Karina Lebel
Université de Sherbrooke
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Karina Lebel.
PLOS ONE | 2013
Karina Lebel; Patrick Boissy; Mathieu Hamel; Christian Duval
Background Inertial measurement of motion with Attitude and Heading Reference Systems (AHRS) is emerging as an alternative to 3D motion capture systems in biomechanics. The objectives of this study are: 1) to describe the absolute and relative accuracy of multiple units of commercially available AHRS under various types of motion; and 2) to evaluate the effect of motion velocity on the accuracy of these measurements. Methods The criterion validity of accuracy was established under controlled conditions using an instrumented Gimbal table. AHRS modules were carefully attached to the center plate of the Gimbal table and put through experimental static and dynamic conditions. Static and absolute accuracy was assessed by comparing the AHRS orientation measurement to those obtained using an optical gold standard. Relative accuracy was assessed by measuring the variation in relative orientation between modules during trials. Findings Evaluated AHRS systems demonstrated good absolute static accuracy (mean error < 0.5o) and clinically acceptable absolute accuracy under condition of slow motions (mean error between 0.5o and 3.1o). In slow motions, relative accuracy varied from 2o to 7o depending on the type of AHRS and the type of rotation. Absolute and relative accuracy were significantly affected (p<0.05) by velocity during sustained motions. The extent of that effect varied across AHRS. Interpretation Absolute and relative accuracy of AHRS are affected by environmental magnetic perturbations and conditions of motions. Relative accuracy of AHRS is mostly affected by the ability of all modules to locate the same global reference coordinate system at all time. Conclusions Existing AHRS systems can be considered for use in clinical biomechanics under constrained conditions of use. While their individual capacity to track absolute motion is relatively consistent, the use of multiple AHRS modules to compute relative motion between rigid bodies needs to be optimized according to the conditions of operation.
PLOS ONE | 2015
Karina Lebel; Patrick Boissy; Mathieu Hamel; Christian Duval
Background Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been extensively documented. The objectives of this study are: 1) to assess the change in absolute and relative accuracy of multiple units of 3 commercially available AHRS over time; and 2) to identify different sources of errors affecting AHRS accuracy and to document how they may affect the measurements over time. Methods This study used an instrumented Gimbal table on which AHRS modules were carefully attached and put through a series of velocity-controlled sustained motions including 2 minutes motion trials (2MT) and 12 minutes multiple dynamic phases motion trials (12MDP). Absolute accuracy was assessed by comparison of the AHRS orientation measurements to those of an optical gold standard. Relative accuracy was evaluated using the variation in relative orientation between modules during the trials. Findings Both absolute and relative accuracy decreased over time during 2MT. 12MDP trials showed a significant decrease in accuracy over multiple phases, but accuracy could be enhanced significantly by resetting the reference point and/or compensating for initial Inertial frame estimation reference for each phase. Interpretation The variation in AHRS accuracy observed between the different systems and with time can be attributed in part to the dynamic estimation error, but also and foremost, to the ability of AHRS units to locate the same Inertial frame. Conclusions Mean accuracies obtained under the Gimbal table sustained conditions of motion suggest that AHRS are promising tools for clinical mobility assessment under constrained conditions of use. However, improvement in magnetic compensation and alignment between AHRS modules are desirable in order for AHRS to reach their full potential in capturing clinical outcomes.
Prehospital Emergency Care | 2015
Ian Shrier; Patrick Boissy; Karina Lebel; John Boulay; Eli Segal; J. Scott Delaney; L. Charlene Vacon; Russell Steele
Abstract Objectives. To compare paramedics’ ability to minimize cervical spine motion during patient transfer onto a vacuum mattress with two stabilization techniques (head squeeze vs. trap squeeze) and two transfer methods (log roll with one assistant (LR2) vs. 3 assistants (LR4)). Methods. We used a crossover design to minimize bias. Each lead paramedic performed 10 LR2 transfers and 10 LR4 transfers. For each of the 10 LR2 and 10 LR4 transfers, the lead paramedic stabilized the cervical spine using the head squeeze technique five times and the trap squeeze technique five times. We randomized the order of the stabilization techniques and LR2/LR4 across lead paramedics to avoid a practice or fatigue effect with repeated trials. We measured relative cervical spine motion between the head and trunk using inertial measurement units placed on the forehead and sternum. Results. On average, total motion was 3.9° less with three assistants compared to one assistant (p = 0.0002), and 2.8° less with the trap squeeze compared to the head squeeze (p = 0.002). There was no interaction between the transfer method and stabilization technique. When examining specific motions in the six directions, the trap squeeze generally produced less lateral flexion and rotation motion but allowed more extension. Examining within paramedic differences, some paramedics were clearly more proficient with the trap squeeze technique and others were clearly more proficient with the head squeeze technique. Conclusion. Paramedics performing a log roll with three assistants created less motion compared to a log roll with only one assistant, and using the trap squeeze stabilization technique resulted in less motion than the head squeeze technique but the clinical relevance of the magnitude remains unclear. However, large individual differences suggest future paramedic training should incorporate both best evidence practice as well as recognition that there may be individual differences between paramedics.
Sensors | 2016
Karina Lebel; Patrick Boissy; Hung Nguyen; Christian Duval
Clinical mobility assessment is traditionally performed in laboratories using complex and expensive equipment. The low accessibility to such equipment, combined with the emerging trend to assess mobility in a free-living environment, creates a need for body-worn sensors (e.g., inertial measurement units—IMUs) that are capable of measuring the complexity in motor performance using meaningful measurements, such as joint orientation. However, accuracy of joint orientation estimates using IMUs may be affected by environment, the joint tracked, type of motion performed and velocity. This study investigates a quality control (QC) process to assess the quality of orientation data based on features extracted from the raw inertial sensors’ signals. Joint orientation (trunk, hip, knee, ankle) of twenty participants was acquired by an optical motion capture system and IMUs during a variety of tasks (sit, sit-to-stand transition, walking, turning) performed under varying conditions (speed, environment). An artificial neural network was used to classify good and bad sequences of joint orientation with a sensitivity and a specificity above 83%. This study confirms the possibility to perform QC on IMU joint orientation data based on raw signal features. This innovative QC approach may be of particular interest in a big data context, such as for remote-monitoring of patients’ mobility.
IEEE Transactions on Neural Systems and Rehabilitation Engineering | 2018
Hung Nguyen; Karina Lebel; Sarah Bogard; Etienne Goubault; Patrick Boissy; Christian Duval
Wearable sensors such as inertial measurement units (IMUs) have been widely used to measure the quantity of physical activities during daily living in healthy and people with movement disorders through activity classification. These sensors have the potential to provide valuable information to evaluate the quality of the movement during the activities of daily living (ADL), such as walking, sitting down, and standing up, which could help clinicians to monitor rehabilitation and pharmaceutical interventions. However, high accuracy in the detection and segmentation of these activities is necessary for proper evaluation of the quality of the performance within a given segment. This paper presents algorithms to process IMU data, to detect and segment unstructured ADL in people with Parkinson’s disease (PD) in simulated free-living environment. The proposed method enabled the detection of 1610 events of ADL performed by nine community dwelling older adults with PD under simulated free-living environment with 90% accuracy (sensitivity = 90.8%, specificity = 97.8%) while segmenting these activities within 350 ms of the “gold-standard” manual segmentation. These results demonstrate the robustness of the proposed method to eventually be used to automatically detect and segment ADL in free-living environment in people with PD. This could potentially lead to a more expeditious evaluation of the quality of the movement and administration of proper corrective care for patients who are under physical rehabilitation and pharmaceutical intervention for movement disorders.
Journal of Neuroengineering and Rehabilitation | 2017
Hung Nguyen; Karina Lebel; Patrick Boissy; Sarah Bogard; Etienne Goubault; Christian Duval
BackgroundWearable sensors have the potential to provide clinicians with access to motor performance of people with movement disorder as they undergo intervention. However, sensor data often have to be manually classified and segmented before they can be processed into clinical metrics. This process can be time consuming. We recently proposed detection and segmentation algorithms based on peak detection using Inertial Measurement Units (IMUs) to automatically identify and isolate common activities during daily living such as standing up, walking, turning, and sitting down. These algorithms were developed using a homogenous population of healthy older adults. The aim of this study was to investigate the transferability of these algorithms in people with Parkinson’s disease (PD).MethodsA modified Timed Up And Go task was used since it is comprised of these activities, all performed in a continuous fashion. Twelve older adults diagnosed with early PD (Hoehn & Yahr ≤ 2) were recruited for the study and performed three trials of a 10 and 5-m TUG during OFF state. They were outfitted with 17 IMUs covering each body segment. Raw data from IMUs were detrended, normalized and filtered to reveal kinematics peaks that corresponded to different activities. Segmentation was accomplished by identifying the first minimum or maximum to the right and the left of these peaks. Segmentation times were compared to results from two examiners who visually segmented the activities. Specificity and sensitivity were used to evaluate the accuracy of the detection algorithms.ResultsUsing the same IMUs and algorithms developed in the previous study, we were able to detect these activities with 97.6% sensitivity and 92.7% specificity (n = 432) in PD population. However, with modifications to the IMUs selection, we were able to detect these activities with 100% accuracy. Similarly, applying the same segmentation to PD population, we were able to isolate these activities within ~500 ms of the visual segmentation. Re-optimizing the filtering frequencies, we were able to reduce this difference to ~400 ms.ConclusionsThis study demonstrates the agility and transferability of using a system of IMUs to accurately detect and segment activities in daily living in people with movement disorders.
Frontiers in Bioengineering and Biotechnology | 2017
Karina Lebel; Hung Nguyen; Christian Duval; Réjean Plamondon; Patrick Boissy
Background Turning is a challenging mobility task requiring coordination and postural stability. Optimal turning involves a cranio-caudal sequence (i.e., the head initiates the motion, followed by the trunk and the pelvis), which has been shown to be altered in patients with neurodegenerative diseases, such as Parkinson’s disease as well as in fallers and frails. Previous studies have suggested that the cranio-caudal sequence exhibits a specific signature corresponding to the adopted turn strategy. Currently, the assessment of cranio-caudal sequence is limited to biomechanical labs which use camera-based systems; however, there is a growing trend to assess human kinematics with wearable sensors, such as attitude and heading reference systems (AHRS), which enable recording of raw inertial signals (acceleration and angular velocity) from which the orientation of the platform is estimated. In order to enhance the comprehension of complex processes, such as turning, signal modeling can be performed. Aim The current study investigates the use of a kinematic-based model, the sigma-lognormal model, to characterize the turn cranio-caudal signature as assessed with AHRS. Methods Sixteen asymptomatic adults (mean age = 69.1 ± 7.5 years old) performed repeated 10-m Timed-Up-and-Go (TUG) with 180° turns, at varying speed. Head and trunk kinematics were assessed with AHRS positioned on each segments. Relative orientation of the head to the trunk was then computed for each trial and relative angular velocity profile was derived for the turn phase. Peak relative angle (variable) and relative velocity profiles modeled using a sigma-lognormal approach (variables: Neuromuscular command amplitudes and timing parameters) were used to extract and characterize the cranio-caudal signature of each individual during the turn phase. Results The methodology has shown good ability to reconstruct the cranio-caudal signature (signal-to-noise median of 17.7). All variables were robust to speed variations (p > 0.124). Peak relative angle and commanded amplitudes demonstrated moderate to strong reliability (ICC between 0.640 and 0.808). Conclusion The cranio-caudal signature assessed with the sigma-lognormal model appears to be a promising avenue to assess the efficiency of turns.
Journal of Healthcare Engineering | 2018
Karina Lebel; Vanessa Chenel; John Boulay; Patrick Boissy
Patients with suspected spinal cord injuries undergo numerous transfers throughout treatment and care. Effective c-spine stabilization is crucial to minimize the impacts of the suspected injury. Healthcare professionals are trained to perform those transfers using simulation; however, the feedback on the manoeuvre is subjective. This paper proposes a quantitative approach to measure the efficacy of the c-spine stabilization and provide objective feedback during training. Methods. 3D wearable motion sensors are positioned on a simulated patient to capture the motion of the head and trunk during a training scenario. Spatial and temporal indicators associated with the motion can then be derived from the signals. The approach was developed and tested on data obtained from 21 paramedics performing the log-roll, a transfer technique commonly performed during prehospital and hospital care. Results. In this scenario, 55% of the c-spine motion could be explained by the difficulty of rescuers to maintain head and trunk alignment during the rotation part of the log-roll and their difficulty to initiate specific phases of the motion synchronously. Conclusion. The proposed quantitative approach has the potential to be used for personalized feedback during training sessions and could even be embedded into simulation mannequins to provide an innovative training solution.
Gait & Posture | 2018
Karina Lebel; Mathieu Hamel; Christian Duval; Hung Nguyen; Patrick Boissy
Joint kinematics can be assessed using orientation estimates from Attitude and Heading Reference Systems (AHRS). However, magnetically-perturbed environments affect the accuracy of the estimated orientations. This study investigates, both in controlled and human mobility conditions, a trial calibration technic based on a 2D photograph with a pose estimation algorithm to correct initial difference in AHRS Inertial reference frames and improve joint angle accuracy. In controlled conditions, two AHRS were solidly affixed onto a wooden stick and a series of static and dynamic trials were performed in varying environments. Mean accuracy of relative orientation between the two AHRS was improved from 24.4° to 2.9° using the proposed correction method. In human conditions, AHRS were placed on the shank and the foot of a participant who performed repeated trials of straight walking and walking while turning, varying the level of magnetic perturbation in the starting environment and the walking speed. Mean joint orientation accuracy went from 6.7° to 2.8° using the correction algorithm. The impact of starting environment was also greatly reduced, up to a point where one could consider it as non-significant from a clinical point of view (maximum mean difference went from 8° to 0.6°). The results obtained demonstrate that the proposed method improves significantly the mean accuracy of AHRS joint orientation estimations in magnetically-perturbed environments and can be implemented in post processing of AHRS data collected during biomechanical evaluation of motion.
Frontiers in Neurology | 2018
Karina Lebel; Christian Duval; Hung Phuc Nguyen; Réjean Plamondon; Patrick Boissy
Background Turning is a challenging mobility task requiring proper planning, coordination, and postural stability to be executed efficiently. Turn deficits can impair mobility and lead to falls in patients with neurodegenerative disease, such as Parkinson’s disease (PD). It was previously shown that the cranio-caudal sequence involved during a turn (i.e., motion is initiated by the head, followed by the trunk) exhibits a signature that can be captured using an inertial system and analyzed through the Kinematics Theory. The so-called cranio-caudal kinematic turn signature (CCKS) metrics derived from this approach could, therefore, be a promising avenue to develop and track markers to measure early mobility deficits. Objective The current study aims at exploring the discriminative validity and sensitivity of CCKS metrics extracted during turning tasks performed by patients with PD. Methods Thirty-one participants (16 asymptomatic older adults (OA): mean age = 69.1 ± 7.5 years old; 15 OA diagnosed with early PD ON and OFF medication, mean age = 65.8 ± 8.4 years old) performed repeated timed up-and–go (TUG) tasks while wearing a portable inertial system. CCKS metrics (maximum head to trunk angle reached and commanded amplitudes of the head to trunk neuromuscular system, estimated from a sigma-lognormal model) were extracted from kinematic data recorded during the turn phase of the TUG tasks. For comparison purposes, common metrics used to analyze the quality of a turn using inertial systems were also calculated over the same trials (i.e., the number of steps required to complete the turn and the turn mean and maximum velocities). Results All CCKS metrics discriminated between OA and patients (p ≤ 0.041) and were sensitive to change in PD medication state (p ≤ 0.033). Common metrics were also able to discriminate between OA and patients (p < 0.014), but they were unable to capture the change in medication state this early in the disease (p ≥ 0.173). Conclusion The enhanced sensitivity to change of the proposed CCKS metrics suggests a potential use of these metrics for mobility impairments identification and fluctuation assessment, even in the early stages of the disease.