Julia W. Evans
University of California, Davis
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Julia W. Evans.
Proceedings of SPIE | 2006
Bruce A. Macintosh; James R. Graham; David Palmer; René Doyon; Donald Gavel; James E. Larkin; Ben R. Oppenheimer; Leslie Saddlemyer; J. Kent Wallace; Brian J. Bauman; Julia W. Evans; Darren Erikson; Katie M. Morzinski; D. W. Phillion; Lisa A. Poyneer; Anand Sivaramakrishnan; Rémi Soummer; Simon Thibault; Jean-Pierre Véran
The next major frontier in the study of extrasolar planets is direct imaging detection of the planets themselves. With high-order adaptive optics, careful system design, and advanced coronagraphy, it is possible for an AO system on a 8-m class telescope to achieve contrast levels of 10-7 to 10-8, sufficient to detect warm self-luminous Jovian planets in the solar neighborhood. Such direct detection is sensitive to planets inaccessible to current radial-velocity surveys and allows spectral characterization of the planets, shedding light on planet formation and the structure of other solar systems. We have begun the construction of such a system for the Gemini Observatory. Dubbed the Gemini Planet Imager (GPI), this instrument should be deployed in 2010 on the Gemini South telescope. It combines a 2000-actuator MEMS-based AO system, an apodized-pupil Lyot coronagraph, a precision infrared interferometer for real-time wavefront calibration at the nanometer level, and a infrared integral field spectrograph for detection and characterization of the target planets. GPI will be able to achieve Strehl ratios > 0.9 at 1.65 microns and to observe a broad sample of science targets with I band magnitudes less than 8. In addition to planet detection, GPI will also be capable of polarimetric imaging of circumstellar dust disks, studies of evolved stars, and high-Strehl imaging spectroscopy of bright targets. We present here an overview of the GPI instrument design, an error budget highlighting key technological challenges, and models of the system performance.
Optics Express | 2009
Robert J. Zawadzki; Stacey S. Choi; Alfred R. Fuller; Julia W. Evans; Bernd Hamann; John S. Werner
Ultrahigh-resolution adaptive optics-optical coherence tomography (UHR-AO-OCT) instrumentation allowing monochromatic and chromatic aberration correction was used for volumetric in vivo retinal imaging of various retinal structures including the macula and optic nerve head (ONH). Novel visualization methods that simplify AO-OCT data viewing are presented, and include co-registration of AO-OCT volumes with fundus photography and stitching of multiple AO-OCT sub-volumes to create a large field of view (FOV) high-resolution volume. Additionally, we explored the utility of Interactive Science Publishing by linking all presented AO-OCT datasets with the OSA ISP software.
Optics Letters | 2008
Michael Pircher; Robert J. Zawadzki; Julia W. Evans; John S. Werner; Christoph K. Hitzenberger
We describe a novel instrument capable of acquiring, simultaneously, adaptive optics enhanced scanning laser ophthalmoscopy and optical coherence tomography (OCT) images of the human cone mosaic in vivo. The OCT system is based on transversal scanning of the sample with a line scan rate of 14 kHz, approximately 20 times faster than a previously reported instrument. We demonstrate the capability of this instrument with the measurement of the human cone spacing in perifoveal retina.
Optics Express | 2006
Julia W. Evans; Bruce A. Macintosh; Lisa A. Poyneer; Katie Morzinski; Scott A. Severson; Daren Dillon; Donald T. Gavel; Layra Reza
Ground based high-contrast imaging (e.g. extrasolar giant planet detection) has demanding wavefront control requirements two orders of magnitude more precise than standard adaptive optics systems. We demonstrate that these requirements can be achieved with a 1024-Micro-Electrical-Mechanical-Systems (MEMS) deformable mirror having an actuator spacing of 340 microm and a stroke of approximately 1 microm, over an active aperture 27 actuators across. We have flattened the mirror to a residual wavefront error of 0.54 nm rms within the range of controllable spatial frequencies. Individual contributors to final wavefront quality, such as voltage response and uniformity, have been identified and characterized.
Journal of Vision | 2009
Sarah L. Elliott; Stacey S. Choi; Nathan Doble; Joseph L. Hardy; Julia W. Evans; John S. Werner
The contributions of optical and neural factors to age-related losses in spatial vision are not fully understood. We used closed-loop adaptive optics to test the visual benefit of correcting monochromatic high-order aberrations (HOAs) on spatial vision for observers ranging in age from 18 to 81 years. Contrast sensitivity was measured monocularly using a two-alternative forced-choice (2AFC) procedure for sinusoidal gratings over 6 mm and 3 mm pupil diameters. Visual acuity was measured using a spatial 4AFC procedure. Over a 6 mm pupil, young observers showed a large benefit of AO at high spatial frequencies, whereas older observers exhibited the greatest benefit at middle spatial frequencies, plus a significantly larger increase in visual acuity. When age-related miosis is controlled, young and old observers exhibited a similar benefit of AO for spatial vision. An increase in HOAs cannot account for the complete senescent decline in spatial vision. These results may indicate a larger role of additional optical factors when the impact of HOAs is removed, but also lend support for the importance of neural factors in age-related changes in spatial vision.
Journal of Biophotonics | 2009
Julia W. Evans; Robert J. Zawadzki; Rui Liu; James W. Chan; Stephen M. Lane; John S. Werner
Imaging the structure and correlating it with the biochemical content of the retina holds promise for fundamental research and for clinical applications. Optical coherence tomography (OCT) is commonly used to image the 3D structure of the retina and while the added functionality of biochemical analysis afforded by Raman scattering could provide critical molecular signatures for clinicians and researchers, there are many technical challenges to combine these imaging modalities. We describe an OCT microscope for ex-vivo imaging combined with Raman spectroscopy capable of collecting morphological and molecular information about a sample simultaneously. We present our first results and discuss the challenges to further development of this dual-mode instrument and limitations for future in-vivo retinal imaging.
Optics Express | 2009
Julia W. Evans; Robert J. Zawadzki; Steven M. Jones; Scot S. Olivier; John S. Werner
The combination of adaptive optics (AO) technology with optical coherence tomography (OCT) instrumentation for imaging the retina has proven to be a valuable tool for clinicians and researchers in understanding the healthy and diseased eye. The micrometer-isotropic resolution achieved by such a system allows imaging of the retina at a cellular level, however imaging of some cell types remains elusive. Improvement in contrast rather than resolution is needed and can be achieved through better AO correction of wavefront aberration. A common tool for assessing and ultimately improving AO system performance is the development of an error budget. Specifically, this is a list of the magnitude of the constituent residual errors of an optical system so that resources can be directed towards efficient performance improvement. Here we present an error budget developed for the UC Davis AO-OCT instrument indicating that bandwidth and controller errors are the limiting errors of our AO system, which should be corrected first to improve performance. We also discuss the scaling of error sources for different subjects and the need to improve the robustness of the system by addressing subject variability.
Proceedings of SPIE, the International Society for Optical Engineering | 2006
Julia W. Evans; Katie M. Morzinski; Scott A. Severson; Lisa A. Poyneer; Bruce A. Macintosh; Daren Dillon; Layra Reza; Donald Gavel; David Palmer; Scot S. Olivier; Paul A. Bierden
We have demonstrated that a microelectrical mechanical systems (MEMS) deformable mirror can be flattened to < 1 nm RMS within controllable spatial frequencies over a 9.2-mm aperture making it a viable option for high-contrast adaptive optics systems (also known as Extreme Adaptive Optics). The Extreme Adaptive Optics Testbed at UC Santa Cruz is being used to investigate and develop technologies for high-contrast imaging, especially wavefront control. A phase shifting diffraction interferometer (PSDI) measures wavefront errors with sub-nm precision and accuracy for metrology and wavefront control. Consistent flattening, required testing and characterization of the individual actuator response, including the effects of dead and low-response actuators. Stability and repeatability of the MEMS devices was also tested. An error budget for MEMS closed loop performance will summarize MEMS characterization.
Optics Letters | 2006
Julia W. Evans; Gary E. Sommargren; Bruce A. Macintosh; Scott A. Severson; Daren Dillon
Received October 11, 2005; accepted November 10, 2005; posted December 2, 2005 (Doc. ID 65234) We have measured a contrast of 6.5 x 10(-8) from 10 to 25 lambda/D in visible light on the Extreme Adaptive Optics testbed, using a shaped pupil for diffraction suppression. The testbed was designed with a minimal number of high-quality optics to ensure low wavefront error and uses a phase-shifting diffraction interferometer for metrology. This level of contrast is within the regime needed for imaging young Jupiter-like planets, a primary application of high-contrast imaging. We have concluded that wavefront error, not pupil quality, is the limiting error source for improved contrast in our system.
Proceedings of SPIE | 2006
Scott A. Severson; Brian J. Bauman; Daren Dillon; Julia W. Evans; Donald Gavel; Bruce A. Macintosh; Katie M. Morzinski; Dave Palmer; Lisa A. Poyneer
We present a summary of our current results from the Extreme Adaptive Optics (ExAO) Testbed and the design and status of its coronagraphic upgrade. The ExAO Testbed at the Laboratory for Adaptive Optics at UCO/Lick Observatory is optimized for ultra-high contrast applications requiring high-order wavefront control. It is being used to investigate and develop technologies for the Gemini Planet Imager (GPI). The testbed is equipped with a phase shifting diffraction interferometer (PSDI), which measures the wavefront with sub-nm precision and accuracy. The testbed also includes a 1024-actuator Micro Electro Mechanical Systems (MEMS) deformable mirror manufactured by Boston Micromachines. We present a summary of the current results with the testbed encompassing MEMS flattening via PSDI, MEMS flattening via a Shack-Hartmann wavefront sensor (with and without spatial filtering), the introduction of Kolmogorov phase screens, and contrast in the far-field. Upgrades in progress include adding additional focal and pupil planes to better control scattered light and allow alternative coronagraph architectures, the introduction and testing of high-quality reflecting optics, and a variety of input phase aberrations. Ultimately, the system will serve as a full prototype for GPI.