conference of the industrial electronics society | 2009
Hauke Langkowski; Trung Do Thanh; Klaus-Dieter Dettmann; Detlef Schulz
As the power of renewable energy plants is increasing, their impact on the power quality becomes more and more important. The occurring grid feedback is related to the grid impedance. Therefore the exact measurement of the grid impedance is necessary. In this paper simulations of a windfarm grid integration scenario are presented that show the advantages of a grid impedance measurement in context of harmonics. In addition methods to determine the frequency dependent grid impedances are outlined and the influence of the virtual-starpoint on the calculations is examined. Based on the examinations a novel method to identify the real grid impedances is proposed.
Electrical Power Quality and Utilisation. Journal | 2007
Klaus-Dieter Dettmann; Steffen Schostan; Detlef Schulz
For wind turbines that feed into public grids limits for voltage and current harmonics must be assured. To verify that the actual levels are valid, measurements are necessary. Problems can occur to determine which part of these harmonics has its origin in the wind turbine. It is shown that also harmonics which originally have zero sequences can be transferred over a delta-star-transformer, if the currents of the wind turbine are asymmetric due to unbalanced loads. Measurements in an existing wind turbine configuration are discussed, which confirm the described effects.
2008 International School on Nonsinusoidal Currents and Compensation | 2008
Trung Do Thanh; Steffen Schostan; Klaus-Dieter Dettmann; Detlef Schulz
At low-voltage level there is already a commercial measurement device that is able to identify the grid impedance in dependency of time and frequency. Since at the low-voltage level a four-wire system and at the medium-and high-voltage level a three-wire system is installed, the method to identify the grid impedance has to be varied. This paper proposes a method that could be applied for the identification of the time and frequency dependent grid impedance at the medium- and high-voltage level. Another aspect that has to be considered is how to dimension the variable switched resistive load, which is necessary to stimulate the grid. The power-range of this load is limited by the maximum allowable voltage drop in the grid. Furthermore it is important to investigate what kind of power terms are caused by the nonsinusoidal stimulation of the grid in balanced and unbalanced configurations. For this purpose the power theory of Fryze is applied.
2010 International School on Nonsinusoidal Currents and Compensation | 2010
Steffen Schostan; Klaus-Dieter Dettmann; Ilir Purellku; Detlef Schulz
Wind energy converters feeding into the power grid must comply with standards for harmonics. In practice harmonics or subharmonics caused by the generator are difficult to measure, because the grid itself is also distorted. This paper describes test-bench measurements that are performed with an ideal balanced and sinusoidal voltage source instead of a grid. The results show, which significant frequencies the generator and the converter produce and how they interact with the grid. Sources for these frequencies are explained. The stator side collective power components are calculated and their effect on the time variable asymmetry of the stator current of the three-phase system is investigated.
2009 Compatibility and Power Electronics | 2009
Steffen Schostan; Klaus-Dieter Dettmann; Trung Do Thanh; Detlef Schulz
This paper describes how harmonics up to some hundreds of Hz propagate from stator to rotor and vice versa in a doubly fed induction generator of a wind energy converter. Some of these harmonics are impressed by the grid, some are created by asymmetries of its voltages and currents; others originate in the wind turbine. At a test bench measurements have been made to investigate harmonics for one sub-synchronous and one super-synchronous operating point. The results show, how sources of harmonics in the generator can be identified and offer possibilities to compensate certain stator harmonics with the rotor side converter.
Archive | 2017
A. Akhrorova; F. Boboev; M. Halimjanova; Klaus-Dieter Dettmann; Detlef Schulz
This article describes the energy potential of the Republic of Tajikistan and possibilities of its use for a sustainable development of neighbouring countries in the Central Asian region. Underproduction of electric power with hydroelectric power stations (HPP) due to idle water flow in summertime leads to economic lasses for electric power companies in Tajikistan and the whole Central Asian region. These economic lasses are quantitatively estimated, based on researches of efficient use of the hydro power potential in Tajikistan. As a result, a diversification of the countrys energy sources is necessary as well as the formation of a regional hydro power energy market. Thus, the national power companies would get increased capabilities to repay their foreign loans.
Archive | 2013
Klaus Heuck; Klaus-Dieter Dettmann; Detlef Schulz
Zur Erzeugung elektrischer Energie werden heute im wesentlichen Wasser, fossile Brennstoffe und Kernenergie herangezogen. Die in diesen naturlichen Energietragern enthaltene Energie wird, wie bereits erwahnt, als Primarenergie bezeichnet. Die Umwandlung dieser Primarenergie in elektrische Energie erfolgt vorwiegend in fossil befeuerten Kraftwerken, Wasser- und Kernkraftwerken [136]. Das Ziel dieses Kapitels besteht darin, die Grundzuge dieser Energieumwandlung zu vermitteln. Dies erfolgt jedoch nur in dem Umfang, wie es als Hintergrundwissen fur das Verstandnis der Probleme bei der elektrischen Energieverteilung erforderlich ist.
Archive | 2013
Klaus Heuck; Klaus-Dieter Dettmann; Detlef Schulz
Zunachst seien einige Begriffe erlautert. Unter der Bezeichnung Betriebsfuhrung sollen alle Masnahmen verstanden werden, die zum Betreiben einer Energieanlage notwendig sind. Dazu gehoren der bedarfsgerechte Einsatz von Kraftwerken, die Netzfuhrung, die Instandsetzung und Wartung der Anlagen sowie die Zahlung aller erbrachten Leistungen fur die Netznutzer. Der Ausdruck Netzfuhrung beinhaltet nur die Masnahmen, die zur Steuerung des Netzes notwendig sind wie z. B. Schalthandlungen.
Archive | 2013
Klaus Heuck; Klaus-Dieter Dettmann; Detlef Schulz
In der elektrischen Energietechnik werden fur die Effektivwerte der Wechselstrome und Wechselspannungen die grosen Buchstaben I und U verwendet. Sollen mit diesen Grosen spezielle Betriebszustande gekennzeichnet werden, so ist eine Indizierung mit kleinen Buchstaben vorzusehen. Gilt es dagegen, einen Ort bzw. ein Betriebsmittel innerhalb eines Netzes zu lokalisieren oder sogar eine ganze Netzebene zu kennzeichnen, so wird fur den Index ein groser Buchstabe gewahlt. Im Falle einer Mehrfachindizierung ist die Reihenfolge vorgeschrieben. Zuerst kommt der Betriebszustand, danach wird der ortliche Bereich charakterisiert. Dabei gilt der Grundsatz, dass erst der umfassendere und dann der speziellere Index auftreten soll (DIN EN 60027-7 und DIN 40108).
Archive | 2013
Klaus Heuck; Klaus-Dieter Dettmann; Detlef Schulz
Ein dreipoliger Kurzschluss bewirkt eine sehr extreme Zustandsanderung. Die dadurch ausgelosten Wirkungen auf das Strom-Spannungs-Verhalten stellen daher sowohl fur das einzelne Betriebsmittel als auch fur die gesamte Netzanlage eine harte Beanspruchung dar. Halt ein Netz unabhangig vom Fehlerort diesen Belastungen stand, so wird es als kurzschlussfest bezeichnet. Ein Netz muss allerdings nicht nur kurzschlussfest sein, sondern auch die Auslegungskriterien fur die Spannungsfestigkeit (s. Abschnitt 4.12) erfullen sowie die Bedingungen des Normalbetriebs einhalten, die in Kapitel 5 beschrieben sind. Dort sind noch keine Dimensionierungskriterien fur Schalter angegeben; sie werden im Weiteren zusammen mit den Auslegungskriterien fur die Kurzschlussfestigkeit erlautert. Zunachst wird jedoch auf eine unmittelbare Kurzschlusswirkung an der Fehlerstelle – den Lichtbogen – eingegangen