Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Khaldun M. Al Azzam is active.

Publication


Featured researches published by Khaldun M. Al Azzam.


Analytica Chimica Acta | 2010

Enantioselective analysis of ofloxacin and ornidazole in pharmaceutical formulations by capillary electrophoresis using single chiral selector and computational calculation of their inclusion complexes

Khaldun M. Al Azzam; Bahruddin Saad; Rohana Adnan; Hassan Y. Aboul-Enein

A capillary electrophoretic method for the separation of the enantiomers of both ofloxacin and ornidazole is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixtures was achieved in less than 16 min with resolution factors Rs=5.45 and 6.28 for ofloxacin and ornidazole enantiomers, respectively. Separation was conducted using a bare fused-silica capillary and a background electrolyte (BGE) of 50 mM H(3)PO(4)-1 M tris solution; pH 1.85; containing 30 mg mL(-1) of sulfated-beta-cyclodextrin (S-beta-CD). The separation was carried out in reversed polarity mode at 25 degrees C, 18 kV, detection wavelength at 230 nm and using hydrodynamic injection for 15 s. Acceptable validation criteria for selectivity, linearity, precision, and accuracy were studied. The limits of detection (LOD) and limits of quantitation (LOQ) of the enantiomers (ofloxacin enantiomer 1 (OF-E1), ofloxacin enantiomer 2 (OF-E2), ornidazole enantiomer 1 (OR-E1) and ornidazole enantiomer 2 (OR-E2)) were (0.52, 0.46, 0.54, 0.89) and (1.59, 1.40, 3.07, 2.70) microg mL(-1), respectively. The proposed method was successfully applied to the assay of enantiomers of both ofloxacin and ornidazole in pharmaceutical formulations. The computational calculations for the enantiomeric inclusion complexes rationalized the reasons for the different migration times between the ofloxacin and ornidazole enantiomers.


Journal of Chromatography A | 2010

Hollow fiber liquid-phase microextraction for the determination of trace amounts of rosiglitazone (anti-diabetic drug) in biological fluids using capillary electrophoresis and high performance liquid chromatographic methods

Khaldun M. Al Azzam; Ahmad Makahleah; Bahruddin Saad; Sharif Mahsufi Mansor

A three-phase hollow fiber liquid-phase microextraction (HF-LPME) coupled either with capillary electrophoresis (CE) or high performance liquid chromatography (HPLC) with UV detection methods was successfully developed for the determination of trace levels of the anti-diabetic drug, rosiglitazone (ROSI) in biological fluids. The analyte was extracted into dihexyl ether that was immobilized in the wall pores of a porous hollow fiber from 10 mL of aqueous sample, pH 9.5 (donor phase), and was back extracted into the acceptor phase that contained 0.1M HCl located in the lumen of the hollow fiber. Parameters affecting the extraction process such as type of extraction solvent, HCl concentration, donor phase pH, extraction time, stirring speed, and salt addition were studied and optimized. Under the optimized conditions (extraction solvent, dihexyl ether; donor phase pH, 9.5; acceptor phase, 0.1M HCl; stirring speed, 600 rpm; extraction time, 30 min; without addition of salt), enrichment factor of 280 was obtained. Good linearity and correlation coefficients of the analyte was obtained over the concentration ranges of 1.0-500 and 5.0-500 ng mL(-1) for the HPLC (r(2)=0.9988) and CE (r(2)=0.9967) methods, respectively. The limits of detection (LOD) and limits of quantitation (LOQ) for the HPLC and CE methods were (0.18, 2.83) and (0.56, 5.00) ng mL(-1), respectively. The percent relative standard deviation (n=6) for the extraction and determination of three concentration levels (10, 250, 500 ng mL(-1)) of ROSI using the HPLC and CE methods were less than 10.9% and 13.2%, respectively. The developed methods are simple, rapid, sensitive and are suitable for the determination of trace amounts of ROSI in biological fluids.


Journal of Pharmaceutical and Biomedical Analysis | 2011

Stability-indicating micellar electrokinetic chromatography method for the analysis of sumatriptan succinate in pharmaceutical formulations

Khaldun M. Al Azzam; Bahruddin Saad; Chai Yuan Tat; Ishak Mat; Hassan Y. Aboul-Enein

A micellar electrokinetic chromatography method for the determination of sumatriptan succinate in pharmaceutical formulations was developed. The effects of several factors such as pH, surfactant and buffer concentration, applied voltage, capillary temperature, and injection time were investigated. Separation took about 5 min using phenobarbital as internal standard. The separation was carried out in reversed polarity mode at 20 °C, 26 kV and using hydrodynamic injection for 10s. Separation was achieved using a bare fused-silica capillary 50 μm×40 cm and background electrolyte of 25 mM sodium dihydrogen phosphate-adjusted with concentrated phosphoric acid to pH 2.2, containing 125 mM sodium dodecyl sulfate and detection was at 226 nm. The method was validated with respect to linearity, limits of detection and quantification, accuracy, precision and selectivity. The calibration curve was linear over the range of 100-2000 μg mL(-1). The relative standard deviations of intra-day and inter-day precision for migration time, peak area, corrected peak area, ratio of corrected peak area and ratio of peak area were less than 0.68, 3.48, 3.28, 2.97 and 2.83% and 2.01, 5.50, 4.46, 4.92 and 4.07%, respectively. The proposed method was successfully applied to the determinations of the analyte in tablet. Forced degradation studies were conducted by introducing a sample of sumatriptan succinate standard solution to different forced degradation conditions using neutral (water), basic (0.1 M NaOH), acidic (0.1 M HCl), oxidative (10% H(2)O(2)) and photolytic (exposure to UV light at 254 nm for 2 h). It is concluded that the stability-indicating method for sumatriptan succinate can be used for the analysis of the drug in various samples.


Biomedical Chromatography | 2009

Assay and stability‐indicating micellar electrokinetic chromatography method for the simultaneous determination of valacyclovir, acyclovir and their major impurity guanine in pharmaceutical formulations

Khaldun M. Al Azzam; Bahruddin Saad; Ahmad Makahleah; Hassan Y. Aboul-Enein; Abdalla A. Elbashir

A micellar electrokinetic chromatography (MEKC) method for the simultaneous determination of the antiviral drugs acyclovir and valacyclovir and their major impurity, guanine, was developed. The influences of several factors (surfactant and buffer concentration, pH, applied voltage, capillary temperature and injection time) were studied. Using tyramine hydrochloride as internal standard, the analytes were all separated in about 4 min. The separation was carried out in reversed polarity mode at 28 degrees C, 25 kV and using hydrodynamic injection (15 s). The separation was effected in a fused-silica capillary 100 microm x 56 cm and a background electrolyte of 20 mM citric acid-1 M Tris solution (pH 2.75), containing 125 mM sodium dodecyl sulphate and detection at 254 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 0.1-1 microg/mL (guanine) and from 0.1 to 120 microg/mL for both valacyclovir and acyclovir. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 5.0%. The proposed method was successfully applied to the determination of the analytes in tablets and creams. From the previous study it is concluded that the stability-indicating method developed for acyclovir and valacyclovir can be used for analysis of the drug in various stability samples.


Analytical Letters | 2009

Simultaneous Determination of Atenolol and Chlorthalidone in Pharmaceutical Preparations by Capillary-Zone Electrophoresis

Khaldun M. Al Azzam; Abdalla A. Elbashir; Mohammed A. Elbashir; Bahruddin Saad; Shafida Abdul Hamid

Abstract A capillary zone electrophoresis (CZE) method for the simultaneous determination of the β-blocker drugs atenolol and chlorthalidone in pharmaceutical formulations has been developed. The CZE separation was performed under the following conditions: capillary temperature, 25°C; applied voltage, 25 kV; 20 mM H3PO4–NaOH running buffer (pH 9.0); and detection wavelength, 198 nm. Phenobarbital was used as internal standard. The method was validated and showed not only good precision and accuracy but also good robustness. The method has been successfully applied to the simultaneous determination of both atenolol and chlorthalidone in pharmaceutical tablets.


Talanta | 2012

Micellar electrokinetic chromatography method for the simultaneous determination of furanic compounds in honey and vegetable oils

Yong Foo Wong; Ahmad Makahleh; Khaldun M. Al Azzam; Noorfatimah Yahaya; Bahruddin Saad; Siti Amrah Sulaiman

A simple micellar electrokinetic chromatography (MEKC) method for the simultaneous determination of 2-furfural (2-F), 3-furfural (3-F), 5-methylfurfural (5-MF), 5-hydroxymethylfurfural (5-HMF), 2-furoic acid (2-FA) and 3-furoic acid (3-FA) in honey and vegetable oils is described. Parameters affecting the separation such as pH, buffer and surfactant concentrations, applied voltage, capillary temperature, injection time and capillary length were studied and optimized. The separation was carried out in normal polarity mode at 20 °C, 22 kV and using hydrodynamic injection (17 s). The separation was achieved in a bare fused-silica capillary (46 cm × 50 μm i.d.) with a background electrolyte of 75 mM phosphoric acid (pH 7.3), containing 200 mM of sodium dodecyl sulphate (SDS). The detection wavelengths were at 200 nm (2-FA and 3-FA) and 280 nm (2-F, 3-F, 5-MF, 5-HMF). The furfurals were well separated in less than 20 min. The method was validated in terms of linearity, limit of detection and quantitation, precision and recoveries. Calibration curves of the six furfurals were well correlated (r(2)>0.991) within the range 1-25 μg mL(-1). Relative standard deviations of intra- and inter-day migration times and corrected peak areas ≤9.96% were achieved. The limit of detection (signal:noise, 3) was 0.33-0.70 μg mL(-1) whereas the limit of quantitation (signal:noise, 10) was 1.00-2.12 μg mL(-1). The method was applied to the determination of furanic compounds in honeys and vegetable oils (palm, walnut, grape seed and rapeseed). The effects of thermal treatment and gamma irradiation on the formation of the furanic compounds in honey were also investigated.


Biomedical Chromatography | 2010

Simultaneous determination of atenolol, chlorthalidone and amiloride in pharmaceutical preparations by capillary zone electrophoresis with ultraviolet detection

Khaldun M. Al Azzam; Bahruddin Saad; Hassan Y. Aboul-Enein

Capillary zone electrophoresis methods for the simultaneous determination of the beta-blocker drugs, atenolol, chlorthalidone and amiloride, in pharmaceutical formulations have been developed. The influences of several factors (buffer pH, concentration, applied voltage, capillary temperature and injection time) were studied. Using phenobarbital as internal standard, the analytes were all separated in less than 4 min. The separation was carried out in normal polarity mode at 25 degrees C, 25 kV and using hydrodynamic injection (10 s). The separation was effected in an uncoated fused-silica capillary (75 mum i.d. x 52 cm) and a background electrolyte of 25 mm H(3)PO(4) adjusted with 1 m NaOH solution (pH 9.0) and detection at 198 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 1-250 microg/mL for atenolol and chlorthalidone and from 2.5-250 microg/mL for amiloride. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol, chlorthalidone and amiloride in various pharmaceutical tablets formulations.


Biomedical Chromatography | 2010

Simultaneous determination of atenolol and amiloride in pharmaceutical preparations by capillary zone electrophoresis with capacitively coupled contactless conductivity detection.

Khaldun M. Al Azzam; Bahruddin Saad; Hassan Y. Aboul-Enein

Capillary zone electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE-C(4)D) has been employed for the determination of atenolol and amiloride in pharmaceutical formulations. Acetic acid (150 mm) was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature and injection time) was studied. Non-UV-absorbing L-valine was used as internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28 degrees C, 25 kV and using hydrodynamic injection (25 s). The separation was effected in an uncoated fused-silica capillary (75 microm, i.d. x 52 cm). The CE-C(4)D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 5-250 microg/mL for the studied analytes. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol and amiloride in different pharmaceutical tablet formulations.


Journal of Liquid Chromatography & Related Technologies | 2016

Recent advances in analysis of hazardous genotoxic impurities in pharmaceuticals by HPLC, GC, and CE

Khaldun M. Al Azzam; Hassan Y. Aboul-Enein

ABSTRACT Nowadays, genotoxic impurities in pharmaceuticals at lower levels are of increasing concerns not only to pharmaceutical industries but also for the regulatory agencies due to their risks for human carcinogenesis and, thus, requiring manufacturers to pay extra attention for their analysis and control. The need to determine these impurities at trace levels, based on the threshold of toxicological and daily dose, taking into consideration the often reactive and labile nature of genotoxic impurities, which poses significant analytical challenges. Therefore, sensitive and sophisticated analytical methodologies are deemed necessary in order to be able to test and control genotoxic impurities in drug substances. This review demonstrates the approaches reported in the literature for the analysis of the hazardous genotoxic impurities and the strategies used to enhance the sensitivity such as using ion spray-mass spectrometry and the separation techniques for the analysis of such impurities. GRAPHICAL ABSTRACT


Methods of Molecular Biology | 2013

Simultaneous Determination of Atenolol and Amiloride by Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection (C 4 D)

Khaldun M. Al Azzam; Hassan Y. Aboul-Enein

Capillary electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE-C(4)D) has been employed for the determination of the β-blocker drugs (atenolol and amiloride) in pharmaceutical formulations. 150 mM acetic acid was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature, and injection time) was studied. Non-UV absorbing L-valine was used as an internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28 °C, 25 kV, and using hydrodynamic injection (25 s). The separation was effected in a bare fused-silica capillary 75 μm × 52 cm. The CE-C(4)D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision, and selectivity. Calibration curves were linear over the range 5-250 μg mL(-1) for the studied analytes. The relative standard deviations of intra- and inter-day precisions of migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of the β-blocker drugs in different pharmaceutical tablets.

Collaboration


Dive into the Khaldun M. Al Azzam's collaboration.

Top Co-Authors

Avatar

Bahruddin Saad

Universiti Sains Malaysia

View shared research outputs
Top Co-Authors

Avatar

Hassan Y. Aboul-Enein

Universiti Teknologi Malaysia

View shared research outputs
Top Co-Authors

Avatar

Ahmad Makahleah

Universiti Sains Malaysia

View shared research outputs
Top Co-Authors

Avatar

Rohana Adnan

Universiti Sains Malaysia

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ahmad Makahleh

Universiti Sains Malaysia

View shared research outputs
Top Co-Authors

Avatar

Chai Yuan Tat

Universiti Sains Malaysia

View shared research outputs
Researchain Logo
Decentralizing Knowledge