Acta Biomaterialia | 2016

Novel method for the generation of tissue-engineered vascular grafts based on a highly compacted fibrin matrix.

Thomas Aper; Mathias Wilhelmi; Christin Gebhardt; Klaus Hoeffler; Nils Benecke; Andres Hilfiker; Axel Haverich

UNLABELLED The generation of tissue-engineered blood vessel substitutes remains an ongoing challenge for cardiovascular tissue engineering. Full biocompatibility and immediate availability have emerged as central issues for clinical use. To address these issues, we developed a technique that allows the generation of highly stable tubular fibrin segments. The process is based on the compaction of fibrin in a custom-made high-speed rotation mold. In an automated process, fibrin is precipitated from plasma by means of the Vivostat® system. Following application to the rotating mold, the fibrin was compacted by centrifugal force and excess fluid was pressed out. This compaction results in increasing cross-links between the fibrin fibrils and a corresponding significant increase of biomechanical stability up to a burst strength of 230mm of mercury. The molding process allows for a simultaneous seeding procedure. In a first in vivo evaluation in a sheep model, segments of the carotid artery were replaced by tissue-engineered vascular grafts, generated immediately prior to implantation (n=6). Following subjection to the bodys remodeling mechanisms, the segments showed a high structural similarity to a native artery after explantation at 6months. Thus, this technique may represent a powerful tool for the generation of biomechanically stable vascular grafts immediately prior to implantation. STATEMENT OF SIGNIFICANCE Fibrin has previously been shown to be suitable as a matrix for the seeding of different celltypes and for that reason was widely used as scaffold in different fields of tissue engineering. Nevertheless, fibrins lack of stability has strongly limited its application. Our study describes a novel moulding technique for the generation of a highly compacted fibrin matrix. Using this approach, it was possible to optimize the engineering process of tubular fibrin segments to provide bioartificial vascular grafts within one hour with sufficient stability for immediate implantation in the arterial system. Thus, this technique may represent a powerful tool to get closer to the ultimate aim of an optimal bioartificial vascular graft.


Interactive Cardiovascular and Thoracic Surgery | 2016

Aortic valve replacement with sutureless prosthesis: better than root enlargement to avoid patient-prosthesis mismatch?

Erik Beckmann; Andreas Martens; Firas Abd Alhadi; Klaus Hoeffler; Julia Umminger; Tim Kaufeld; Samir Sarikouch; Nurbol Koigeldiev; Serghei Cebotari; Jan D. Schmitto; Axel Haverich; Malakh Shrestha

OBJECTIVES Aortic valve replacement in patients with a small aortic annulus may result in patient-prosthesis mismatch (PPM). Aortic root enlargement (ARE) can reduce PPM, but leads to extended cardiac ischaemia times. Sutureless valves have the potential to prevent PPM while reducing cardiac ischaemia times. METHODS Between January 2007 and December 2011, a total of 128 patients with a small aortic annulus underwent surgery for aortic valve stenosis at our centre. Thirty-six (17% male, n = 6) patients received conventional valve replacement with ARE and 92 (16% male, n = 18) subjects received sutureless valve implantation (Sorin Perceval). We conducted a comparative, retrospective study with follow-up. RESULTS The sutureless group showed a significantly higher age (79 years) than the ARE patients (62 years, P < 0.001) and received significantly more concomitant cardiac procedures (33%, n = 30 vs 6%, n = 2, P = 0.001). The mean operation, cardiopulmonary bypass and cross-clamp times were significantly lower in sutureless patients (147 ± 42, 67 ± 26 and 35 ± 13 min, respectively) than in ARE patients (181 ± 41, 105 ± 29 and 70 ± 19 min, respectively, P < 0.001). The mean postoperative effective orifice area (EOA) indexed to the body surface area was 0.91 ± 0.2 cm(2)/m(2) in ARE patients and 0.83 ± 0.14 cm(2)/m(2) in sutureless patients (P = 0.040). The rate of patients with severe PPM was 6% (n = 2) in ARE patients and 11% (n = 8%) in sutureless patients (not significant, n.s.). The 30-day mortality rates were 2% (n = 2) in sutureless patients and 6% (n = 2) in ARE patients (n.s.). The 1- and 5-year survival rates of the sutureless group were 92 and 54% years, respectively, whereas the 1- and 5-year survival rates of the ARE group were 76% (n.s.). CONCLUSIONS Although the sutureless valve patients received significantly more concomitant procedures, all operation-associated times were significantly shorter. Despite sutureless valve patients being older, the 30-day mortality and survival rates were comparable in the two groups. Since the indexed EOA was only slightly lower and the incidence of severe PPM was not significantly higher in the sutureless valve patients, we conclude that sutureless valve implantation is an alternative to conventional ARE to treat a small aortic annulus and avoid PPM, especially in geriatric patients who benefit from the quick implantation process.


PLOS ONE | 2018

Treatment of infected lungs by ex vivo perfusion with high dose antibiotics and autotransplantation: A pilot study in pigs

Norman Zinne; Marcus Krueger; Doris Hoeltig; Burkhard Tuemmler; Erin C. Boyle; Christian Biancosino; Klaus Hoeffler; Peter Braubach; Taufiek Konrad Rajab; Anatol Ciubotaru; Judith Rohde; Karl-Heinz Waldmann; Axel Haverich

The emergence of multi-drug resistant bacteria threatens to end the era of antibiotics. Drug resistant bacteria have evolved mechanisms to overcome antibiotics at therapeutic doses and further dose increases are not possible due to systemic toxicity. Here we present a pilot study of ex vivo lung perfusion (EVLP) with high dose antibiotic therapy followed by autotransplantation as a new therapy of last resort for otherwise incurable multidrug resistant lung infections. Severe Pseudomonas aeruginosa pneumonia was induced in the lower left lungs (LLL) of 18 Mini-Lewe pigs. Animals in the control group (n = 6) did not receive colistin. Animals in the conventional treatment group (n = 6) received intravenous application of 2 mg/kg body weight colistin daily. Animals in the EVLP group (n = 6) had their LLL explanted and perfused ex vivo with a perfusion solution containing 200 μg/ml colistin. After two hours of ex vivo treatment, autotransplantation of the LLL was performed. All animals were followed for 4 days following the initiation of treatment. In the control and conventional treatment groups, the infection-related mortality rate after five days was 66.7%. In the EVLP group, there was one infection-related mortality and one procedure-related mortality, for an overall mortality rate of 33.3%. Moreover, the clinical symptoms of infection were less severe in the EVLP group than the other groups. Ex vivo lung perfusion with very high dose antibiotics presents a new therapeutic option of last resort for otherwise incurable multidrug resistant pneumonia without toxic side effects on other organs.


Transplant International | 2017

Irradiation before and donor splenocyte infusion immediately after transplantation induce tolerance to lung, but not heart allografts in miniature swine

W. Sommer; G. Buechler; K. Jansson; M. Avsar; A.-K. Knöfel; J. Salman; Klaus Hoeffler; T. Siemeni; Jens Gottlieb; Johann H. Karstens; Danny Jonigk; Ansgar Reising; Axel Haverich; Martin Strüber; G. Warnecke

Solid organs may differ in their potential to induce and maintain a state of donor‐specific tolerance. Previously, we induced stable immunological tolerance in a lung transplantation model in miniature swine. Here, we wished to transfer this established protocol into a heart transplantation model in miniature swine. Heterotopic heart transplantation (HTX) was performed in four and left‐sided lung transplantation (LTX) in seven minipigs from gender‐ and SLA‐mismatched donors. All recipients received nonmyeloablative irradiation, donor splenocyte infusion and intravenous pharmacologic immunosuppression for 28 postoperative days. All transplanted hearts were rejected within 95 days. In contrast, four animals of the LTX group developed stable tolerance surviving beyond 500 days, and three further animals rejected 119, 239 and 360 days post‐transplantation. In both groups, peripheral blood donor leucocyte chimerism peaked 1 h after reperfusion of the allograft. Importantly, the early chimerism level in the LTX group was significantly higher compared to the HTX group and remained detectable throughout the entire observation period. In conclusion, lungs and hearts vary in their potential to induce a state of tolerance after transplantation in a protocol with pre‐operative recipient irradiation and donor splenocyte co‐transplantation. This could be due to differential early levels of passenger leucocyte chimerism.


BioNanoMaterials | 2016

Engineering of small diameter tubular compacted fibrin matrices

Thomas Aper; Mathias Wilhelmi; Klaus Hoeffler; Nils Benecke; Axel Haverich

Abstract Fibrin is widely used in different approaches of tissue engineering. Nevertheless, poor biomechanical strength restricts its use namely in cardiovascular tissue engineering. We have recently developed a novel moulding technique for the generation of highly stable fibrin tubes. The purpose of this study was the application of this method to the generation of small calibre fibrin tubes for the generation of bioartificial vascular grafts with a diameter of 3 mm. Therefore, a fibrinogen preparation was separated from plasma by means of cryoprecipitation and applied to a high-speed rotating casting mould in a low concentration to achieve slow polymerization and thereby uniform distribution of the fibrinogen. Thus, uniformly moulded 10 cm long fibrin tubes with a diameter of 3 mm were generated from 145±22 mg fibrinogen precipitated from 50 mL plasma. Thickness of the wall (522±57 μm) and biomechanical strength (47.4±11.1 kPa) were equable over the whole length of the tubes. Burst strength was 367±49 mm Hg. Thus, the developed technique enables the generation of tubular fibrin segments with a high biomechanical stability and represents a powerful tool for the generation of custom-made bioartificial vascular grafts.


Journal of Visualized Experiments | 2018

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse

N. Madrahimov; Abdurasul Khalikov; Erin C. Boyle; Ruslan Natanov; A. Knoefel; T. Siemeni; Klaus Hoeffler; Axel Haverich; Ulrich A. Maus; C. Kuehn

The use of extracorporeal membrane oxygenation (ECMO) has increased substantially in recent years. ECMO has become a reliable and effective therapy for acute as well as end-stage lung diseases. With the increase in clinical demand and prolonged use of ECMO, procedural optimization and prevention of multi-organ damage are of critical importance. The aim of this protocol is to present a detailed technique of veno-venous ECMO in a non-intubated, spontaneously breathing mouse. This protocol demonstrates the technical design of the ECMO and surgical steps. This murine ECMO model will facilitate the study of pathophysiology related to ECMO (e.g., inflammation,bleeding and thromboembolic events). Due to the abundance of genetically modified mice, the molecular mechanisms involved in ECMO-related complications can also be dissected.


European Journal of Cardio-Thoracic Surgery | 2018

Decellularized mitral valve in a long-term sheep model

Pavel Iablonskii; Serghei Cebotari; Anatol Ciubotaru; Samir Sarikouch; Klaus Hoeffler; Andres Hilfiker; Axel Haverich; I. Tudorache

OBJECTIVES The objective of this study was to evaluate surgical handling, in vivo hemodynamic performance and morphological characteristics of decellularized mitral valves (DMVs) in a long-term sheep model. METHODS Ovine mitral valves were decellularized using detergents and β-mercaptoethanol. Orthotopic implantations were performed in 6-month-old sheep (41.3 ± 1.2 kg, n = 11) without annulus reinforcement. Commercially available stented porcine aortic valves [biological mitral valve (BMV), n = 3] were implanted conventionally and used as controls. Valve function was evaluated by transoesophageal echocardiography and explants were investigated by a routine bright field microscopy and immunofluorescent histology. RESULTS During implantation, 2 DMVs required cleft closure of the anterior leaflet. All valves were competent on water test and early postoperative transoesophageal echocardiography. Six animals (DMV, n = 4; BMV, n = 2) survived 12 months. Six animals died within the first 4 months due to valve-related complications. At 12 months, transoesophageal echocardiography revealed severe degeneration in all BMVs. Macroscopically, BMV revealed calcification at the commissures and leaflet insertion area. Histological examination showed sporadic cells negative for endothelial nitric oxide synthase, von Willebrand factor and CD45 on their surface. In contrast, DMV showed no calcification or stenosis, and the regurgitation was trivial to moderate in all animals. Fibrotic hardening occurred only along the suture line of the valve annulus, immunostaining revealed collagen IV covering the entire leaflet surface and a repopulation with endothelial cells. CONCLUSIONS Surgical implantation of DMV is feasible and results in good early graft function. Additional in vivo investigations are required to minimize the procedure-related complications and to increase the reproducibility of surgical implantation. Degenerative profile of allogeneic DMV is superior to commercially available porcine aortic prosthesis.


American Journal of Transplantation | 2018

Prediction of transplant outcome after 24-hour ex vivo lung perfusion using the Organ Care System in a porcine lung transplantation model

W. Sommer; J. Salman; M. Avsar; Klaus Hoeffler; K. Jansson; T. Siemeni; A. Knoefel; Linda Ahrens; Reza Poyanmehr; I. Tudorache; Peter Braubach; Danny Jonigk; Axel Haverich; G. Warnecke

Ex vivo lung perfusion (EVLP) has become routine practice in lung transplantation. Still, running periods exceeding 12 hours have not been undertaken clinically to date, and it remains unclear how the perfusion solution for extended running periods should be composed and which parameters may predict outcomes. Twenty‐four porcine lungs underwent EVLP for 24 hours using the Organ Care System (OCS). Lungs were ventilated and perfused with STEENs solution enriched with erythrocytes (n = 8), acellular STEENs solution (n = 8), or low‐potassium dextran (LPD) solution enriched with erythrocytes (n = 8). After 24 hours, the left lungs were transplanted into recipient pigs. After clamping of the contralateral lung, the recipients were observed for 6 hours. The most favorable outcome was observed in organs utilizing STEEN solution enriched with erythrocytes as perfusate, whereas the least favorable outcome was seen with LPD solution enriched with erythrocytes for perfusion. Animals surviving the observation period showed lower peak airway pressure (PAWP) and pulmonary vascular resistance (PVR) during OCS preservation. The results suggest that transplantation of lungs following 24 hours of EVLP is feasible but dependent on the composition of the perfusate. PAWP and PVR during EVLP are early and late predictors of transplant outcome, respectively.


Biomaterials | 2006

In vitro re-endothelialization of detergent decellularized heart valves under simulated physiological dynamic conditions

Artur Lichtenberg; I. Tudorache; Serghei Cebotari; Stefanie Ringes-Lichtenberg; Gerrit Sturz; Klaus Hoeffler; Christof Hurscheler; Gudrun Brandes; Andres Hilfiker; Axel Haverich


European Journal of Cardio-Thoracic Surgery | 2004

Hypothermic circulatory arrest with and without cold selective antegrade cerebral perfusion: impact on neurological recovery and tissue metabolism in an acute porcine model

Christian Hagl; Sven Peterss; Klaus Hoeffler; Michael Winterhalter; Matthias Karck; Axel Haverich

Collaboration


Dive into the Klaus Hoeffler's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

I. Tudorache

Hannover Medical School

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

G. Warnecke

Hannover Medical School

View shared research outputs
Top Co-Authors

Avatar

K. Jansson

Hannover Medical School

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge