Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kevin M. Kiesler is active.

Publication


Featured researches published by Kevin M. Kiesler.


Forensic Science International-genetics | 2016

Sequence variation of 22 autosomal STR loci detected by next generation sequencing

Katherine Butler Gettings; Kevin M. Kiesler; Seth A. Faith; Elizabeth Montano; Christine H. Baker; Brian A. Young; Richard A. Guerrieri; Peter M. Vallone

Sequencing short tandem repeat (STR) loci allows for determination of repeat motif variations within the STR (or entire PCR amplicon) which cannot be ascertained by size-based PCR fragment analysis. Sanger sequencing has been used in research laboratories to further characterize STR loci, but is impractical for routine forensic use due to the laborious nature of the procedure in general and additional steps required to separate heterozygous alleles. Recent advances in library preparation methods enable high-throughput next generation sequencing (NGS) and technological improvements in sequencing chemistries now offer sufficient read lengths to encompass STR alleles. Herein, we present sequencing results from 183 DNA samples, including African American, Caucasian, and Hispanic individuals, at 22 autosomal forensic STR loci using an assay designed for NGS. The resulting dataset has been used to perform population genetic analyses of allelic diversity by length compared to sequence, and exemplifies which loci are likely to achieve the greatest gains in discrimination via sequencing. Within this data set, six loci demonstrate greater than double the number of alleles obtained by sequence compared to the number of alleles obtained by length: D12S391, D2S1338, D21S11, D8S1179, vWA, and D3S1358. As expected, repeat region sequences which had not previously been reported in forensic literature were identified.


Forensic Science International-genetics | 2015

Performance of a next generation sequencing SNP assay on degraded DNA

Katherine Butler Gettings; Kevin M. Kiesler; Peter M. Vallone

Forensic DNA casework samples are often of insufficient quantity or quality to generate full profiles by conventional DNA typing methods. Polymerase chain reaction (PCR) amplification of short tandem repeat (STR) loci is inherently limited in samples containing degraded DNA, as the cumulative size of repeat regions, primer binding regions, and flanking sequence is necessarily larger than the PCR template. Additionally, traditional capillary electrophoresis (CE) assay design further inherently limits shortening amplicons because the markers must be separated by size. Non-traditional markers, such as single nucleotide polymorphisms (SNPs) and insertion deletion polymorphisms (InDels), may yield more information from challenging samples due to their smaller amplicon size. In this study, the performance of a next generation sequencing (NGS) SNP assay and CE-based STR, mini-STR, and InDel assays was evaluated with a series of fragmented, size-selected samples. Information obtained from the NGS SNP assay exhibited higher overall inverse random match probability (1/RMP) values compared to the CE-based typing assays, with particular benefit for fragment sizes ≤ 150 base pairs (bp). The InDel, mini-STR, and NGS SNP assays all had similar percentages of loci with reportable alleles at this level of degradation; however, the relatively fewer number of loci in the InDel and mini-STR assays results in the NGS SNP assay having at least nine orders of magnitude higher 1/RMP values. In addition, the NGS SNP assay and three CE-based assays (two STR and one InDel assay) were tested using a dilution series consisting of 0.5 ng, 0.1 ng, and 0.05 ng non-degraded DNA. All tested assays showed similar percentages of loci with reportable alleles at these levels of input DNA; however, due to the larger number of loci, the NGS SNP assay and the larger of the two tested CE-based STR assays both resulted in considerably higher 1/RMP values than the other assays. These results indicate the potential advantage of NGS SNP assays for forensic analysis of degraded DNA samples.


Forensic Science International-genetics | 2014

Collaborative EDNAP exercise on the IrisPlex system for DNA-based prediction of human eye colour

Lakshmi Chaitanya; Susan Walsh; Jeppe Dyrberg Andersen; Ricky Ansell; Kaye N. Ballantyne; David Ballard; Regine Banemann; Christiane Maria Bauer; Ana Margarida Bento; Francesca Brisighelli; Tomas Capal; Lindy Clarisse; T.E. Gross; Cordula Haas; P. Hoff-Olsen; Clémence Hollard; Christine Keyser; Kevin M. Kiesler; Priscila Kohler; Tomasz Kupiec; Adrian Linacre; Anglika Minawi; Niels Morling; Helena Nilsson; L. Norén; Renée Ottens; Jukka U. Palo; Walther Parson; Vincenzo Lorenzo Pascali; C. Phillips

The IrisPlex system is a DNA-based test system for the prediction of human eye colour from biological samples and consists of a single forensically validated multiplex genotyping assay together with a statistical prediction model that is based on genotypes and phenotypes from thousands of individuals. IrisPlex predicts blue and brown human eye colour with, on average, >94% precision accuracy using six of the currently most eye colour informative single nucleotide polymorphisms (HERC2 rs12913832, OCA2 rs1800407, SLC24A4 rs12896399, SLC45A2 (MATP) rs16891982, TYR rs1393350, and IRF4 rs12203592) according to a previous study, while the accuracy in predicting non-blue and non-brown eye colours is considerably lower. In an effort to vigorously assess the IrisPlex system at the international level, testing was performed by 21 laboratories in the context of a collaborative exercise divided into three tasks and organised by the European DNA Profiling (EDNAP) Group of the International Society of Forensic Genetics (ISFG). Task 1 involved the assessment of 10 blood and saliva samples provided on FTA cards by the organising laboratory together with eye colour phenotypes; 99.4% of the genotypes were correctly reported and 99% of the eye colour phenotypes were correctly predicted. Task 2 involved the assessment of 5 DNA samples extracted by the host laboratory from simulated casework samples, artificially degraded, and provided to the participants in varying DNA concentrations. For this task, 98.7% of the genotypes were correctly determined and 96.2% of eye colour phenotypes were correctly inferred. For Tasks 1 and 2 together, 99.2% (1875) of the 1890 genotypes were correctly generated and of the 15 (0.8%) incorrect genotype calls, only 2 (0.1%) resulted in incorrect eye colour phenotypes. The voluntary Task 3 involved participants choosing their own test subjects for IrisPlex genotyping and eye colour phenotype inference, while eye photographs were provided to the organising laboratory and judged; 96% of the eye colour phenotypes were inferred correctly across 100 samples and 19 laboratories. The high success rates in genotyping and eye colour phenotyping clearly demonstrate the reproducibility and the robustness of the IrisPlex assay as well as the accuracy of the IrisPlex model to predict blue and brown eye colour from DNA. Additionally, this study demonstrates the ease with which the IrisPlex system is implementable and applicable across forensic laboratories around the world with varying pre-existing experiences.


Forensic Science International-genetics | 2017

Characterization of NIST human mitochondrial DNA SRM-2392 and SRM-2392-I standard reference materials by next generation sequencing

Sarah Riman; Kevin M. Kiesler; Lisa A. Borsuk; Peter M. Vallone

Standard Reference Materials SRM 2392 and 2392-I are intended to provide quality control when amplifying and sequencing human mitochondrial genome sequences. The National Institute of Standards and Technology (NIST) offers these SRMs to laboratories performing DNA-based forensic human identification, molecular diagnosis of mitochondrial diseases, mutation detection, evolutionary anthropology, and genetic genealogy. The entire mtGenome (∼16569bp) of SRM 2392 and 2392-I have previously been characterized at NIST by Sanger sequencing. Herein, we used the sensitivity, specificity, and accuracy offered by next generation sequencing (NGS) to: (1) re-sequence the certified values of the SRM 2392 and 2392-I; (2) confirm Sanger data with a high coverage new sequencing technology; (3) detect lower level heteroplasmies (<20%); and thus (4) support mitochondrial sequencing communities in the adoption of NGS methods. To obtain a consensus sequence for the SRMs as well as identify and control any bias, sequencing was performed using two NGS platforms and data was analyzed using different bioinformatics pipelines. Our results confirm five low level heteroplasmy sites that were not previously observed with Sanger sequencing: three sites in the GM09947A template in SRM 2392 and two sites in the HL-60 template in SRM 2392-I.


Forensic Science International-genetics | 2014

Comparison of base composition analysis and Sanger sequencing of mitochondrial DNA for four U.S. population groups

Kevin M. Kiesler; Michael D. Coble; Thomas A. Hall; Peter M. Vallone

A set of 711 samples from four U.S. population groups was analyzed using a novel mass spectrometry based method for mitochondrial DNA (mtDNA) base composition profiling. Comparison of the mass spectrometry results with Sanger sequencing derived data yielded a concordance rate of 99.97%. Length heteroplasmy was identified in 46% of samples and point heteroplasmy was observed in 6.6% of samples in the combined mass spectral and Sanger data set. Using discrimination capacity as a metric, Sanger sequencing of the full control region had the highest discriminatory power, followed by the mass spectrometry base composition method, which was more discriminating than Sanger sequencing of just the hypervariable regions. This trend is in agreement with the number of nucleotides covered by each of the three assays.


Croatian Medical Journal | 2013

Allele frequencies for 40 autosomal SNP loci typed for US population samples using electrospray ionization mass spectrometry

Kevin M. Kiesler; Peter M. Vallone

Aim To type a set of 194 US African American, Caucasian, and Hispanic samples (self-declared ancestry) for 40 autosomal single nucleotide polymorphism (SNP) markers intended for human identification purposes. Methods Genotyping was performed on an automated commercial electrospray ionization time-of-flight mass spectrometer, the PLEX-ID. The 40 SNP markers were amplified in eight unique 5plex PCRs, desalted, and resolved based on amplicon mass. For each of the three US sample groups statistical analyses were performed on the resulting genotypes. Results The assay was found to be robust and capable of genotyping the 40 SNP markers consuming approximately 4 nanograms of template per sample. The combined random match probabilities for the 40 SNP assay ranged from 10−16 to 10−21. Conclusion The multiplex PLEX-ID SNP-40 assay is the first fully automated genotyping method capable of typing a panel of 40 forensically relevant autosomal SNP markers on a mass spectrometry platform. The data produced provided the first allele frequencies estimates for these 40 SNPs in a National Institute of Standards and Technology US population sample set. No population bias was detected although one locus deviated from its expected level of heterozygosity.


Electrophoresis | 2018

Sequence-based US population data for the SE33 locus

Lisa A. Borsuk; Katherine Butler Gettings; Carolyn R. Steffen; Kevin M. Kiesler; Peter M. Vallone

A set of 1036 U.S. Population Samples were sequenced using the Illumina ForenSeq DNA Signature Prep Kit. This sample set has been highly characterized using a variety of marker systems for human identification. The FASTQ files obtained from a ForenSeq DNA Signature Prep Kit experiment include several STR loci that are not reported in the associated software. These include SE33, DXS8377, DXS10148, DYS456, and DYS461. The sequence variation within the autosomal STR marker SE33 was evaluated using a customized bioinformatic approach to identify and characterize the locus in the 1036 data set. The analysis identified 53 unique alleles by length and 264 by sequence. An additional 10 alleles were detected when selected extended flanking regions were examined to resolve discordances. Allele frequencies and SE33 sequence motif patterns are reported for the 1036 data set. The comparison of numerical allele calls derived from sequence data to the allele calls obtained from commercial capillary electrophoresis‐based STR typing kits resulted in 100% concordance, after manual data review and confirmation sequencing of three flanking region deletions. The analysis of this data set involved significant manual sequence curation and information support from length‐based genotypes to ensure high confidence in the sequence‐based allele calls. The challenges of interpreting the sequence data for SE33 consisted of high sequence noise, allele‐size dependent variance in coverage, and heterozygote imbalance. As allele length increased, sequence depth of coverage and quality decreased at the terminal end. Accordingly, heterozygous genotype imbalance increased in proportion to increased distance between alleles.


Forensic Science International-genetics | 2018

Sequence-based U.S. population data for 27 autosomal STR loci

Katherine Butler Gettings; Lisa A. Borsuk; Carolyn R. Steffen; Kevin M. Kiesler; Peter M. Vallone

This manuscript reports Short Tandem Repeat (STR) sequence-based allele frequencies for 1036 samples across 27 autosomal STR loci: D1S1656, TPOX, D2S441, D2S1338, D3S1358, D4S2408, FGA, D5S818, CSF1PO, D6S1043, D7S820, D8S1179, D9S1122, D10S1248, TH01, vWA, D12S391, D13S317, Penta E, D16S539, D17S1301, D18S51, D19S433, D20S482, D21S11, Penta D, and D22S1045. Sequence data were analyzed by two bioinformatic pipelines and all samples have been evaluated for concordance with alleles derived from CE-based analysis at all loci. Each reported sequence includes high-quality flanking sequence and is properly formatted according to the most recent guidance of the International Society for Forensic Genetics. In addition, GenBank accession numbers are reported for each sequence, and associated records are available in the STRSeq BioProject (https://www.ncbi.nlm.nih.gov/bioproject/380127). The D3S1358 locus demonstrates the greatest average increase in heterozygosity across populations (approximately 10 percentage points). Loci demonstrating average increase in heterozygosity from 10 to 5 percentage points include (in descending order) D9S1122, D13S317, D8S1179, D21S11, D5S818, D12S391, and D2S441. The remaining 19 loci each demonstrate less than 5 percentage point increase in average heterozygosity. Discussion includes the utility of this data in understanding traditional CE results, such as informing stutter models and understanding migration challenges, and considerations for population sampling strategies in light of the marked increase in rare alleles for several of the sequence-based STR loci. This NIST 1036 data set is expected to support the implementation of STR sequencing forensic casework by providing high-confidence sequence-based allele frequencies for the same sample set which are already the basis for population statistics in many U.S. forensic laboratories.


Forensic Science International: Genetics Supplement Series | 2015

The next dimension in STR sequencing: Polymorphisms in flanking regions and their allelic associations

Katherine Butler Gettings; Rachel A. Aponte; Kevin M. Kiesler; Peter M. Vallone


Forensic Science International: Genetics Supplement Series | 2017

Initial assessment of the Precision ID Globalfiler Mixture ID panel on the Ion Torrent S5XL DNA sequencer and Converge v2.0 software

Kevin M. Kiesler; Carolyn R. Steffen; Michael D. Coble; Peter M. Vallone

Collaboration


Dive into the Kevin M. Kiesler's collaboration.

Top Co-Authors

Avatar

Peter M. Vallone

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Katherine Butler Gettings

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Carolyn R. Steffen

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Lisa A. Borsuk

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Michael D. Coble

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Blaza Toman

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Brian A. Young

Battelle Memorial Institute

View shared research outputs
Top Co-Authors

Avatar

Christine H. Baker

Battelle Memorial Institute

View shared research outputs
Top Co-Authors

Avatar

Elizabeth Montano

Battelle Memorial Institute

View shared research outputs
Top Co-Authors

Avatar

Megan H Cleveland

National Institute of Standards and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge