Krzysztof Rokosz
Koszalin University of Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Krzysztof Rokosz.
Transactions of The Institute of Metal Finishing | 2007
Tadeusz Hryniewicz; Ryszard Rokicki; Krzysztof Rokosz
Abstract This paper aims to present the preliminary results of magnetoelectropolishing, a process derived and named by application of an external magnetic field coupled with the process being controlled and maintained under oxygen evolution to achieve an electropolished surface of a workpiece. The obtained surfaces exhibit reduced microroughness, better surface wetting resulting from increased surface energy, reduced and more uniform corrosion resistance, minimisation of external surface soiling and improved cleanability. The externally applied magnetic force for use with the enhanced electropolishing process may be selected from a group consisting of either permanent magnetic or electromagnetic devices. It has been shown that the enhanced electropolishing process results in better surface performance. In the present paper, for comparison purposes, results of surface roughness, hydrophilicity and corrosion behaviour are presented. Further studies, concerning the corrosion characteristics, the morphology and surface film chemistry, are in progress.
Materials | 2009
Tadeusz Hryniewicz; Krzysztof Rokosz; Massimiliano Filippi
The polarisation characteristics of the electropolishing process in a magnetic field (MEP – magnetoelectropolishing), in comparison with those obtained under standard/conventional process (EP) conditions, have been obtained. The occurrence of an EP plateau has been observed in view of the optimization of MEP process. Up-to-date stainless steel surface studies always indicated some amount of free-metal atoms apart from the detected oxides and hydroxides. Such a morphology of the surface film usually affects the thermodynamic stability and corrosion resistance of surface oxide layer and is one of the most important features of stainless steels. With this new MEP process we can improve metal surface properties by making the stainless steel more resistant to halides encountered in a variety of environments. Furthermore, in this paper the stainless steel surface film study results have been presented. The results of the corrosion research carried out by the authors on the behaviour of the most commonly used material − medical grade AISI 316L stainless steel both in Ringer’s body fluid and in aqueous 3% NaCl solution have been investigated and presented earlier elsewhere, though some of these results, concerning the EIS Nyquist plots and polarization curves are also revealed herein. In this paper an attempt to explain this peculiar performance of 316L stainless steel has been undertaken. The SEM studies, Auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS) were performed on 316L samples after three treatments: MP – abrasive polishing (800 grit size), EP – conventional electrolytic polishing, and MEP – magnetoelectropolishing. It has been found that the proposed magnetoelectropolishing (MEP) process considerably modifies the morphology and the composition of the surface film, thus leading to improved corrosion resistance of the studied 316L SS.
Materials | 2015
Tadeusz Hryniewicz; Krzysztof Rokosz; Ryszard Rokicki; Frédéric Prima
This work presents the nanoindentation and XPS results of a newly-developed biomaterial of titanium TNZ alloy after different surface treatments. The investigations were performed on the samples AR (as received), EP (after a standard electropolishing) and MEP (after magnetoelectropolishing). The electropolishing processes, both EP and MEP, were conducted in the same proprietary electrolyte based on concentrated sulfuric acid. The mechanical properties of the titanium TNZ alloy biomaterial demonstrated an evident dependence on the surface treatment method, with MEP samples revealing extremely different behavior and mechanical properties. The reason for that different behavior appeared to be influenced by the surface film composition, as revealed by XPS study results displayed in this work. The increase of niobium and zirconium in the surface film of the same titanium TNZ alloy after magnetoelectropolishing MEP treatment is meaningful and especially advantageous considering the application of this alloy as a biomaterial.
Measurement Science Review | 2013
Milena Kušnerová; Jan Valíček; Marta Harničárová; Tadeusz Hryniewicz; Krzysztof Rokosz; Zuzana Palkova; Vojtěch Václavík; Michal Řepka; Miroslava Bendová
Abstract The paper deals with the innovative ways of nonstandard, simplifying applications of the valid method for evaluating uncertainties in measurement results and with the definition of conditions of their usability. The evaluation of a substitute criterion for measurement accuracy by means of a relative difference between the measurand and its reference value is proposed. This nonstandard relative uncertainty is comparable with the overall relative standard uncertainty in the measurement result, and thus the evaluation of it enables other simplifications in the calculations of measurement result uncertainties. The use of the simplified evaluation of measurement results is illustrated in two experiments in measurement of the coefficient of thermal conductivity of an insulating material newly developed for the needs of building practice, namely measurement using commercial instruments, and measurement using a newly developed original measuring instrument.
International Journal of Materials Research | 2013
Krzysztof Rokosz; Tadeusz Hryniewicz
Abstract The work presents the X-ray photoelectron spectroscopy measurement results of LDX 2101 duplex steel surface after magnetoelectropolishing in comparison with the results obtained after a standard electropolishing in still electrolyte and in the electrolyte with moderate mixing. A considerable improvement of the steel surface was found to appear after the magnetoelectropolishing treatment concerning the general composition. The calculated ratio of chromium compounds to iron compounds Cr-X/FeX equals 2 after magnetoelectropolishing and only 0.5 after a standard electropolishing. On the other hand, the ionic Cr6+ content after magnetoelectropolishing was the lowest (2.77 at.%), and after a standard electropolishing it was the highest (30.3 at.%). Such results are expected to influence the corrosion behavior of the steel and increase the corrosion resistance greatly.
Measurement Science Review | 2012
Jan Valíček; Milan Držík; Tadeusz Hryniewicz; Marta Harničárová; Krzysztof Rokosz; Milena Kušnerová; Karla Barčová; David Bražina
Abstract The paper deals with the measurement and identification of surfaces after machining in a non-contact manner. It presents a new modified measurement method and its implementation, the results of intensity distribution in the defocusing plane, their analysis and interpretation. The scanned intensity distribution at the defocusing plane gives information necessary to assess the second derivatives, and thus, surface functions which can be used to determine groove curvatures of the real surface morphology. The proposed method of measurement has proved to be very sensitive in evaluating the differences between surface finishing methods by which the measured surface standards (etalons) were machined. Two methods of machining were chosen: face grinding and planning. By comparing the roughness standard values Ra, there were obtained relationships between these values and the parameter of the characteristic frequency of vertical inequality being measured according to the presented method. A good correlation between the measured and surface standard values with the correlation coefficient taking a range of values from 0.8 to 1 was achieved.
Journal of Materials Engineering and Performance | 2015
Ryszard Rokicki; Tadeusz Hryniewicz; Chandan Pulletikurthi; Krzysztof Rokosz; Norman Munroe
Haemocompatibility of Nitinol implantable devices and their corrosion resistance as well as resistance to fracture are very important features of advanced medical implants. The authors of the paper present some novel methods capable to improve Nitinol implantable devices to some marked degree beyond currently used electropolishing (EP) processes. Instead, a magnetoelectropolishing process should be advised. The polarization study shows that magnetoelectropolished Nitinol surface is more corrosion resistant than that obtained after a standard EP and has a unique ability to repassivate the surface. Currently used sterilization processes of Nitinol implantable devices can dramatically change physicochemical properties of medical device and by this influence its biocompatibility. The Authors’ experimental results clearly show the way to improve biocompatibility of NiTi alloy surface. The final sodium hypochlorite treatment should replace currently used Nitinol implantable devices sterilization methods which rationale was also given in our previous study.
MRS Proceedings | 2009
Tadeusz Hryniewicz; Krzysztof Rokosz; Ryszard Rokicki
The purpose of the study was to reveal the effects of a new electropolishing process carried out under a constant magnetic field, termed as magnetoelectropolishing (MEP). In this work we investigated Nitinol rotary endodontic instruments by surface and morphology change after MEP. The MEP process greatly affects both surface also mechanical properties like the bending and fatigue resistance. The investigation covered surface interferometry measurements, X-ray Photoelectron Spectroscopy (XPS) studies, and Scanning Electron Microscopy (SEM) with EDAX studies referred to two groups of endodontic instruments: ready-to-use or as-received (AR) files, and magnetoelectropolished (MEP) instruments, in comparison with the instruments surface after a conventional electropolishing (EP). The treated surfaces of NiTi endodontic files were studied by interferometric method in view of getting multiple surface characteristics, together with digital data concerning the arithmetic mean height Sa and the maximum height of scale limited surface Sz. The investigation results obtained have indicated a considerable improvement of MEP surface in comparison with both AR and EP surfaces. Such a surface after MEP reveals several positive features, decreased roughness, elimination of metallic state (here Ni and Ti elements) in the surface film, much enriched with titanium oxides and diminished nickel oxides. The study results show that the contents of Ni compounds is higher after EP (18.3%) than after MEP (10.2%), whereas the contents of Ti compounds is higher after MEP (83.4%) than after EP (76.6%). The total Ti/Ni ratio indicates almost double surpass of titanium over nickel in the surface film after MEP in comparison with the total amount of that ratio after EP. The qualitative investigation of fatigue tests have indicated much better performance of NiTi endodontic file samples after MEP than those related to AR and/or after EP. We have proved that the magnetoelectropolishing process may further modify surface. The following studies are to be directed onto performance and specific mechanical properties of the endodontic files at work.
Materials Science Forum | 2016
Krzysztof Rokosz; Tadeusz Hryniewicz; Winfried Malorny
The main goal of present paper is to obtain porous coatings enriched in copper by Plasma Electrolytic Oxidation on titanium and niobium as well as on NiTi and Ti6Al4V alloys. Performed SEM and EDS studies confirmed the hypothesis that it is possible to create the porous surfaces with pores, which shapes and size are different. In order to show the copper enrichment inside the surface layers, the copper-to-phosphorus ratios were used. Based on these ratios it may be concluded that average value of Cu/P is maximal for NiTi alloy after oxidation in electrolyte containing 300 g of copper nitrate in 1 liter of phosphoric acid and equals 0.26. The minimum of Cu/P ratio equaling to 0.12 was recorded for pure titanium and pure niobium treated in electrolyte containing 300 g of Cu (NO3)2 in 1 L H3PO4.
Spectroscopy | 2016
Krzysztof Rokosz; Tadeusz Hryniewicz; Patrick Chapon; Steinar Raaen; Hugo Ricardo Zschommler Sandim
XPS and GDOES characterizations of porous coatings on tantalum after Plasma Electrolytic Oxidation (PEO) at 450 V for 3 minutes in electrolyte containing concentrated (85%) phosphoric acid with calcium nitrate and copper (II) nitrate are described. Based on the obtained data, it may be concluded that the PEO coating consists of tantalum (Ta5