Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kenneth E. Rosenzweig is active.

Publication


Featured researches published by Kenneth E. Rosenzweig.


International Journal of Radiation Oncology Biology Physics | 1996

Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation

Joseph Hanley; Marc M. Debois; Dennis Mah; G Mageras; Adam Raben; Kenneth E. Rosenzweig; Borys Mychalczak; Lawrence H. Schwartz; Paul J. Gloeggler; Wendell Lutz; C. Clifton Ling; Steven A. Leibel; Zvi Fuks; Gerald J. Kutcher

PURPOSE/OBJECTIVE This study evaluates the dosimetric benefits and feasibility of a deep inspiration breath-hold (DIBH) technique in the treatment of lung tumors. The technique has two distinct features--deep inspiration, which reduces lung density, and breath-hold, which immobilizes lung tumors, thereby allowing for reduced margins. Both of these properties can potentially reduce the amount of normal lung tissue in the high-dose region, thus reducing morbidity and improving the possibility of dose escalation. METHODS AND MATERIALS Five patients treated for non-small cell lung carcinoma (Stage IIA-IIIB) received computed tomography (CT) scans under 4 respiration conditions: free-breathing, DIBH, shallow inspiration breath-hold, and shallow expiration breath-hold. The free-breathing and DIBH scans were used to generate 3-dimensional conformal treatment plans for comparison, while the shallow inspiration and expiration scans determined the extent of tumor motion under free-breathing conditions. To acquire the breath-hold scans, the patients are brought to reproducible respiration levels using spirometry, and for DIBH, modified slow vital capacity maneuvers. Planning target volumes (PTVs) for free-breathing plans included a margin for setup error (0.75 cm) plus a margin equal to the extent of tumor motion due to respiration (1-2 cm). Planning target volumes for DIBH plans included the same margin for setup error, with a reduced margin for residual uncertainty in tumor position (0.2-0.5 cm) as determined from repeat fluoroscopic movies. To simulate the effects of respiration-gated treatments and estimate the role of target immobilization alone (i.e., without the benefit of reduced lung density), a third plan is generated from the free-breathing scan using a PTV with the same margins as for DIBH plans. RESULTS The treatment plan comparison suggests that, on average, the DIBH technique can reduce the volume of lung receiving more than 25 Gy by 30% compared to free-breathing plans, while respiration gating can reduce the volume by 18%. The DIBH maneuver was found to be highly reproducible, with intra breath-hold reproducibility of 1.0 (+/- 0.9) mm and inter breath-hold reproducibility of 2.5 (+/- 1.6) mm, as determined from diaphragm position. Patients were able to perform 10-13 breath-holds in one session, with a comfortable breath-hold duration of 12-16 s. CONCLUSION Patients tolerate DIBH maneuvers well and can perform them in a highly reproducible fashion. Compared to conventional free-breathing treatment, the DIBH technique benefits from reduced margins, as a result of the suppressed target motion, as well as a decreased lung density; both contribute to moving normal lung tissue out of the high-dose region. Because less normal lung tissue is irradiated to high dose, the possibility for dose escalation is significantly improved.


International Journal of Radiation Oncology Biology Physics | 2000

The deep inspiration breath-hold technique in the treatment of inoperable non–small-cell lung cancer☆

Kenneth E. Rosenzweig; Joseph Hanley; Dennis Mah; Gig S. Mageras; Margie Hunt; Sean Toner; C Burman; C.C. Ling; Borys Mychalczak; Zvi Fuks; Steven A. Leibel

PURPOSE Conventional radiotherapeutic techniques are associated with lung toxicity that limits the treatment dose. Motion of the tumor during treatment requires the use of large safety margins that affect the feasibility of treatment. To address the control of tumor motion and decrease the volume of normal lung irradiated, we investigated the use of three-dimensional conformal radiation therapy (3D-CRT) in conjunction with the deep inspiration breath-hold (DIBH) technique. METHODS AND MATERIALS In the DIBH technique, the patient is initially maintained at quiet tidal breathing, followed by a deep inspiration, a deep expiration, a second deep inspiration, and breath-hold. At this point the patient is at approximately 100% vital capacity, and simulation, verification, and treatment take place during this phase of breath-holding. RESULTS Seven patients have received a total of 164 treatment sessions and have tolerated the technique well. The estimated normal tissue complication probabilities decreased in all patients at their prescribed dose when compared to free breathing. The dose to which patients could be treated with DIBH increased on average from 69.4 Gy to 87.9 Gy, without increasing the risk of toxicity. CONCLUSIONS The DIBH technique provides an advantage to conventional free-breathing treatment by decreasing lung density, reducing normal safety margins, and enabling more accurate treatment. These improvements contribute to the effective exclusion of normal lung tissue from the high-dose region and permit the use of higher treatment doses without increased risks of toxicity.


Journal of Clinical Oncology | 2009

Multicenter Phase II Trial of Neoadjuvant Pemetrexed Plus Cisplatin Followed by Extrapleural Pneumonectomy and Radiation for Malignant Pleural Mesothelioma

Lee M. Krug; Harvey I. Pass; Valerie W. Rusch; Hedy L. Kindler; David J. Sugarbaker; Kenneth E. Rosenzweig; Raja M. Flores; Joseph S. Friedberg; Katherine M. Pisters; Matthew J. Monberg; Coleman K. Obasaju; Nicholas J. Vogelzang

PURPOSE Neoadjuvant pemetrexed plus cisplatin was administered, followed by extrapleural pneumonectomy (EPP) and hemithoracic radiation (RT), to assess the feasibility and efficacy of trimodality therapy in stage I to III malignant pleural mesothelioma. PATIENTS AND METHODS Requirements included stage T1-3 N0-2 disease, no prior surgical resection, adequate organ function (including predicted postoperative forced expiratory volume in 1 second > or = 35%), and performance status 0 to 1. Patients received pemetrexed 500 mg/m(2) plus cisplatin 75 mg/m(2) for four cycles. Patients without disease progression underwent EPP followed by RT (54 Gy). The primary end point was pathologic complete response (pCR) rate. RESULTS Seventy-seven patients received chemotherapy. All four cycles were administered to 83% of patients. The radiologic response rate was 32.5% (95% CI, 22.2 to 44.1). Fifty-seven patients proceeded to EPP, which was completed in 54 patients. Three pCRs were observed (5% of EPP). Forty of 44 patients completed irradiation. Median survival in the overall population was 16.8 months (95% CI, 13.6 to 23.2 months; censorship, 33.8%). Patients completing all therapy had a median survival of 29.1 months and a 2-year survival rate of 61.2%. Radiologic response of complete or partial response was associated with a median survival of 26.0 months compared with 13.9 months for patients with stable disease or progressive disease (P = .05). CONCLUSION This multicenter trial showed that trimodality therapy with neoadjuvant pemetrexed plus cisplatin is feasible with a reasonable long-term survival rate, particularly for patients who completed all therapy. Radiologic response to chemotherapy, but not sex, histology, disease stage, or nodal status, was associated with improved survival.


International Journal of Radiation Oncology Biology Physics | 2000

Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer

Dennis Mah; Joseph Hanley; Kenneth E. Rosenzweig; Ellen Yorke; Louise E. Braban; C. Clifton Ling; Stephen A. Leibel; G Mageras

PURPOSE The goal of this paper is to describe our initial experience with the deep inspiration breath-hold (DIBH) technique in conformal treatment of non-small-cell lung cancer with particular emphasis on the technical aspects required for implementation. METHODS AND MATERIALS In the DIBH technique, the patient is verbally coached through a modified slow vital capacity maneuver and brought to a reproducible deep inspiration breath-hold level. The goal is to immobilize the tumor and to expand normal lung out of the high-dose region. A physicist or therapist monitors and records patient breathing during simulation, verification, and treatment using a spirometer with a custom computer interface. Examination of internal anatomy during fluoroscopy over multiple breath holds establishes the reproducibility of the DIBH maneuver for each patient. A reference free-breathing CT scan and DIBH planning scan are obtained. To provide an estimate of tumor motion during normal tidal breathing, additional scan sets are obtained at end inspiration and end expiration. These are also used to set the spirometer action levels for treatment. Patient lung inflation is independently verified over the course of treatment by comparing the distance from the isocenter to the diaphragm measured from the DIBH digitally reconstructed radiographs to the distance measured on the portal films. Patient breathing traces obtained during treatment were examined retrospectively to assess the reproducibility of the technique. RESULTS Data from the first 7 patients, encompassing over 250 treatments, were analyzed. The inferred displacement of the centroid of gross tumor volume from its position in the planning scan, as calculated from the spirometer records in over 350 breath holds was 0.02 +/- 0.14 cm (mean and standard deviation). These data are consistent with the displacements of the diaphragm (-0.1 +/- 0.4 cm; range, from -1.2 to 1.1 cm) relative to the isocenter, as measured on the (92) portal films. The latter measurements include the patient setup error. The patient averaged displacement of the tumor during free breathing, determined from the tumor displacement between end inspiration and end expiration, was 0.8 +/- 0.5 cm in both the superior-inferior and anterior-posterior directions and 0.1 cm (+/- 0.1 cm) medial-laterally. CONCLUSION Treatment of patients with the DIBH technique is feasible in a clinical setting. With this technique, consistent lung inflation levels are achieved in patients, as judged by both spirometry and verification films. Breathing-induced tumor motion is significantly reduced using DIBH compared to free breathing, enabling better target coverage.


International Journal of Radiation Oncology Biology Physics | 2001

Treatment planning and delivery of intensity-modulated radiation therapy for primary nasopharynx cancer

Margie Hunt; Michael J. Zelefsky; Suzanne L. Wolden; Chen-Shou Chui; Thomas LoSasso; Kenneth E. Rosenzweig; Lanceford M. Chong; Spiridon V. Spirou; Lisa Fromme; Moira Lumley; Howard A Amols; C.C. Ling; Steven A. Leibel

PURPOSE To implement intensity-modulated radiation therapy (IMRT) for primary nasopharynx cancer and to compare this technique with conventional treatment methods. METHODS AND MATERIALS Between May 1998 and June 2000, 23 patients with primary nasopharynx cancer were treated with IMRT delivered with dynamic multileaf collimation. Treatments were designed using an inverse planning algorithm, which accepts dose and dose-volume constraints for targets and normal structures. The IMRT plan was compared with a traditional plan consisting of phased lateral fields and a three-dimensional (3D) plan consisting of a combination of lateral fields and a 3D conformal plan. RESULTS Mean planning target volume (PTV) dose increased from 67.9 Gy with the traditional plan, to 74.6 Gy and 77.3 Gy with the 3D and IMRT plans, respectively. PTV coverage improved in the parapharyngeal region, the skull base, and the medial aspects of the nodal volumes using IMRT and doses to all normal structures decreased compared to the other treatment approaches. Average maximum cord dose decreased from 49 Gy with the traditional plan, to 44 Gy with the 3D plan and 34.5 Gy with IMRT. With the IMRT plan, the volume of mandible and temporal lobes receiving more than 60 Gy decreased by 10-15% compared to the traditional and 3D plans. The mean parotid gland dose decreased with IMRT, although it was not low enough to preserve salivary function. CONCLUSION Lower normal tissue doses and improved target coverage, primarily in the retropharynx, skull base, and nodal regions, were achieved using IMRT. IMRT could potentially improve locoregional control and toxicity at current dose levels or facilitate dose escalation to further enhance locoregional control.


International Journal of Radiation Oncology Biology Physics | 2002

Dose-volume factors contributing to the incidence of radiation pneumonitis in non-small-cell lung cancer patients treated with three-dimensional conformal radiation therapy

Ellen Yorke; Andrew Jackson; Kenneth E. Rosenzweig; Scott Merrick; Dorota Gabrys; Ennapadam Venkatraman; C Burman; Steven A. Leibel; C. Clifton Ling

PURPOSE To analyze acute lung toxicity data of non-small-cell lung cancer patients treated with three-dimensional conformal radiation therapy in terms of dosimetric variables, location of dose within subvolumes of the lungs, and models of normal-tissue complication probability (NTCP). METHODS AND MATERIALS Dose distributions of 49 non-small-cell lung cancer patients treated in a dose escalation protocol between 1992 and 1999 were analyzed (dose range: 57.6-81 Gy). Nine patients had RTOG Grade 3 or higher acute lung toxicity. Correlation with dosimetric and physical variables, as well as Lyman and parallel NTCP models, was assessed. Lungs were evaluated as a single structure, as superior and inferior halves (to assess significance of dose to upper and lower lungs), and as ipsilateral and contralateral lungs. RESULTS For the whole lung, Grade 3 or higher pneumonitis was significantly correlated (p <or= 0.05) with mean dose and Lyman and parallel model indices (d(eff) and f(dam)). It was significantly correlated with these indices and with V20 for the ipsilateral lung and with mean dose and d(eff) for the inferior half of the lungs. Dosimetric and NTCP model quantities for the superior half of the lungs and contralateral lung were not significantly correlated (p > 0.5 for superior lung indices, and >0.1 for contralateral lung indices studied). CONCLUSIONS For these patients, commonly used dosimetric and NTCP models are significantly correlated with >or= Grade 3 pneumonitis. Equivalently strong correlations are found in the lower portion of the lungs and the ipsilateral lung, but not in the upper portion or contralateral lung.


International Journal of Radiation Oncology Biology Physics | 2002

Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging

Eric C. Ford; G Mageras; Ellen Yorke; Kenneth E. Rosenzweig; Raquel Wagman; C.C. Ling

PURPOSE To evaluate the effectiveness of a commercial system(1) in reducing respiration-induced treatment uncertainty by gating the radiation delivery. METHODS AND MATERIALS The gating system considered here measures respiration from the position of a reflective marker on the patients chest. Respiration-triggered planning CT scans were obtained for 8 patients (4 lung, 4 liver) at the intended phase of respiration (6 at end expiration and 2 at end inspiration). In addition, fluoroscopic movies were recorded simultaneously with the respiratory waveform. During the treatment sessions, gated localization films were used to measure the position of the diaphragm relative to the vertebral bodies, which was compared to the reference digitally reconstructed radiograph derived from the respiration-triggered planning CT. Variability was quantified by the standard deviation about the mean position. We also assessed the interfraction variability of soft tissue structures during gated treatment in 2 patients using an amorphous silicon electronic portal imaging device. RESULTS The gated localization films revealed an interfraction patient-averaged diaphragm variability of 2.8 +/- 1.0 mm (error bars indicate standard deviation in the patient population). The fluoroscopic data yielded a patient-averaged intrafraction diaphragm variability of 2.6 +/- 1.7 mm. With no gating, this intrafraction excursion became 6.9 +/- 2.1 mm. In gated localization films, the patient-averaged mean displacement of the diaphragm from the planning position was 0.0 +/- 3.9 mm. However, in 4 of the 8 patients, the mean (over localization films) displacement was >4 mm, indicating a systematic displacement in treatment position from the planned one. The position of soft tissue features observed in portal images during gated treatments over several fractions showed a mean variability between 2.6 and 5.7 mm. The intrafraction variability, however, was between 0.6 and 1.4 mm, indicating that most of the variability was due to patient setup errors rather than to respiratory motion. CONCLUSIONS The gating system evaluated here reduces the intra- and interfraction variability of anatomy due to respiratory motion. However, systematic displacements were observed in some cases between the location of an anatomic feature at simulation and its location during treatment. Frequent monitoring is advisable with film or portal imaging.


Medical Physics | 2002

Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer

Sadek A. Nehmeh; Yusuf E. Erdi; C.C. Ling; Kenneth E. Rosenzweig; Olivia Squire; Louise E. Braban; Eric C. Ford; K. Sidhu; G Mageras; S. M. Larson; John L. Humm

Positron emission tomography (PET) has shown an increase in both sensitivity and specificity over computed tomography (CT) in lung cancer. However, motion artifacts in the 18F fluorodioxydoglucose (FDG) PET images caused by respiration persists to be an important factor in degrading PET image quality and quantification. Motion artifacts lead to two major effects: First, it affects the accuracy of quantitation, producing a reduction of the measured standard uptake value (SUV). Second, the apparent lesion volume is overestimated. Both impact upon the usage of PET images for radiation treatment planning. The first affects the visibility, or contrast, of the lesion. The second results in an increase in the planning target volume, and consequently a greater radiation dose to the normal tissues. One way to compensate for this effect is by applying a multiple-frame capture technique. The PET data are then acquired in synchronization with the respiratory motion. Reduction in smearing due to gating was investigated in both phantoms and patient studies. Phantom studies showed a dependence of the reduction in smearing on the lesion size, the motion amplitude, and the number of bins used for data acquisition. These studies also showed an improvement in the target-to-background ratio, and a more accurate measurement of the SUV. When applied to one patient, respiratory gating showed a 28% reduction in the total lesion volume, and a 56.5% increase in the SUV. This study was conducted as a proof of principle that a gating technique can effectively reduce motion artifacts in PET image acquisition.


Journal of Applied Clinical Medical Physics | 2001

Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system

G Mageras; Ellen Yorke; Kenneth E. Rosenzweig; Louise E. Braban; Eric Keatley; Eric C. Ford; Steven A. Leibel; C. Clifton Ling

We report on initial patient studies to evaluate the performance of a commercial respiratory gating radiotherapy system. The system uses a breathing monitor, consisting of a video camera and passive infrared reflective markers placed on the patients thorax, to synchronize radiation from a linear accelerator with the patients breathing cycle. Six patients receiving treatment for lung cancer participated in a study of system characteristics during treatment simulation with fluoroscopy. Breathing synchronized fluoroscopy was performed initially without instruction, followed by fluoroscopy with recorded verbal instruction (i.e., when to inhale and exhale) with the tempo matched to the patients normal breathing period. Patients tended to inhale more consistently when given instruction, as assessed by an external marker movement. This resulted in smaller variation in expiration and inspiration marker positions relative to total excursion, thereby permitting more precise gating tolerances at those parts of the breathing cycle. Breathing instruction also reduced the fraction of session times having irregular breathing as measured by the system software, thereby potentially increasing the accelerator duty factor and decreasing treatment times. Fluoroscopy studies showed external monitor movement to correlate well with that of the diaphragm in four patients, whereas time delays of up to 0.7 s in diaphragm movement were observed in two patients with impaired lung function. From fluoroscopic observations, average patient diaphragm excursion was reduced from 1.4 cm (range 0.7–2.1 cm) without gating and without breathing instruction, to 0.3 cm (range 0.2–0.5 cm) with instruction and with gating tolerances set for treatment at expiration for 25% of the breathing cycle. Patients expressed no difficulty with following instruction for the duration of a session. We conclude that the external monitor accurately predicts internal respiratory motion in most cases; however, it may be important to check with fluoroscopy for possible time delays in patients with impaired lung function. Furthermore, we observe that verbal instruction can improve breathing regularity, thus improving the performance of gated treatments with this system. PACS number(s): 87.53.–j, 87.62.+n


International Journal of Radiation Oncology Biology Physics | 2000

Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET)

Yusuf E. Erdi; Ellen Yorke; Alev K. Erdi; Louise E. Braban; Yu-Chi Hu; Homer A. Macapinlac; John L. Humm; S. M. Larson; Kenneth E. Rosenzweig

PURPOSE Many patients with non-small cell lung cancer (NSCLC) receive external beam radiation therapy as part of their treatment. Three-dimensional conformal radiation therapy (3DCRT) commonly uses computed tomography (CT) to accurately delineate the target lesion and normal tissues. Clinical studies, however, indicate that positron emission tomography (PET) has higher sensitivity than CT in detecting and staging of mediastinal metastases. Imaging with fluoro-2-deoxyglucose (FDG) PET in conjunction with CT, therefore, can improve the accuracy of lesion definition. In this pilot study, we investigated the potential benefits of incorporating PET data into the conventional treatment planning of NSCLC. Case-by-case, we prospectively analyzed planning target volume (PTV) and lung toxicity changes for a cohort of patients. MATERIALS AND METHODS We have included 11 patients in this study. They were immobilized in the treatment position and CT simulation was performed. Following CT simulation, PET scanning was performed in the treatment position using the same body cast that was produced for CT simulation and treatment. The PTV, along with the gross target volume (GTV) and normal organs, was first delineated using the CT data set. The CT and PET transmission images were then registered in the treatment planning system using either manual or automated methods, leading to consequent registration of the CT and emission images. The PTV was then modified using the registered PET emission images. The modified PTV is seen simultaneously on both CT and PET images, allowing the physician to define the PTV utilizing the information from both data sets. Dose-volume histograms (DVHs) for lesion and normal organs were generated using both CT-based and PET+CT-based treatment plans. RESULTS For all patients, there was a change in PTV outline based on CT images versus CT/PET fused images. In seven out of 11 cases, we found an increase in PTV volume (average increase of 19%) to incorporate distant nodal disease. Among these patients, the highest normal-tissue complication probability (NTCP) for lung was 22% with combined PET/CT plan and 21% with CT-only plan. In other four patients PTV was decreased an average of 18%. The reduction of PTV in two of these patients was due to excluding atelectasis and trimming the target volume to avoid delivering higher radiation doses to nearby spinal cord or heart. CONCLUSIONS The incorporation of PET data improves definition of the primary lesion by including positive lymph nodes into the PTV. Thus, the PET data reduces the likelihood of geographic misses and hopefully improves the chance of achieving local control.

Collaboration


Dive into the Kenneth E. Rosenzweig's collaboration.

Top Co-Authors

Avatar

Ellen Yorke

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

G Mageras

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Steven A. Leibel

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Steven Lehrer

Icahn School of Medicine at Mount Sinai

View shared research outputs
Top Co-Authors

Avatar

Valerie W. Rusch

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Andrew Jackson

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Andreas Rimner

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Howard Amols

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

C.C. Ling

Memorial Sloan Kettering Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Yusuf E. Erdi

Memorial Sloan Kettering Cancer Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge