Justin S. Valenstein
Ecolab
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Justin S. Valenstein.
Plant Physiology | 2014
Susana Martin-Ortigosa; David J. Peterson; Justin S. Valenstein; Victor S.-Y. Lin; Brian G. Trewyn; L. Alexander Lyznik; Kan Wang
A recombinase protein loaded into mesoporous silica nanoparticles was delivered through the biolistic method to maize tissues, leading to site-specific recombination. The delivery of proteins instead of DNA into plant cells allows for a transient presence of the protein or enzyme that can be useful for biochemical analysis or genome modifications. This may be of particular interest for genome editing, because it can avoid DNA (transgene) integration into the genome and generate precisely modified “nontransgenic” plants. In this work, we explore direct protein delivery to plant cells using mesoporous silica nanoparticles (MSNs) as carriers to deliver Cre recombinase protein into maize (Zea mays) cells. Cre protein was loaded inside the pores of gold-plated MSNs, and these particles were delivered by the biolistic method to plant cells harboring loxP sites flanking a selection gene and a reporter gene. Cre protein was released inside the cell, leading to recombination of the loxP sites and elimination of both genes. Visual selection was used to select recombination events from which fertile plants were regenerated. Up to 20% of bombarded embryos produced calli with the recombined loxP sites under our experimental conditions. This direct and reproducible technology offers an alternative for DNA-free genome-editing technologies in which MSNs can be tailored to accommodate the desired enzyme and to reach the desired tissue through the biolistic method.
Small | 2012
Susana Martin-Ortigosa; Justin S. Valenstein; Wei Sun; Lorena Moeller; Ning Fang; Brian G. Trewyn; Victor S.-Y. Lin; Kan Wang
Applying nanotechnology to plant science requires efficient systems for the delivery of nanoparticles (NPs) to plant cells and tissues. The presence of a cell wall in plant cells makes it challenging to extend the NP delivery methods available for animal research. In this work, research is presented which establishes an efficient NP delivery system for plant tissues using the biolistic method. It is shown that the biolistic delivery of mesoporous silica nanoparticle (MSN) materials can be improved by increasing the density of MSNs through gold plating. Additionally, a DNA-coating protocol is used based on calcium chloride and spermidine for MSN and gold nanorods to enhance the NP-mediated DNA delivery. Furthermore, the drastic improvement of NP delivery is demonstrated when the particles are combined with 0.6 μm gold particles during bombardment. The methodology described provides a system for the efficient delivery of NPs into plant cells using the biolistic method.
ACS Applied Materials & Interfaces | 2012
Justin S. Valenstein; Kapil Kandel; Forrest Melcher; Igor I. Slowing; Victor S.-Y. Lin; Brian G. Trewyn
A series of 2d-hexagonally packed mesoporous silica nanoparticle material with 10 nm pore diameter (MSN-10) covalently functionalized with organic surface modifiers have been synthesized via a post-synthesis grafting method. The material structure has been characterized by powder X-ray diffraction, electron microscopy, and nitrogen sorption analyses, and the free fatty acid (FFA) sequestration capacity and selectivity was investigated and quantified by thermogravimetric and GC/MS analysis. We discovered that aminopropyl functionalized 10 nm pore mesoporous silica nanoparticle material (AP-MSN-10) sequestered all available FFAs and left nearly all other molecules in solution from a simulated microalgal extract containing FFAs, sterols, terpenes, and triacylglycerides. We also demonstrated selective FFA sequestration from commercially available microalgal oil.
ACS Applied Materials & Interfaces | 2014
Robert A. Roggers; Madhura Joglekar; Justin S. Valenstein; Brian G. Trewyn
Mesoporous silica nanoparticles (MSNs) have been repeatedly demonstrated as potential drug-delivery devices. The study of biocompatibility and interaction of these materials with the various cell types is of great interest with regard to the development of viable pharmaceutical products. By mimicking the cholesterol, phosphatidylcholine, and phosphatidylethanolamine composition of the outer leaflet of a human red blood cell (RBC), lipid-bilayer-coated mesoporous silica particles show considerably improved hemocompatibility over phosphatidylcholine-coated and uncoated large-pore MSN (l-MSN). These inorganic/organic composite nanomaterials are shown to be capable of interfacing with RBCs without damaging the cells even at relatively high concentrations, as observed through electron microscopy, UV-vis spectroscopy, and flow cytometry analyses. Interestingly, the absence of cholesterol in the outer bilayer composition is shown to produce toxic effects without resulting in hemolysis. By maintaining the ζ potential of lipid-bilayer-functionalized MSNs similar to that of the hemolytic l-MSNs, we demonstrate that the bilayer composition, and not the surface charge, plays a significant role in determining the hemocompatibility of MSN-based materials.
PLOS ONE | 2017
Elaine Black; Krista L. Owens; Richard Staub; Junzhong Li; Kristen A. Mills; Justin S. Valenstein; John D. Hilgren
Disinfectants play an important role in controlling microbial contamination on hard surfaces in hospitals. The effectiveness of disinfectants in real life can be predicted by laboratory tests that measure killing of microbes on carriers. The modified Quantitative Disk Carrier Test (QCT-2) is a standard laboratory method that employs American Iron and Steel Institute (AISI) Type 430 stainless steel carriers to measure hospital disinfectant efficacy against Clostridium difficile spores. The formation of a rust-colored precipitate was observed on Type 430 carriers when testing a peracetic acid (PAA)-based disinfectant with the QCT-2 method. It was hypothesized that the precipitate was indicative of corrosion of the Type 430 carrier, and that corrosion could impact efficacy results. The objective of this study was to compare the suitability of AISI Type 430 to Type 304 stainless steel carriers for evaluating PAA-based disinfectants using the QCT-2 method. Type 304 is more corrosion-resistant than Type 430, is ubiquitous in healthcare environments, and is used in other standard methods. Suitability of the carriers was evaluated by comparing their impacts on efficacy results and PAA degradation rates. In efficacy tests with 1376 ppm PAA, reductions of C. difficile spores after 5, 7 and 10 minutes on Type 430 carriers were at least about 1.5 log10 lower than reductions on Type 304 carriers. In conditions simulating a QCT-2 test, PAA concentration with Type 430 carriers was reduced by approximately 80% in 10 minutes, whereas PAA concentration in the presence of Type 304 carriers remained stable. Elemental analyses of residues on each carrier type after efficacy testing were indicative of corrosion on the Type 430 carrier. Use of Type 430 stainless steel carriers for measuring the efficacy of PAA-based disinfectants should be avoided as it can lead to an underestimation of real life sporicidal efficacy. Type 304 stainless steel carriers are recommended as a suitable alternative.
Advanced Functional Materials | 2012
Susana Martin-Ortigosa; Justin S. Valenstein; Victor S.-Y. Lin; Brian G. Trewyn; Kan Wang
Chemistry of Materials | 2014
Madhura Joglekar; Svitlana Pylypenko; Megan M. Otting; Justin S. Valenstein; Brian G. Trewyn
Advanced Functional Materials | 2012
Susana Martin-Ortigosa; Justin S. Valenstein; Victor S.-Y. Lin; Brian G. Trewyn; Kan Wang
Archive | 2017
John W. Bolduc; Eugene Tokhtuev; Anatoly Skirda; Anna Pilipchenko; Justin S. Valenstein; Amanda Bakken; Stacy Fawbush; Jeffrey S. Hutchison
Archive | 2017
John W. Bolduc; Eugene Tokhtuev; Anatoly Skirda; Anna Pilipchenko; Justin S. Valenstein; Amanda Bakken; Stacy Fawbush; Jeffrey S. Hutchison