Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kentaro Ohtani is active.

Publication


Featured researches published by Kentaro Ohtani.


Journal of the American College of Cardiology | 2002

Nicorandil preserves collateral circulation even at low systemic pressure in comparison with nitroglycerin: real-time myocardial contrast echocardiographic study

Akiko Iwata; Fuminobu Ishikura; Kentaro Ohtani; Juri Okazaki; Hideo Hirayama; Yasushi Kashiwagi; Sachiko Yagura; Tsutomu Toshida; Toshihiko Asanuma; Shintaro Beppu

lar damage in patrents with AMI. We investigated MCE with harmonic power Doppler (HPD), CFR and CF by using transthoracic echocardiography (TTE) in predicting func- tional recovery. Methods: We performed MCE (SONOSSSOO, Philips) by using 1:4 inter- mittent HPD with Levovist at rest and during ATP in 30 patients two weeks after anterior AMI. Peak videointenstty was measured within the risk and control regions. The peak intensity ratios of the risk area to the control area (PIR) at rest and during hyperemia were calculated. We measured CFR of the left anterior descending artery (LAD) two weeks after AMI. CF of LAD by TTE was also obtained within 24 hours after successfully recanalization


Journal of the American College of Cardiology | 2002

Real-time myocardial contrast echocardiography reveals microvessel recruitment soon after coronary occlusion

Fuminobu Ishikura; Kentaro Ohtani; Hideo Hirayama; Jyuri Okazaki; Yasushi Kashiwagi; Sachiko Yagura; Tsutomu Toshida; Akiko Iwata; Hiroyuki Kayano; Toshihiko Asanuma; Shintaro Beppu

Background and Aim: Collateral flow at the micro-vessel level is important to salvage the myocardium after acute coronary obstruction, although larger collateral vessels are observed by coronary angiography. The aim of this study was to elucidate the presence of micro-collateral channel by real-time myocardial contrast echocardiography (MCE). Methods: Short axis view of the left ventricle was recorded using real -time imaging by Sequoia 512 during infusion of 0.1 ml/min of Optison( in 17 open-chest dogs. All bubbles were destroyed by one-second exposur e of high acoustic power just after LCx occlusion. The territory of LCx was divided into 3 areas (1 Core and 2 Border zones), and the systolic wall thickening (s-WT) and contrast echo video intensity (VI) were evaluated in each zone just before and 20 seconds after LCx occlusion. It was defined that the collateral channels were good when the mean VI of core and border zones were over 20/256 gray level despite complete occlusion of LCx. The flow volume of left anterior descending coronary artery (LAD) was measured by an ultrasonic flowmeter. Results: It was determined that 7 cases had good collateral channels and other 10 cases had not. The area of risk was gradually but definitely opacified in Good group. Total VI of 3zones was significantly higher in Good group than those in Poor group (69.8+40.3 vs 12.3+6.4, p<0.001). Even in Good group, the VI of core zone was significantly lower than that of border zone (11.3+11.2 vs. 35.3+17.4, p<0.001). Mean s-WT of 3 zones was significantly higher in Good group than those in Poor group (18.8+8.6 vs. 5.5+3.3, p<0.001). S-WT correlated well with VI in all zones of all cases (r=0.916, p<0.001). The LAD flow volume increased 26.2+13.6% during LCx occlusion in Good group, while 10.5+5.3 % in Poor group. Conclusion: It is revealed that real-time MCE demonstrates the recruitment of a fine and thin collateral channel appearing soon after coronary occlusion. This finding has not been elucidated so far by other modalities. Real-time MCE can elucidate the mechanism of myocardial salvage after acute coronary obstruction in both clinical and experimental aspect.


Journal of Echocardiography | 2004

Nicorandil Preserves Coronary Collateral Circulation Compared to Nitroglycerin Even in Systemic Hypotension : A Real-Time Myocardial Contrast Echocardiographic Study

Akiko Iwata; Fuminobu Ishikura; Kentaro Ohtani; Tsutomu Toshida; Toshihiko Asanuma; Shintaro Beppu


International Congress Series | 2004

Evaluation of cardiac function and myocardial perfusion in small animals: Capability of echocardiography

Fuminobu Ishikura; Toshihiko Asanuma; Kentaro Ohtani; Shintaro Beppu


Journal of the American College of Cardiology | 2002

Which is accurate to detect the coronary stenosis using adenosine triphosphate stress test? Wall motion abnormality or replenishment curve analysis of real-time myocardial contrast echocardiography

Fuminobu Ishikura; Kentaro Ohtani; Jyuri Okazaki; Hideo Hirayama; Yasushi Kashiwagi; Sachiko Yagura; Tsutomu Toshida; Akiko Iwata; Hiroyuki Kayano; Toshihiko Asanuma; Shintaro Beppu


Journal of the American College of Cardiology | 2002

Color-coded curved anatomical M-mode analysis of contrast echocardiography: a novel technique for the diagnosis of coronary artery stenosis

Akiko Iwata; Jyuri Okazaki; Kentaro Ohtani; Hideo Hirayama; Yasushi Kashiwagi; Sachiko Yagura; Tsutomu Toshida; Toshihiko Asanuma; Fuminobu Ishikura; Shintaro Beppu


Journal of the American College of Cardiology | 2002

Three-dimensional reconstruction of coronary arteriole plexus imaging using real-time contrast echocardiography

Tsutomu Toshida; Tomoko Kutsuyama; Jyuri Okazaki; Hideo Hirayama; Kentaro Ohtani; Yasushi Kashiwagi; Sachiko Yagura; Akiko Iwata; Toshihiko Asanuma; Fuminobu Ishikura; Shintaro Beppu


Journal of the American College of Cardiology | 2002

A new method of lateral compensation of acoustic power for homogenous acoustic field: its efficacy at intravenous myocardial contrast echocardiography

Tsutomu Toshida; Kentaro Ohtani; Jyuri Okazaki; Hideo Hirayama; Yasushi Kashiwagi; Sachiko Yagura; Akiko Iwata; Toshihiko Asanuma; Fuminobu Ishikura; Tetsuya Kawagishi; Yoshitaka Mine; Shintaro Beppu


Journal of the American College of Cardiology | 2002

Myocardial opacification at intravenous myocardial contrast echocardiography depends on the depth of focus point: in vivo and in vitro study

Sachiko Yagura; Kumiko Kiyoshima; Jyuri Okazaki; Hideo Hirayama; Kentaro Ohtani; Yasushi Kashiwagi; Tsutomu Toshida; Akiko Iwata; Hiroyuki Kayano; Toshihiko Asanuma; Fuminobu Ishikura; Shintaro Beppu


Journal of the American College of Cardiology | 2002

Accuracy of intravenous myocardial contrast echocardiography for assessment of ischemic area of the heart in mice

Hideo Hirayama; Kazushi Kitamura; Kentaro Ohtani; Jyuri Okazaki; Yasushi Kashiwagi; Sachiko Yagura; Tsutomu Toshida; Akiko Iwata; Toshihiko Asanuma; Fuminobu Ishikura; Shintaro Beppu

Collaboration


Dive into the Kentaro Ohtani's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge