Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kenneth Stokes is active.

Publication


Featured researches published by Kenneth Stokes.


Pacing and Clinical Electrophysiology | 1992

Septal His-Purkinje ventricular pacing in canines: a new endocardial electrode approach.

Peter P. Karpawich; James Gates; Kenneth Stokes

Ventricular activation sequences and cardiac performance are influenced by pacing sites. Stimulation of or close to the specialized a trioventricular (AV) conduction system optimizes paced ventricular function compared to alternative epi‐ or endocardial muscle conduction sites. This study reports a new endocardial electrode implant approach to approximate septal His‐Purkinje ventricular pacing. Five 6‐month‐old beagles were used, A custom, platinum‐iridium, exposed helical screw electrode (Medtronic, Inc.), 4.5‐mm long, with a 17.8‐mm2 surface area, was designed with a polyurethane covered 4 filar MP35N nickle conductor lead. An 8 French sheath (USCI, Inc.) was modified as introducer to permit simultaneous implant intracardiac pressure and electrogram recordings. Following a thoracotomy, the introducer was inserted through the right atrial appendage and advanced to record optimal His‐bundle electrogram while maintaining atrial pressure along the septal tricuspid valve annulus. After electrode implant, ECG demonstrated narrow paced QRS morphology. Mean implant values showed sensed R wave 6,3 mV, slew rate 0.65 V/sec, pacing impedance 319 ohms, and threshold 0.9 V/3.3 mA at 0.5‐msec output. Necropsy showed implant above the tricuspid annulus with electrode extension into and contained within the proximal ventricular septum. This study demonstrates that an endocardial septal approach to His‐Purkinje ventricular pacing to optimize paced ventricular function is feasible with a new electrode design and precise septal implant technique. Alternative introducer designs may permit tranvenous application of this approach.


Archive | 1995

Medical electrical lead system having a torque transfer stylet

James Gates; Kenneth Stokes


Archive | 1991

Steroid eluting electrode for peripheral nerve stimulation

Philip Lee; Kenneth Stokes; Michael Colson


Archive | 1990

Steroid eluting cuff electrode for peripheral nerve stimulation

Philip Lee; Kenneth Stokes; James Gates; Gary Johnson


Archive | 1995

Medizinisches Elektrodensystem mit drehbarem Übertragungswerkzeug Medical electrode system with rotating transfer tool

James Gates; Kenneth Stokes


Archive | 1995

Implantable electrical lead for medical use

James Gates; Kenneth Stokes; ビー.ストックス ケネス; ティー.ゲイツ ジェームス


Archive | 1995

A medical electrode system with rotating transfer tool

James Gates; Kenneth Stokes


Archive | 1995

Medizinisches Elektrodensystem mit drehbarem Übertragungswerkzeug

James Gates; Kenneth Stokes


Archive | 1991

Steroid absondernde manschettenelektrode für die stimulation eines peripheren nerven. Steroid-secreting cuff electrode for stimulation of a peripheral nerve.

Philip Lee; James Gates; Kenneth Stokes; Gary Johnson


Archive | 1991

Steroid absondernde manschettenelektrode für die stimulation eines peripheren nerven. Steroid secreting cuff electrode for the stimulation of nerves peripheral.

Philip Lee; James Gates; Kenneth Stokes; Gary Johnson

Collaboration


Dive into the Kenneth Stokes's collaboration.

Top Co-Authors

Avatar

James Gates

Wayne State University

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge