Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Juliette Selb is active.

Publication


Featured researches published by Juliette Selb.


Radiology | 2011

Combined Optical and X-ray Tomosynthesis Breast Imaging

Qianqian Fang; Juliette Selb; Stefan A. Carp; Gregory Boverman; Eric L. Miller; Dana H. Brooks; Richard H. Moore; Daniel B. Kopans; David A. Boas

PURPOSE To explore the optical and physiologic properties of normal and lesion-bearing breasts by using a combined optical and digital breast tomosynthesis (DBT) imaging system. MATERIALS AND METHODS Institutional review board approval and patient informed consent were obtained for this HIPAA-compliant study. Combined optical and tomosynthesis imaging analysis was performed in 189 breasts from 125 subjects (mean age, 56 years ± 13 [standard deviation]), including 138 breasts with negative findings and 51 breasts with lesions. Three-dimensional (3D) maps of total hemoglobin concentration (Hb(T)), oxygen saturation (So(2)), and tissue reduced scattering coefficients were interpreted by using the coregistered DBT images. Paired and unpaired t tests were performed between various tissue types to identify significant differences. RESULTS The estimated average bulk Hb(T) from 138 normal breasts was 19.2 μmol/L. The corresponding mean So(2) was 0.73, within the range of values in the literature. A linear correlation (R = 0.57, P < .0001) was found between Hb(T) and the fibroglandular volume fraction derived from the 3D DBT scans. Optical reconstructions of normal breasts revealed structures corresponding to chest-wall muscle, fibroglandular, and adipose tissues in the Hb(T), So(2), and scattering images. In 26 malignant tumors of 0.6-2.5 cm in size, Hb(T) was significantly greater than that in the fibroglandular tissue of the same breast (P = .0062). Solid benign lesions (n = 17) and cysts (n = 8) had significantly lower Hb(T) contrast than did the malignant lesions (P = .025 and P = .0033, respectively). CONCLUSION The optical and DBT images were structurally consistent. The malignant tumors and benign lesions demonstrated different Hb(T) and scattering contrasts, which can potentially be exploited to reduce the false-positive rate of conventional mammography and unnecessary biopsies.


Journal of Biomedical Optics | 2005

Improved sensitivity to cerebral hemodynamics during brain activation with a time-gated optical system: analytical model and experimental validation

Juliette Selb; Jonathan J. Stott; Maria Angela Franceschini; A. Gregory Sorensen; David A. Boas

Time domain (TD) diffuse optical measurement systems are being applied to neuroimaging, where they can detect hemodynamics changes associated with cerebral activity. We show that TD systems can provide better depth sensitivity than the more traditional continuous wave (CW) systems by gating late photons, which carry information about deep layers of the brain, and rejecting early light, which is sensitive to the superficial physiological signal clutter. We use an analytical model to estimate the contrast due to an activated region of the brain, the instrumental noise of the systems, and the background signal resulting from superficial physiological signal clutter. We study the contrast-to-noise ratio and the contrast-to-background ratio as a function of the activation depth and of the source-detector separation. We then present experimental results obtained with a time-gated instrument on the motor cortex during finger-tapping exercises. Both the model and the experimental results show a similar contrast-to-noise ratio for CW and TD, but that estimation of the contrast is experimentally limited by background fluctuations and that a better contrast-to-background ratio is obtained in the TD case. Finally, we use the time-gated measurements to resolve in depth the brain activation during the motor stimulus.


NeuroImage | 2014

Motion artifacts in functional near-infrared spectroscopy: A comparison of motion correction techniques applied to real cognitive data

Sabrina Brigadoi; Lisa Ceccherini; Simone Cutini; Fabio Scarpa; Pietro Scatturin; Juliette Selb; Louis Gagnon; David A. Boas; Robert J. Cooper

Motion artifacts are a significant source of noise in many functional near-infrared spectroscopy (fNIRS) experiments. Despite this, there is no well-established method for their removal. Instead, functional trials of fNIRS data containing a motion artifact are often rejected completely. However, in most experimental circumstances the number of trials is limited, and multiple motion artifacts are common, particularly in challenging populations. Many methods have been proposed recently to correct for motion artifacts, including principle component analysis, spline interpolation, Kalman filtering, wavelet filtering and correlation-based signal improvement. The performance of different techniques has been often compared in simulations, but only rarely has it been assessed on real functional data. Here, we compare the performance of these motion correction techniques on real functional data acquired during a cognitive task, which required the participant to speak aloud, leading to a low-frequency, low-amplitude motion artifact that is correlated with the hemodynamic response. To compare the efficacy of these methods, objective metrics related to the physiology of the hemodynamic response have been derived. Our results show that it is always better to correct for motion artifacts than reject trials, and that wavelet filtering is the most effective approach to correcting this type of artifact, reducing the area under the curve where the artifact is present in 93% of the cases. Our results therefore support previous studies that have shown wavelet filtering to be the most promising and powerful technique for the correction of motion artifacts in fNIRS data. The analyses performed here can serve as a guide for others to objectively test the impact of different motion correction algorithms and therefore select the most appropriate for the analysis of their own fNIRS experiment.


IEEE Transactions on Medical Imaging | 2009

Combined Optical Imaging and Mammography of the Healthy Breast: Optical Contrast Derived From Breast Structure and Compression

Qianqian Fang; Stefan A. Carp; Juliette Selb; Gregory Boverman; Quan Zhang; Daniel B. Kopans; Richard H. Moore; Eric L. Miller; Dana H. Brooks; David A. Boas

In this paper, we report new progress in developing the instrument and software platform of a combined X-ray mammography/diffuse optical breast imaging system. Particularly, we focus on system validation using a series of balloon phantom experiments and the optical image analysis of 49 healthy patients. Using the finite-element method for forward modeling and a regularized Gauss-Newton method for parameter reconstruction, we recovered the inclusions inside the phantom and the hemoglobin images of the human breasts. An enhanced coupling coefficient estimation scheme was also incorporated to improve the accuracy and robustness of the reconstructions. The recovered average total hemoglobin concentration (HbT) and oxygen saturation (SO<sub>2</sub>) from 68 breast measurements are 16.2 mum and 71%, respectively, where the HbT presents a linear trend with breast density. The low HbT value compared to literature is likely due to the associated mammographic compression. From the spatially co-registered optical/X-ray images, we can identify the chest-wall muscle, fatty tissue, and fibroglandular regions with an average HbT of 20.1plusmn6.1 &nbsp;mum for fibroglandular tissue, 15.4plusmn5.0&nbsp;mum for adipose, and 22.2plusmn7.3&nbsp;mum for muscle tissue. The differences between fibroglandular tissue and the orresponding adipose tissue are significant. At the same time, we recognize that the optical images are influenced, to a certain extent, by mammographical compression. The optical images from a subset of patients show composite features from both tissue structure and pressure distribution. We present mechanical simulations which further confirm this hypothesis.


Frontiers in Neuroscience | 2012

A Systematic Comparison of Motion Artifact Correction Techniques for Functional Near-Infrared Spectroscopy

Robert J. Cooper; Juliette Selb; Louis Gagnon; Dorte Phillip; Henrik Winther Schytz; Helle K. Iversen; Messoud Ashina; David A. Boas

Near-infrared spectroscopy (NIRS) is susceptible to signal artifacts caused by relative motion between NIRS optical fibers and the scalp. These artifacts can be very damaging to the utility of functional NIRS, particularly in challenging subject groups where motion can be unavoidable. A number of approaches to the removal of motion artifacts from NIRS data have been suggested. In this paper we systematically compare the utility of a variety of published NIRS motion correction techniques using a simulated functional activation signal added to 20 real NIRS datasets which contain motion artifacts. Principle component analysis, spline interpolation, wavelet analysis, and Kalman filtering approaches are compared to one another and to standard approaches using the accuracy of the recovered, simulated hemodynamic response function (HRF). Each of the four motion correction techniques we tested yields a significant reduction in the mean-squared error (MSE) and significant increase in the contrast-to-noise ratio (CNR) of the recovered HRF when compared to no correction and compared to a process of rejecting motion-contaminated trials. Spline interpolation produces the largest average reduction in MSE (55%) while wavelet analysis produces the highest average increase in CNR (39%). On the basis of this analysis, we recommend the routine application of motion correction techniques (particularly spline interpolation or wavelet analysis) to minimize the impact of motion artifacts on functional NIRS data.


NeuroImage | 2012

Quantification of the cortical contribution to the NIRS signal over the motor cortex using concurrent NIRS-fMRI measurements.

Louis Gagnon; Meryem A. Yücel; Mathieu Dehaes; Robert J. Cooper; Katherine L. Perdue; Juliette Selb; Theodore J. Huppert; Richard D. Hoge; David A. Boas

Near-Infrared Spectroscopy (NIRS) measures the functional hemodynamic response occurring at the surface of the cortex. Large pial veins are located above the surface of the cerebral cortex. Following activation, these veins exhibit oxygenation changes but their volume likely stays constant. The back-reflection geometry of the NIRS measurement renders the signal very sensitive to these superficial pial veins. As such, the measured NIRS signal contains contributions from both the cortical region as well as the pial vasculature. In this work, the cortical contribution to the NIRS signal was investigated using (1) Monte Carlo simulations over a realistic geometry constructed from anatomical and vascular MRI and (2) multimodal NIRS-BOLD recordings during motor stimulation. A good agreement was found between the simulations and the modeling analysis of in vivo measurements. Our results suggest that the cortical contribution to the deoxyhemoglobin signal change (ΔHbR) is equal to 16-22% of the cortical contribution to the total hemoglobin signal change (ΔHbT). Similarly, the cortical contribution of the oxyhemoglobin signal change (ΔHbO) is equal to 73-79% of the cortical contribution to the ΔHbT signal. These results suggest that ΔHbT is far less sensitive to pial vein contamination and therefore, it is likely that the ΔHbT signal provides better spatial specificity and should be used instead of ΔHbO or ΔHbR to map cerebral activity with NIRS. While different stimuli will result in different pial vein contributions, our finger tapping results do reveal the importance of considering the pial contribution.


Journal of Biomedical Optics | 2006

Time-gated optical system for depth-resolved functional brain imaging.

Juliette Selb; Danny K. Joseph; David A. Boas

We present a time-domain optical system for functional imaging of the adult head. We first describe the instrument, which is based on a Ti:Sapphire pulsed laser (wavelength 750-850 nm) and an intensified CCD camera enabling parallel detection of multiple fibers. We characterize the system in terms of sensitivity and signal-to-noise ratio, instrument response function, cross-talk, stability, and reproducibility. We then describe two applications of the instrument: the characterization of baseline optical properties of homogeneous scattering media, and functional brain imaging. For the second application, we developed a two-part probe consisting in two squares of 4 x 4 sources and 3 x 3 detectors. The laser source is time-multiplexed to define 4 states of 8 sources that can be turned on during the same camera frame while minimizing cross-talk. On the detection side, we use for each detector 7 fibers of different lengths creating an optical delay, and enabling simultaneous detection in 7 windows (by steps of 500 ps) for each detector. This multiple window detection allows depth sensitivity. The imaging probe was tested on dynamic phantoms and a preliminary result on an adult performing a motor task shows discrimination between superficial and cortical responses to the stimulus on both hemispheres.


