Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Juergen F. Kolb is active.

Publication


Featured researches published by Juergen F. Kolb.


Proceedings of the IEEE | 2004

Ultrashort electrical pulses open a new gateway into biological cells

Karl H. Schoenbach; R. P. Joshi; Juergen F. Kolb; Nianyong Chen; Michael W. Stacey; Peter F. Blackmore; E.S. Buescher; Stephen J. Beebe

An electrical model for biological cells predicts that for pulses with durations shorter than the charging time of the outer membrane, there is an increasing probability of electric field interactions with intracellular structures. Experimental studies in which human cells were exposed to pulsed electric fields of up to 300-kV/cm amplitude, with durations as short as 10 ns, have confirmed this hypothesis. The observed effects include the breaching of intracellular granule membranes without permanent damage to the cell membrane, abrupt rises in intracellular free calcium levels, and enhanced expression of genes. At increased electric fields, the application of submicrosecond pulses induces apoptosis (programmed cell death) in biological cells, an effect that has been shown to reduce the growth of tumors. Possible applications of the intracellular electroeffect are enhancing gene delivery to the nucleus, controlling cell functions that depend on calcium release (causing cell immobilization), and treating tumors.


Applied Physics Letters | 2008

Cold atmospheric pressure air plasma jet for medical applications

Juergen F. Kolb; Abdel-Aleam H. Mohamed; R. O. Price; R.J. Swanson; Angela M. Bowman; R. L. Chiavarini; Michael W. Stacey; Karl H. Schoenbach

By flowing atmospheric pressure air through a direct current powered microhollow cathode discharge, we were able to generate a 2cm long plasma jet. With increasing flow rate, the flow becomes turbulent and temperatures of the jet are reduced to values close to room temperature. Utilizing the jet, yeast grown on agar can be eradicated with a treatment of only a few seconds. Conversely, animal studies show no skin damage even with exposures ten times longer than needed for pathogen extermination. This cold plasma jet provides an effective mode of treatment for yeast infections of the skin.


International Journal of Cancer | 2009

A new pulsed electric field therapy for melanoma disrupts the tumor's blood supply and causes complete remission without recurrence

Richard Nuccitelli; Xinhua Chen; Andrei G. Pakhomov; Wallace H. Baldwin; Saleh Sheikh; Jennifer L. Pomicter; Wei Ren; Christopher Osgood; R. James Swanson; Juergen F. Kolb; Stephen J. Beebe; Karl H. Schoenbach

We have discovered a new, ultrafast therapy for treating skin cancer that is extremely effective with a total electric field exposure time of only 180 μsec. The application of 300 high‐voltage (40 kV/cm), ultrashort (300 nsec) electrical pulses to murine melanomas in vivo triggers both necrosis and apoptosis, resulting in complete tumor remission within an average of 47 days in the 17 animals treated. None of these melanomas recurred during a 4‐month period after the initial melanoma had disappeared. These pulses generate small, long‐lasting, rectifying nanopores in the plasma membrane of exposed cells, resulting in increased membrane permeability to small molecules and ions, as well as an increase in intracellular Ca2+, DNA fragmentation, disruption of the tumors blood supply and the initiation of apoptosis. Apoptosis was indicated by a 3‐fold increase in Bad labeling and a 72% decrease in Bcl‐2 labeling. In addition, microvessel density within the treated tumors fell by 93%. This new therapy utilizing nanosecond pulsed electric fields has the advantages of highly localized targeting of tumor cells and a total exposure time of only 180 μsec. These pulses penetrate into the interior of every tumor cell and initiate DNA fragmentation and apoptosis while at the same time reducing blood flow to the tumor. This new physical tumor therapy is drug free, highly localized, uses low energy, has no significant side effects and results in very little scarring.


Journal of Physics D | 2008

Streamers in water and other dielectric liquids

Juergen F. Kolb; R. P. Joshi; Shu Xiao; Karl H. Schoenbach

Experimental results on the inception and propagation of streamers in water generated under the application of high electric fields are reviewed. Characteristic parameters, such as breakdown voltage, polarity of the applied voltage, propagation velocities and other phenomenological features, are compared with similar phenomena in other dielectric liquids and in gases. Consequently, parameters that are expected to influence the development of streamers in water are discussed with respect to the analogous well-established models and theories for the related mechanisms in gases. Most of the data support the notion that an initial low-density nucleation site or gas-filled bubble assists the initiation of a streamer. Details of this theory are laid out explaining the observed differences in the breakdown originating from the anode versus the cathode locations. The mechanisms can also be applied to streamer propagation, although some observations cannot be satisfactorily explained.


Plasma Sources Science and Technology | 2016

Plasma–liquid interactions: a review and roadmap

Pj Peter Bruggeman; Mark J. Kushner; Bruce R. Locke; Jge Gardeniers; W. G. Graham; David B. Graves; Rchm Hofman-Caris; D Marić; Jonathan P. Reid; E Ceriani; D. Fernandez Rivas; John E. Foster; Sc Garrick; Yury Gorbanev; Satoshi Hamaguchi; Felipe Iza; Helena Jablonowski; Juergen F. Kolb; František Krčma; Petr Lukes; Zdenko Machala; I. Marinov; Davide Mariotti; S. Mededovic Thagard; D. Minakata; Erik C. Neyts; J. Pawlat; Z. Lj. Petrović; R. Pflieger; Stephan Reuter

Plasma–liquid interactions represent a growing interdisciplinary area of research involving plasma science, fluid dynamics, heat and mass transfer, photolysis, multiphase chemistry and aerosol science. This review provides an assessment of the state-of-the-art of this multidisciplinary area and identifies the key research challenges. The developments in diagnostics, modeling and further extensions of cross section and reaction rate databases that are necessary to address these challenges are discussed. The review focusses on non-equilibrium plasmas.


IEEE Transactions on Plasma Science | 2008

The Effect of Intense Subnanosecond Electrical Pulses on Biological Cells

Karl H. Schoenbach; Shu Xiao; R. P. Joshi; J.T. Camp; Tammo Heeren; Juergen F. Kolb; Stephen J. Beebe

Nanosecond electrical pulses have been successfully used to treat melanoma tumors by using needle arrays as pulse delivery systems. Reducing the pulse duration of intense electric field pulses from nanoseconds into the subnanosecond range will allow us to use wideband antennas to deliver the electromagnetic fields into tissue with a spatial resolution in the centimeter range. To explore the biological effect of intense subnanosecond pulses, we have developed a generator that provides voltage pulses of 160 kV amplitude, 200 ps rise time, and 800 ps pulse width. The pulses are delivered to a cylindrical Teflon chamber with polished flat electrodes at either end. The distance between the electrodes is variable and allows us to generate electric fields of up to 1 MV/cm in cell suspensions. The pulses have been applied to B16 (murine melanoma) cells, and the plasma membrane integrity was studied by means of trypan blue exclusion. For pulse amplitudes of 550 kV/cm, approximately 50% of the cells took up trypan blue right after pulsing, whereas only 20% were taking it up after 1 h. This indicates that the plasma membrane in a majority of the cells affected by the pulses recovers with a time constant of about 1 h. The cells that show trypan blue uptake after this time suffer cell death through apoptosis. Evaluation of the experimental results and molecular dynamics modeling results indicate that with a pulse duration of 800 ps, membrane charging and nanopore formation are the dominant bioelectric effects on B16 cells. This information has been used in a continuum model to estimate the increase in membrane permeability and, consequently, the increase in pore size caused by repetitive pulsing.


Pigment Cell & Melanoma Research | 2010

Apoptosis initiation and angiogenesis inhibition: melanoma targets for nanosecond pulsed electric fields

Xinhua Chen; Juergen F. Kolb; R. James Swanson; Karl H. Schoenbach; Stephen J. Beebe

Many effective anti‐cancer strategies target apoptosis and angiogenesis mechanisms. Applications of non‐ionizing, nanosecond pulsed electric fields (nsPEFs) induce apoptosis in vitro and eliminate cancer in vivo; however in vivo mechanisms require closer analysis. These studies investigate nsPEF‐induced apoptosis and anti‐angiogenesis examined by fluorescent microscopy, immunoblots, and morphology. Six hours after treatment with one hundred 300 ns pulses at 40 kV/cm, cells transiently expressed active caspases indicating that caspase‐mediated mechanisms. Three hours after treatment transient peaks in Histone 2AX phosphorylation coincided with terminal deoxynucleotidyl transferase dUTP nick end labeling positive cells and pyknotic nuclei, suggesting caspase‐independent mechanisms on nuclei/DNA. Large DNA fragments, but not 180 bp fragmentation ladders, were observed, suggesting incomplete apoptosis. Nevertheless, tumor weight and volume decreased and tumors disappeared. One week after treatment, vessel numbers, vascular endothelial growth factor (VEGF), platelet derived endothelial cell growth factor (PD‐ECGF), CD31, CD35 and CD105 were decreased, indicating anti‐angiogenesis. The nsPEFs activate multiple melanoma therapeutic targets, which is consistent with successes of nsPEF applications for tumor treatment in vivo as a new cancer therapeutic modality.


