Keum Won Kim
Konyang University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Keum Won Kim.
Korean Journal of Radiology | 2005
Yong Sung Park; Ji Hyung Kim; Young Woo Choi; Tae Hee Lee; Cheol Mog Hwang; Young Jun Cho; Keum Won Kim
Objective To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Materials and Methods Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Results Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patient, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Conclusion Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.
Korean Journal of Radiology | 2016
Eun Hye Lee; Keum Won Kim; Young Joong Kim; Dong Rock Shin; Young Mi Park; Hyo Soon Lim; Jeong Seon Park; Hye Won Kim; You Me Kim; Hye Jung Kim; Jae Kwan Jun
Objective To analyze the diagnostic accuracy and trend in screening mammography in Korea. Materials and Methods We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), and interval cancer rate (ICR). Changes in the performance indicators were calculated as the annual percent change with 95% confidence interval (CI). Results We enrolled 128756 cases from 10 hospitals from 2005 to 2010. The recall rate was 19.1% with a downward trend over time (-12.1% per year; 95% CI, -15.9 to -8.2). The CDR was 2.69 per 1000 examinations, without a significant trend. The PPV was 1.4% with an upward trend (20.8% per year; 95% CI, 15.2 to 26.7). The sensitivity was 86.5% without a significant trend, whereas the specificity was 81.1% with an upward trend (3.3% per year; 95% CI, 2.1 to 4.5). The FPR was 18.9% with a downward trend (-12.4% per year; 95% CI, -16.2 to -8.4). The ICR was 0.5 per 1000 negative examinations without a significant trend. There were institutional variations in the diagnostic accuracy and trend except for the CDR, sensitivity, and ICR. Conclusion The sensitivity and CDR of screening mammography in the ABCS-K from 2005 to 2010 were compatible with those for Western women. The recall rate, PPV and specificity, however, were suboptimal, although they showed significant improvements over this period. A further analysis is required to explain institutional variations.
American Journal of Neuroradiology | 2017
H.C. Kim; Young Joong Kim; H.Y. Han; J.M. Yi; Jung Hwan Baek; S.Y. Park; J.Y. Seo; Keum Won Kim
BACKGROUND AND PURPOSE: Although core needle biopsy was introduced as a diagnostic alternative to fine-needle aspiration, the utility and safety of core needle biopsy for thyroid nodules in a large population has yet to be studied comprehensively. We evaluate core needle biopsy yields on a large-scale basis to investigate its potential in the preliminary diagnosis of thyroid nodules. MATERIALS AND METHODS: Between March 2005 and December 2013, 2448 initially detected thyroid nodules from 2120 consecutive patients who underwent core needle biopsy were retrospectively evaluated. Of these, 72 thyroid nodules from 63 patients were excluded due to prior fine-needle aspiration attempts. The inconclusive and conclusive result rates, diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and unnecessary surgery rate of core needle biopsy were evaluated. RESULTS: With core needle biopsy as the first-line method, the inconclusive result rate was 11.9% (283/2376) and the conclusive result rate was 88.1% (2093/2376). The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of core needle biopsy for the diagnosis of malignancy were 96.7% (1160/1200), 89.7% (347/387), 100% (813/813), 100% (347/347), and 95.3% (813/853), respectively. There were no major complications and 12 minor complications. CONCLUSIONS: We have demonstrated that first-line use of core needle biopsy may well improve diagnostic accuracy in thyroid nodules, reducing inconclusive or false-negative results and unnecessary operations. Such benefits underscore the promising role of core needle biopsy in managing thyroid nodules and optimizing related surgical decision-making.
Academic Radiology | 2018
Keum Won Kim; Cherie M. Kuzmiak; Young Joong Kim; Jae Young Seo; Hae Kyoung Jung; Mu Sik Lee
PURPOSE This study aimed to compare the diagnostic values of a combination of diffusion-weighted imaging and T2-weighted imaging (DWI-T2WI) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), and to evaluate the correlation of DWI with the histologic grade in breast cancer. MATERIALS AND METHODS This study evaluated a total of 169 breast lesions from 136 patients who underwent both DCE-MRI and DWI (b value, 1000s/mm2). Morphologic and kinetic analyses for DCE-MRI were classified according to the Breast Imaging-Reporting and Data System. For the DWI-T2WI set, a DWI-T2WI score for lesion characterization that compared signal intensity of DWI and T2WI (benign: DWI-T2WI score of 1, 2; malignant: DWI-T2WI score of 3, 4, 5) was used. The diagnostic values of DCE-MRI, DWI-T2WI set, and combined assessment of DCE and DWI-T2WI were calculated. RESULTS Of 169 breast lesions, 48 were benign and 121 were malignant (89 invasive ductal carcinoma, 24 ductal carcinoma in situ, 4 invasive lobular carcinoma, 4 mucinous carcinoma). The mean apparent diffusion coefficient (ADC) of invasive ductal carcinoma (0.92 ± 0.19 × 10-3 mm2/s) and ductal carcinoma in situ (1.11 ± 0.13 × 10-3 mm2/s) was significantly lower than the value seen in benign lesions (1.36 ± 0.22 × 10-3 mm2/s). The specificity, positive predictive value (PPV), and accuracy of DWI-T2WI set and combined assessment of DCE and DWI-T2WI (specificity, 87.5% and 91.7%; PPV, 94.3% and 96.2%; accuracy, Az = 0.876 and 0.922) were significantly higher than those of the DCE-MRI (specificity, 45.8%; PPV, 81.7%; accuracy, Az = 0.854; P < .05). A low ADC value and the presence of rim enhancement were associated with a higher histologic grade cancer (P < .05). CONCLUSION Combining DWI, T2WI, and ADC values provides increased accuracy for differentiation between benign and malignant lesions, compared with DCE-MRI. A lower ADC value was associated with a higher histologic grade cancer.
Korean Journal of Radiology | 2017
Young Joong Kim; Eun Hye Lee; Jae Kwan Jun; Dong-Rock Shin; Young Mi Park; Hye Won Kim; Youme Kim; Keum Won Kim; Hyo Soon Lim; Jeong Seon Park; Hye Jung Kim; Hye-Mi Jo
Objective To analyze participant factors that affect the diagnostic performance of screening mammography. Materials and Methods We enrolled 128756 cases from 10 hospitals between 2005 and 2010. We analyzed recall rate, cancer detection rate (CDR) per 1000 examinations, positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), and interval cancer rate (ICR) per 1000 negative examinations according to participant factors including age, breast density, and number of visit to the same institution, and adjusted for confounding variables. Results Increasing age improved recall rates (27.4% in 40s, 17.5% in 50s, 11.1% in 60s, and 8.6% in 70s), CDR (2.7, 3.2, 2.0, and 2.4), PPV (1.0, 1.8, 1.8, and 2.8%), sensitivity (81.3, 88.8, 90.3, and 94.7%), specificity (72.7, 82.7, 89.0, and 91.7%), and FPR (27.3, 17.3, 11.0, and 8.4%) (p < 0.05). Higher breast density impaired recall rates (4.0% in P1, 9.0% in P2, 28.9% in P3, and 27.8% in P4), PPV (3.3, 2.3, 1.2, and 1.3%), specificity (96.1, 91.2, 71.4, and 72.5%), and FPR (3.9, 8.9, 28.6, and 27.6%) (p < 0.001). It also increased CDR (1.3, 2.1, 3.3, and 3.6) and ICR (0.2, 0.3, 0.6, and 1.6) (p < 0.05). Successive visits to the same institution improved recall rates (20.9% for one visit, 10.7% for two visits, 7.7% for more than three visits), PPV (1.6, 2.8, and 2.7%), specificity (79.4, 89.6, and 92.5%), and FPR (20.6, 10.4, and 7.5%) (p < 0.001). Conclusion Young age and dense breasts negatively affected diagnostic performance in mammography screening, whereas successive visits to the same institution had a positive effect. Examinee education for successive visits to the same institution would improve the diagnostic performance.
Korean Journal of Anesthesiology | 2010
Sung Mee Jung; Eun Su Park; Young Su Lim; Chun Woo Yang; Keum Won Kim; Po Soon Kang
We report a case of 29-year-old, morbidly obese, diabetic primigravida who had undergone previously primary percutaneous coronary intervention with stent placement for an inferior wall myocardial infarction at 10 weeks of gestation. She remained asymptomatic with medication during the remainder of her pregnancy, but preoperative echocardiography revealed left ventricular dilation and a restrictive diastolic dysfunction with a preserved ejection fraction (46%). She developed acute pulmonary edema associated with hypertension after an elective Cesarean delivery under continuous epidural anesthesia despite the meticulous restriction of fluid.
Ultrasonography | 2018
Eun Jung Choi; Eun Hye Lee; You Me Kim; Yun-Woo Chang; Jin Hwa Lee; Young Mi Park; Keum Won Kim; Young Joong Kim; Jae Kwan Jun; Seri Hong
Purpose The purpose of this study was to record and evaluate interobserver agreement as quality control for the modified categorization of screening breast ultrasound developed by the Alliance for Breast Cancer Screening in Korea (ABCS-K) for the Mammography and Ultrasonography Study for Breast Cancer Screening Effectiveness (MUST-BE) trial. Methods Eight breast radiologists with 4-16 years of experience participated in 2 rounds of quality control testing for the MUST-BE trial. Two investigators randomly selected 125 and 100 cases of breast lesions with different ratios of malignant and benign lesions. Two versions of the modified categorization were tested. The initially modified classification was developed after the first quality control workshop, and the re-modified classification was developed after the second workshop. The re-modified categorization established by ABCS-K added size criteria and the anterior-posterior ratio compared with the initially modified classification. After a brief lecture on the modified categorization system prior to each quality control test, the eight radiologists independently categorized the lesions using the modified categorization. Interobserver agreement was measured using kappa statistics. Results The overall kappa values for the modified categorizations indicated moderate to substantial degrees of agreement (initially modified categorization and re-modified categorization: κ=0.52 and κ=0.63, respectively). The kappa values for the subcategories of category 4 were 0.37 (95% confidence interval [CI], 0.24 to 0.52) and 0.39 (95% CI, 0.31 to 0.49), respectively. The overall kappa values for both the initially modified categorization and the re-modified categorization indicated a substantial degree of agreement when dichotomizing the interpretation as benign or suspicious. Conclusion The preliminary results demonstrated acceptable interobserver agreement for the modified categorization.
Journal of Breast Cancer | 2010
Keum Won Kim; Kyu Ran Cho; Bo Kyoung Seo; Kyu Won Whang; Ok Hee Woo; Yu Whan Oh; Yun Hwan Kim; Jeoung Won Bae; Yong Sung Park; Cheol Mog Hwang; Moo Sik Lee; Kwang Ill Kim
Journal of Clinical Radiololgy | 2009
Min Sun Kim; Kyu Soon Kim; Seoung Oh Yang; Keum Won Kim
Academic Radiology | 2017
Hae Kyoung Jung; Cherie M. Kuzmiak; Keum Won Kim; Na Mi Choi; Hye Jeong Kim; Eun Lee Langman; Sora C. Yoon; Doreen Steen; Donglin Zeng; Fei Gao