Publication


Featured researches published by Joshua J. Jacobs.


Clinical Orthopaedics and Related Research | 1998

Malrotation causing patellofemoral complications after total knee arthroplasty.

Richard A. Berger; Lawrence S. Crossett; Joshua J. Jacobs; Harry E. Rubash

Thirty patients with isolated patellofemoral complications after total knee arthroplasty were compared with 20 patients with well functioning total knee replacements without patellofemoral complications. The epicondylar axis and tibial tubercle were used as references on computed tomography scans to measure quantitatively rotational alignment of the femoral and tibial components. The group with patellofemoral complications had excessive combined (tibial plus femoral) internal component rotation. This excessive combined internal rotation was directly proportional to the severity of the patellofemoral complication. Small amounts of combined internal rotation (1°-4°) correlated with lateral tracking and patellar tilting. Moderate combined internal rotation (3°-8°) correlated with patellar subluxation. Large amounts of combined internal rotational (7°-17°) correlated with early patellar dislocation or late patellar prosthesis failure. The control group was in combined external rotation (10°-0°). The direct correlation of combined (femoral and tibial) internal component rotation to the severity of the patellofemoral complication suggests that internal component rotation may be the predominant cause of patellofemoral complications in patients with normal axial alignment. The epicondylar axis and tibial tubercle are reproducible landmarks which are visible on computed tomography scans and can be used intraoperatively. Using this computed tomography study can determine whether rotational malalignment is present and thus, whether revision of one or both components may be indicated.


Journal of Bone and Joint Surgery, American Volume | 1998

Current Concepts Review - Corrosion of Metal Orthopaedic Implants

Joshua J. Jacobs; Jeremy L. Gilbert; Robert M. Urban

In situ degradation of metal-alloy implants is undesirable for two reasons: the degradation process may decrease the structural integrity of the implant, and the release of degradation products may elicit an adverse biological reaction in the host. Degradation may result from electrochemical dissolution phenomena, wear, or a synergistic combination of the two. Electrochemical processes may include generalized corrosion, uniformly affecting the entire surface of the implant, and localized corrosion, affecting either regions of the device that are shielded from the tissue fluids (crevice corrosion) or seemingly random sites on the surface (pitting corrosion). Electrochemical and mechanical processes (for example, stress corrosion cracking, corrosion fatigue, and fretting corrosion) may interact, causing premature structural failure and accelerated release of metal particles and ions. The clinical importance of degradation of metal implants is evidenced by particulate corrosion and wear products in tissue surrounding the implant, which may ultimately result in a cascade of events leading to periprosthetic bone loss. Furthermore, many authors have reported increased concentrations of local and systemic trace metal in association with metal implants1,4,5,9-11,14,18,25,26,28,29,47,49-55,58,71,72,75-77,87,90,108-110. There also is a low but finite prevalence of corrosion-related fracture of the implant. This review focuses on electrochemical corrosion phenomena in alloys used for orthopaedic implants. A summary of basic electrochemistry is followed by a discussion of retrieval studies of the response of the implant to the host environment and the response of local tissue to implant corrosion products. The systemic implications of the release of metal particles also are presented. Finally, future directions in biomaterials research and development …


Journal of Bone and Joint Surgery, American Volume | 2001

Metal Sensitivity in Patients with Orthopaedic Implants

Nadim J. Hallab; Katharine Merritt; Joshua J. Jacobs

All metals in contact with biological systems undergo corrosion. This electrochemical process leads to the formation of metal ions, which may activate the immune system by forming complexes with endogenous proteins. Implant degradation products have been shown to be associated with dermatitis, urticaria, and vasculitis. If cutaneous signs of an allergic response appear after implantation of a metal device, metal sensitivity should be considered. Currently, there is no generally accepted test for the clinical determination of metal hypersensitivity to implanted devices. The prevalence of dermal sensitivity in patients with a joint replacement device, particularly those with a failed implant, is substantially higher than that in the general population. Until the roles of delayed hypersensitivity and humoral immune responses to metallic orthopaedic implants are more clearly defined, the risk to patients may be considered minimal. It is currently unclear whether metal sensitivity is a contributing factor to implant failure.


