Katherine Scollan
Oregon State University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Katherine Scollan.
Veterinary Clinical Pathology | 2015
Craig G. Ruaux; Katherine Scollan; Jan S. Suchodolski; Jörg M. Steiner; D. David Sisson
BACKGROUND The N-terminal fragment of the prohormone B-type natriuretic peptide (NT-proBNP) and cardiac troponin-I are candidate biomarkers for cardiac disease in dogs. The degree of biologic variation in these biomarkers has not previously been reported in healthy dogs or dogs with mitral regurgitation. OBJECTIVES The purpose of the study was to derive estimates of intrinsic biologic variability and reference change values for NT-proBNP and cardiac troponin-I in healthy dogs and dogs with mitral regurgitation grade IB and II according to the International Small Animal Cardiac Health Council (ISACHC) grading system. METHODS Plasma and sera were collected weekly for up to 7 weeks from 12 control dogs and 9 dogs with mitral regurgitation. NT-proBNP and troponin-I (C-TnI) concentrations were determined. Indices of biologic variation such as reciprocal index of individuality (r-IoI) and reference change values (RCV) were calculated in both the groups. RESULTS Individuality was high in control dogs and dogs with grade IB and II mitral valve regurgitation for both C-TnI (r-IoI 1.6 and 2) and NT-proBNP (1.5 and 2.7), while the 2-sided RCV for NT-proBNP was significantly lower in dogs with mitral regurgitation (52.5% vs 99.4%, P<0.01.). CONCLUSIONS High individuality of these cardiac biomarkers suggests that, following diagnosis, these assays are best interpreted by serial determination in individual canine patients rather than by comparison to a population-based reference interval. The smaller RCV values for dogs with mitral regurgitation suggest that smaller relative changes in NT-proBNP are clinically meaningful in these patients.
Journal of Veterinary Cardiology | 2014
Katherine Scollan; D. David Sisson
Contrast enhanced, multi-detector computed tomography (MDCT) is a useful diagnostic imaging modality that has become increasingly available in veterinary medicine. Multi-planar and three-dimensional reconstructions allow accurate and comprehensive assessment of cardiac and vascular lesions with short image acquisition times. ECG-gated, contrast enhanced MDCT was used to assess the lesion extent and therapeutic options in a case of aortic dissection diagnosed in a hypertensive cat.
American Journal of Veterinary Research | 2013
Katherine Scollan; Barret J. Bulmer; D. David Sisson
OBJECTIVE To validate the use of a human enzyme immunoassay (EIA) kit for measurement of plasma antidiuretic hormone (ADH) concentration in dogs and evaluate plasma ADH concentrations in dogs with congestive heart failure (CHF) attributable to acquired cardiac disease, compared with findings in healthy dogs. ANIMALS 6 healthy dogs and 12 dogs with CHF as a result of chronic degenerative valve disease or dilated cardiomyopathy. PROCEDURES Plasma samples from the 6 healthy dogs were pooled and used to validate the EIA kit for measurement of plasma ADH concentration in dogs by assessing intra-assay precision, dilutional linearity, and spiking recovery. Following validation, plasma ADH concentrations were measured in the 6 healthy dogs and in the 12 dogs with CHF for comparison. RESULTS The EIA kit measured ADH concentrations in canine plasma samples with acceptable intra-assay precision, dilutional linearity, and spiking recovery. The intra-assay coefficient of variation was 11%. By use of this assay, the median plasma concentration of ADH in dogs with CHF was 6.15 pg/mL (SD, 3.2 pg/mL; range, 4.18 to 15.47 pg/mL), which was significantly higher than the median concentration in healthy dogs (3.67 pg/mL [SD, 0.93 pg/mL; range, 3.49 to 5.45 pg/mL]). CONCLUSIONS AND CLINICAL RELEVANCE Plasma ADH concentrations in dogs can be measured with the tested EIA kit. Plasma ADH concentrations were higher in dogs with CHF induced by acquired cardiac disease than in healthy dogs. This observation provides a basis for future studies evaluating circulating ADH concentrations in dogs with developing heart failure.
Journal of Veterinary Cardiology | 2016
Susanne M. Stieger-Vanegas; Katherine Scollan; L. Meadows; D. David Sisson; John W. Schlipf; Riebold Tw; Christiane V. Löhr
BACKGROUND The prevalence of congenital heart disease is higher in camelids than in other domestic species and complex defects, often involving the great vessels, are more frequently encountered in llamas and alpacas than in other species. Some of these complex defects can be difficult to accurately characterize via echocardiography, the most commonly used diagnostic imaging technique to evaluate the heart in veterinary patients. Contrast-enhanced, electrocardiogram (ECG)-gated computed tomography (CT) has proven utility for the evaluation of human patients with certain congenital heart defects, including those with conotruncal septation defects and other abnormalities involving the formation of the great vessels. METHODS Three alpaca crias, 4 days, 5 weeks and 14 months of age were clinically evaluated and subjected to a complete color-flow Doppler echocardiogram and a contrast-enhanced ECG-gated CT. RESULTS These alpacas exhibited a variety of clinical findings including lethargy, failure to thrive, exercise intolerance, heart murmur, and/or respiratory difficulty. All three crias were subsequently diagnosed with complex cardiac defects including pulmonary atresia with a ventricular septal defect (VSD), a truncus arteriosus with a large VSD, and a double outlet right ventricle with a large VSD and aortic hypoplasia. In each case, the diagnosis was confirmed by postmortem examination. CONCLUSION Color flow echocardiographic evaluation identified all of the intra-cardiac lesions and associated flow anomalies but contrast-enhanced ECG-gated CT permitted more accurate assessment of the morphology of the extracardiac structures and permitted a more precise determination of the exact nature and anatomy of the great vessels.
Journal of Veterinary Internal Medicine | 2015
Katherine Scollan; B. Bottorff; Susanne M. Stieger-Vanegas; Sarah Nemanic; D. David Sisson
Background Contrast‐enhanced multidetector computed tomography (MDCT) allows high spatial and temporal resolution imaging of cardiac, thoracic, and abdominal structures. Accurate determination of the cause of pericardial effusion (PE) is essential to providing appropriate treatment and prognosis. Echocardiography and pericardial fluid analysis may not differentiate between causes of PE and cannot identify extracardiac metastasis. Hypothesis/Objectives Describe the thoracic and abdominal MDCT findings and evaluate the utility of MDCT to differentiate between neoplastic and nonneoplastic causes of PE in dogs. Animals Eleven client‐owned dogs with PE diagnosed by echocardiography. Methods Prospective observational study. Transthoracic echocardiography (TTE), 3‐view thoracic radiography, and contrast‐enhanced thoracic and abdominal MDCT images were evaluated for the presence of cardiac masses, pulmonary metastases, and abdominal masses. Histopathology in 5 dogs and survival analysis in all dogs were evaluated. Results A neoplastic cause was identified in 6/11 dogs and a nonneoplastic cause was identified in 5/11. Cardiac MDCT findings were consistent with TTE findings in all dogs with right atrial (5/5) and heart base masses (1/1). Pulmonary metastases were identified in 1/11 dogs by thoracic radiography and in 2/11 dogs by MDCT. MDCT identified splenic or hepatic lesions consistent with neoplasia in 6/11 and 5/11 dogs, respectively. Focal MDCT pericardial changes at the pericardiocentesis site were noted in 3/11 dogs. Conclusions and Clinical Importance Multidetector computed tomography did not improve the detection of cardiac masses in dogs with PE over echocardiography. The benefit of MDCT was primarily in the detection of pulmonary metastases and extracardiac lesions using a single imaging modality.
Journal of Veterinary Cardiology | 2011
Katherine Scollan; Brenda Salinardi; Barret J. Bulmer; D. David Sisson
Anomalies of conotruncal septation are rare in dogs and uncommon in humans. Congenital conotruncal defects most commonly reported in veterinary medicine include aorto-pulmonary window and persistent truncus arteriosus. We report a case of an anomalous vessel connecting the ascending aorta to the right pulmonary artery causing left-to-right shunting, left-sided volume overload, and pulmonary overcirculation. Transesophageal echocardiography, cardiac catheterization, and contrast-enhanced computed tomography assisted in the diagnosis and facilitated the surgical correction of the anomalous vessel. The authors hypothesize this defect represents an unusual anomalous vessel connecting the ascending aorta to the right pulmonary artery.
Journal of Veterinary Cardiology | 2016
S.T. Koo; Nicole L. LeBlanc; Katherine Scollan; D. David Sisson
A 2-year old intact male Collie dog presented to the cardiology service at Oregon State University for evaluation of cyanosis and suspected congenital cardiac disease. Echocardiography revealed a constellation of cardiac abnormalities including a single large vessel exiting the right ventricle with a diminutive left ventricular outflow tract, a ventricular septal defect, and marked concentric right ventricular hypertrophy with moderate right atrial dilation. Cardiac-gated computed tomography confirmed the previous anomalies in addition to supporting a diagnosis of complete transposition of the great arteries, double outlet right ventricle, and pulmonic hypoplasia with a single coronary ostium. Prominent bronchoesophageal collateral vessels were concurrently identified. Clinically, the dog was stable despite mild cyanosis that worsened with exercise; no intervention was elected at the time. This case report describes a rare combination of congenital cardiac defects and the usefulness of cardiac-gated cross-sectional imaging in the anatomic diagnosis.
American Journal of Veterinary Research | 2017
Nicole L. LeBlanc; Katherine Scollan; Susanne M. Stieger-Vanegas
OBJECTIVE To evaluate the accuracy of cardiac output (CO) estimated by use of ECG-gated multidetector CT (MDCT) and 1-, 2-, and 3-D echocardiography and by use of thermodilution. ANIMALS 6 healthy hound-cross dogs. PROCEDURES Electrocardiogram-gated contrast-enhanced 64-slice MDCT and 1-, 2-, and 3-D echocardiography were performed on each dog. The CO for ECG-gated MDCT was calculated as volumetric measurements of stroke volume multiplied by mean heart rate. Echocardiographic left ventricle end-diastolic volumes and end-systolic volumes were measured by use of the Teichholz method (1-D echocardiography) and a single-plane method of disks (2-D echocardiography). Real-time 3-D echocardiographic left ventricle volumes were measured with 3-D functional analysis software on right long-axis and left apical views. The CO of each dog was measured in triplicate by use of thermodilution. Mean CO values, correlations, and limits of agreement for MDCT, echocardiographic modalities, and thermodilution were compared. RESULTS CO measured by use of MDCT, 2-D echocardiography, and 3-D echocardiography had the strongest correlations with CO measured by use of thermodilution. No significant difference in CO was detected between MDCT, any echocardiographic method, and thermodilution. Bland-Altman analysis revealed a systematic underestimation of CO derived by use of MDCT, 2-D echocardiography, and 3-D echocardiography. CONCLUSIONS AND CLINICAL RELEVANCE Use of MDCT, 2-D echocardiography, and 3-D echocardiography to measure CO in healthy dogs was feasible. Measures of CO determined by use of 3-D echocardiography on the right long-axis view were strongly correlated with CO determined by use of thermodilution, with little variance and slight underestimation.
Journal of Feline Medicine and Surgery Open Reports | 2015
Nicole L. LeBlanc; Katherine Scollan
Case summary A 4-year-old male neutered domestic shorthair cat was presented to the Oregon State University cardiology service for suspected pericardial effusion. Cardiac tamponade was documented and pericardiocentesis yielded purulent fluid with cytologic results supportive of bacterial pericarditis. The microbial population consisted of Pasteurella multocida, Actinomyces canis, Fusobacterium and Bacteroides species. Conservative management was elected consisting of intravenous antibiotic therapy with ampicillin sodium/sulbactam sodium and metronidazole for 48 h followed by 4 weeks of oral antibiotics. Re-examination 3 months after the initial incident indicated no recurrence of effusion and the cat remained free of clinical signs 2 years after presentation. Relevance and novel information Bacterial pericarditis is a rare cause of pericardial effusion in cats. Growth of P multocida, A canis, Fusobacterium and Bacteroides species has not previously been documented in feline septic pericarditis. Conservative management with broad-spectrum antibiotics may be considered when further diagnostic imaging or exploratory surgery to search for a primary nidus of infection is not feasible or elected.
Journal of Veterinary Cardiology | 2014
Nicole L. LeBlanc; Katherine Scollan; D. David Sisson
A 6-year-old male castrated labrador retriever presented with endocardial pacemaker infection following migration and subsequent repositioning of the pulse generator. An epicardial lead and pulse generator were surgically implanted and the endocardial lead could not be removed with manual traction. The endocardial lead was severed, anchored, and abandoned at the thoracic inlet. The patient presented 4 months later with endocardial lead migration, bacteremia, and suspected glomerulonephritis. The endocardial pacemaker lead was transvenously extracted using a mechanical dilator sheath and locking stylet. This report of transvenous pacemaker lead extraction in a dog addresses the challenges and describes recent advances in extraction devices.