Medical Imaging 2003: Physics of Medical Imaging | 2003
Shigeyuki Ikeda; Katsumi Suzuki; Ken Ishikawa; Richard E. Colbeth; Chris Webb; Saori Tanaka; Kenji Okusako
We developed prototype Digital Subtraction Angiography (DSA) System with a new large area FPD. Dynamic range, MTF, Contrast ratio and line noise were much improved. The improved FPD is a scintillator-type detector, and has a 40 x 30 cm active area, 2048 x 1536 matrix with 194um pixel pitch. The Prototype DSA system has two x-ray detectors, the FPD and the I.I.-CCD camera, and we can choose them on demand. All images captured from both detectors at 3 frames/sec in DSA mode and 30 frames/sec in Fluoroscopy mode are forwarded to our image-processing unit. We applied the new DSA system to more than 150 studies and compared the results with images from the I.I.-CCD. In DSA mode, FPD System, which has a wide dynamic range, large detecting area, and good contrast ratio yielded superior angiogram images compared with the I.I-CCD system. In Fluoroscopy mode, we improved line noise and increased the contrast of catheters and guide wires with a new image processing technique. With these improvements, the image quality of the FPD System is superior to the I.I.-CCD system at the exposure range of over 2uR/frame (17.4 nGy/frame).
Medical Imaging 2003: Physics of Medical Imaging | 2003
Kenji Okusako; Masachika Shogaki; Katsuhisa Tanaka; Kouji Yokoyama; Takao Ichida; Kazuo Okuyama; Hiroaki Kudoh; Saori Tanaka; Kenji Nakamura; Shigeyuki Ikeda
Authors could have a clinical experience to use an angiographic system incorporating FPD. This system possesses both FPD and I.I.-CCD detectors and is capable of conducting imaging in the same geometry for both detectors. We made measurement of basic physical characteristics of this system and visual evaluation using arteriographies of lower limbs processed by IVDSA, and confirmed that FPD is an excellent detector in angiographic examination. In the foreseeable future, angiographic system will be replaced by FPD system.
Nihon Hōshasen Gijutsu Gakkai zasshi | 2009
Takao Ichida; Shohei Sasaki; Masachika Shougaki; Kenji Okusako; Takayoshi Ogawa; Kouji Yokoyama; Emi Sasagawa; Mamiko Nakajima; Ryousei Nakada; Minoru Hosogai; Saori Tanaka; Kenji Nakamura
Japanese Journal of Radiological Technology | 2005
Takao Ichida; Minoru Hosogai; Takayoshi Ogawa; Eiji Yamada; Masachika Shougaki; Kenji Okusako; Hironao Masai; Kouji Yokoyama; Kazuo Okuyama; Masakatsu Hatagawa
Nihon Hōshasen Gijutsu Gakkai zasshi | 2004
Takao Ichida; Kenji Okusako; Kouji Yokoyama; Masachika Shougaki; Takayoshi Ogawa; Hideki Kawahata; Takehisa Nasu; Minoru Hosogai; Kazuo Okuyama; Masakatsu Hatagawa
Nihon Hōshasen Gijutsu Gakkai zasshi | 2004
Takao Ichida; Minoru Hosogai; Kouji Yokoyama; Takayoshi Ogawa; Kenji Okusako; Masachika Shougaki; Hironao Masai; Eiji Yamada; Kazuo Okuyama; Masakatsu Hatagawa
Japanese Journal of Radiological Technology | 1998
Takao Ichida; Norihisa Masai; Atushi Nakamura; Kenji Okusako; Masachika Shougaki; Tetuhiro Kubota; Hiroaki Kudoh
Japanese Journal of Radiological Technology | 1995
Kenji Okusako; Minoru Hosogai; Takao Ichida; Hideki Kawahata; Atsushi Nakamura; Hiroaki Kudoh
Japanese Journal of Radiological Technology | 1995
Hideki Kawahata; Kenji Kishimoto; Masachika Shogaki; Kenji Okusako; Masakatsu Hatagawa
Japanese Journal of Radiological Technology | 1995
Hideki Kawahata; Minoru Hosogai; Takao Ichida; Atsuhsi Nakamura; Kenji Okusako; Hiroaki Kudoh