Journal of Bone and Joint Surgery, American Volume | 2000

Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement*

Robert M. Urban; Joshua J. Jacobs; Michael J. Tomlinson; John Gavrilovic; Jonathan Black; Michel Peoc'h

Background: The importance of particles generated by wear and corrosion of joint replacement prostheses has been understood primarily in the context of the local effects of particle-induced periprosthetic osteolysis and aseptic loosening. We studied dissemination of wear particles in patients with total hip and knee replacement to determine the prevalence of and the histopathological response to prosthetic wear debris in the liver, spleen, and abdominal para-aortic lymph nodes. Methods: Postmortem specimens from twenty-nine patients and biopsy specimens from two living patients with a failed replacement were analyzed. Specimens of tissue obtained from the cadavera of fifteen patients who had not had a joint replacement served as controls. The concentration of particles and the associated tissue response were characterized with the use of light microscopy of stained histological sections. Metallic particles were identified by electron microprobe analysis. Polyethylene particles were studied with the use of oil-red-O stain and polarized light microscopy. The composition of polyethylene particles was confirmed in selected cases by Fourier transform infrared spectroscopy and hot-stage thermal analysis. Twenty-one of the patients studied post mortem had had a primary total joint replacement. Eleven of them had had a hip prosthesis for a mean of sixty-nine months (range, forty-three to 171 months), and ten had had a knee replacement for a mean of eighty-four months (range, thirty-one to 179 months). The other eight patients studied post mortem had had a hip replacement in which one or more components had loosened and had been revised. The mean time between the initial arthroplasty and the time of death was 174 months (range, forty-seven to 292 months), and the mean time between the last revision procedure and the time of death was seventy-one months (range, one to 130 months). Results: Metallic wear particles in the liver or spleen were more prevalent in patients who had had a failed hip arthroplasty (seven of eight) than in patients who had had a primary hip (two of eleven) or knee replacement (two of ten). The principal source of wear particles in the majority of these patients involved secondary nonbearing surfaces rather than wear between the two primary bearing surfaces as intended. In one living patient, dissemination of titanium alloy particles from a hip prosthesis with mechanical failure was associated with a visceral granulomatous reaction and hepatosplenomegaly, which required operative and medical treatment. Metallic wear particles were detected in the para-aortic lymph nodes in 68 percent (nineteen) of the twenty-eight patients with an implant from whom lymph nodes were available for study. In 38 percent (eleven) of all twenty-nine patients with an implant who were studied post mortem, metallic particles had been further disseminated to the liver or spleen, where they were usually found within small aggregates of macrophages occurring as infiltrates without apparent pathological importance. Polyethylene particles elicited a similar response. They were identified in the para-aortic lymph nodes of 68 percent (nineteen) of the twenty-eight patients and the liver or spleen of 14 percent (four) of the twenty-nine patients. The majority of the disseminated wear particles were less than one micrometer in size. Currently available methods lack the sensitivity and specificity necessary to detect very low concentrations of submicrometer polyethylene particles and probably underestimated the prevalence of polyethylene wear debris in the liver and spleen. Conclusions: In this study, systemic distribution of metallic and polyethylene wear particles was a common finding, both in patients with a previously failed implant and in those with a primary total joint prosthesis. The prevalence of particles in the liver or spleen was greater after reconstructions with mechanical failure. In the majority of patients, the concentration of wear particles in these organs was relatively low and without apparent pathological importance. However, in one rare case, granulomas formed in the liver, spleen, and abdominal lymph nodes in response to heavy accumulation of wear debris from a hip prosthesis with mechanical failure and compromised hepatic function. Clinical Relevance: These findings underscore the necessity of minimizing the production of particulate debris by joint replacement devices and the need for the surgeon to consider expeditious revision in patients in whom large amounts of particulate debris may be generated. Serum and urine trace-metal analyses may provide early confirmation of failure and aid in the timing of a revision operation in a patient with a symptomatic or failed device.


Journal of Bone and Joint Surgery, American Volume | 1998

Metal release in patients who have had a primary total hip arthroplasty a prospective, controlled, longitudinal study

Joshua J. Jacobs; Anastasia K. Skipor; Leslie M. Patterson; Nadim J. Hallab; Wayne G. Paprosky; Jonathan Black; Jorge O. Galante

