Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kristine M. Fischenich is active.

Publication


Featured researches published by Kristine M. Fischenich.


Journal of Biomechanics | 2015

Chronic changes in the articular cartilage and meniscus following traumatic impact to the lapine knee

Kristine M. Fischenich; Keith D. Button; Garrett A. Coatney; Ryan S. Fajardo; Kevin M. Leikert; Roger C. Haut; Tammy L. Haut Donahue

The objective of this study was to induce anterior cruciate ligament (ACL) and meniscal damage, via a single tibiofemoral compressive impact, in order to document articular cartilage and meniscal changes post-impact. Tibiofemoral joints of Flemish Giant rabbits were subjected to a single blunt impact that ruptured the ACL and produced acute meniscal damage. Animals were allowed unrestricted cage activity for 12 weeks before euthanasia. India ink analysis of the articular cartilage revealed higher degrees of surface damage on the impacted tibias (p=0.018) and femurs (p<0.0001) compared to controls. Chronic meniscal damage was most prevalent in the medial central and medial posterior regions. Mechanical tests revealed an overall 19.4% increase in tibial plateau cartilage thickness (p=0.026), 34.8% increase in tibial plateau permeability (p=0.054), 40.8% increase in femoral condyle permeability (p=0.029), and 20.1% decrease in femoral condyle matrix modulus (p=0.012) in impacted joints compared to controls. Both instantaneous and equilibrium moduli of the lateral and medial menisci were decreased compared to control (p<0.02). Histological analyses revealed significantly increased presence of fissures in the medial femur (p=0.036). In both meniscus and cartilage there was a significant decrease in GAG coverage for the impacted limbs. Based on these results it is clear that an unattended combined meniscal and ACL injury results in significant changes to the soft tissues in this experimental joint 12 weeks post-injury. Such changes are consistent with a clinical description of mid to late stage PTOA of the knee.


Journal of Biomechanics | 2015

An optimized transversely isotropic, hyper-poro-viscoelastic finite element model of the meniscus to evaluate mechanical degradation following traumatic loading

Benjamin B. Wheatley; Kristine M. Fischenich; Keith D. Button; Roger C. Haut; Tammy L. Haut Donahue

Inverse finite element (FE) analysis is an effective method to predict material behavior, evaluate mechanical properties, and study differences in biological tissue function. The meniscus plays a key role in load distribution within the knee joint and meniscal degradation is commonly associated with the onset of osteoarthritis. In the current study, a novel transversely isotropic hyper-poro-viscoelastic constitutive formulation was incorporated in a FE model to evaluate changes in meniscal material properties following tibiofemoral joint impact. A non-linear optimization scheme was used to fit the model output to indentation relaxation experimental data. This study is the first to investigate rate of relaxation in healthy versus impacted menisci. Stiffness was found to be decreased (p=0.003), while the rate of tissue relaxation increased (p=0.010) at twelve weeks post impact. Total amount of relaxation, however, did not change in the impacted tissue (p=0.513).


Journal of Biomechanical Engineering-transactions of The Asme | 2014

Evaluation of Meniscal Mechanics and Proteoglycan Content in a Modified Anterior Cruciate Ligament Transection Model

Kristine M. Fischenich; Garrett A. Coatney; John H. Haverkamp; Keith D. Button; C. E. DeCamp; Roger C. Haut; Tammy L. Haut Donahue

Post-traumatic osteoarthritis (PTOA) develops as a result of traumatic loading that causes tears of the soft tissues in the knee. A modified transection model, where the anterior cruciate ligament (ACL) and both menisci were transected, was used on skeletally mature Flemish Giant rabbits. Gross morphological assessments, elastic moduli, and glycosaminoglycan (GAG) coverage of the menisci were determined to quantify the amount of tissue damage 12 weeks post injury. This study is one of the first to monitor meniscal changes after inducing combined meniscal and ACL transections. A decrease in elastic moduli as well as a decrease in GAG coverage was seen.


Journal of Biomechanics | 2015

Effects of degeneration on the compressive and tensile properties of human meniscus

Kristine M. Fischenich; Jackson T. Lewis; Kirk A. Kindsfater; Travis S. Bailey; Tammy L. Haut Donahue

Healthy menisci function within the joint to prevent the underlying articular cartilage from excessive loads. Understanding how mechanical properties of menisci change with degeneration can drive future therapeutic studies to prevent this degeneration. Thus, the goal of this study was to characterize both compressive and tensile moduli of human menisci with varying degrees of gross damage due to osteoarthritis (OA). Twenty four paired menisci were collected from total knee joint replacement patients and the menisci were graded on a scale from 0-4 according to level of gross meniscal degeneration with 0=normal and 4=full tissue maceration. Each meniscus was then sectioned into anterior and posterior regions and subjected to indentation relaxation tests. Samples were sliced into 1mm thick strips, made into dumbbells using a custom punch, and pulled to failure. Significant decreases in instantaneous compressive modulus were seen in the lateral posterior region between grades 0 and 1 (36% decrease) and in the medial anterior regions between grades 1 and 2 (67% decrease) and 1 and 3 (72% decrease). Changes in equilibrium modulus where seen in the lateral anterior region between grades 1 and 2 (35% decrease), lateral posterior region between grades 0-2 (41% decrease), and medial anterior regions between grades 1 and 2 (59% decrease), 1 and 3 (67% decrease), 2 and 4 (54% decrease), and 3 and 4 (42% decrease). No significant changes were observed in tensile modulus across all regions and degenerative grades. The results of this study demonstrate the compressive moduli are affected even in early stages of gross degeneration, and continue to decrease with increased deterioration. However, osteoarthritic menisci retain a tensile modulus similar to that of previously reported healthy menisci. This study highlights progressive changes in meniscal mechanical compressive integrity as level of gross tissue degradation increases, and thus, early interventions should focus on restoring or preserving compressive integrity.


Journal of The Mechanical Behavior of Biomedical Materials | 2018

Mechanical viability of a thermoplastic elastomer hydrogel as a soft tissue replacement material

Kristine M. Fischenich; Jackson T. Lewis; Travis S. Bailey; Tammy L. Haut Donahue

Hydrogels are a class of synthetic biomaterials composed of a polymer network that swells with water and as such they have both an elastic and viscous component making them ideal for soft tissue applications. This study characterizes the compressive, tensile, and shear properties of a thermoplastic elastomer (TPE) hydrogel and compares the results to published literature values for soft tissues such as articular cartilage, the knee meniscus, and intervertebral disc components. The results show the TPE hydrogel material is viscoelastic, strain rate dependent, has similar surface and bulk properties, displays minimal damping under dynamic load, and has tension-compression asymmetry. When compared to other soft tissues it has a comparable equilibrium compressive modulus of approximately 0.5MPa and shear modulus of 0.2MPa. With a tensile modulus of only 0.2MPa though, the TPE hydrogel is inferior in tension to most collagen based soft tissues. Additional steps may be necessary to reinforce the hydrogel system and increase tensile modulus depending on the desired soft tissue application. It can be concluded that this material could be a viable option for soft tissue replacements.


Journal of Biomedical Materials Research Part A | 2017

Dynamic compression of human and ovine meniscal tissue compared with a potential thermoplastic elastomer hydrogel replacement: DYNAMIC COMPRESSION OF HUMAN AND OVINE MENISCAL TISSUE

Kristine M. Fischenich; Katie Boncella; Jackson T. Lewis; Travis S. Bailey; Tammy L. Haut Donahue

Understanding how human meniscal tissue responds to loading regimes mimetic of daily life as well as how it compares to larger animal models is critical in the development of a functionally accurate synthetic surrogate. Seven human and eight ovine cadaveric meniscal specimens were regionally sectioned into cylinders 5 mm in diameter and 3 mm thick along with 10 polystyrene-b-polyethylene oxide block copolymer-based thermoplastic elastomer (TPE) hydrogels. Samples were compressed to 12% strain at 1 Hz for 5000 cycles, unloaded for 24 h, and then retested. No differences were found within each group between test one and test two. Human and ovine tissue exhibited no regional dependency (p < 0.05). Human samples relaxed quicker than ovine tissue or the TPE hydrogel with modulus values at cycle 50 not significantly different from cycle 5000. Ovine menisci were found to be similar to human menisci in relaxation profile but had significantly higher modulus values (3.44 MPa instantaneous and 0.61 MPa after 5000 cycles compared with 1.97 and 0.11 MPa found for human tissue) and significantly different power law fit coefficients. The TPE hydrogel had an initial modulus of 0.58 MPa and experienced less than a 20% total relaxation over the 5000. Significant differences in the magnitude of compressive modulus between human and ovine menisci were observed, however the relaxation profiles were similar. Although statistically different than the native tissues, modulus values of the TPE hydrogel material were similar to those of the human and ovine menisci, making it a material worth further investigation for use as a synthetic replacement.


Journal of The Mechanical Behavior of Biomedical Materials | 2015

Efficacy of P188 on lapine meniscus preservation following blunt trauma

Garrett A. Coatney; Adam C. Abraham; Kristine M. Fischenich; Keith D. Button; Roger C. Haut; Tammy L. Haut Donahue

Traumatic injury to the knee leads to the development of post-traumatic osteoarthritis. The objective of this study was to characterize the effects of a single intra-articular injection of a non-ionic surfactant, Poloxamer 188 (P188), in preservation of meniscal tissue following trauma through maintenance of meniscal glycosaminoglycan (GAG) content and mechanical properties. Flemish Giant rabbits were subjected to a closed knee joint, traumatic compressive impact with the joint constrained to prevent anterior tibial translation. The contralateral limb served as an un-impacted control. Six animals (treated) received an injection of P188 in phosphate buffered saline (PBS) post trauma, and another six animals (sham) received a single injection of PBS to the impacted limb. Histological analyses for GAG was determined 6 weeks post trauma, and functional outcomes were assessed using stress relaxation micro-indentation. The impacted limbs of the sham group demonstrated a significant decrease in meniscal GAG coverage compared to non-impacted limbs (p<0.05). GAG coverage of the impacted P188 treated limbs was not significantly different than contralateral non-impacted limbs in all regions except the medial anterior (p<0.05). No significant changes were documented in mechanics for either the sham or treated groups compared to their respective control limbs. This suggests that a single intra-articular injection of P188 shows promise in prevention of trauma induced GAG loss.


Journal of Orthopaedic Research | 2017

Comparison of two models of post‐traumatic osteoarthritis; Temporal degradation of articular cartilage and menisci

Kristine M. Fischenich; Keith D. Button; C. E. DeCamp; Roger C. Haut; Tammy L. Haut Donahue

The objective of this study was to compare longitudinal results from two models of combined anterior cruciate ligament (ACL) and meniscal injury. A modified ACL transection (mACLT) model and a traumatic impact (ACLF) model were used to create an ACL rupture and acute meniscal damage in a Flemish Giant animal model. The animals were euthanized at time points of 4, 8, or 12 weeks. The menisci were assessed for equilibrium and instantaneous compressive modulus, as well as glycosaminoglycan (GAG) coverage. The articular cartilage was mechanically assessed for thickness, matrix modulus, fiber modulus, and permeability. Articular cartilage GAG coverage, fissuring, tidemark integrity, and subchondral bone thickness were measured. Both models resulted in damage indicative of osteoarthritis, including decreased meniscal mechanics and GAG coverage, increased permeability and fissuring of articular cartilage, and decreased GAG coverage. The mACLT model had an early and lasting effect on the menisci mechanics and GAG coverage, while cartilage damage was not significantly affected until 12 weeks. The ACLF model resulted in an earlier change of articular cartilage GAG coverage and fissuring in both the 8 and 12 week groups. The menisci were only significantly affected at the 12 week time point in the ACLF model. We concluded the progression of post traumatic osteoarthritis was dependent on injury modality: a point to be considered in future investigations.


Disability and Rehabilitation: Assistive Technology | 2018

Epidemiological study of failures of the Jaipur Foot

Ian Huber; Kristine M. Fischenich; Jakob Wolynski; Brent Niese; Rachel Teater; Harlal Singh Mali; Anil Jain; Sheryl A. Sorby; Lisa M. Abrams; Tammy L. Haut Donahue

Abstract Objective: The purpose of this study was to examine effects of usage and demographics on damage to the Jaipur Foot prosthesis as well as the epidemiology and etiology of amputations performed at Santokba Durlabjhi Memorial Hospital (SDMH) in Jaipur, India. Design: Total time spent standing, total time spent wearing and total distance walked were compared against severity and location of damage to the prosthesis. Time between initial fitting and follow-up visit for damaged prosthetic was also considered in this analysis. A novel damage severity scale based on prosthesis functionality is presented along with a damage location legend. Results: Patients from 10 different states and two territories throughout India were included in the study. No main effects were found to be statistically significant in predicting severity or location of damage. Only the interaction between a patient’s total time spent standing and their total time spent wearing the prosthesis as well as the interaction between a patient’s total time spent standing and total distance walked was significant in predicting location of damage to the Jaipur Foot (p = .0327, p = .0278, respectively). Conclusions: The lack of significant usage factor effect on damage severity or location could support previous findings that lack standardization in materials and manufacturing processes, which is the major drawback of the Jaipur Foot. Implications for Rehabilitation The Jaipur Foot is a safe, reliable and stable product as no abrupt breakage or sudden falls causing injury to the patient were noted. Hence, it is a safe rehabilitation device for lost limbs. The population can squat and sit cross-legged while wearing the prosthetic foot and it does not affect damage severity or location of damage, allowing for these activities to be performed while rehabilitating. The manufacturing of the foot needs to be standardized to improve life of foot. Total time spent standing, total time spent wearing and total distance walked were not predictive of severity or location of damage to the prosthesis, hence providing patient guidelines for activity during rehabilitation.


Osteoarthritis and Cartilage | 2017

A study of acute and chronic tissue changes in surgical and traumatically-induced experimental models of knee joint injury using magnetic resonance imaging and micro-computed tomography

Kristine M. Fischenich; Hannah M. Pauly; Keith D. Button; Ryan S. Fajardo; C. E. DeCamp; Roger C. Haut; T.L. Haut Donahue

OBJECTIVE The objective of this study was to monitor the progression of joint damage in two animal models of knee joint trauma using two non-invasive, clinically available imaging modalities. METHODS A 3-T clinical magnet and micro-computed tomography (μCT) was used to document changes immediately following injury (acute) and post-injury (chronic) at time points of 4, 8, or 12 weeks. Joint damage was recorded at dissection and compared to the chronic magnetic resonance imaging (MRI) record. Fifteen Flemish Giant rabbits were subjected to a single tibiofemoral compressive impact (ACLF), and 18 underwent a combination of anterior cruciate ligament (ACL) and meniscal transection (mACLT). RESULTS All ACLF animals experienced ACL rupture, and 13 also experienced acute meniscal damage. All ACLF and mACLT animals showed meniscal and articular cartilage damages at dissection. Meniscal damage was documented as early as 4 weeks and worsened in 87% of the ACLF animals and 71% of the mACLT animals. Acute cartilage damage also developed further and increased in occurrence with time in both models. A progressive decrease in bone quantity and quality was documented in both models. The MRI data closely aligned with dissection notes suggesting this clinical tool may be a non-invasive method for documenting joint damage in lapine models of knee joint trauma. CONCLUSIONS The study investigates the acute to chronic progression of meniscal and cartilage damage at various time points, and chronic changes to the underlying bone in two models of posttraumatic osteoarthritis (PTOA), and highlights the dependency of the model on the location, type, and progression of damage over time.

Collaboration


Dive into the Kristine M. Fischenich's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Keith D. Button

Michigan State University

View shared research outputs
Top Co-Authors

Avatar

Roger C. Haut

Michigan State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

C. E. DeCamp

Michigan State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ryan S. Fajardo

Michigan State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Chen Guo

Colorado State University

View shared research outputs
Researchain Logo
Decentralizing Knowledge