Journal of Cerebral Blood Flow and Metabolism | 2009

Increased cerebral blood volume and oxygen consumption in neonatal brain injury

P. Ellen Grant; Nadege Roche-Labarbe; Andrea Surova; George Themelis; Juliette Selb; Elizabeth K Warren; Kalpathy S. Krishnamoorthy; David A. Boas; Maria Angela Franceschini

With the increasing interest in treatments for neonatal brain injury, bedside methods for detecting and assessing injury status and evolution are needed. We aimed to determine whether cerebral tissue oxygenation (StO2), cerebral blood volume (CBV), and estimates of relative cerebral oxygen consumption (rCMRO2) determined by bedside frequency-domain near-infrared spectroscopy (FD-NIRS) have the potential to distinguish neonates with brain injury from those with non-brain issues and healthy controls. We recruited 43 neonates ≤15 days old and >33 weeks gestational age (GA): 14 with imaging evidence of brain injury, 29 without suspicion of brain injury (4 unstable, 6 stable, and 19 healthy). A multivariate analysis of variance with Newman–Keuls post hoc comparisons confirmed group similarity for GA and age at measurement. StO2 was significantly higher in brain injured compared with unstable neonates, but not statistically different from stable or healthy neonates. Brain-injured neonates were distinguished from all others by significant increases in CBV and rCMRO2. In conclusion, although NIRS measures of StO2 alone may be insensitive to evolving brain injury, increased CBV and rCMRO2 seem to be useful for detecting neonatal brain injury and suggest increased neuronal activity and metabolism occurs acutely in evolving brain injury.


Physics in Medicine and Biology | 2007

Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography

Gregory Boverman; Qianqian Fang; Stefan A. Carp; Eric L. Miller; Dana H. Brooks; Juliette Selb; Richard H. Moore; Daniel B. Kopans; David A. Boas

We develop algorithms for imaging the time-varying optical absorption within the breast given diffuse optical tomographic data collected over a time span that is long compared to the dynamics of the medium. Multispectral measurements allow for the determination of the time-varying total hemoglobin concentration and of oxygen saturation. To facilitate the image reconstruction, we decompose the hemodynamics in time into a linear combination of spatio-temporal basis functions, the coefficients of which are estimated using all of the data simultaneously, making use of a Newton-based nonlinear optimization algorithm. The solution of the extremely large least-squares problem which arises in computing the Newton update is obtained iteratively using the LSQR algorithm. A Laplacian spatial regularization operator is applied, and, in addition, we make use of temporal regularization which tends to encourage similarity between the images of the spatio-temporal coefficients. Results are shown for an extensive simulation, in which we are able to image and quantify localized changes in both total hemoglobin concentration and oxygen saturation. Finally, a breast compression study has been performed for a normal breast cancer screening subject, using an instrument which allows for highly accurate co-registration of multispectral diffuse optical measurements with an x-ray tomosynthesis image of the breast. We are able to quantify the global return of blood to the breast following compression, and, in addition, localized changes are observed which correspond to the glandular region of the breast.


Optics Express | 2008

Dynamic functional and mechanical response of breast tissue to compression

Stefan A. Carp; Juliette Selb; Qianqian Fang; Richard H. Moore; Daniel B. Kopans; Elizabeth A. Rafferty; David A. Boas

Physiological tissue dynamics following breast compression offer new contrast mechanisms for evaluating breast health and disease with near infrared spectroscopy. We monitored the total hemoglobin concentration and hemoglobin oxygen saturation in 28 healthy female volunteers subject to repeated fractional mammographic compression. The compression induces a reduction in blood flow, in turn causing a reduction in hemoglobin oxygen saturation. At the same time, a two phase tissue viscoelastic relaxation results in a reduction and redistribution of pressure within the tissue and correspondingly modulates the tissue total hemoglobin concentration and oxygen saturation. We observed a strong correlation between the relaxing pressure and changes in the total hemoglobin concentration bearing evidence of the involvement of different vascular compartments. Consequently, we have developed a model that enables us to disentangle these effects and obtain robust estimates of the tissue oxygen consumption and blood flow. We obtain estimates of 1.9+/-1.3 micromol/100 mL/min for OC and 2.8+/-1.7 mL/100 mL/min for blood flow, consistent with other published values.

Collaboration


Dive into the Juliette Selb's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Messoud Ashina

University of Copenhagen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dorte Phillip

University of Copenhagen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge