Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where José Maria de Andrade Lopes is active.

Publication


Featured researches published by José Maria de Andrade Lopes.


Jornal De Pediatria | 2008

Perinatal factors associated with early deaths of preterm infants born in Brazilian Network on Neonatal Research centers

Maria Fernanda Branco de Almeida; Ruth Guinsburg; Francisco Eulógio Martinez; Renato S. Procianoy; Cléa Rodrigues Leone; Sérgio Tadeu Martins Marba; Ligia Maria Suppo de Souza Rugolo; Jorge Hecker Luz; José Maria de Andrade Lopes

OBJECTIVE To evaluate perinatal factors associated with early neonatal death in preterm infants with birth weights (BW) of 400-1,500 g. METHODS A multicenter prospective cohort study of all infants with BW of 400-1,500 g and 23-33 weeks of gestational age (GA), without malformations, who were born alive at eight public university tertiary hospitals in Brazil between June of 2004 and May of 2005. Infants who died within their first 6 days of life were compared with those who did not regarding maternal and neonatal characteristics and morbidity during the first 72 hours of life. Variables associated with the early deaths were identified by stepwise logistic regression. RESULTS A total of 579 live births met the inclusion criteria. Early deaths occurred in 92 (16%) cases, varying between centers from 5 to 31%, and these differences persisted after controlling for newborn illness severity and mortality risk score (SNAPPE-II). According to the multivariate analysis, the following factors were associated with early intrahospital neonatal deaths: gestational age of 23-27 weeks (odds ratio - OR = 5.0; 95%CI 2.7-9.4), absence of maternal hypertension (OR = 1.9; 95%CI 1.0-3.7), 5th minute Apgar 0-6 (OR = 2.8; 95%CI 1.4-5.4), presence of respiratory distress syndrome (OR = 3.1; 95%CI 1.4-6.6), and network center of birth. CONCLUSION Important perinatal factors that are associated with early neonatal deaths in very low birth weight preterm infants can be modified by interventions such as improving fetal vitality at birth and reducing the incidence and severity of respiratory distress syndrome. The heterogeneity of early neonatal rates across the different centers studied indicates that best clinical practices should be identified and disseminated throughout the country.


The Journal of Pediatrics | 2011

Red Blood Cell Transfusions are Independently Associated with Intra-Hospital Mortality in Very Low Birth Weight Preterm Infants

Amélia Miyashiro Nunes dos Santos; Ruth Guinsburg; Maria Fernanda Branco de Almeida; Renato S. Procianoy; Cléa Rodrigues Leone; Sérgio Tadeu Martins Marba; Ligia Maria Suppo de Souza Rugolo; Humberto Holmer Fiori; José Maria de Andrade Lopes; Francisco Eulógio Martinez

OBJECTIVE To test the hypothesis that red blood cell (RBC) transfusions in preterm infants are associated with increased intra-hospital mortality. STUDY DESIGN Variables associated with death were studied with Cox regression analysis in a prospective cohort of preterm infants with birth weight <1500 g in the Brazilian Network on Neonatal Research. Intra-hospital death and death after 28 days of life were analyzed as dependent variables. Independent variables were infant demographic and clinical characteristics and RBC transfusions. RESULTS Of 1077 infants, 574 (53.3%) received at least one RBC transfusion during the hospital stay. The mean number of transfusions per infant was 3.3 ± 3.4, with 2.1 ± 2.1 in the first 28 days of life. Intra-hospital death occurred in 299 neonates (27.8%), and 60 infants (5.6%) died after 28 days of life. After adjusting for confounders, the relative risk of death during hospital stay was 1.49 in infants who received at least one RBC transfusion in the first 28 days of life, compared with infants who did not receive a transfusion. The risk of death after 28 days of life was 1.89 times higher in infants who received more than two RBC transfusions during their hospital stay, compared with infants who received one or two transfusions. CONCLUSION Transfusion was associated with increased death, and transfusion guidelines should consider risks and benefits of transfusion.


Revista De Saude Publica | 1998

Valores de predição da avaliação neurológica e ultra-sonográfica cerebral neonatal em relação ao desenvolvimento de prematuros de muito baixo peso

Rosane Reis de Mello; Maria Virgínia Peixoto Dutra; Kátia Silveira da Silva; José Maria de Andrade Lopes

OBJETIVO: Verificar os valores de predicao de dois exames (neurologico e ultra-sonografico) realizados no periodo neonatal, em relacao ao desenvolvimento neuromotor e cognitivo de prematuros. METODO: Foram estudados 70 prematuros com peso de nascimento inferior a 1.500g. A media do peso de nascimento e idade gestacional foram, respectivamente, 1.185g (DP:180) e 32,2 semanas (DP:1,4). Foi realizada avaliacao neurologica pelo metodo de Dubowitz e Dubowitz e ultra-sonografia cerebral por volta de 40 semanas de idade corrigida. Apos a alta do bercario estas criancas foram acompanhadas no ambulatorio de seguimento. RESULTADOS: Com idade media de 21 meses (DP: 4,9) corrigidos para a prematuridade, 25,7% das criancas apresentaram comprometimento neuromotor, e 20,3%, alteracao cognitiva. O exame neurologico neonatal foi mais sensivel que especifico em relacao a alteracao neuromotora (sensibilidade:77,7%, especificidade:57,6%), e cognitiva (sensibilidade: 78,5%, especificidade: 56,4%), e apresentou baixo valor de predicao tanto para alteracao neuromotora (38,9%) quanto cognitiva (31,4%). A ultra-sonografia apresentou elevada especificidade tanto para o desenvolvimento neuromotor (92,3%) quanto cognitivo (89,1%). O valor preditivo da ultra-sonografia foi satisfatorio para anormalidades neuromotoras (69,2%), porem baixo para as alteracoes cognitivas (50,0%). CONCLUSAO: A associacao dos dois exames com resultados anormais apresentou valores de predicao mais elevados para as anormalidades nas duas areas do desenvolvimento.


Jornal De Pediatria | 2008

Medication errors in a neonatal intensive care unit

Renata Bandeira de Melo Escovedo Lerner; Manoel de Carvalho; Alan A. Vieira; José Maria de Andrade Lopes; Maria Elisabeth Lopes Moreira

OBJECTIVE To determine the incidence and type of medical errors in a newborn intensive care unit and the relationship between the error and the patients clinical status. METHODS We reviewed the medical charts, during the first 7 days of hospitalization, of all high-risk newborn infants admitted for a period of 3 months. RESULTS Seventy-three patients were admitted during the study period. Their mean birth weight was 2,140 g (640-5,020 g) and mean gestational age was 34 weeks (25-40 weeks). Of 73 medical charts analyzed, 40 (55%) had one or more errors. A total of 365 days of hospitalization was analyzed and 95 medical errors were detected (one error per 3.9 days of hospitalization). The most frequent error was associated with medication use (84.2%). Use of therapeutic procedures (drugs, phototherapy, etc.) without proper prescription in the patients chart (commission error) accounted for 7.4% of the errors, and incidence of omission errors was 8.4%. Incidence of medical errors was significantly higher in newborn infants with lower gestational age. CONCLUSIONS Incidence of errors in the care of high-risk newborn infants is elevated. Strategies to improve education of health professionals involved in the care and development of local culture by disseminating clear, accessible algorithms to guide behavior when errors occur must be encouraged.


Cadernos De Saude Publica | 2005

Assistência e mortalidade neonatal no setor público do Município do Rio de Janeiro, Brasil: uma análise do período 1994/2000

Maria Auxiliadora de Souza Mendes Gomes; José Maria de Andrade Lopes; Maria Elizabeth Lopes Moreira; Nicole Oliveira Mota Gianini

This article analyzes an intervention by the Rio de Janeiro Municipal Health Department (SMS-RJ), Brazil, to reduce the neonatal mortality rate (strategies for organizing and upgrading neonatal care in the municipal system, including an increase in the number of neonatal high-risk beds). We studied the trends in neonatal mortality rate (1995/2000), neonatal care provided in different public hospitals (1994/2000), and admissions profile and mortality in four neonatal intensive care units (NICUs) under the SMS-RJ (2000). There was a concentration of high-risk neonatal care in the municipal hospitals (an increase from 28.0% of the care provided for live premature neonates in 1994 to 67.0% in 2000) and a reduction in the neonatal mortality rate in units under the Unified National Health System (from 19.9 deaths per thousand live births in 1996 to 15.5 in 2000). There was no reduction in the prematurity and low birth weight rates among mothers residing in the municipality of Rio de Janeiro. Analysis of admissions to the NICUs showed a high proportion of neonates born to mothers from municipalities outside Rio de Janeiro, while 14.0% of the mothers had not received prenatal care, and the mortality rate among newborns with birth weight < 1.500g was 32.0%.


The Journal of Pediatrics | 2010

Sepsis and Neutropenia in Very Low Birth Weight Infants Delivered of Mothers with Preeclampsia

Renato S. Procianoy; Rita de Cássia dos Santos Silveira; Marisa M. Mussi-Pinhata; Ligia Maria Suppo de Souza Rugolo; Cléa Rodrigues Leone; José Maria de Andrade Lopes; Maria Fernanda Branco de Almeida

OBJECTIVE To study the association between maternal preeclampsia and neonatal sepsis in very low birth weight newborns. STUDY DESIGN We studied all infants with birth weights between 500 g and 1500 g who were admitted to 6 neonatal intensive care units of the Brazilian Network on Neonatal Research for 2 years. Exclusion criteria were major malformations, death in the delivery room, and maternal chronic hypertension. Absolute neutrophil count was performed in the first 72 hours of life. RESULTS A total of 911 very low birth weight infants (preeclampsia, 308; non-preeclampsia, 603) were included. The preeclampsia group had significantly higher gestational age, more cesarean deliveries, antenatal steroid, central catheters, total parenteral nutrition, and neutropenia, and less rupture of membranes>18 hours and mechanical ventilation. Both groups had similar incidences of early sepsis (4.6% and 4.2% in preeclampsia and non-preeclampsia groups, respectively) and late sepsis (24% and 22.1% in preeclampsia and non- preeclampsia groups, respectively). Vaginal delivery and neutropenia were associated with multiple logistic regressions with early sepsis, and mechanical ventilation, central catheter, and total parenteral nutrition were associated with late sepsis. Death was associated with neutropenia in very preterm infants. CONCLUSIONS Preeclampsia did not increase neonatal sepsis in very low birth weight infants, and death was associated with neutropenia in very preterm infants.


Jornal De Pediatria | 2011

Carga de trabalho de profissionais da saúde e eventos adversos durante ventilação mecânica em unidades de terapia intensiva neonatal

Fernando Lamy Filho; Antonio A. M. Silva; José Maria de Andrade Lopes; Zeni Carvalho Lamy; Vanda Maria Ferreira Simões; Alcione Miranda dos Santos

Objective:To investigate a possible association between the intensity of staff workload and intermediate adverse events, such as accidental extubation, obstruction of the endotracheal tube, and accidental disconnection of the ventilator circuit, during neonatal mechanical ventilation in high-risk neonatal units. Method:This prospective cohort study analyzed data of 543 newborns from public neonatal intensive care units (NICUs) in the city of Sao Luis, state of Maranhao, Northeastern Brazil, for 6 months, during which 136 newborns were submitted to mechanical ventilation in 1,108 shifts and were observed a total of 4,554 times. Results: Adverse events occurred 117 times during this period. The associations between workload and adverse events were analyzed by means of generalized estimating equations. The adjustment variables were: birth weight, gender, maternity unit, Clinical Risk Index for Babies score, and care demand, the latter measured by the Northern Neonatal Network Scale. The larger the number of newborns classified by care demand (NCCD) per nurse and nursing technician, the more likely the occurrence of intermediate adverse events linked to mechanical ventilation. A number of NCCD > 22 per nurse (relative risk [RR] = 2.86) and > 4.8 per auxiliary nurse (RR = 3.41) was associated with a higher prevalence of intermediate adverse events. Conclusions: The workload of NICU professionals seems to interfere with the intermediate results of neonatal care and thus should be taken into consideration when evaluating NICU outcomesOBJECTIVE To investigate a possible association between the intensity of staff workload and intermediate adverse events, such as accidental extubation, obstruction of the endotracheal tube, and accidental disconnection of the ventilator circuit, during neonatal mechanical ventilation in high-risk neonatal units. METHOD This prospective cohort study analyzed data of 543 newborns from public neonatal intensive care units (NICUs) in the city of São Luís, state of Maranhão, Northeastern Brazil, for 6 months, during which 136 newborns were submitted to mechanical ventilation in 1,108 shifts and were observed a total of 4,554 times. RESULTS Adverse events occurred 117 times during this period. The associations between workload and adverse events were analyzed by means of generalized estimating equations. The adjustment variables were: birth weight, gender, maternity unit, Clinical Risk Index for Babies score, and care demand, the latter measured by the Northern Neonatal Network Scale. The larger the number of newborns classified by care demand (NCCD) per nurse and nursing technician, the more likely the occurrence of intermediate adverse events linked to mechanical ventilation. A number of NCCD > 22 per nurse (relative risk [RR] = 2.86) and > 4.8 per auxiliary nurse (RR = 3.41) was associated with a higher prevalence of intermediate adverse events. CONCLUSIONS The workload of NICU professionals seems to interfere with the intermediate results of neonatal care and thus should be taken into consideration when evaluating NICU outcomes.


Jornal De Pediatria | 2007

Efficacy of new microprocessed phototherapy system with five high intensity light emitting diodes (Super LED)

Bianca M. R. Martins; Manoel de Carvalho; Maria Elizabeth Lopes Moreira; José Maria de Andrade Lopes

Objectives: To evaluate the efficacy of a microprocessed phototherapy (PT) system with five high intensity light emitting diodes (Super LED) for the treatment of neonatal hyperbilirubinemia of premature infants.


Sao Paulo Medical Journal | 2003

Lung mechanics and high-resolution computed tomography of the chest in very low birth weight premature infants

Rosane Reis de Mello; Maria Virgínia Peixoto Dutra; José R. M. Ramos; Pedro Daltro; Márcia Boechat; José Maria de Andrade Lopes

CONTEXT Premature infant lung development may be affected by lung injuries during the first few weeks of life. Lung injuries have been associated with changes in lung mechanics. OBJECTIVE To evaluate an association between lung mechanics and lung structural alterations in very low birth weight infants (birth weight less than 1500 g). DESIGN A cross-sectional evaluation of pulmonary mechanics (lung compliance and lung resistance) and high resolution computed tomography of the chest at the time of discharge, in 86 very low birth weight infants born at Instituto Fernandes Figueira, a tertiary public healthcare institution in Rio de Janeiro, Brazil. Lung compliance and resistance were measured during quiet sleep. High resolution computed tomography was performed using Pro Speed-S equipment. MAIN MEASUREMENTS Statistical analysis was performed by means of variance analysis (ANOVA/Kruskal Wallis). The significance level was set at 0.05. RESULTS Abnormal values for both lung compliance and lung resistance were found in 34 babies (43%), whereas 20 (23.3%) had normal values for both lung compliance and lung resistance. The mean lung compliance and lung resistance for the group were respectively 1.30 ml/cm H2O/kg and 63.7 cm H2O/l/s. Lung alterations were found via high-resolution computed tomography in 62 (72%) infants. Most infants showed more than one abnormality, and these were described as ground glass opacity, parenchymal bands, atelectasis and bubble/cyst. The mean compliance values for infants with normal (1.49 ml/cm H2O/kg) high resolution computed tomography, 1 or 2 abnormalities (1.31 ml/cm H2O/kg) and 3 or more abnormalities (1.16 ml/cm H2O/kg) were significantly different (p=0.015). Our data were insufficient to find any association between lung resistance and the number of alterations via high-resolution computed tomography. CONCLUSION The results show high prevalence of lung functional and tomographic abnormalities in asymptomatic very low birth weight infants at the time of discharge. They also show an association between lung morphological and functional abnormalities.


Sao Paulo Medical Journal | 2006

Neonatal risk factors for respiratory morbidity during the first year of life among premature infants

Rosane Reis de Mello; Maria Virgínia Peixoto Dutra; José R. M. Ramos; Pedro Daltro; Márcia Boechat; José Maria de Andrade Lopes

CONTEXT AND OBJECTIVE There have been dramatic increases in very low birth weight infant survival. However, respiratory morbidity remains problematic. The aim here was to verify associations between pulmonary mechanics, pulmonary structural abnormalities and respiratory morbidity during the first year of life. DESIGN AND SETTING Prospective cohort study at Instituto Fernandes Figueira, Fundação Oswaldo Cruz, Rio de Janeiro. METHODS Premature infants with birth weight < 1500 g were studied. Lung function tests and high-resolution chest tomography were performed before discharge. During the first year, infants were assessed for respiratory morbidity (obstructive airways, pneumonia or hospitalization). Neonatal lung tests and chest tomography and covariables potentially associated with respiratory morbidity were independently assessed using relative risk (RR). RR was subsequently adjusted via logistic regression. RESULTS Ninety-seven newborn infants (mean birth weight: 1113 g; mean gestational age: 28 weeks) were assessed. Lung compliance and lung resistance were abnormal in 40% and 59%. Tomography abnormalities were found in 72%; respiratory morbidity in 53%. Bivariate analysis showed respiratory morbidity associated with: mechanical ventilation, prolonged oxygen use (beyond 28 days), oxygen use at 36 weeks, respiratory distress syndrome, neonatal pneumonia and patent ductus arteriosus. Multivariate analysis gave RR 2.7 (confidence interval: 0.7-10.0) for simultaneous lung compliance and chest tomography abnormalities. Adjusted RR for neonatal pneumonia and mechanical ventilation were greater. CONCLUSIONS Upon discharge, there were high rates of lung mechanism and tomography abnormalities. More than 50% presented respiratory morbidity during the first year. Neonatal pneumonia and mechanical ventilation use were statistically significant risk factors.

Collaboration


Dive into the José Maria de Andrade Lopes's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Renato S. Procianoy

Universidade Federal do Rio Grande do Sul

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ruth Guinsburg

Federal University of São Paulo

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jorge Hecker Luz

Pontifícia Universidade Católica do Rio Grande do Sul

View shared research outputs
Researchain Logo
Decentralizing Knowledge