Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Junzhong Xu is active.

Publication


Featured researches published by Junzhong Xu.


NMR in Biomedicine | 2014

Inverse Z-spectrum analysis for spillover-, MT-, and T1-corrected steady-state pulsed CEST-MRI – application to pH-weighted MRI of acute stroke

Moritz Zaiss; Junzhong Xu; Steffen Goerke; Imad Saeed Khan; Robert J. Singer; John C. Gore; Daniel F. Gochberg; Peter Bachert

Endogenous chemical exchange saturation transfer (CEST) effects are always diluted by competing effects, such as direct water proton saturation (spillover) and semi‐solid macromolecular magnetization transfer (MT). This leads to unwanted T2 and MT signal contributions that lessen the CEST signal specificity to the underlying biochemical exchange processes. A spillover correction is of special interest for clinical static field strengths and protons resonating near the water peak. This is the case for all endogenous CEST agents, such as amide proton transfer, –OH‐CEST of glycosaminoglycans, glucose or myo‐inositol, and amine exchange of creatine or glutamate. All CEST effects also appear to be scaled by the T1 relaxation time of water, as they are mediated by the water pool. This forms the motivation for simple metrics that correct the CEST signal.


NMR in Biomedicine | 2010

Characterization of tissue structure at varying length scales using temporal diffusion spectroscopy

John C. Gore; Junzhong Xu; Daniel C. Colvin; Thomas E. Yankeelov; Edward C. Parsons; Mark D. Does

The concepts, theoretical behavior and experimental applications of temporal diffusion spectroscopy are reviewed and illustrated. Temporal diffusion spectra are obtained using oscillating‐gradient waveforms in diffusion‐weighted measurements, and represent the manner in which various spectral components of molecular velocity correlations vary in different geometrical structures that restrict or hinder free movements. Measurements made at different gradient frequencies reveal information on the scale of restrictions or hindrances to free diffusion, and the shape of a spectrum reveals the relative contributions of spatial restrictions at different distance scales. Such spectra differ from other so‐called diffusion spectra which depict spatial frequencies and are defined at a fixed diffusion time. Experimentally, oscillating gradients at moderate frequency are more feasible for exploring restrictions at very short distances which, in tissues, correspond to structures smaller than cells. We describe the underlying concepts of temporal diffusion spectra and provide analytical expressions for the behavior of the diffusion coefficient as a function of gradient frequency in simple geometries with different dimensions. Diffusion in more complex model media that mimic tissues has been simulated using numerical methods. Experimental measurements of diffusion spectra have been obtained in suspensions of particles and cells, as well as in vivo in intact animals. An observation of particular interest is the increased contrast and heterogeneity observed in tumors using oscillating gradients at moderate frequency compared with conventional pulse gradient methods, and the potential for detecting changes in tumors early in their response to treatment. Computer simulations suggest that diffusion spectral measurements may be sensitive to intracellular structures, such as nuclear size, and that changes in tissue diffusion properties may be measured before there are changes in cell density. Copyright


NMR in Biomedicine | 2014

On the origins of chemical exchange saturation transfer (CEST) contrast in tumors at 9.4 T

Junzhong Xu; Moritz Zaiss; Zhongliang Zu; Hua Li; Jingping Xie; Daniel F. Gochberg; Peter Bachert; John C. Gore

Chemical exchange saturation transfer (CEST) provides an indirect means to detect exchangeable protons within tissues through their effects on the water signal. Previous studies have suggested that amide proton transfer (APT) imaging, a specific form of CEST, detects endogenous amide protons with a resonance frequency offset 3.5 ppm downfield from water, and thus may be sensitive to variations in mobile proteins/peptides in tumors. However, as CEST measurements are influenced by various confounding effects, such as spillover saturation, magnetization transfer (MT) and MT asymmetry, the mechanism or degree of increased APT signal in tumors is not certain. In addition to APT, nuclear Overhauser enhancement (NOE) effects upfield from water may also provide distinct information on tissue composition. In the current study, APT, NOE and several other MR parameters were measured and compared comprehensively in order to elucidate the origins of APT and NOE contrasts in tumors at 9.4 T. In addition to conventional CEST methods, a new intrinsic inverse metric was applied to correct for relaxation and other effects. After corrections for spillover, MT and T1 effects, corrected APT in tumors was found not to be significantly different from that in normal tissues, but corrected NOE effects in tumors showed significant decreases compared with those in normal tissues. Biochemical measurements verified that there was no significant enhancement of protein contents in the tumors studied, consistent with the corrected APT measurements and previous literature, whereas quantitative MT data showed decreases in the fractions of immobile macromolecules in tumors. Our results may assist in the better understanding of the contrast depicted by CEST imaging in tumors, and in the development of improved APT and NOE measurements for cancer imaging. Copyright


Magnetic Resonance in Medicine | 2013

A new method for detecting exchanging amide protons using chemical exchange rotation transfer

Zhongliang Zu; Vaibhav Janve; Junzhong Xu; Mark D. Does; John C. Gore; Daniel F. Gochberg

In this study, we introduce a new method for amide proton transfer imaging based on chemical exchange rotation transfer. It avoids several artifacts that plague conventional chemical exchange saturation transfer approaches by creating label and reference scans based on varying the irradiation pulse rotation angle (π and 2π radians) instead of the frequency offset (3.5 and −3.5 ppm). Specifically, conventional analysis is sensitive to confounding contributions from magnetic field (B0) inhomogeneities and, more problematically, inherently asymmetric macromolecular resonances. In addition, the lipid resonance at −3.5 ppm complicates the interpretation of the reference scan and decreases the resulting contrast. Finally, partial overlap of the amide signal by nearby amines and hydroxyls obscure the results. By avoiding these issues, our new method is a promising approach for imaging endogenous protein and peptide content and mapping pH. Magn Reson Med, 2013.


Magnetic Resonance in Medicine | 2009

Sensitivity of MR Diffusion Measurements to Variations in Intracellular Structure: Effects of Nuclear Size

Junzhong Xu; Mark D. Does; John C. Gore

Magnetic resonance imaging measurements of the apparent rate of water diffusion in tumors are sensitive to variations in tissue cellularity, which have been shown useful for characterizing tumors and their responses to treatments. However, because of technical limitations on most MRI systems, conventional pulse gradient spin echo (PGSE) methods measure relatively long time scales, during which water molecules may encounter diffusion barriers at multiple spatial scales, including those much greater than typical cell dimensions. As such they cannot distinguish changes on subcellular scales from gross changes in cell density. Oscillating gradient spin echo (OGSE) methods have the potential to distinguish effects on restriction at much shorter time and length scales. Both PGSE and OGSE methods have been studied numerically by simulating diffusion in a three‐dimensional, multicompartment tissue model. The results show that conventional measurements with the PGSE method cannot selectively probe variations over short length scales and, therefore, are relatively insensitive to intracellular structure, whereas results using OGSE methods at moderate gradient frequencies are affected by variations in cell nuclear sizes and can distinguish tissues that differ only over subcellular length scales. This additional sensitivity suggests that OGSE imaging may have significant advantages over conventional PGSE methods for characterizing tumors. Magn Reson Med, 2009.


NeuroImage | 2014

Mapping mean axon diameter and axonal volume fraction by MRI using temporal diffusion spectroscopy

Junzhong Xu; Hua Li; Kevin D. Harkins; Xiaoyu Jiang; Jingping Xie; Hakmook Kang; Mark D. Does; John C. Gore

Mapping mean axon diameter and intra-axonal volume fraction may have significant clinical potential because nerve conduction velocity is directly dependent on axon diameter, and several neurodegenerative diseases affect axons of specific sizes and alter axon counts. Diffusion-weighted MRI methods based on the pulsed gradient spin echo (PGSE) sequence have been reported to be able to assess axon diameter and volume fraction non-invasively. However, due to the relatively long diffusion times used, e.g. >20ms, the sensitivity to small axons (diameter<2μm) is low, and the derived mean axon diameter has been reported to be overestimated. In the current study, oscillating gradient spin echo (OGSE) diffusion sequences with variable frequency gradients were used to assess rat spinal white matter tracts with relatively short effective diffusion times (1-5ms). In contrast to previous PGSE-based methods, the extra-axonal diffusion cannot be modeled as hindered (Gaussian) diffusion when short diffusion times are used. Appropriate frequency-dependent rates are therefore incorporated into our analysis and validated by histology-based computer simulation of water diffusion. OGSE data were analyzed to derive mean axon diameters and intra-axonal volume fractions of rat spinal white matter tracts (mean axon diameter of ~1.27-5.54μm). The estimated values were in good agreement with histology, including the small axon diameters (<2.5μm). This study establishes a framework for the quantification of nerve morphology using the OGSE method with high sensitivity to small axons.


NMR in Biomedicine | 2015

A combined analytical solution for chemical exchange saturation transfer and semi-solid magnetization transfer

Moritz Zaiss; Zhongliang Zu; Junzhong Xu; Patrick Schuenke; Daniel F. Gochberg; John C. Gore; Mark E. Ladd; Peter Bachert

Off‐resonant RF irradiation in tissue indirectly lowers the water signal by saturation transfer processes: on the one hand, there are selective chemical exchange saturation transfer (CEST) effects originating from exchanging endogenous protons resonating a few parts per million from water; on the other hand, there is the broad semi‐solid magnetization transfer (MT) originating from immobile protons associated with the tissue matrix with kilohertz linewidths. Recently it was shown that endogenous CEST contrasts can be strongly affected by the MT background, so corrections are needed to derive accurate estimates of CEST effects. Herein we show that a full analytical solution of the underlying Bloch–McConnell equations for both MT and CEST provides insights into their interaction and suggests a simple means to isolate their effects. The presented analytical solution, based on the eigenspace solution of the Bloch–McConnell equations, extends previous treatments by allowing arbitrary lineshapes for the semi‐solid MT effects and simultaneously describing multiple CEST pools in the presence of a large MT pool for arbitrary irradiation. The structure of the model indicates that semi‐solid MT and CEST effects basically add up inversely in determining the steady‐state Z‐spectrum, as previously shown for direct saturation and CEST effects. Implications for existing previous CEST analyses in the presence of a semi‐solid MT are studied and discussed. It turns out that, to accurately quantify CEST contrast, a good reference Z‐value, the observed longitudinal relaxation rate of water, and the semi‐solid MT pool size fraction must all be known. Copyright


Journal of Magnetic Resonance | 2009

Quantitative characterization of tissue microstructure with temporal diffusion spectroscopy.

Junzhong Xu; Mark D. Does; John C. Gore

The signals recorded by diffusion-weighted magnetic resonance imaging (DWI) are dependent on the micro-structural properties of biological tissues, so it is possible to obtain quantitative structural information non-invasively from such measurements. Oscillating gradient spin echo (OGSE) methods have the ability to probe the behavior of water diffusion over different time scales and the potential to detect variations in intracellular structure. To assist in the interpretation of OGSE data, analytical expressions have been derived for diffusion-weighted signals with OGSE methods for restricted diffusion in some typical structures, including parallel planes, cylinders and spheres, using the theory of temporal diffusion spectroscopy. These analytical predictions have been confirmed with computer simulations. These expressions suggest how OGSE signals from biological tissues should be analyzed to characterize tissue microstructure, including how to estimate cell nuclear sizes. This approach provides a model to interpret diffusion data obtained from OGSE measurements that can be used for applications such as monitoring tumor response to treatment in vivo.


Physics in Medicine and Biology | 2007

Numerical study of water diffusion in biological tissues using an improved finite difference method

Junzhong Xu; Mark D. Does; John C. Gore

An improved finite difference (FD) method has been developed in order to calculate the behaviour of the nuclear magnetic resonance signal variations caused by water diffusion in biological tissues more accurately and efficiently. The algorithm converts the conventional image-based finite difference method into a convenient matrix-based approach and includes a revised periodic boundary condition which eliminates the edge effects caused by artificial boundaries in conventional FD methods. Simulated results for some modelled tissues are consistent with analytical solutions for commonly used diffusion-weighted pulse sequences, whereas the improved FD method shows improved efficiency and accuracy. A tightly coupled parallel computing approach was also developed to implement the FD methods to enable large-scale simulations of realistic biological tissues. The potential applications of the improved FD method for understanding diffusion in tissues are also discussed.


Magnetic Resonance in Medicine | 2014

Imaging amide proton transfer and nuclear overhauser enhancement using chemical exchange rotation transfer (CERT).

Zhongliang Zu; Junzhong Xu; Hua Li; Eduard Y. Chekmenev; C. Chad Quarles; Mark D. Does; John C. Gore; Daniel F. Gochberg

This study investigates amide proton transfer (APT) and nuclear overhauser enhancement (NOE) in phantoms and 9L tumors in rat brains at 9.4 Tesla, using a recently developed method that can isolate different contributions to exchange.

Collaboration


Dive into the Junzhong Xu's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hua Li

Vanderbilt University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ke Li

Vanderbilt University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Feng Wang

Vanderbilt University

View shared research outputs
Researchain Logo
Decentralizing Knowledge