There is an increasing recognition that, in the long term, total joint replacement may be associated with adverse local and remote tissue responses that are mediated by the degradation products of prosthetic materials. Particular interest has centered on the metal-degradation products of total joint replacements because of the known toxicities of the metal elements that make up the alloys used in the implants. We measured the concentrations of titanium, aluminum, cobalt, and chromium in the serum and the concentration of chromium in the urine of seventy-five patients during a three-year prospective, longitudinal study. Twenty patients had had a so-called hybrid total hip replacement (insertion of a modular cobalt-alloy femoral stem and head with cement and a titanium acetabular cup without cement), fifteen had had insertion of an extensively porous-coated cobalt-alloy stem with a cobalt-alloy head and a titanium-alloy socket without cement, and twenty had had insertion of a proximally porous-coated titanium-alloy stem with a cobalt-alloy head and a titanium socket without cement. The remaining twenty patients did not have an implant and served as controls. The results of our study showed that, thirty-six months postoperatively, patients who have a well functioning prosthesis with components containing titanium have as much as a threefold increase in the concentration of titanium in the serum and those who have a well functioning prosthesis with cobalt-alloy components have as much as a fivefold and an eightfold increase in the concentrations of chromium in the serum and urine, respectively. The predominant source of the disseminated chromium-degradation products is probably the modular head-neck junction and may be a function of the geometry of the coupling. Passive dissolution of extensively porous-coated cobalt-alloy stems was not found to be a dominant mode of metal release. CLINICAL RELEVANCE: Increased concentrations of circulating metal-degradation products derived from orthopaedic implants may have deleterious biological effects over the long term that warrant investigation. This is a particularly timely concern because of recent clinical trends, including the reintroduction of metal-on-metal bearing surfaces and the increasing popularity of extensively porous-coated devices with large surface areas of exposed metal. Accurate monitoring of the concentrations of metal in the serum and urine after total hip replacement also can provide insights into the mechanisms of metal release. Our findings suggest that fretting corrosion at the head-neck coupling is an important source of metal release that can lead to increased concentrations of chromium in the serum. Determinations of the concentrations of metal in the serum and urine may be useful in the diagnosis of patients who are symptomatic after a total joint replacement as increased levels are indicative of at least one mode of mechanical dysfunction (for example, fretting corrosion) of the device.


The Journal of Neuroscience | 2009

Broadband Shifts in Local Field Potential Power Spectra Are Correlated with Single-Neuron Spiking in Humans

Jeremy R. Manning; Joshua J. Jacobs; Itzhak Fried; Michael J. Kahana

A fundamental question in neuroscience concerns the relation between the spiking of individual neurons and the aggregate electrical activity of neuronal ensembles as seen in local field potentials (LFPs). Because LFPs reflect both spiking activity and subthreshold events, this question is not simply one of data aggregation. Recording from 20 neurosurgical patients, we directly examined the relation between LFPs and neuronal spiking. Examining 2030 neurons in widespread brain regions, we found that firing rates were positively correlated with broadband (2–150 Hz) shifts in the LFP power spectrum. In contrast, narrowband oscillations correlated both positively and negatively with firing rates at different recording sites. Broadband power shifts were a more reliable predictor of neuronal spiking than narrowband power shifts. These findings suggest that broadband LFP power provides valuable information concerning neuronal activity beyond that contained in narrowband oscillations.


Journal of Bone and Joint Surgery, American Volume | 2012

Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip Arthroplasty

H. John Cooper; Craig J. Della Valle; Richard A. Berger; Matthew W. Tetreault; Wayne G. Paprosky; Scott M. Sporer; Joshua J. Jacobs

BACKGROUND Corrosion at the modular head-neck junction of the femoral component in total hip arthroplasty has been identified as a potential concern, although symptomatic adverse local tissue reactions secondary to corrosion have rarely been described. METHODS We retrospectively reviewed the records of ten patients with a metal-on-polyethylene total hip prosthesis, from three different manufacturers, who underwent revision surgery for corrosion at the modular head-neck junction. RESULTS All patients presented with pain or swelling around the hip, and two patients presented with recurrent instability. Serum cobalt levels were elevated prior to the revision arthroplasty and were typically more elevated than were serum chromium levels. Surgical findings included large soft-tissue masses and surrounding tissue damage with visible corrosion at the femoral head-neck junction; the two patients who presented with instability had severe damage to the hip abductor musculature. Pathology specimens consistently demonstrated areas of tissue necrosis. The patients were treated with debridement and a femoral head and liner exchange, with use of a ceramic femoral head with a titanium sleeve in eight cases. The mean Harris hip score improved from 58.1 points preoperatively to 89.7 points at a mean of 13.0 months after the revision surgery (p=0.01). Repeat serum cobalt levels, measured in six patients at a mean of 8.0 months following revision, decreased to a mean of 1.61 ng/mL, and chromium levels were similar to prerevision levels. One patient with moderate hip abductor muscle necrosis developed recurrent instability after revision and required a second revision arthroplasty. CONCLUSIONS Adverse local tissue reactions can occur in patients with a metal-on-polyethylene bearing secondary to corrosion at the modular femoral head-neck taper, and their presentation is similar to the adverse local tissue reactions seen in patients with a metal-on-metal bearing. Elevated serum metal levels, particularly a differential elevation of serum cobalt levels with respect to chromium levels, can be helpful in establishing this diagnosis.


Clinical Orthopaedics and Related Research | 2002

A multicenter retrieval study of the taper interfaces of modular hip prostheses

Jay R. Goldberg; Jeremy L. Gilbert; Joshua J. Jacobs; Thomas W. Bauer; Wayne G. Paprosky; Sue Leurgans

A multicenter retrieval analysis of 231 modular hip implants was done to investigate the effects of material combination, metallurgic condition, flexural rigidity, head and neck moment arm, neck length, and implantation time on corrosion and fretting of modular taper surfaces. Scores for corrosion and fretting were assigned to medial, lateral, anterior, and posterior quadrants of the necks, and proximal and distal regions of the heads. Neck and head corrosion and fretting scores were found to be significantly higher for mixed alloy versus similar alloy couples. Moderate to severe corrosion was observed in 28% of the heads of similar alloy couples and 42% of the heads of mixed alloy couples. Differences in corrosion scores were observed between components made from the same base alloy, but of different metallurgic conditions. Corrosion and fretting scores tended to be higher for heads than necks. Implantation time and flexural rigidity of the neck were predictors of head and neck corrosion and head fretting. The results of this study suggest that in vivo corrosion of modular hip taper interfaces is attributable to a mechanically-assisted crevice corrosion process. Larger diameter necks will increase neck stiffness and may reduce fretting and subsequent corrosion of the taper interface regardless of the alloy used. Increasing neck diameter must be balanced, however, with the resulting loss of range of motion and joint stability.


Tissue Engineering | 2001

Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion.

Nadim J. Hallab; Kirk J. Bundy; Kim C. O'Connor; Randy L. Moses; Joshua J. Jacobs

Directed cell adhesion remains an important goal of implant and tissue engineering technology. In this study, surface energy and surface roughness were investigated to ascertain which of these properties show more overall influence on biomaterial-cell adhesion and colonization. Jet impingement was used to quantify cellular adhesion strength. Cellular proliferation and extracellular matrix secretion were used to characterize colonization of 3T3MC fibroblasts on: HS25 (a cobalt based implant alloy, ASTM F75), 316L stainless steel, Ti-6Al4V (a titanium implant alloy), commercially pure tantalum (Ta), polytetrafluoroethylene (PTFE), silicone rubber (SR), and high-density polyethylene (HDPE). The metals exhibited a nearly five-fold greater adhesion strength than the polymeric materials tested. Generally, surface energy was proportional to cellular adhesion strength. Only polymeric materials demonstrated significant increased adhesion strength associated with increased surface roughness. Cellular adhesion on metals demonstrated a linear correlation with surface energy. Less than half as much cellular proliferation was detected on polymeric materials compared to the metals. However the polymers tested demonstrated greater than twice the amount of secreted extracellular matrix (ECM) proteins on a per cell basis than the metallic materials. Thus, surface energy may be a more important determinant of cell adhesion and proliferation, and may be more useful than surface roughness for directing cell adhesion and cell colonization onto engineered tissue scaffoldings.


Clinical Orthopaedics and Related Research | 1996

Cobalt and chromium concentrations in patients with metal on metal total hip replacements.

Joshua J. Jacobs; Anastasia K. Skipor; Peter F. Doorn; Pat Campbell; Thomas P. Schmalzried; Jonathan Black; Harlan C. Amstutz

There has been a resurgence of interest in the use of metal on metal bearings in total hip arthroplasty. Although the use of metal on metal bearing couples would eliminate or substantially reduce particulate polyethylene generation (depending on the presence or absence of polyethylene in the implant system), there is concern about the potential for increased particulate and ionic metal generation in comparison with polyethylene on metal bearings. These metallic degradation products may be transported away from the implant site and distributed systemically. Chromium concentrations in the serum and urine and cobalt concentrations in the serum were measured in subjects with cobalt chromium alloy metal on metal total hip replacements and in controls without implants. Eight subjects with long term (> 20 years) McKee-Farrar total hip replacements had 9-fold elevations in serum chromium, 35-fold elevations in urine chromium, and at least 3-fold elevations in serum cobalt concentrations in comparison with controls. Six subjects with short term (< 2 years) metal on metal surface replacement arthroplasties had 3-fold elevations in serum chromium, 4-fold elevations in urine chromium, and 4-fold elevations in serum cobalt concentrations in comparison with subjects with McKee-Farrar implants. Although the toxicologic importance of these trace metal elevations has not been established, serum and urine metal concentrations may be useful markers for the tribologic performance of metal on metal bearings.

Collaboration


Dive into the Joshua J. Jacobs's collaboration.

Top Co-Authors

Avatar

Jorge O. Galante

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Nadim J. Hallab

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Aaron G. Rosenberg

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Richard A. Berger

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Anastasia K. Skipor

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Robert M. Urban

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Craig J. Della Valle

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Markus A. Wimmer

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Tibor T. Glant

Rush University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge