Kevin Barros Azevedo
University of the Algarve
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Kevin Barros Azevedo.
Radiologia Brasileira | 2013
Raquel Constantino Pardal; António Abrantes; Luís Ribeiro; Rui Pedro Pereira Almeida; Kevin Barros Azevedo; Teresa Figueiredo; Sónia Rodrigues
Objective To compare the capacity of mammography, sonoelastography, B-mode ultrasonography and histological analysis to differentiate benign from malignant breast lesions. Materials and Methods A total of 12 histopathologically confirmed breast lesions were documented. The lesions were assessed by means of mammography, B-mode ultrasonography and sonoelastography, and histopathological analysis was utilized as a gold standard. Sensitivity and specificity were calculated. A receiver operating characteristic (ROC) curve was constructed to evaluate the diagnostic performance of the mentioned techniques. Results Sensitivity and specificity in the differentiation between benign and malignant lesions were respectively 100% and 50% for mammography, 100% and 71% for B-mode ultrasonography, and 67% and 83% for sonoelastography. The area under the ROC curve was calculated for the three imaging modalities and corresponded to 0.792 for mammography, 0.847 for B-mode ultrasonography, and 0.806 for sonoelastography. Conclusion Sonoelastography demonstrated higher specificity and lower sensitivity as compared with mammography and B-mode ultrasonography. On the other hand, B-mode ultrasonography had the largest area under the ROC curve. Sonoelastography has demonstrated to be a promising technique to detect and evaluate breast lesions, and could potentially reduce the number of unnecessary biopsies.
Radiologia Brasileira | 2016
Oksana Lesyuk; P. Sousa; Sónia Rodrigues; António Abrantes; Rui Almeida; João Pedro Pinheiro; Kevin Barros Azevedo; Luís Ribeiro
Objective To measure the scattered radiation dose at different positions simulating hip surgery. Materials and Methods We simulated fluoroscopy-assisted hip surgery in order to study the distribution of scattered radiation in the operating room. To simulate the patient, we used a anthropomorphic whole-body phantom, and we used an X-ray-specific detector to quantify the radiation. Radiographs were obtained with a mobile C-arm X-ray system in continuous scan mode, with the tube at 0º (configuration 1) or 90º (configuration 2). The operating parameters employed (voltage, current, and exposure time) were determined by a statistical analysis based on the observation of orthopedic surgical procedures involving the hip. Results For all measurements, higher exposures were observed in configuration 2. In the measurements obtained as a function of height, the maximum dose rates observed were 1.167 (± 0.023) µSv/s and 2.278 (± 0.023) µSv/s in configurations 1 and 2, respectively, corresponding to the chest level of health care professionals within the operating room. Proximal to the patient, the maximum values were recorded in the position occupied by the surgeon. Conclusion We can conclude that, in the scenario under study, health care professionals workers are exposed to low levels of radiation, and that those levels can be reduced through the use of personal protective equipment.
Radiography | 2016
Andrew England; Kevin Barros Azevedo; Paul Bezzina; Anja Henner; Jonathan P. McNulty
Desenvolvimento e Sociedade | 2017
Kevin Barros Azevedo; Carlos Alberto da Silva; António Abrantes
American Journal of Biomedical Engineering | 2013
Joana Guiomar; Luís Ribeiro; Anabela Magalhães Ribeiro; António Abrantes; João Pedro Pinheiro; Rui Almeida; Kevin Barros Azevedo
Insights into Imaging: Education and Strategies in European radiology | 2012
Patricia Lima; P. Sousa; Sónia Rodrigues; António Abrantes; Carlos Alberto da Silva; Luís Ribeiro; Rui Almeida; Kevin Barros Azevedo
Desenvolvimento e Sociedade | 2017
Carlos Alberto da Silva; Rui Pedro Pereira Almeida; António Abrantes; Dulce M. Lourenço Miranda; Tânia Filipa da Silva; Luís Ribeiro; Kevin Barros Azevedo
III Encontro de Metrologia em Saúde | 2014
António Abrantes; P. Sousa; Luís Ribeiro; Sónia Rodrigues; Carina Rebelo; Kevin Barros Azevedo; Rui Almeida; João Pedro Pinheiro
III Encontro de Metrologia em Saúde | 2014
Luís Ribeiro; Sónia Rodrigues; P. Sousa; António Abrantes; Liliana Sousa; Rui Almeida; Kevin Barros Azevedo; João Pedro Pinheiro
Insights into Imaging- ECR 2013 Book of Abstracts - B - Scientific Sessions | 2013
Tiago Filipe; Luís Ribeiro; Rui Jorge Almeida; Sónia Rodrigues; Kevin Barros Azevedo; Carlos A. Silva; António Abrantes