Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kaori Ukegawa is active.

Publication


Featured researches published by Kaori Ukegawa.


PLOS ONE | 2016

Comparison of Macular Integrity Assessment (MAIA ™), MP-3, and the Humphrey Field Analyzer in the Evaluation of the Relationship between the Structure and Function of the Macula.

Kazuyuki Hirooka; Kana Misaki; Eri Nitta; Kaori Ukegawa; Shino Sato; Akitaka Tsujikawa

Purpose This study was conducted in order to compare relationships between the macular visual field (VF) mean sensitivity measured by MAIATM (Macular Integrity Assessment), MP-3, or Humphry field analyzer (HFA) and the ganglion cell and inner plexiform layer (GCA) thicknesses. Methods This cross-sectional study examined 73 glaucoma patients and 19 normal subjects. All subjects underwent measurements for GCA thickness by Cirrus HD-OCT and static threshold perimetry using MAIATM, MP-3, or HFA. VF and OCT in the retinal view were used to examine both the global relationship between the VF sensitivity and GCA thickness, and the superior hemiretina and inferior hemiretina. The relationship between the GCA thickness and macular sensitivity was examined by Spearman correlation analysis. Results For each instrument, statistically significant macular VF sensitivity (dB) and GCA thickness relationships were observed using the decibel scale (R = 0.547–0.687, all P < 0.001). The highest correlation for the global (R = 0.682) and the superior hemiretina (R = 0.594) GCA thickness-VF mean sensitivity was observed by the HFA. The highest correlation for the inferior hemiretina (R = 0.687) GCA thickness-VF mean sensitivity was observed by the MP-3. Among the three VF measurement instruments, however, no significant differences were found for the structure-function relationships. Conclusions All three VF measurement instruments found similar structure-function relationships in the central VF.


Medicine | 2016

Estimating the rate of retinal ganglion cell loss to detect glaucoma progression: An observational cohort study.

Kazuyuki Hirooka; Saeko Izumibata; Kaori Ukegawa; Eri Nitta; Akitaka Tsujikawa

AbstractThis study aimed to evaluate the relationship between glaucoma progression and estimates of the retinal ganglion cells (RGCs) obtained by combining structural and functional measurements in patients with glaucoma.In the present observational cohort study, we examined 116 eyes of 62 glaucoma patients. Using Cirrus optical coherence tomography (OCT), a minimum of 5 serial retinal nerve fiber layer (RNFL) measurements were performed in all eyes. There was a 3-year separation between the first and last measurements. Visual field (VF) testing was performed on the same day as the RNFL imaging using the Swedish Interactive Threshold Algorithm Standard 30–2 program of the Humphrey Field Analyzer. Estimates of the RGC counts were obtained from standard automated perimetry (SAP) and OCT, with a weighted average then used to determine a final estimate of the number of RGCs for each eye. Linear regression was used to calculate the rate of the RGC loss, and trend analysis was used to evaluate both serial RNFL thicknesses and VF progression.Use of the average RNFL thickness parameter of OCT led to detection of progression in 14 of 116 eyes examined, whereas the mean deviation slope detected progression in 31 eyes. When the rates of RGC loss were used, progression was detected in 41 of the 116 eyes, with a mean rate of RGC loss of −28,260 ± 8110 cells/year.Estimation of the rate of RGC loss by combining structural and functional measurements resulted in better detection of glaucoma progression compared to either OCT or SAP.


Acta Ophthalmologica | 2017

Retinal oxygen saturation before and after glaucoma surgery

Eri Nitta; Kazuyuki Hirooka; Takeru Shimazaki; Shino Sato; Kaori Ukegawa; Yuki Nakano; Akitaka Tsujikawa

This study compared retinal vessel oxygen saturation before and after glaucoma surgery.


PLOS ONE | 2018

Changes in choroidal area after intraocular pressure reduction following trabeculectomy

Hirokazu Kojima; Kazuyuki Hirooka; Eri Nitta; Kaori Ukegawa; Shozo Sonoda; Taiji Sakamoto

Purpose To investigate changes of the macular and peripapillary choroidal areas after trabeculectomy. Methods This prospective and interventional study examined 74 eyes of 74 patients with glaucoma uncontrolled by medical therapy. Enhanced depth imaging optical coherence tomography (EDI-OCT) recorded macular and peripapillary choroidal images at 1 day before trabeculectomy and at 2 weeks after surgery. The Niblack method was used to covert luminal and interstitial areas to binary images. Results At baseline, the mean intraocular pressure (IOP) was 17.6±6.3 mmHg, while it was 6.5±2.9 mmHg after trabeculectomy (P < 0.001). Increases were observed for the macular choroidal area after the surgery, with the total area increasing from 317,853±95,728 μm2 to 368,597±104,393 μm2, while the luminal area increased from 210,355±73,650 μm2 to 249,464±77,195 μm2, and the interstitial area increased from 107,498±27,613 μm2 to 119,133±31,811 μm2 (all P < 0.001). Increases were also observed after the surgery for the peripapillary choroidal area, with the total area increasing from 1,629,440±460,429 μm2 to 1,974,289±500,496 μm2, while the luminal area increased from 920,141±328,690 μm2 to 1,179,843±357,601 μm2, and the interstitial area increased from 709,299±153,179 μm2 to 794,446±169,029 μm2 (all P < 0.001). There was a significant increase in the ratio of the luminal to choroidal area in the macular area (67.2%) and in the peripapillary area (59.1%). Factors associated with the changes in the peripapillary choroidal area included decreases in the diastolic blood pressure and IOP. Conclusions A reduction in the IOP after trabeculectomy led to increases in the macular and peripapillary choroidal areas. Observed changes in the choroidal area after trabeculectomy are primarily due to increases in the luminal areas.


Journal of Ophthalmology | 2018

Influence of Disc Size on the Diagnostic Accuracy of Cirrus Spectral-Domain Optical Coherence Tomography in Glaucoma

Shino Sato; Kaori Ukegawa; Eri Nitta; Kazuyuki Hirooka

Purpose To examine the influence of optic disc size on the diagnostic accuracy of optic nerve head (ONH) parameters determined by Cirrus spectral-domain optical coherence tomography (Cirrus HD-OCT). Methods A total of 51 eyes of 51 normal participants and 71 eyes of 71 glaucoma patients were examined. ONH imaging was obtained by Cirrus HD-OCT. Sensitivity at a fixed 90% specificity along with the area under the receiver operating characteristic curve (AUC) for continuous parameters were analyzed. We also examined the coefficients of variation (CoV) for sensitivity estimates, as these have been used to test and quantify the influence of optic disc size on diagnostic accuracy. The influence of optic disc size on the glaucoma diagnosis was assessed by the likelihood ratio chi-square test. Results Among the continuous parameters, the best diagnostic accuracy was seen for the average rim area, which had an AUC of 0.96. The most reliable factor across the disc size groups was the rim area (CoV, 2.8%). The diagnostic accuracy of the rim area did not appear to be influenced by optic disc size (P = 0.17). Conclusions The high diagnostic accuracy of the rim area demonstrated by Cirrus HD-OCT for the quantitative assessment of the ONH was not significantly affected by disc size in this study.


Journal of Ophthalmology | 2018

The Effect of Steep Trendelenburg Positioning on Retinal Structure and Function during Robotic-Assisted Laparoscopic Procedures

Kazuyuki Hirooka; Kaori Ukegawa; Eri Nitta; Nobufumi Ueda; Yushi Hayashida; Hiromi Hirama; Rikiya Taoka; Yuma Sakura; Mari Yamasaki; Hiroyuki Tsunemori; Mikio Sugimoto; Yoshiyuki Kakehi

Purpose Robotic-assisted laparoscopic radical prostatectomy (RALP) has become a standard treatment choice for localized prostate cancer. RALP requires a steep Trendelenburg position, which leads to a significant increase in intraocular pressure (IOP). This study evaluated the effect on the retinal structure and function in patients undergoing RALP. Methods Standard automated perimetry (SAP) and optical coherence tomography (OCT) were performed in 20 males scheduled for RALP at 1 month and 1 day before the operation and at 1 and 3 months after the operation. IOP measurements were made in the supine position at 5 min after intubation under general anesthesia (T1), at 6 discrete time points (5, 30, 60, 120, 180, and 240 min; T2-7), and at 5 min after returning to a horizontal supine position (T8). Serial retinal nerve fiber layer (RNFL) thicknesses and visual field progression were assessed using the guided progression analysis software program. RNFL thickness progression and visual field progression were evaluated by event analysis. Results Average IOP (mmHg) for each time point was as follows: T1 = 12.3 ± 2.6, T2 = 20.4 ± 4.2, T3 = 23.3 ± 3.8, T4 = 24.0 ± 3.2, T5 = 24.3 ± 3.4, T6 = 27.1 ± 7.2, T7 = 29.8 ± 8.7, and T8 = 20.1 ± 4.4. During RALP, IOP significantly increased. There was no progression of the visual field and RNFL thickness after surgery or any other ocular complications found. Conclusions Although IOP significantly increased during RALP, there were no significant changes in the retinal structure and function between the pre- and postoperation observations.


Acta Ophthalmologica | 2018

Oxygen venular saturation correlates with a functional loss in primary open‐angle glaucoma and normal‐tension glaucoma patients

Takeru Shimazaki; Kazuyuki Hirooka; Yuki Nakano; Eri Nitta; Kaori Ukegawa; Akitaka Tsujikawa

To investigate whether there are differences in retinal oxygen saturation in upper and lower visual field hemispheres in primary open‐angle glaucoma (POAG) and in normal‐tension glaucoma (NTG).


Advances in Therapy | 2016

Additive Intraocular Pressure Lowering Effects of the Rho Kinase Inhibitor, Ripasudil in Glaucoma Patients Not Able to Obtain Adequate Control After Other Maximal Tolerated Medical Therapy

Shino Sato; Kazuyuki Hirooka; Eri Nitta; Kaori Ukegawa; Akitaka Tsujikawa


BMC Ophthalmology | 2017

Vision-related quality of life following glaucoma filtration surgery

Kazuyuki Hirooka; Eri Nitta; Kaori Ukegawa; Akitaka Tsujikawa


International Ophthalmology | 2018

Visual acuity and corneal higher-order aberrations after EX-PRESS or trabeculectomy, and the determination of associated factors that influence visual function

Nobuko Kobayashi; Kazuyuki Hirooka; Eri Nitta; Kaori Ukegawa; Akitaka Tsujikawa

Collaboration


Dive into the Kaori Ukegawa's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge