Kodela Vani
Boston University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Kodela Vani.
American Journal of Clinical Pathology | 2006
Seshi R. Sompuram; Kodela Vani; Laurie J. Hafer; Steven A. Bogen
It is not clearly understood why some monoclonal antibodies bind to their antigens informalin-fixed, paraffin-embedded tissue sections but others do not. To address this question, we analyzed the protein epitopes of 9 monoclonal antibodies that are immunoreactive after formalin fixation and antigen retrieval. We identified the antibody contact sites by using phage display and synthesized corresponding peptides derived from the GenBank database sequence that contain the predicted antibody binding sites. Our data indicate that all 9 antibodies bind to linear epitopes, ie, composed of contiguous amino acids. In addition, the amino acids proline, tyrosine, glutamine, and leucine are highly represented in these antibody contact sites. The epitopes tend to be mildly to moderately hydrophilic. These findings are the first detailed studies of antibody epitopes associated with antigen retrieval and suggest that antibodies must recognize linear sequences to bind after formalin fixation and antigen retrieval.
Biotechnic & Histochemistry | 2009
Steven A. Bogen; Kodela Vani; Seshi R. Sompuram
Abstract The overwhelming majority of antibodies useful for formalin fixed, paraffin embedded (FFPE) tissues require antigen retrieval to reverse the effect of formalin fixation and re-establish immunoreactivity. How this reversal happens is poorly understood. We developed a new experimental model for studying the mechanism of formalin fixation and antigen retrieval. Epitope mapping studies on nine antibodies useful for FFPE tissues revealed that each consisted of a contiguous stretch of amino acids in the native protein (linear epitope). Small peptides representing the epitopes of antibodies to human epidermal growth factor receptor type (HER2), estrogen, and progesterone receptors were attached covalently to glass microscope slides in a peptide array. Most peptides retained immunoreactivity after formalin fixation. Immunoreactivity was completely abrogated for all peptides, however, if an irrelevant large protein was present during formalin-induced cross-linking. We hypothesize that cross-linking the irrelevant protein to the peptide epitopes sterically blocked antibodies from binding. Antigen retrieval dissociates irrelevant proteins and restores immunoreactivity. Because the epitopes for clinical antibodies require only primary protein structure, the fact that antigen retrieval probably denatures the secondary and tertiary structure of the protein is irrelevant. The same mechanism may occur in tissue samples subjected to formalin fixation and antigen retrieval.
Molecular & Cellular Proteomics | 2008
Gerassimos Bastas; Seshi R. Sompuram; Brian G. Pierce; Kodela Vani; Steven A. Bogen
We describe a new approach to identify proteins involved in disease pathogenesis. The technology, Epitope-Mediated Antigen Prediction (E-MAP), leverages the specificity of patients’ immune responses to disease-relevant targets and requires no prior knowledge about the protein. E-MAP links pathologic antibodies of unknown specificity, isolated from patient sera, to their cognate antigens in the protein database. The E-MAP process first involves reconstruction of a predicted epitope using a peptide combinatorial library. We then search the protein database for closely matching amino acid sequences. Previously published attempts to identify unknown antibody targets in this manner have largely been unsuccessful for two reasons: 1) short predicted epitopes yield too many irrelevant matches from a database search and 2) the epitopes may not accurately represent the native antigen with sufficient fidelity. Using an in silico model, we demonstrate the critical threshold requirements for epitope length and epitope fidelity. We find that epitopes generally need to have at least seven amino acids, with an overall accuracy of >70% to the native protein, in order to correctly identify the protein in a nonredundant protein database search. We then confirmed these findings experimentally, using the predicted epitopes for four monoclonal antibodies. Since many predicted epitopes often fail to achieve the seven amino acid threshold, we demonstrate the efficacy of paired epitope searches. This is the first systematic analysis of the computational framework to make this approach viable, coupled with experimental validation.
Applied Immunohistochemistry & Molecular Morphology | 2009
Steven A. Bogen; Kodela Vani; Brian McGraw; Vin Federico; Iqbal Habib; Ron Zeheb; Ed Luther; Colin Tristram; Seshi R. Sompuram
Peptide immunohistochemistry (IHC) controls are a new quality control format for verifying proper IHC assay performance, offering advantages in high throughput automated manufacture and standardization. We previously demonstrated that formalin-fixed peptide epitopes, covalently attached to glass microscope slides, behaved (immunochemically) in a similar fashion to the native protein in tissue sections. To convert this promising idea into a practical clinical laboratory quality control tool, we tested the hypothesis that the quality assurance information provided by peptide IHC controls accurately reflects IHC staining performance among a diverse group of clinical laboratories. To test the hypothesis, we first designed and built an instrument for reproducibly printing the controls on microscope slides and a simple software program to measure the color intensity of stained controls. Automated printing of peptide spots was reproducible, with coefficients of variation of 4% to 8%. Moreover, the peptide controls were stable at ≤4°C for at least 7 months, the longest time duration we tested. A national study of 109 participating clinical laboratories demonstrated a good correlation between a laboratorys ability to properly stain formalin-fixed peptide controls to their ability in properly staining a 3+ HER-2 formalin-fixed tissue section mounted on the same slide (r=0.87). Therefore, peptide IHC controls accurately reflect the analytical component of an IHC stain, including antigen retrieval. Besides its use in proficiency survey testing, we also demonstrate the feasibility of applying peptide IHC controls for verifying intralaboratory IHC staining consistency, using Levy-Jennings charting.
Journal of Histotechnology | 2003
Seshi R. Sompuram; Deirdre McMahon; Kodela Vani; Halasya Ramanathan; Steven A. Bogen
Abstract We describe a protected isocyanate (PI) microscope slide-coating technology that significantly enhances tissue section adhesion. This technology is particularly useful for problematic tissue sections that detach during staining. The glass slide coating is unique in that it involves a highly reactive covalent coupling to cellular proteins. Namely, we coat the slides with a modified isocyanate group capable of binding to amine, hydroxyl, and carboxylic functionalities on cells and tissue sections. This contrasts to presently available slide coatings, which primarily provide a weak charge interaction with tissue proteins. We compared the tissue adhesiveness of our isocyanate-coated slides to commercially available aminosilane (“plus”), poly-L-lysine, and polysineTM slides. Serial tissue sections were mounted on PI-coated slides versus one of the other existing coatings and treated in an otherwise-identical manner for staining. In instances where tissue adhesion was problematic, PI-coated slides produced better tissue retention almost every time. The difference was sometimes dramatic and of significant diagnostic value. We believe that this technology can be useful for capturingt issue sections that otherwise will not adhere well to glass slides. (The J Histotechnol 26:117, 2003) Submitted November 4, 2002; Accepted with revisions April 7, 2003
Journal of Histochemistry and Cytochemistry | 2015
Seshi R. Sompuram; Kodela Vani; Brian H. Tracey; Debra A. Kamstock; Steven A. Bogen
A new standardized immunohistochemistry (IHC) control for breast cancer testing comprises formalin-fixed human epidermal growth factor receptor 2, estrogen receptor, or progesterone receptor peptide antigens covalently attached to 8-µm glass beads. The antigen-coated beads are suspended in a liquid matrix that hardens upon pipetting onto a glass microscope slide. The antigen-coated beads remain in place through deparaffinization, antigen retrieval, and immunostaining. The intensity of the beads’ stain provides feedback regarding the efficacy of both antigen retrieval and immunostaining. As a first report, we tested the sensitivity and specificity of the new IHC controls (“IHControls”). To evaluate sensitivity, various staining problems were simulated. IHControls detected primary and secondary reagent degradation similarly to tissue controls. This first group of IHControls behaved similarly to tissue controls expressing high concentrations of the antigen. The IHControls were also able to detect aberrations in antigen retrieval, as simulated by sub-optimal times or temperatures. Specificity testing revealed that each antigen-coated bead was specific for its cognate IHC test antibody. The data support the conclusion that, like tissue controls, IHControls are capable of verifying the analytic components of an immunohistochemical stain. Unlike tissue controls, IHControls are prepared in large bulk lots, fostering day-to-day reproducibility that can be standardized across laboratories.
Archives of Pathology & Laboratory Medicine | 2018
Seshi R. Sompuram; Kodela Vani; Anika K. Schaedle; Anuradha Balasubramanian; Steven A. Bogen
CONTEXT - Numerous studies highlight interlaboratory performance variability in diagnostic immunohistochemistry (IHC) testing. Despite substantial improvements over the years, the inability to quantitatively and objectively assess immunostain sensitivity complicates interlaboratory standardization. OBJECTIVE - To quantitatively and objectively assess the sensitivity of the immunohistochemical stains for human epidermal growth factor receptor type 2 (HER2), estrogen receptor (ER), and progesterone receptor (PR) across IHC laboratories in a proficiency testing format. We measure sensitivity with parameters that are new to the field of diagnostic IHC: analytic response curves and limits of detection. DESIGN - Thirty-nine diagnostic IHC laboratories stained a set of 3 slides, one each for HER2, ER, and PR. Each slide incorporated a positive tissue section and IHControls at 5 different concentrations. The IHControls comprise cell-sized clear microbeads coated with defined concentrations of analyte (HER2, ER, and/or PR). The laboratories identified the limits of detection and then mailed the slides for quantitative assessment. RESULTS - Each commercial immunostain demonstrated a characteristic analytic response curve, reflecting strong reproducibility among IHC laboratories using the same automation and reagents prepared per current Good Manufacturing Practices. However, when comparing different commercial vendors (using different reagents), the data reveal up to 100-fold differences in analytic sensitivity. For proficiency testing purposes, quantitative assessment using analytic response curves was superior to subjective interpretation of limits of detection. CONCLUSIONS - Assessment of IHC laboratory performance by quantitative measurement of analytic response curves is a powerful, objective tool for identifying outlier IHC laboratories. It uniquely evaluates immunostain performance across a range of defined analyte concentrations.
Applied Immunohistochemistry & Molecular Morphology | 2016
Kodela Vani; Seshi R. Sompuram; Stephen P. Naber; Jeffrey D. Goldsmith; Regan Fulton; Steven A. Bogen
Almost all clinical laboratory tests use objective, quantitative measures of quality control (QC), incorporating Levey-Jennings analysis and Westgard rules. Clinical immunohistochemistry (IHC) testing, in contrast, relies on subjective, qualitative QC review. The consequences of using Levey-Jennings analysis for QC assessment in clinical IHC testing are not known. To investigate this question, we conducted a 1- to 2-month pilot test wherein the QC for either human epidermal growth factor receptor 2 (HER-2) or progesterone receptor (PR) in 3 clinical IHC laboratories was quantified and analyzed with Levey-Jennings graphs. Moreover, conventional tissue controls were supplemented with a new QC comprised of HER-2 or PR peptide antigens coupled onto 8 &mgr;m glass beads. At institution 1, this more stringent analysis identified a decrease in the HER-2 tissue control that had escaped notice by subjective evaluation. The decrement was due to heterogeneity in the tissue control itself. At institution 2, we identified a 1-day sudden drop in the PR tissue control, also undetected by subjective evaluation, due to counterstain variability. At institution 3, a QC shift was identified, but only with 1 of 2 controls mounted on each slide. The QC shift was due to use of the instrument’s selective reagent drop zones dispense feature. None of these events affected patient diagnoses. These case examples illustrate that subjective QC evaluation of tissue controls can detect gross assay failure but not subtle changes. The fact that QC issues arose from each site, and in only a pilot study, suggests that immunohistochemical stain variability may be an underappreciated problem.
Journal of Histochemistry and Cytochemistry | 2017
Kodela Vani; Seshi R. Sompuram; Anika K. Schaedle; Anuradha Balasubramanian; Monika Pilichowska; Stephen P. Naber; Jeffrey D. Goldsmith; Kueikwun G. Chang; Farzad Noubary; Steven A. Bogen
Clinical Immunohistochemistry (IHC) laboratories face unique challenges in performing accurate and reproducible immunostains. Among these challenges is the use of homemade controls derived from pathological discard samples. Such positive controls have an unknown number of analyte molecules per cell (epitope density). It is unclear how the lack of defined analyte concentrations affects performance of the control. To address this question, we prepared positive IHC controls (IHControls) for human epidermal growth factor receptor type II (HER-2), estrogen receptor (ER), or progesterone receptor (PR) with well-defined, homogeneous, and reproducible analyte concentrations. Using the IHControls, we examined the effect of analyte concentration on IHC control sensitivity. IHControls and conventional tissue controls were evaluated in a series of simulated primary antibody reagent degradation experiments. The data demonstrate that the ability of a positive IHC control to reveal reagent degradation depends on (1) the analyte concentration in the control and (2) where that concentration falls on the immunostain’s analytic response curve. The most sensitive positive IHC controls have analyte concentrations within or close to the immunostain’s concentration-dependent response range. Strongly staining positive controls having analyte concentrations on the analytic response curve plateau are less sensitive. These findings emphasize the importance of selecting positive IHC controls that are of intermediate (rather than strong) stain intensity.
American Journal of Clinical Pathology | 2004
Seshi R. Sompuram; Kodela Vani; Elizabeth Messana; Steven A. Bogen