Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kyoung Hun Kim is active.

Publication


Featured researches published by Kyoung Hun Kim.


Materials Characterization | 2003

The effect of lanthanum on the fabrication of ZrB2–ZrC composites by spark plasma sintering

Kyoung Hun Kim; Kwang Bo Shim

The effect of the addition of the rare earth element, lanthanum, on the sintering characteristics of ZrB{sub 2}-ZrC composites has been analyzed during a spark plasma sintering (SPS) process. Microscopic observation confirmed that lanthanum accelerated mass transport by the formation of the liquid phase between the particles induced by the spark plasma in the initial stage of the SPS process, and then these were recrystallized to form a lanthanum-containing secondary phase at the grain boundaries and at the grain boundary triple junctions. In spite of the strong covalent bonding characteristics of the ZrB{sub 2}-ZrC composite there are many well-developed dislocation structures observed. The fracture toughness of the lanthanum-containing ZrB{sub 2}-ZrC is about 2.56 MPa m{sup 1/2}, which is comparable to that of the pure composite. Therefore, it is concluded that lanthanum is very effective as a sintering aid for the ZrB{sub 2}-ZrC composite without any degradation of the mechanical properties.


Korean Journal of Anesthesiology | 2012

Comparison of the Proseal LMA and intersurgical I-gel during gynecological laparoscopy

Woo Jae Jeon; Sang Yun Cho; Seong Jin Baek; Kyoung Hun Kim

Background The relatively recently developed I-gel (Intersurgical Ltd., Workingham, England) is a supraglottic airway device designed for single-use that, unlike conventional LMAs, does not require an inflatable cuff. In addition, the I-gel, much like the Proseal LMA (PLMA), has a gastric drainage tube associated with an upper tube for decompression of the stomach, thereby avoiding acid reflux and decreasing the risk of pulmonary absorption. The purpose of this study was to compare PLMA and I-gel devices in patients undergoing gynecological laparoscopy based on sealing pressure before and during pneumoperitoneum, insertion time, and gas exchange. Methods Following Institutional Review Board approval and written informed consent, 30 adult patients were randomly allocated to one of two groups (the PLMA or I-gel group). In each case, insertion time and number of attempts were recorded. After successful insertion, airway leak pressure was measured. Results Successful insertion and mechanical ventilation with both supraglottic airway devices was achieved on the first attempt in all 30 patients, and there were no significant differences with respect to insertion time. Likewise, leak pressure did not vary significantly either between or within groups after CO2 insufflation. In addition, differences between leak volume and leak fraction between groups were not significant. Conclusions The results of our study indicate that the I-gel is a reasonable alternative to the PLMA for controlled ventilation during laparoscopic gynecologic surgery.


Korean Journal of Anesthesiology | 2011

Ultrasound-guided greater occipital nerve block for patients with occipital headache and short term follow up

Jae Hang Shim; So Young Ko; Mi Rang Bang; Woo Jae Jeon; Sang Yun Cho; Jong Hoon Yeom; Woo Jong Shin; Kyoung Hun Kim; Jae-Chol Shim

Background The greater occipital nerve (GON) block has been frequently used for different types of headache, but performed with rough estimates of anatomic landmarks. Our study presents the values of the anatomic parameters and estimates the effectiveness of the ultrasound-guided GON blockade. Methods The GON was detected using ultrasound technique and distance from external occipital protuberance (EOP) to GON, from GON to occipital artery and depth from skin to GON was measured in volunteers. Patients with occipital headache were divided into two groups (ultrasound-guided block: group S, conventional blind block: group B) and GON block was performed. The same parameters were measured on group S and VAS scores were assessed at pretreatment, 1 week and 4 weeks after treatment on both groups. Results The GON had distance of 23.1 ± 3.4 mm (right) and 20.5 ± 2.8 mm (left) from EOP to GON. Its depth below the skin was 6.8 ± 1.5 mm (right) and 7.0 ± 1.3 mm (left). The distance from GON to occipital artery was 1.5 ± 0.6 mm (right) and 1.2 ± 0.6 mm (left) in volunteers. Initial VAS score of group S and group B patients were 6.4 ± 0.2 and 6.5 ± 0.2. VAS score of 4 weeks after injection were 2.3 ± 0.2 on group S and 3.8 ± 0.3 on group B (P = 0.0003). Conclusions The parameters measured in this study should be useful for GON block and ultrasound-guided blockade is likely to be a more effective technique than blind blockade in occipital headache treatment.


Korean Journal of Anesthesiology | 2012

Remifentanil used as adjuvant in general anesthesia for spinal fusion does not exhibit acute opioid tolerance

Jong Hoon Yeom; Kyoung Hun Kim; Myong-Su Chon; Jangwon Byun; Sang Yun Cho

Background Although acute tolerance to opioids, especially to remifentanil, has been demonstrated consistently in animal studies, the results of clinical trials in humans are controversial. The aim of this study was to determine whether intraoperative infusions of remifentanil used as an adjuvant in general anesthesia result in acute tolerance, an event manifested by increased postoperative pain and a higher opioid requirement than usual. Methods Sixty patients who underwent surgery under general anesthesia for spinal fusion were randomly assigned to receive sevoflurane-nitrous oxide-oxygen (group SO, n = 20), sevoflurane-remifentanil-nitrous oxide-oxygen (group SR, n = 20), or propofol-remifentanil-oxygen (group PR, n = 20) in a double-blinded manner. All patients within 1 hour after induction received PCA (fentanyl 0.4 µg/kg/ml and ondansetron 16 mg) administered intravenously at a basal infusion rate of 1 ml/h, after being intravenously injected with a loading dose of fentanyl (1 µg/kg). Data for fentanyl requirement, verbal Numerical Rating Scale (NRS) pain score at rest, and presence of nausea or vomiting were collected at 1, 24, and 48 hours after surgery. Results We did not find any significant difference in postoperative PCA fentanyl requirements, NRS or side effects among the groups. Conclusions Remifentanil as an adjuvant to sevoflurane or propofol in general anesthesia for adults having surgery for spinal fusion does not appear to cause acute opioid tolerance or hyperalgesia in patients. However, further studies are needed to elucidate whether sevoflurane and propofol exert a clinically significant effect on opioid-induced tolerance or hyperalgesia and whether this effect is related to the age of the patient, the dose and duration of remifentanil given and the intensity of pain experienced postoperatively.


Journal of Clinical Anesthesia | 2011

The optimal effect-site concentration of remifentanil for lightwand tracheal intubation during propofol induction without muscle relaxation

Jeong Uk Han; Sangyun Cho; Woo Jae Jeon; Jong Hoon Yeom; Woo Jong Shin; Jae Hang Shim; Kyoung Hun Kim

STUDY OBJECTIVE To determine the most suitable effect-site concentration of remifentanil during lightwand intubation when administered with a target-controlled infusion (TCI) of propofol at 4.0 μg/mL without neuromuscular blockade. DESIGN Prospective study using a modified Dixons up-and-down method. SETTING Operating room of an academic hospital. PATIENTS 28 ASA physical status 1 and 2 patients, aged 18-65 years, scheduled for minor elective surgery. INTERVENTIONS Anesthesia was induced by TCI propofol effect-site concentration to 4.0 μg/mL, and the dose of remifentanil given to each patient was determined by the response of the previously tested patient using 0.2 ng/mL as a step size. The first patient was tested at a target effect-site concentration of 4.0 ng/mL of remifentanil. If intubation was successful, the remifentanil dose was decreased by 0.2 ng/mL; if it failed, the remifentanil dose was increased by 0.2 ng/mL. Successful intubation was defined as excellent or good intubating conditions. MEASUREMENTS AND MAIN RESULTS The remifentanil effect-site concentration was measured. The optimal effect-site concentration of remifentanil for lightwand tracheal intubation during propofol induction using 2% propofol target effect-site concentration to 4 μg/mL was 2.16 ± 0.19 ng/mL. From probit analysis, the effect-site concentration of remifentanil required for successful lightwand intubation in 50% (EC50) and 95% (EC95) of adults was 2.11 ng/mL (95% CI 1.16-2.37 ng/mL) and 2.44 ng/mL (95% CI 2.20-3.79 ng/mL), respectively. CONCLUSION A remifentanil effect-site concentration of 2.16 ± 0.19 ng/mL given before a propofol effect-site concentration of 4 μg/mL allowed lightwand intubation without muscle relaxant.


Anesthesia & Analgesia | 2009

The use of remifentanil to facilitate the insertion of the Cobra perilaryngeal airway.

Woo Jae Jeon; Kyoung Hun Kim; Jung Kook Suh; Sang Yun Cho

BACKGROUND: The use of remifentanil before propofol administration facilitates the insertion of the Laryngeal Mask Airway. We designed the present study to determine whether remifentanil would also create more suitable conditions for providing Cobra Perilaryngeal airway (CobraPLA) insertion when administered with propofol. METHODS: Both remifentanil and propofol were given as effect-site target-controlled infusions. There were four groups of 25 patients each. The propofol effect-site concentration was set at 6 &mgr;g/mL in all groups. Group R1 received a target effect-site remifentanil concentration of 1 ng/mL, Group R2 received remifentanil at 2 ng/mL, Group R3 received remifentanil at 3 ng/mL, and Group R4 received remifentanil at 4 ng/mL before the induction of anesthesia with propofol. The ease of insertion of CobraPLA was graded by the following 3-point scale: Grade 1, excellent, no response to CobraPLA insertion; Grade 2, acceptable, gagging or swallowing with insertion of CobraPLA; Grade 3, poor, unable to open mouth or biting upon insertion of CobraPLA. RESULTS: The most patients ranked as excellent for the first CobraPLA insertion (Grade 1) were found in Group R4, which was significantly higher than Groups R1 and R2 (P < 0.01), whereas no significant difference was found when compared with Group R3. The duration of apnea showed a significant dose-related increase (P < 0.01), especially between Group R2 (median 2.95 min) and R3 (median 7.9 min), but there was no significant difference between Groups R3 and R4. The incidence of hypotension in Group R4 within 1 min after insertion of CobraPLA was significantly more than for Groups R1 and R2 (P < 0.01). No significant differences could be found between the incidence of hypotension between Group R3 and the other groups. The incidence of hypertension at 1 min postinsertion was significantly more common in Groups R1 and R2 than Groups R3 and R4 (P < 0.01). CONCLUSION: An effect-site concentration of remifentanil of 2 ng/mL provides excellent conditions for insertion of the CobraPLA on the first attempt with minimal hemodynamic perturbations and a shorter duration of apnea.


Korean Journal of Anesthesiology | 2014

End-tidal concentration of sevoflurane for reducing rocuronium-induced withdrawal reactions in adult patients: a comparison between male and female patients.

Jong Hoon Yeom; Kyoung Hun Kim; Gyu Ho Choe; Jae Min Lee

Background In this study, we assessed the 50% effective concentration (EC50) of sevoflurane for reducing a rocuronium-induced reaction, based on the Dixons up-and-down method. We also assessed the 50 and 95% effective end-tidal concentration of sevoflurane (ETsev), based on the probit regression curve of the probability of nonwithdrawal reaction. Methods We conducted a prospective, double-blind study in 23 males and 24 females. After using 2.5% thiopental sodium (4 mg/kg), anesthesia was induced in the patients. The patients then inhaled sevoflurane with 5 vol% in 6 L/min of oxygen. When the target ETsev was achieved, a nurse injected the intubating dose of rocuronium (0.6 mg/kg) for 5-10 s under the free flow of intravenous fluid. After the nurse evaluated the response, the nurse recorded the maximum heart rate during 30 s and the mean arterial pressure after rocuronium injection. Results Based on Dixons up-and-down method, the EC50 of sevoflurane was 2.5 ± 0.5 vol% in males and 2.5 ± 0.3 vol% in females. The probit regression curve of the probability of nonwithdrawal reaction showed that in males the 50% effective ETsev was 2.4 vol% (95% confidence interval [CI], 1.5-3.1 vol%) and the 95% effective ETsev was 3.5 vol% (95% CI, 2.9-11.0 vol%); in females, the 50% effective ETsev was 2.4 vol% (95% CI, 2.1-2.7 vol%) and the 95% effective ETsev was 3.0 vol% (95% CI, 2.7-4.5 vol%). Conclusions The inhalation of sevoflurane during the induction period may provide a simple and reliable means of reducing rocuronium-induced reactions without adverse hemodynamic changes. There was no significant difference between males and females.


Korean Journal of Anesthesiology | 2011

The general anesthesia experience of deletion 8p syndrome patient -A case report-.

Woo Jong Shin; Sang Duk Kim; Kyoung Hun Kim

A deletion 8p syndrome is a relatively uncommon congenital disease characterized by mental retardation associated with multiple malformation that make anesthetic management a challenge. Anesthetic management of a patient with deletion 8p syndrome may pose a serious problem mainly from difficult tracheal intubation, aspiration complication and cardiac malformation. We experienced a case of 10 year-old boy with a deletion 8p syndrome who underwent appendectomy under the general anesthesia. Intubation was performed by video glidescope after unsuccessful attempt with Macintosh laryngoscope. A high arched palate, short neck, poor patient cooperation due to mental retardation and occasional autistic behaviour made airway management difficult. This case should alert anesthesiologists to the greater difficulties of managing patients with deletion 8p syndrome.


Korean Journal of Anesthesiology | 2009

Comparison of volume-control and pressure-control ventilation during one-lung ventilation

Jong Hoon Yeom; Woo Jong Shin; Yu-Jung Kim; Jae-Hang Shim; Woo Jae Jeon; Sang Yun Cho; Kyoung Hun Kim

BACKGROUND We hypothesized that pressure control ventilation allows a more even distribution in the lung and better maintenance of the mean airway pressure than is achieved with volume control ventilation. We try to compare the effect of pressure control ventilation (PC) with that of volume control ventilation without an end-inspiratory pause (VC) during one-lung ventilation (OLV) in an anesthetized, paralyzed patient for performing thoracopic bullectomy of the lung. METHODS We ventilated 20 patients with VC and PC after the insertion of a thoracoscope in continual order for, at least for 15 minutes, for each, VC and PC procedure. At the end of VC and PC, the respiratory mechanics, gasometrics, and hemodynamic parameters were measured and collected. RESULTS We found no significant differences between VC and PC except for the peak inspiratory airway pressure (PIP), the mean airway pressure and the arterial oxygen partial pressure (PaO2). The PIP was significantly decreased from 27.0 +/- 6.0 cmH2O (VC) to 21.8 +/- 5.4 cmH2O (PC). The mean airway pressure was significantly increased from 8.6 +/- 1.6 cmH2O (VC) to 9.4 +/- 2.0 cmH2O (PC), and the PaO2 was significantly increased from 252.9 +/- 97.3 mmHg (VC) to 285.2 +/- 103.8 mmHg (PC). CONCLUSIONS If PC allows mechanical ventilation with the same tidal volume and respiratory rate as VC during OLV, then PC significantly increases the PaO2 but this is not clinically significant, and the PC significantly decreases the PIP, which induces barotrauma or volutrauma when the PIP is excessively high.


Korean Journal of Anesthesiology | 2009

Awareness during general anesthesia due to the unlock position of the vaporizer − A report on two cases −

Kyoung Hun Kim; Sang Yun Cho; Kyu Nam Kim; Jae-Hang Shim; Woo Jae Jeon; Jong Hoon Yeom; Woo Jong Shin

Awareness with recall after general anesthesia is a relatively infrequent occurrence and this awareness is often associated with significant adverse psychological sequelae, including posttraumatic stress disorder. The occurrence of awareness is often the consequence of the light anesthetic techniques with using minor anesthetic agents. Because the locking lever of the Penlon Sigma Delta Anesthetic vaporizer (sevoflurane) was at the unlock position, disconnection happened between the anesthetic machine and the vaporizer (the Selectatec(R) vaporizing system). In our two cases, the inhalation agents were not supplied and awareness with recall was identified after surgery. We recommend to check the concentration of the inhalation agents by monitoring the concentration of using endtidal inhalation agents and to measure the hypnotic level of anesthesia via the bispectral index (BIS) and the auditory evoked potential (AEP).

Collaboration


Dive into the Kyoung Hun Kim's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge