenhuis; B. Foulk; F.A.W. Coumans; Leonardus Wendelinus Mathias Marie Terstappen

FISH probes are generally made out of BAC clones with genomic DNA containing a variable amount of repetitive DNA that will need to be removed or blocked for FISH analysis. To generate repeat free (RF) Probes without loss in genomic coverage, a random library is made from BAC clones by whole-genome amplification (WGA). Libraries are denatured in the presence of excess C0t-1 DNA and allowed to re-anneal followed by digestion of all double-stranded elements by duplex-specific nuclease (DSN). Selective amplification of all elements not containing repetitive sequences is realized by a sequential amplification. The final RF products can be re-amplified and used as a stock for future probe production. The RF probes have a lower background, the signal intensity build up is faster and there is no need for blocking DNA. The signal to background ratio of the RF was higher as compared to repeat containing probes.


Methods of Molecular Biology | 2015

Sample Preparation Methods Following CellSearch Approach Compatible of Single-Cell Whole-Genome Amplification: An Overview

Joost F. Swennenhuis; Leonardus Wendelinus Mathias Marie Terstappen

Single cells are increasingly used to determine the heterogeneity of therapy targets in the genome during the course of a disease. The first challenge using single cells is to isolate these cells from the surrounding cells, especially when the targeted cells are rare. A number of techniques have been developed for this goal, each having specific limitations and possibilities. In this chapter, five of these techniques are discussed in the light of the isolation of circulating tumor cells (CTC) present at extremely low frequency in the blood of patients with metastatic cancer from the perspective of pre-enriched samples by means of CellSearch. The techniques described are micromanipulation, FACS, laser capture microdissection, DEPArray, and microfluidic solutions. All platforms are hampered with a low efficiency and differences in hands-on time and costs are the most important drivers for selection of the optimal platform.


Lab on a Chip | 2014

A novel side electrode configuration integrated in fused silica microsystems for synchronous optical and electrical spectroscopy

Sertan Sukas; Erik Schreuder; Bjorn de Wagenaar; Joost F. Swennenhuis; Albert van den Berg; Leon W.M.M. Terstappen; Séverine Le Gac

We present a novel electrode configuration consisting of coplanar side electrode pairs integrated at the half height of the microchannels for the creation of a homogeneous electric field distribution as well as for synchronous optical and electrical measurements. For the integration of such electrodes in fused silica microsystems, a dedicated microfabrication method was utilized, whereby an intermediate bonding layer was applied to lower the temperature for fusion bonding to avoid thereby metal degradation and subsequently to preserve the electrode structures. Finally, we demonstrate the applicability of our devices with integrated electrodes for single cell electrical lysis and simultaneous fluorescence and impedance measurements for both cell counting and characterization.


Recent results in cancer research | 2012

Immunomagnetic Separation Technologies

A.E.L.M. Hoeppener; Joost F. Swennenhuis; Leonardus Wendelinus Mathias Marie Terstappen

The largest difficulty one faces in the development of technology for detection of circulating tumor cells (CTCs) is whether or not tumor cells are present in the blood and at what frequency. Although the introduction of the validated CellSearch system for CTC enumeration has facilitated CTC research the question remains whether CTC are missed or whether the CTC that are reported are indeed clinically relevant. To fulfill the promise of CTC as a real-time liquid biopsy they will need to be present in the blood volume tested and need to be isolated without losing the ability to test the presence of treatment targets. To characterize a sufficiently large number of CTCs in the majority of cancer patients the volume of blood needed is simply too large to process without enrichment prior to detection. Here, we review the detection of CTCs by flow cytometry and fluorescence microscopy with and without immunomagnetic enrichment.

Collaboration


Dive into the Joost F. Swennenhuis's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Johann S. de Bono

The Royal Marsden NHS Foundation Trust

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gemma Fowler

Institute of Cancer Research

View shared research outputs
Top Co-Authors

Avatar

Mariane Sousa Fontes

The Royal Marsden NHS Foundation Trust

View shared research outputs
Top Co-Authors

Avatar

Mateus Crespo

Institute of Cancer Research

View shared research outputs
Researchain Logo
Decentralizing Knowledge