Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Koji Toma is active.

Publication


Featured researches published by Koji Toma.


Biosensors and Bioelectronics | 2015

An acetone bio-sniffer (gas phase biosensor) enabling assessment of lipid metabolism from exhaled breath

Ming Ye; Po-Jen Chien; Koji Toma; Takahiro Arakawa; Kohji Mitsubayashi

Several volatile organic compounds (VOCs) are released from human breath or skin. Like chemical substances in blood or urine, some of these vapors can provide valuable information regarding the state of the human body. A highly sensitive acetone biochemical gas sensor (bio-sniffer) was developed and used to measure exhaled breath acetone concentration, and assess lipid metabolism based on breath acetone analysis. A fiber-optic biochemical gas sensing system was constructed by attaching a flow-cell with nicotinamide adenine dinucleotide (NADH)-dependent secondary alcohol dehydrogenase (S-ADH) immobilized membrane onto a fiber-optic NADH measurement system. The NADH measurement system utilizes an ultraviolet-light emitting diode with peak emission of 335 nm as an excitation light source. NADH is consumed by the enzymatic reaction of S-ADH, and the consumption is proportional to the concentration of acetone vapor. Phosphate buffer which contained NADH was circulated into the flow-cell to rinse products and the excessive substrates from the optode. The change of fluorescent emitted from NADH is analyzed by the PMT. Hence, fluorescence intensity decreased as the acetone concentration increased. The relationship between fluorescence intensity and acetone concentration was identified from 20 ppb to 5300 ppb. This interval included the concentration of acetone vapor in the breath of healthy people and those suffering from disorders of carbohydrate metabolism. Finally, the acetone bio-sniffer was used to measure breath acetone during an exercise stress test on an ergometer after a period of fasting. The concentration of acetone in breath was shown to significantly increase after exercise. This biosensor allows rapid, highly sensitive and selective measurement of lipid metabolism.


Biosensors and Bioelectronics | 2015

Chemiluminescent imaging of transpired ethanol from the palm for evaluation of alcohol metabolism.

Takahiro Arakawa; Kazutaka Kita; Xin Wang; Koji Toma; Kohji Mitsubayashi

A 2-dimensional imaging system was constructed and applied in measurements of gaseous ethanol emissions from the human palm. This imaging system measures gaseous ethanol concentrations as intensities of chemiluminescence by luminol reaction induced by alcohol oxidase and luminol-hydrogen peroxide-horseradish peroxidase system. Conversions of ethanol distributions and concentrations to 2-dimensional chemiluminescence were conducted on an enzyme-immobilized mesh substrate in a dark box, which contained a luminol solution. In order to visualize ethanol emissions from human palm skin, we developed highly sensitive and selective imaging system for transpired gaseous ethanol at sub ppm-levels. Thus, a mixture of a high-purity luminol solution of luminol sodium salt HG solution instead of standard luminol solution and an enhancer of eosin Y solution was adapted to refine the chemiluminescent intensity of the imaging system, and improved the detection limit to 3 ppm gaseous ethanol. The highly sensitive imaging allows us to successfully visualize the emissions dynamics of transdermal gaseous ethanol. The intensity of each site on the palm shows the reflection of ethanol concentrations distributions corresponding to the amount of alcohol metabolized upon consumption. This imaging system is significant and useful for the assessment of ethanol measurement of the palmar skin.


Analytical Chemistry | 2015

Repetitive Immunoassay with a Surface Acoustic Wave Device and a Highly Stable Protein Monolayer for On-Site Monitoring of Airborne Dust Mite Allergens

Koji Toma; Daisuke Miki; Chisato Kishikawa; Naoyuki Yoshimura; Takahiro Arakawa; Hiromi Yatsuda; Kohji Mitsubayashi

This work describes a sensor to be incorporated into the on-site monitoring system of airborne house dust mite (HDM) allergens. A surface acoustic wave (SAW) device was combined with self-assembled monolayers of a highly stable antibody capture protein on the SAW surface that have high resistance to pH change. A sandwich assay was used to measure a HDM allergen, Der f 1 derived from Dermatophagoides farinae. Capture antibodies were cross-linked to a protein G based capture layer (ORLA85) on the sensor surface, thereby only Der f 1 and detection antibodies were regenerated by changing pH, resulting in fast repetition of the measurement. The sensor was characterized through 10 repetitive measurements of Der f 1, which demonstrated high reproducibility of the sensor with the coefficient of variation of 5.6%. The limit of detection (LOD) of the sensor was 6.1 ng·mL(-1), encompassing the standard (20 ng·mL(-1)) set by the World Health Organization. Negligible sensor outputs were observed for five different major allergens including other HDM allergens which tend to have cross-reactivity to Der f 1 and their mixtures with Der f 1. Finally, the sensor lifetime was evaluated by conducting three measurements per day, and the sensor output did not substantially change for 4 days. These characteristics make the SAW immunosensor a promising candidate for incorporation into on-site allergen monitoring systems.


Biosensors and Bioelectronics | 2017

Bio-sniffer (gas-phase biosensor) with secondary alcohol dehydrogenase (S-ADH) for determination of isopropanol in exhaled air as a potential volatile biomarker

Po-Jen Chien; Takuma Suzuki; Masato Tsujii; Ming Ye; Koji Toma; Takahiro Arakawa; Kohji Mitsubayashi

Exhaled breath analysis has attracted lots of researchers attention in the past decades due to its advantages such as its non-invasive property and the possibility of continuous monitoring. In addition, several volatile organic compounds in breath have been identified as biomarkers for some diseases. Particularly, studies have pointed out that concentration of isopropanol (IPA) in exhaled air might relate with certain illnesses such as liver disease, chronic obstructive pulmonary (COPD), and lung cancer. In this study, a highly sensitive and selective biochemical gas sensor (bio-sniffer) for the breath IPA concentration determination was constructed and optimized. This bio-sniffer measures the concentration of IPA according to the fluorescence intensity of oxidized nicotinamide adenine dinucleotide (NADH), which was produced by an enzymatic reaction of secondary alcohol dehydrogenase (S-ADH). The NADH detection system employed an UV-LED as the excitation light, and a highly sensitive photomultiplier tube (PMT) as a fluorescence intensity detector. A gas-sensing region was developed using an optical fiber probe equipped with a flow-cell and enzyme immobilized membrane, and connected to the NADH measurement system. The calibration range of the IPA bio-sniffer was confirmed from 1ppb to 9060ppb that was comparable to other IPA analysis methods. The results of the analysis of breath IPA concentration in healthy subjects using the bio-sniffer showed a mean concentration of 16.0ppb, which was similar to other studies. These results have demonstrated that this highly sensitive and selective bio-sniffer could be used to measure the IPA in exhaled air, and it is expected to apply for breath IPA research and investigation of biomarkers for clinical diagnosis.


Biosensors and Bioelectronics | 2015

Glucose-driven chemo-mechanical autonomous drug-release system with multi-enzymatic amplification toward feedback control of blood glucose in diabetes

Munkhbayar Munkhjargal; Kohdai Hatayama; Yuki Matsuura; Koji Toma; Takahiro Arakawa; Kohji Mitsubayashi

A second-generation novel chemo-mechanical autonomous drug release system, incorporating various improvements over our first-generation system, was fabricated and evaluated. Enhanced oxygen uptake by the enzyme membrane of the organic engine was facilitated by optimizing the quantity of enzyme immobilizer, PVA-SbQ, and by hydrophobizing the membrane surface. Various quantities of PVA-SbQ were evaluated in the organic engine by measuring the decompression rate, with 1.5 mg/cm(2) yielding optimum results. When fluororesin was used as a hydrophobizing coating, the time to reach the peak decompression rate was shortened 2.3-fold. The optimized elements of the system were evaluated as a unit, first in an open loop and then in a closed loop setting, using a mixture of glucose solution (25 mmol/L), ATP and MgCI2 with glucose hexokinase enzyme (HK) as a glucose reducer. In conclusion, feedback-control of physiologically relevant glucose concentration was demonstrated by the second-generation drug release system without any requirement for external energy.


Analytical Chemistry | 2017

Biochemical Gas Sensors (Biosniffers) Using Forward and Reverse Reactions of Secondary Alcohol Dehydrogenase for Breath Isopropanol and Acetone as Potential Volatile Biomarkers of Diabetes Mellitus

Po Jen Chien; Takuma Suzuki; Masato Tsujii; Ming Ye; Isao Minami; Kanako Toda; Hiromi Otsuka; Koji Toma; Takahiro Arakawa; Kouji Araki; Kayoko Shinada; Yoshihiro Ogawa; Kohji Mitsubayashi

This study describes two biosniffers to determine breath acetone and isopropanol (IPA) levels and applies them for breath measurement in healthy subjects and diabetic patients. Secondary alcohol dehydrogenase (S-ADH) can reduce acetone and oxidize nicotinamide adenine dinucleotide (NADH to NAD+) in a weak acid environment. NADH can be excited by 340 nm excitation lights and subsequently emit 490 nm fluorescence. Therefore, acetone can be measured by the decrease in NADH fluorescence intensity. S-ADH can also oxidize IPA and reduce NAD+ to NADH when it is in an alkaline environment. Thus, IPA can be detected by the increase of fluorescence. The developed biosniffers show rapid response, high sensitivity and high selectivity. The breath acetone and IPA analysis in healthy subjects shows that the mean values were 750.0 ± 434.4 ppb and 15.4 ± 11.3 ppb. Both acetone and IPA did not show a statistical difference among different genders and ages. The breath acetone analysis for diabetic patients shows a mean value of 1207.7 ± 689.5 ppb, which was higher than that of healthy subjects (p < 1 × 10-6). In particularly, type-1 diabetic (T1D) patients exhaled a much higher concentration of acetone than type-2 diabetic (T2D) patients (p < 0.01). The breath IPA also had a higher concentration in diabetic patients (23.1 ± 20.1 ppb, p < 0.01), but only T2D patients presented a statistical difference (23.9 ± 21.3 ppb, p < 0.01). These findings are worthwhile in the study of breath biomarkers for diabetes mellitus diagnosis. Additionally, the developed biosniffers provide a new technique for volatolomics research.


Talanta | 2016

Optical isopropanol biosensor using NADH-dependent secondary alcohol dehydrogenase (S-ADH)

Po-Jen Chien; Ming Ye; Takuma Suzuki; Koji Toma; Takahiro Arakawa; Kohji Mitsubayashi

Isopropanol (IPA) is an important solvent used in industrial activity often found in hospitals as antiseptic alcohol rub. Also, IPA may have the potential to be a biomarker of diabetic ketoacidosis. In this study, an optical biosensor using NADH-dependent secondary alcohol dehydrogenase (S-ADH) for IPA measurement was constructed and evaluated. An ultraviolet light emitting diode (UV-LED, λ=340nm) was employed as the excitation light to excite nicotinamide adenine dinucleotide (NADH). A photomultiplier tube (PMT) was connected to a two-way branch optical fiber for measuring the fluorescence emitted from the NADH. S-ADH was immobilized on the membrane to catalyze IPA to acetone and reduce NAD(+) to be NADH. This IPA biosensor shows highly sensitivity and selectivity, the calibration range is from 500 nmol L(-1) to 1mmolL(-1). The optimization of buffer pH, temperature, and the enzyme-immobilized method were also evaluated. The detection of IPA in nail related cosmetic using our IPA biosensor was also carried out. The results showed that large amounts of IPA were used in these kinds of cosmetics. This IPA biosensor comes with the advantages of rapid reaction, good reproducibility, and wide dynamic range, and is also expected to use for clinical IPA detections in serum or other medical and health related applications.


Biosensors and Bioelectronics | 2018

Air bio-battery with a gas/liquid porous diaphragm cell for medical and health care devices

Takahiro Arakawa; Rui Xie; Fumiya Seshima; Koji Toma; Kohji Mitsubayashi

Powering future generations of medical and health care devices mandates the transcutaneous transfer of energy or harvesting energy from the human body fluid. Glucose-driven bio fuel cells (bio-batteries) demonstrate promise as they produce electrical energy from glucose, which is a substrate presents in physiological fluids. Enzymatic biofuel cells can convert chemical energy into electrical energy using enzymes as catalysts. In this study, an air bio-battery was developed for healthcare and medical applications, consisting of a glucose-driven enzymatic biofuel cell using a direct gas-permeable membrane or a gas/liquid porous diaphragm. The power generation characteristics included a maximum current density of 285μA/cm2 and maximum power density of 70.7μW/cm2 in the presence of 5mmol/L of glucose in solution. In addition, high-performance, long-term-stabilized power generation was achieved using the gas/liquid porous diaphragm for the reactions between oxygen and enzyme. This system can be powered using 5mmol/L of glucose, the value of which is similar to that of the blood sugar range in humans.


Analytical Chemistry | 2018

Fluorometric sniff-cam (gas-imaging system) utilizing alcohol dehydrogenase for imaging concentration distribution of acetaldehyde in breath and transdermal vapor after drinking

Kenta Iitani; Toshiyuki Sato; Munire Naisierding; Yuuki Hayakawa; Koji Toma; Takahiro Arakawa; Kohji Mitsubayashi

Understanding concentration distributions, release sites, and release dynamics of volatile organic compounds (VOCs) from the human is expected to lead to methods for noninvasive disease screening and assessment of metabolisms. In this study, we developed a visualization system (sniff-cam) that enabled one to identify a spatiotemporal change of gaseous acetaldehyde (AcH) in real-time. AcH sniff-cam was composed of a camera, a UV-LED array sheet, and an alcohol dehydrogenase (ADH)-immobilized mesh. A reverse reaction of ADH was employed for detection of gaseous AcH where a relationship between fluorescence intensity from nicotinamide adenine dinucleotide and the concentration of AcH was inversely proportional; thus, the concentration distribution of AcH was measured by detecting the fluorescence decrease. Moreover, the image differentiation method that calculated a fluorescence change rate was employed to visualize a real-time change in the concentration distribution of AcH. The dynamic range of the sniff-cam was 0.1-10 ppm which encompassed breath AcH concentrations after drinking. Finally, the sniff-cam achieved the visualization of the concentration distribution of AcH in breath and skin gas. A clear difference of breath AcH concentration was observed between aldehyde dehydrogenase type 2 active and inactive subjects, which was attributed to metabolic capacities of AcH. AcH in skin gas showed a similar time course of AcH concentration to the breath and a variety of release concentration distribution. Using different NADH-dependent dehydrogenases in the sniff-cam could lead to a versatile method for noninvasive disease screening by acquiring spatiotemporal information on various VOCs in breath or skin gas.


ACS Sensors | 2017

Improved Sensitivity of Acetaldehyde Biosensor by Detecting ADH Reverse Reaction-Mediated NADH Fluoro-Quenching for Wine Evaluation

Kenta Iitani; Po-Jen Chien; Takuma Suzuki; Koji Toma; Takahiro Arakawa; Kohji Mitsubayashi

Acetaldehyde (AcH) is found in ambient air, foods, and the living body. This toxic substance is also contained in wine and known as an important ingredient affecting the quality of wine. Herein, we constructed and evaluated two different fiber-optic biosensors for measurement of AcH in the liquid phase (AcH biosensor) using aldehyde dehydrogenase (ALDH) or alcohol dehydrogenase (ADH). The AcH biosensor measured a concentration of AcH using fluorescence intensity of a reduced form of nicotinamide adenine dinucleotide (NADH) that was produced or consumed via catalytic reaction of the respective enzyme. In the AcH measurement system, an ultraviolet light emitting diode (UV-LED) and photomultiplier tube (PMT) were connected to a bifurcated optical fiber and were used to excite and detect NADH. A sensing region was developed using an optical fiber probe and an enzyme-immobilized membrane, buffer pH, and concentrations of a coenzyme in buffer solution for ALDH forward reaction and ADH reverse reaction were optimized, and the dynamic ranges were compared. ADH-mediated AcH biosensor showed higher sensitivity, wider dynamic range (1-500 μM), and capability of rapid measurement (less than 3 min) than ALDH-mediated AcH biosensor (5-200 μM). ADH biosensor also presented a high selectivity and allowed measurement of AcH in 9 different wine samples (5 red and 4 white wines). The determined concentrations were comparable to those measured by NADH absorbance method, which validated the accuracy of the ADH biosensor in AcH measurement.

Collaboration


Dive into the Koji Toma's collaboration.

Top Co-Authors

Avatar

Takahiro Arakawa

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Kohji Mitsubayashi

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Kenta Iitani

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Po-Jen Chien

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Takuma Suzuki

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Ming Ye

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Shuhei Takeuchi

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Shunsuke Minakuchi

Tokyo Medical and Dental University

View shared research outputs
Researchain Logo
Decentralizing Knowledge