Biochimica et Biophysica Acta | 2009

Regulation of intracellular calcium concentration by nanosecond pulsed electric fields

Shaka S. Scarlett; Jody A. White; Peter F. Blackmore; Karl H. Schoenbach; Juergen F. Kolb

Changes in [Ca(2+)](i) response of individual Jurkat cells to nanosecond pulsed electric fields (nsPEFs) of 60 ns and field strengths of 25, 50, and 100 kV/cm were investigated. The magnitude of the nsPEF-induced rise in [Ca(2+)](i) was dependent on the electric field strength. With 25 and 50 kV/cm, the [Ca(2+)](i) response was due to the release of Ca(2+) from intracellular stores and occurred in less than 18 ms. With 100 kV/cm, the increase in [Ca(2+)](i) was due to both internal release and to influx across the plasma membrane. Spontaneous changes in [Ca(2+)](i) exhibited a more gradual increase over several seconds. The initial, pulse-induced [Ca(2+)](i) response initiates at the poles of the cell with respect to electrode placement and co-localizes with the endoplasmic reticulum. The results suggest that nsPEFs target both the plasma membrane and subcellular membranes and that one of the mechanisms for Ca(2+) release may be due to nanopore formation in the endoplasmic reticulum.


IEEE Transactions on Plasma Science | 2004

Characterization of the cytotoxic effect of high-intensity, 10-ns duration electrical pulses

Andrei G. Pakhomov; Amy Phinney; John Ashmore; Kerfoot Walker; Juergen F. Kolb; S. Kono; Karl H. Schoenbach; Michael R. Murphy

Cytotoxic effects of 10-ns electrical pulses (EP, 50-380 kV/cm) were analyzed in cultured U937 cells (human lymphoma). Densities of live and dead cells were compared in over 500 samples at intervals from 0.5 to 48 h post exposure. EP trains of 1-20 pulses caused a minor, if any, decrease in cell survival: 24 h post exposure, the density of live cells typically dropped just 10-20% compared with unexposed parallel control. Within studied limits, this effect did not significantly depend on the EP number, voltage, or repetition rate. However, much longer EP trains could cause a sharp survival decline. The transition from plateau to profound cell killing occurred at about 150 pulses at 150 kV/cm, and at over 1000 pulses at 50 kV/cm. Artifact-free thermometry using a fiber optic microprobe established unequivocally that cell killing by extra-long EP trains was not a result of sample heating and has to be explained by other mechanisms. Testing for specific apoptotic cleavage of poly(ADP-ribose) polymerase at scattered time intervals (1-24 h) after EP exposure produced mostly negative results. Overall, 10-ns EP caused far weaker cytotoxic effect than it was reported earlier from experiments in other cell lines and mostly with longer pulses (60 and 300 ns). The survival curve shape (i.e., the shoulder followed by exponential decline) is also characteristic for other cytotoxic factors, such as low-LET ionizing radiation, thereby possibly pointing to common mechanisms or targets.


Biochemical and Biophysical Research Communications | 2007

Ultrashort electric pulse induced changes in cellular dielectric properties

Allen L. Garner; George Chen; Nianyong Chen; V. Sridhara; Juergen F. Kolb; R. James Swanson; Stephen J. Beebe; R. P. Joshi; Karl H. Schoenbach

The interaction of nanosecond duration pulsed electric fields (nsPEFs) with biological cells, and the models describing this behavior, depend critically on the electrical properties of the cells being pulsed. Here, we used time domain dielectric spectroscopy to measure the dielectric properties of Jurkat cells, a malignant human T-cell line, before and after exposure to five 10ns, 150kV/cm electrical pulses. The cytoplasm and nucleoplasm conductivities decreased dramatically following pulsing, corresponding to previously observed rises in cell suspension conductivity. This suggests that electropermeabilization occurred, resulting in ion transport from the cells interior to the exterior. A delayed decrease in cell membrane conductivity after the nsPEFs possibly suggests long-term ion channel damage or use dependence due to repeated membrane charging and discharging. This data could be used in models describing the phenomena at work.

Collaboration


Dive into the Juergen F. Kolb's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

R. P. Joshi

Old Dominion University

View shared research outputs
Top Co-Authors

Avatar

Shu Xiao

Old Dominion University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Xinpei Lu

Huazhong University of Science and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge