IEEE Transactions on Neural Systems and Rehabilitation Engineering | 2005

Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances

Matthew D. Johnson; Kevin J. Otto; Daryl R. Kipke

Reactive tissue encapsulation of chronically implanted microelectrode probes can preclude long-term recording of extracellular action potentials. We investigated an intervention strategy for functionally encapsulated microelectrode sites. This method, known as rejuvenation, involved applying a +1.5 V dc bias to an iridium site for 4 s. Previous studies have demonstrated that rejuvenation resulted in higher signal-to-noise ratios (SNRs) by decreasing noise levels, and reduced 1-kHz site impedances by decreasing the tissue interface resistances. In this study, we have investigated: 1) the duration of a single-voltage bias session and 2) the efficacy of multiple sessions. These questions were addressed through electrophysiological recordings, cyclic voltammetry, and modeling the electrode-tissue interface via an equivalent circuit model fit to impedance spectroscopy data. In the six implants studied, we found SNRs improved for 1-7 days with a peak typically occurring within 24 h of the voltage bias. Root-mean square (RMS) noise of the extracellular recordings decreased for 1-2 days, which paralleled a similar decrease in the adsorbed tissue resistance (R/sub en/) from the model. Implants whose SNR effects lasted more than a day showed stabilized reductions in the extracellular tissue resistance (R/sub ex/) and cellular membrane area (A/sub m/). Subsequent stimulus sessions were found to drop neural tissue parameters consistently to levels observed immediately after surgery. In most cases, these changes did parallel an improvement in SNR. These findings suggest that rejuvenation may be a useful intervention strategy to prolong the lifetime of chronically implanted microelectrodes.


Journal of Neural Engineering | 2005

Naïve coadaptive cortical control

Gregory J. Gage; Kip A. Ludwig; Kevin J. Otto; Edward L. Ionides; Daryl R. Kipke

The ability to control a prosthetic device directly from the neocortex has been demonstrated in rats, monkeys and humans. Here we investigate whether neural control can be accomplished in situations where (1) subjects have not received prior motor training to control the device (naive user) and (2) the neural encoding of movement parameters in the cortex is unknown to the prosthetic device (naive controller). By adopting a decoding strategy that identifies and focuses on units whose firing rate properties are best suited for control, we show that naive subjects mutually adapt to learn control of a neural prosthetic system. Six untrained Long-Evans rats, implanted with silicon micro-electrodes in the motor cortex, learned cortical control of an auditory device without prior motor characterization of the recorded neural ensemble. Single- and multi-unit activities were decoded using a Kalman filter to represent an audio cursor (90 ms tone pips ranging from 250 Hz to 16 kHz) which subjects controlled to match a given target frequency. After each trial, a novel adaptive algorithm trained the decoding filter based on correlations of the firing patterns with expected cursor movement. Each behavioral session consisted of 100 trials and began with randomized decoding weights. Within 7 +/- 1.4 (mean +/- SD) sessions, all subjects were able to significantly score above chance (P < 0.05, randomization method) in a fixed target paradigm. Training lasted 24 sessions in which both the behavioral performance and signal to noise ratio of the peri-event histograms increased significantly (P < 0.01, ANOVA). Two rats continued training on a more complex task using a bilateral, two-target control paradigm. Both subjects were able to significantly discriminate the target tones (P < 0.05, Z-test), while one subject demonstrated control above chance (P < 0.05, Z-test) after 12 sessions and continued improvement with many sessions achieving over 90% correct targets. Dynamic analysis of binary trial responses indicated that early learning for this subject occurred during session 6. This study demonstrates that subjects can learn to generate neural control signals that are well suited for use with external devices without prior experience or training.


IEEE Transactions on Biomedical Engineering | 2006

Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes

Kevin J. Otto; Matthew D. Johnson; Daryl R. Kipke

Current neuroprosthetic systems based on electrophysiological recording have an extended, yet finite working lifetime. Some posited lifetime-extension solutions involve improving device biocompatibility or suppressing host immune responses. Our objective was to test an alternative solution comprised of applying a voltage pulse to a microelectrode site, herein termed rejuvenation. Previously, investigators have reported preliminary electrophysiological results by utilizing a similar voltage pulse. In this study we sought to further explore this phenomenon via two methods: 1) electrophysiology; 2) an equivalent circuit model applied to impedance spectroscopy data. The experiments were conducted via chronically implanted silicon-substrate iridium microelectrode arrays in the rat cortex. Rejuvenation voltages resulted in increased unit recording signal-to-noise ratios (10%/spl plusmn/2%), with a maximal increase of 195% from 3.74 to 11.02. Rejuvenation also reduced the electrode site impedances at 1 kHz (67%/spl plusmn/2%). Neither the impedance nor recording properties of the electrodes changed on neighboring microelectrode sites that were not rejuvenated. In the equivalent circuit model, we found a transient increase in conductivity, the majority of which corresponded to a decrease in the tissue resistance component (44%/spl plusmn/7%). These findings suggest that rejuvenation may be an intervention strategy to prolong the functional lifetime of chronically implanted microelectrodes.


Frontiers in Neuroengineering | 2009

Poly(3,4-ethylenedioxythiophene) as a Micro-Neural Interface Material for Electrostimulation

Seth J. Wilks; Sarah Richardson-Burns; Jeffrey L. Hendricks; David C. Martin; Kevin J. Otto

Chronic microstimulation-based devices are being investigated to treat conditions such as blindness, deafness, pain, paralysis, and epilepsy. Small-area electrodes are desired to achieve high selectivity. However, a major trade-off with electrode miniaturization is an increase in impedance and charge density requirements. Thus, the development of novel materials with lower interfacial impedance and enhanced charge storage capacity is essential for the development of micro-neural interface-based neuroprostheses. In this report, we study the use of conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) as a neural interface material for microstimulation of small-area iridium electrodes on silicon-substrate arrays. Characterized by electrochemical impedance spectroscopy, electrodeposition of PEDOT results in lower interfacial impedance at physiologically relevant frequencies, with the 1u2009kHz impedance magnitude being 23.3u2009±u20090.7u2009kΩ, compared to 113.6u2009±u20093.5u2009kΩ for iridium oxide (IrOx) on 177u2009μm2 sites. Further, PEDOT exhibits enhanced charge storage capacity at 75.6u2009±u20095.4u2009mC/cm2 compared to 28.8u2009±u20090.3u2009mC/cm2 for IrOx, characterized by cyclic voltammetry (50u2009mV/s). These improvements at the electrode interface were corroborated by observation of the voltage excursions that result from constant current pulsing. The PEDOT coatings provide both a lower amplitude voltage and a more ohmic representation of the applied current compared to IrOx. During repetitive pulsing, PEDOT-coated electrodes show stable performance and little change in electrical properties, even at relatively high current densities which cause IrOx instability. These findings support the potential of PEDOT coatings as a micro-neural interface material for electrostimulation.


Hearing Research | 2005

Microstimulation in auditory cortex provides a substrate for detailed behaviors

Kevin J. Otto; Patrick Rousche; Daryl R. Kipke

Sensory cortical prostheses have potential to aid people suffering from blindness, deafness and other sensory deficits. However, research to date has shown that sensation thresholds via epicortical stimulation are surprisingly large. These thresholds result in potentially deleterious electrical currents, as well as large activation volumes. Large activation volumes putatively limit the corresponding number of independent stimulation channels in a neural prosthesis. In this study, penetrating stimulation of the auditory cortex was tested for its ability to transmit salient information to behaving rat subjects. Here, we show that subjects that were previously trained to discriminate natural stimuli immediately discriminated different microstimulation cues more accurately and with shorter response latencies than the natural stimuli. Additionally, the cortical microstimulation resulted in a generalization gradient across locations within the cortex. The results demonstrate the efficacy of using closely spaced cortical microstimulation to efficiently transmit highly salient and discriminable information to a behaving subject.


Journal of Neural Engineering | 2011

Theoretical analysis of intracortical microelectrode recordings

Scott F. Lempka; Matthew D. Johnson; Michael A. Moffitt; Kevin J. Otto; Daryl R. Kipke; Cameron C. McIntyre

Advanced fabrication techniques have now made it possible to produce microelectrode arrays for recording the electrical activity of a large number of neurons in the intact brain for both clinical and basic science applications. However, the long-term recording performance desired for these applications is hindered by a number of factors that lead to device failure or a poor signal-to-noise ratio (SNR). The goal of this study was to identify factors that can affect recording quality using theoretical analysis of intracortical microelectrode recordings of single-unit activity. Extracellular microelectrode recordings were simulated with a detailed multi-compartment cable model of a pyramidal neuron coupled to a finite-element volume conductor head model containing an implanted recording microelectrode. Recording noise sources were also incorporated into the overall modeling infrastructure. The analyses of this study would be very difficult to perform experimentally; however, our model-based approach enabled a systematic investigation of the effects of a large number of variables on recording quality. Our results demonstrate that recording amplitude and noise are relatively independent of microelectrode size, but instead are primarily affected by the selected recording bandwidth, impedance of the electrode-tissue interface and the density and firing rates of neurons surrounding the recording electrode. This study provides the theoretical groundwork that allows for the design of the microelectrode and recording electronics such that the SNR is maximized. Such advances could help enable the long-term functionality required for chronic neural recording applications.


Journal of Neural Engineering | 2013

Chronic intracortical microelectrode arrays induce non-uniform, depth-related tissue responses.

Andrew J. Woolley; Himanshi A. Desai; Kevin J. Otto

OBJECTIVEnBrain-implanted microelectrode arrays show promise as future clinical devices. However, biological responses to various designs, compositions and locations of these implants have not been fully characterized, and may impact the long-term functionality of these devices. In order to improve our understanding of the tissue conditions at the interface of chronic brain-implanted microdevices, we proposed utilizing advanced histology and microscopy techniques to image implanted devices and surrounding tissue intact within brain slices. We then proposed utilizing these methods to examine whether depth within the cerebral cortex affected tissue conditions around implants.nnnAPPROACHnHistological data was collected from rodent brain slices containing intact, intracortical microdevices four weeks after implantation surgery. Thick tissue sections containing the chronic implants were processed with fluorescent antibody labels, and imaged in an optical clearing solution using laser confocal microscopy.nnnMAIN RESULTSnTissue surrounding microdevices exhibited two major depth-related phenomena: a non-uniform microglial coating along the device length and a dense mass of cells surrounding the implant in cerebral cortical layers I and II. Detailed views of the monocyte-derived immune cells improve our understanding of the close and complex association that immune cells have with chronic brain implants, and illuminated a possible relationship between cortical depth and the intensity of a chronic monocyte response around penetrating microdevices. The dense mass of cells contained vimentin, a protein not typically expressed highly in CNS cells, evidence that non-CNS cells likely descended down the face of the penetrating devices from the pial surface.nnnSIGNIFICANCEnImage data of highly non-uniform and depth-dependent biological responses along a device provides novel insight into the complexity of the tissue response to penetrating brain-implanted microdevices. The presented work also demonstrates the value of in situ histological collection of brain implants for studying the complex tissue changes that occur, and the utility of pairing thick-tissue histology with appropriate optical clearing solutions.


Journal of Neural Engineering | 2005

Cortical microstimulation in auditory cortex of rat elicits best-frequency dependent behaviors

Kevin J. Otto; Patrick Rousche; Daryl R. Kipke

Electrical activation of the auditory cortex has been shown to elicit an auditory sensation; however, the perceptual effects of auditory cortical microstimulation delivered through penetrating microelectrodes have not been clearly elucidated. This study examines the relationship between electrical microstimulus location within the adult rat auditory cortex and the subsequent behavior induced. Four rats were trained on an auditory frequency discrimination task and their lever-pressing behavior in response to stimuli of intermediate auditory frequencies was quantified. Each trained rat was then implanted with a microwire array in the auditory cortex of the left hemisphere. Best frequencies (BFs) of each electrode in the array were determined by both local field potential and multi-unit spike-rate activity evoked by pure tone stimuli. A cross-dimensional psychophysical generalization paradigm was used to evaluate cortical microstimulation-induced behavior. Using the BFs of each electrode, the microstimulation-induced behavior was evaluated relative to the auditory-induced behavior. Microstimulation resulted in behavior that was dependent on the BFs of the electrodes used for stimulation. These results are consistent with recent reports indicating that electrophysiological recordings of neural responses to sensory stimuli may provide insight into the sensation generated by electrical stimulation of the same sensory neural tissue.


Hearing Research | 2003

Single electrode micro-stimulation of rat auditory cortex: an evaluation of behavioral performance.

Patrick Rousche; Kevin J. Otto; Mark P. Reilly; Daryl R. Kipke

A combination of electrophysiological mapping, behavioral analysis and cortical micro-stimulation was used to explore the interrelation between the auditory cortex and behavior in the adult rat. Auditory discriminations were evaluated in eight rats trained to discriminate the presence or absence of a 75 dB pure tone stimulus. A probe trial technique was used to obtain intensity generalization gradients that described response probabilities to mid-level tones between 0 and 75 dB. The same rats were then chronically implanted in the auditory cortex with a 16 or 32 channel tungsten microwire electrode array. Implanted animals were then trained to discriminate the presence of single electrode micro-stimulation of magnitude 90 microA (22.5 nC/phase). Intensity generalization gradients were created to obtain the response probabilities to mid-level current magnitudes ranging from 0 to 90 microA on 36 different electrodes in six of the eight rats. The 50% point (the current level resulting in 50% detections) varied from 16.7 to 69.2 microA, with an overall mean of 42.4 (+/-8.1) microA across all single electrodes. Cortical micro-stimulation induced sensory-evoked behavior with similar characteristics as normal auditory stimuli. The results highlight the importance of the auditory cortex in a discrimination task and suggest that micro-stimulation of the auditory cortex might be an effective means for a graded information transfer of auditory information directly to the brain as part of a cortical auditory prosthesis.


Journal of Neuroscience Methods | 2011

In situ characterization of the brain–microdevice interface using Device Capture Histology

Andrew J. Woolley; Himanshi A. Desai; Mitchell A. Steckbeck; Neil K. Patel; Kevin J. Otto

Accurate assessment of brain-implantable microdevice bio-integration remains a formidable challenge. Prevailing histological methods require device extraction prior to tissue processing, often disrupting and removing the tissue of interest which had been surrounding the device. The Device-Capture Histology method, presented here, overcomes many limitations of the conventional Device-Explant Histology method, by collecting the device and surrounding tissue intact for subsequent labeling. With the implant remaining in situ, accurate and precise imaging of the morphologically preserved tissue at the brain/microdevice interface can then be collected and quantified. First, this article presents the Device-Capture Histology method for obtaining and processing the intact, undisturbed microdevice-tissue interface, and imaging using fluorescent labeling and confocal microscopy. Second, this article gives examples of how to quantify features found in the captured peridevice tissue. We also share histological data capturing (1) the impact of microdevice implantation on tissue, (2) the effects of an experimental anti-inflammatory coating, (3) a dense grouping of cell nuclei encapsulating a long-term implant, and (4) atypical oligodendrocyte organization neighboring a long term implant. Data sets collected using the Device-Capture Histology method are presented to demonstrate the significant advantages of processing the intact microdevice-tissue interface, and to underscore the utility of the method in understanding the effects of the brain-implantable microdevices on nearby tissue.

Collaboration


Dive into the Kevin J. Otto's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Justin C. Williams

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge