Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kuniharu Takei is active.

Publication


Featured researches published by Kuniharu Takei.


ACS Nano | 2014

Fully Printed Flexible Fingerprint-like Three-Axis Tactile and Slip Force and Temperature Sensors for Artificial Skin

Shingo Harada; Kenichiro Kanao; Yuki Yamamoto; Takayuki Arie; Seiji Akita; Kuniharu Takei

A three-axis tactile force sensor that determines the touch and slip/friction force may advance artificial skin and robotic applications by fully imitating human skin. The ability to detect slip/friction and tactile forces simultaneously allows unknown objects to be held in robotic applications. However, the functionalities of flexible devices have been limited to a tactile force in one direction due to difficulties fabricating devices on flexible substrates. Here we demonstrate a fully printed fingerprint-like three-axis tactile force and temperature sensor for artificial skin applications. To achieve economic macroscale devices, these sensors are fabricated and integrated using only printing methods. Strain engineering enables the strain distribution to be detected upon applying a slip/friction force. By reading the strain difference at four integrated force sensors for a pixel, both the tactile and slip/friction forces can be analyzed simultaneously. As a proof of concept, the high sensitivity and selectivity for both force and temperature are demonstrated using a 3×3 array artificial skin that senses tactile, slip/friction, and temperature. Multifunctional sensing components for a flexible device are important advances for both practical applications and basic research in flexible electronics.


Advanced Healthcare Materials | 2015

Toward Flexible and Wearable Human‐Interactive Health‐Monitoring Devices

Kuniharu Takei; Wataru Honda; Shingo Harada; Takayuki Arie; Seiji Akita

This Progress Report introduces flexible wearable health-monitoring devices that interact with a person by detecting from and stimulating the body. Interactive health-monitoring devices should be highly flexible and attach to the body without awareness like a bandage. This type of wearable health-monitoring device will realize a new class of electronics, which will be applicable not only to health monitoring, but also to other electrical devices. However, to realize wearable health-monitoring devices, many obstacles must be overcome to economically form the active electrical components on a flexible substrate using macroscale fabrication processes. In particular, health-monitoring sensors and curing functions need to be integrated. Here recent developments and advancements toward flexible health-monitoring devices are presented, including conceptual designs of human-interactive devices.


Nano Letters | 2013

Carbon Nanotube Active-Matrix Backplanes for Mechanically Flexible Visible Light and X‑ray Imagers

Toshitake Takahashi; Zhibin Yu; Kevin P. Chen; Daisuke Kiriya; Chuan Wang; Kuniharu Takei; Hiroshi Shiraki; Teresa Chen; Biwu Ma; Ali Javey

We report visible light and X-ray imagers on lightweight and mechanically flexible plastic substrates. The process involves solution processing of organic photodetectors on top of an active-matrix backplane consisting of carbon nanotube thin-film transistors. The system takes advantage of the high mobility of nanotube transistors for low operating voltages and efficient light absorption of organic bulk-heterojunctions for high imaging sensitivity. With this highly scalable process scheme, 18 × 18 pixel-array flexible imagers (physical size of 2 cm × 1.5 cm) with high performance are successfully demonstrated. In addition, as the absorption peak of the adopted organic photodiodes covers the green band of the light spectrum, X-ray imaging is readily demonstrated by placing a scintillator film on top of the flexible imagers.


RSC Advances | 2015

Highly selective flexible tactile strain and temperature sensors against substrate bending for an artificial skin

Kenichiro Kanao; Shingo Harada; Yuki Yamamoto; Wataru Honda; Takayuki Arie; Seiji Akita; Kuniharu Takei

Flexible devices can conformally cover any surfaces and interact with different stimuli such as human touch. Although a flexible tactile sensor has been reported as an artificial skin application, distinguishing between a tactile force and strain due to substrate bending remains challenging. Here we report a highly selective tactile force sensor against bending on the basis of strain engineering by fabricating a cantilever structure. The proposed device achieves a 4–23 times improvement in selectivity compared to conventional pressure sensitive rubber. As a proof-of-concept for e-skin, an array composed of highly selective tactile force sensors and temperature sensors is successfully demonstrated to imitate human skin.


Science Advances | 2016

Printed multifunctional flexible device with an integrated motion sensor for health care monitoring

Yuki Yamamoto; Shingo Harada; Daisuke Yamamoto; Wataru Honda; Takayuki Arie; Seiji Akita; Kuniharu Takei

Printable, multifunctional, flexible, health monitoring detachable patch sheets with human motion detection capability. Real-time health care monitoring may enable prediction and prevention of disease or improve treatment by diagnosing illnesses in the early stages. Wearable, comfortable, sensing devices are required to allow continuous monitoring of a person’s health; other important considerations for this technology are device flexibility, low-cost components and processing, and multifunctionality. To address these criteria, we present a flexible, multifunctional printed health care sensor equipped with a three-axis acceleration sensor to monitor physical movement and motion. Because the device is designed to be attached directly onto the skin, it has a modular design with two detachable components: One device component is nondisposable, whereas the other one is disposable and designed to be worn in contact with the skin. The design of this disposable sensing sheet takes into account hygiene concerns and low-cost materials and fabrication methods as well as features integrated, printed sensors to monitor for temperature, acceleration, electrocardiograms, and a kirigami structure, which allows for stretching on skin. The reusable component of the device contains more expensive device components, features an ultraviolet light sensor that is controlled by carbon nanotube thin-film transistors, and has a mechanically flexible and stable liquid metal contact for connection to the disposable sensing sheet. After characterizing the electrical properties of the transistors and flexible sensors, we demonstrate a proof-of-concept device that is capable of health care monitoring combined with detection of physical activity, showing that this device provides an excellent platform for the development of commercially viable, wearable health care monitors.


Advanced Materials | 2015

High‐Performance, Mechanically Flexible, and Vertically Integrated 3D Carbon Nanotube and InGaZnO Complementary Circuits with a Temperature Sensor

Wataru Honda; Shingo Harada; Shohei Ishida; Takayuki Arie; Seiji Akita; Kuniharu Takei

A vertically integrated inorganic-based flexible complementary metal-oxide-semiconductor (CMOS) inverter with a temperature sensor with a high inverter gain of ≈50 and a low power consumption of <7 nW mm(-1) is demonstrated using a layer-by-layer assembly process. In addition, the negligible influence of the mechanical flexibility on the performance of the CMOS inverter and the temperature dependence of the CMOS inverter characteristics are discussed.


Scientific Reports | 2015

Mechanically Flexible and High-Performance CMOS Logic Circuits

Wataru Honda; Takayuki Arie; Seiji Akita; Kuniharu Takei

Low-power flexible logic circuits are key components required by the next generation of flexible electronic devices. For stable device operation, such components require a high degree of mechanical flexibility and reliability. Here, the mechanical properties of low-power flexible complementary metal–oxide–semiconductor (CMOS) logic circuits including inverter, NAND, and NOR are investigated. To fabricate CMOS circuits on flexible polyimide substrates, carbon nanotube (CNT) network films are used for p-type transistors, whereas amorphous InGaZnO films are used for the n-type transistors. The power consumption and voltage gain of CMOS inverters are <500 pW/mm at Vin = 0 V (<7.5 nW/mm at Vin = 5 V) and >45, respectively. Importantly, bending of the substrate is not found to cause significant changes in the device characteristics. This is also observed to be the case for more complex flexible NAND and NOR logic circuits for bending states with a curvature radius of 2.6 mm. The mechanical stability of these CMOS logic circuits makes them ideal candidates for use in flexible integrated devices.


Advanced Healthcare Materials | 2017

Efficient Skin Temperature Sensor and Stable Gel-Less Sticky ECG Sensor for a Wearable Flexible Healthcare Patch

Yuki Yamamoto; Daisuke Yamamoto; Makoto Takada; Hiroyoshi Naito; Takayuki Arie; Seiji Akita; Kuniharu Takei

Wearable, flexible healthcare devices, which can monitor health data to predict and diagnose disease in advance, benefit society. Toward this future, various flexible and stretchable sensors as well as other components are demonstrated by arranging materials, structures, and processes. Although there are many sensor demonstrations, the fundamental characteristics such as the dependence of a temperature sensor on film thickness and the impact of adhesive for an electrocardiogram (ECG) sensor are yet to be explored in detail. In this study, the effect of film thickness for skin temperature measurements, adhesive force, and reliability of gel-less ECG sensors as well as an integrated real-time demonstration is reported. Depending on the ambient conditions, film thickness strongly affects the precision of skin temperature measurements, resulting in a thin flexible film suitable for a temperature sensor in wearable device applications. Furthermore, by arranging the material composition, stable gel-less sticky ECG electrodes are realized. Finally, real-time simultaneous skin temperature and ECG signal recordings are demonstrated by attaching an optimized device onto a volunteers chest.


ACS Applied Materials & Interfaces | 2015

Air Ambient-Operated pNIPAM-Based Flexible Actuators Stimulated by Human Body Temperature and Sunlight

Yuki Yamamoto; Kenichiro Kanao; Takayuki Arie; Seiji Akita; Kuniharu Takei

Harnessing a natural power source such as the human body temperature or sunlight should realize ultimate low-power devices. In particular, macroscale and flexible actuators that do not require an artificial power source have tremendous potential. Here we propose and demonstrate electrically powerless polymer-based actuators operated at ambient conditions using a packaging technique in which the stimulating power source is produced by heat from the human body or sunlight. The actuating angle, force, and reliability are discussed as functions of temperature and exposure to sunlight. Furthermore, a wearable device platform and a smart curtain actuated by the temperature of human skin and sunlight, respectively, are demonstrated as the first proof-of-concepts. These nature-powered actuators should realize a new class of ultimate low-power devices.


Scientific Reports | 2016

Oscillation control of carbon nanotube mechanical resonator by electrostatic interaction induced retardation

Masaaki Yasuda; Kuniharu Takei; Takayuki Arie; Seiji Akita

Despite the superb intrinsic properties of carbon nanotube mechanical resonators, the quality factors at room temperature are 1,000 or less, even in vacuum, which is much lower than that of mechanical resonators fabricated using a top-down approach. This study demonstrates the improvement of the quality factor and the control of nonlinearity of the mechanical resonance of the cantilevered nanotube by electrostatic interaction. The apparent quality factor of the nanotube supported by insulator is improved drastically from approximately 630 to 3200 at room temperature. Results show that retardation of the electrostatic force induced by the contact resistance between the nanotube and the insulator support improves the quality factor. Finite element method calculation reveals that the nonuniform pileup charge on the insulator support strongly influences the nonlinearity of the resonance.

Collaboration


Dive into the Kuniharu Takei's collaboration.

Top Co-Authors

Avatar

Seiji Akita

Osaka Prefecture University

View shared research outputs
Top Co-Authors

Avatar

Takayuki Arie

Osaka Prefecture University

View shared research outputs
Top Co-Authors

Avatar

Shingo Harada

Osaka Prefecture University

View shared research outputs
Top Co-Authors

Avatar

Kenichiro Kanao

Osaka Prefecture University

View shared research outputs
Top Co-Authors

Avatar

Wataru Honda

Osaka Prefecture University

View shared research outputs
Top Co-Authors

Avatar

Yuki Yamamoto

Osaka Prefecture University

View shared research outputs
Top Co-Authors

Avatar

Shogo Nakata

Osaka Prefecture University

View shared research outputs
Top Co-Authors

Avatar

Yuki Anno

Osaka Prefecture University

View shared research outputs
Top Co-Authors

Avatar

Daisuke Yamamoto

Osaka Prefecture University

View shared research outputs
Top Co-Authors

Avatar

Masaaki Yasuda

Osaka Prefecture University

View shared research outputs
Researchain Logo
Decentralizing Knowledge