Drug Development and Industrial Pharmacy | 2003

Influence of the Metering Chamber Volume and Actuator Design on the Aerodynamic Particle Size of a Metered Dose Inhaler

Julianne Berry; Susan K. Heimbecher; John L. Hart; Joel A. Sequeira

Abstract Presented in this work are the results of a study designed to investigate the impact of the valve metering chamber volume and actuator design on the aerodynamic particle size distribution (PSD) of a suspension metered dose inhaler (MDI) containing propellant HFA-227. It was hypothesized that the valve metering volume and the actuator design in the MDI could influence the PSD of the emitted dose since it would affect the aerosol spray dynamics. The PSD results from this study, measured using cascade impaction, revealed that samples containing an actuator intended for oral delivery (rectangular mouthpiece and orifice diameter of ≈0.5 mm) produced a higher fine particle dose (FPD) than those containing an actuator intended for nasal delivery (circular nosetip and orifice diameter of ≈1 mm). In addition, the drug PSD profile was shown to be more sensitive to differences in the particle size of the suspended material when the oral actuator was used compared to when the nasal actuator was used. The valve metering chamber (25 vs. 63 μL volume) did not appear to have a major effect on the product aerodynamic PSD or the droplet size. These results demonstrate the importance of actuator design and orifice size in determining the aerodynamic PSD of an MDI.


Drug Development and Industrial Pharmacy | 2003

Influence of the Storage Orientation on the Aerodynamic Particle Size of a Suspension Metered Dose Inhaler Containing Propellant HFA-227

Julianne Berry; Lukeysha C. Kline; John L. Hart; Joel A. Sequeira

Abstract Presented in this work are the results of a study designed to investigate the impact of the storage position on the particle size distribution (PSD) of a steroid suspension metered dose inhaler (MDI) containing propellant HFA-227. It was hypothesized that the orientation of MDI samples upon storage could influence the PSD of the emitted dose, since it determines the amount of contact the liquid formulation has with the valve and therefore the quantity of nonvolatile leachable materials from the valve components that may enter the product and potentially impact the aerosol spray dynamics. Samples stored in the valve down orientation (i.e., complete contact of the liquid formulation with the valve) showed a higher level of leachables compared to those samples stored valve up (i.e., minimal contact of the formulation with the valve). The valve down samples were found to produce larger particles in the emitted aerosol spray using both cascade impaction, the preferred method of regulatory submission, as well as laser diffraction. It was postulated that the larger particle size of the inverted samples was attributed to its higher levels of leachables. Based on our findings, it is recommended that in order to set appropriate controls on the product PSD, the storage orientation of the product will need to be considered.


Drug Development and Industrial Pharmacy | 2004

Influence of the valve lubricant on the aerodynamic particle size of a metered dose inhaler.

Julianne Berry; Lukeysha C. Kline; Venkatesh Naini; Saeed Chaudhry; John L. Hart; Joel A. Sequeira

Presented in this work are the results of a study designed to investigate the impact of valve lubricant (i.e., silicone oil) on the aerodynamic particle size distribution (PSD) of a steroid suspension metered dose inhaler (MDI) containing propellant HFA‐227. The objective of this study was to explore whether the valve lubricant, which is often used in MDI products to prevent valve sticking, can enter an MDI product and potentially impact the aerosol spray dynamics. The results of this work have shown that samples containing valves with high silicone levels produced a larger aerodynamic particle size (by cascade impaction) than samples with low‐silicone or silicone‐free valves. It is postulated that the presence of silicone in the product may increase the propensity for drug aggregation, thereby leading to an increase in the aerodynamic particle size of the emitted aerosol. These findings stress the importance of evaluating the effects of valve lubricant on the aerodynamic PSD in the early formulation development stage of an MDI.


Drug Development and Industrial Pharmacy | 2004

Influence of the Size of Micronized Active Pharmaceutical Ingredient on the Aerodynamic Particle Size and Stability of a Metered Dose Inhaler

Julianne Berry; Lukeysha C. Kline; Jill K. Sherwood; Saeed Chaudhry; Linda J. Obenauer-Kutner; John L. Hart; Joel A. Sequeira

Pharmaceutical inhalers are often used to treat pulmonary diseases. Only active pharmaceutical ingredient (API) particles from these inhalers that are less than approximately 5 µm are likely to reach the lung and be efficacious. This study was designed to investigate the impact of micronized API particle size on the aerodynamic particle size distribution (PSD) profile and the particle size stability of a suspension metered dose inhaler (MDI) containing propellant HFA‐227 (1,1,1,2,3,3,3 heptafluoropropane) and a corticosteroid. The median API particle size ranged from 1.1 µm to 1.8 µm (97% to 70% of particles < 3 µm, respectively). This study showed that increasing the particle size of the API used to manufacture a suspension MDI product increased the aerodynamic PSD of the MDI product. Furthermore, upon storage of the MDI product under temperature cycling conditions, samples containing larger‐size API particles were less stable with respect to their aerodynamic PSD than those with smaller‐size API particles. It was found that size‐dependent particle growth and/or aggregation of the suspended API may be occurring as a result of temperature cycling. In conclusion, this study has shown that the particle size of the raw API impacts the properties and stability of the emitted aerosol spray. Based on the findings from this study, it is recommended that the API particle size be carefully controlled in order to meet specifications set for the finished MDI product.


Drug Development and Industrial Pharmacy | 2004

Entry port selection for detecting particle size differences in metered dose inhaler formulations using cascade impaction

Venkatesh Naini; Saeed Chaudhry; Julianne Berry; Stefan A. Sharpe; John L. Hart; Joel A. Sequeira

Different sized glass entry ports were evaluated for their drug collection efficiency during aerodynamic particle sizing of metered dose inhalers (MDIs) using cascade impaction. A comparison was made between collection efficiency in the entry port, impactor plates, and filter using the 1 L, 2 L, and 20 L glass entry ports and the USP and twin impinger entry ports. Entry port losses were dependent on the size of entry port selected, with 1–2 L ports showing optimal recovery on impactor plates, compared to the USP entry port. The 1 L entry port was further compared with the USP entry port in its ability to discriminate between subtle changes in particle size distribution (PSD) in an investigational hydrofluoroalkane (HFA)‐based MDI formulation. Deliberately induced differences during product manufacture were easily detected using the 1 L entry port with the Andersen cascade impactor. The USP port was unable to distinguish among products with small particle size differences. An alternative entry port such as the 1 L glass entry port used in this study may provide better means of characterizing the PSD during formulation development and stability testing of MDIs.


Drug Development and Industrial Pharmacy | 2007

Particle size coarsening induced by valve silicone in a metered dose inhaler.

Jill K. Sherwood; Sony Alex; Germain Salama; Linda J. Obenauer-Kutner; Susan Huyck; Julianne Berry; Joel A. Sequeira; Guillaume Brouet; Christophe Marie

ABSTRACT The objective of this study was to evaluate the effect of valve silicone on the delivered particle size distribution of a suspension metered dose inhaler (MDI). Valves were manufactured with distinct levels of silicone, which could be differentiated with Fourier transform infrared spectroscopy (FT-IR). The amount of silicone in the valve was proportional to the amount of silicone that entered the formulation and the subsequent decrease in fine particle fraction (FPF) of the active pharmaceutical ingredient (API) measured by Andersen cascade impaction. The effect of silicone content was not linear as even small amounts of silicone made a significant contribution to particle size coarsening. This coarsening was also a function of storage time and temperature. Accelerated stability conditions greatly increased coarsening kinetics as 1 month at 40°C and 75% RH induced significantly more coarsening than 12 months at room temperature. Field emission scanning electron micrograph images suggest that the primary mechanism of particle size change may be aggregation as particle clusters were seen. This study indicates that silicone can be a critical process parameter for particle size distribution of a suspension MDI product. Thus, the amount of silicone in the valves needs to be minimized and controlled.


Archive | 1997

Chlorofluorocarbon-free mometasone furoate aerosol formulations

Julianne Berry; Joel A. Sequeira; Imtiaz A. Chaudry


Archive | 1992

Non-chloroflurocarbon aerosol formulations

Julianne Berry; Imtiaz A. Chaudry; Joel A. Sequeira; Michael Kopcha


Archive | 2004

Pharmazeutische aerosol-zusammensetzungen

Julianne Berry; Jill K. Sherwood; Saeed Chaudhry; Joel A. Sequeira


Archive | 2003

Verfahren zur herstellung von dosierinhalatorformulierungen

Saeed Chaudhry; Stefan A. Sharpe; Julianne Berry; Joel A. Sequeira

Collaboration


Dive into the Julianne Berry's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge