Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Kyoung Won Jang is active.

Publication


Featured researches published by Kyoung Won Jang.


Optics Express | 2012

Fiber-optic Cerenkov radiation sensor for proton therapy dosimetry

Kyoung Won Jang; Wook Jae Yoo; Sang Hun Shin; Dongho Shin; Bongsoo Lee

In proton therapy dosimetry, a fiber-optic radiation sensor incorporating a scintillator must undergo complicated correction processes due to the quenching effect of the scintillator. To overcome the drawbacks of the fiber-optic radiation sensor, we proposed an innovative method using the Cerenkov radiation generated in plastic optical fibers. In this study, we fabricated a fiber-optic Cerenkov radiation sensor without an organic scintillator to measure Cerenkov radiation induced by therapeutic proton beams. Bragg peaks and spread-out Bragg peaks of proton beams were measured using the fiber-optic Cerenkov radiation sensor and the results were compared with those of an ionization chamber and a fiber-optic radiation sensor incorporating an organic scintillator. From the results, we could obtain the Bragg peak and the spread-out Bragg peak of proton beams without quenching effects induced by the scintillator, and these results were in good agreement with those of the ionization chamber. We also measured the Cerenkov radiation generated from the fiber-optic Cerenkov radiation sensor as a function of the dose rate of the proton beam.


Journal of The Optical Society of Korea | 2010

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

Wook Jae Yoo; Kyoung Won Jang; Jeong Ki Seo; Ji Yeon Heo; Jin Soo Moon; Jang-Yeon Park; Bongsoo Lee

In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAClTEXg


Journal of Biomedical Optics | 2013

Application of Cerenkov radiation generated in plastic optical fibers for therapeutic photon beam dosimetry

Kyoung Won Jang; Takahiro Yagi; Cheol Ho Pyeon; Wook Jae Yoo; Sang Hun Shin; Chiyoung Jeong; Byung Jun Min; Dongho Shin; Tsuyoshi Misawa; Bongsoo Lee

^{(R)}


IEEE Transactions on Nuclear Science | 2008

Measurement of Two-Dimensional Photon Beam Distributions Using a Fiber-Optic Radiation Sensor for Small Field Radiation Therapy

Bongsoo Lee; Kyoung Won Jang; Dong Hyun Cho; Wook Jae Yoo; Sang Hun Shin; Hyung Sik Kim; Jeong Han Yi; Sin Kim; Hyosung Cho; Byung Gi Park; Joo Hyun Moon; Siyong Kim

l/TEXg system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.


Optics Express | 2013

Feasibility of fiber-optic radiation sensor using Cerenkov effect for detecting thermal neutrons

Kyoung Won Jang; Takahiro Yagi; Cheol Ho Pyeon; Wook Jae Yoo; Sang Hun Shin; Tsuyoshi Misawa; Bongsoo Lee

Abstract. A Cerenkov fiber-optic dosimeter (CFOD) is fabricated using plastic optical fibers to measure Cerenkov radiation induced by a therapeutic photon beam. We measured the Cerenkov radiation generated in optical fibers in various irradiation conditions to evaluate the usability of Cerenkov radiation for a photon beam therapy dosimetry. As a results, the spectral peak of Cerenkov radiation was measured at a wavelength of 515 nm, and the intensity of Cerenkov radiation increased linearly with increasing irradiated length of the optical fiber. Also, the intensity peak of Cerenkov radiation was measured in the irradiation angle range of 30 to 40 deg. In the results of Monte Carlo N-particle transport code simulations, the relationship between fluxes of electrons over Cerenkov threshold energy and energy deposition of a 6 MV photon beam had a nearly linear trend. Finally, percentage depth doses for the 6 MV photon beam could be obtained using the CFOD and the results were compared with those of an ionization chamber. Here, the mean dose difference was about 0.6%. It is anticipated that the novel and simple CFOD can be effectively used for measuring depth doses in radiotherapy dosimetry.


Japanese Journal of Applied Physics | 2006

Measurements and Characterization of Cerenkov Light in Fiber-Optic Radiation Sensor Irradiated by High-Energy Electron Beam

Bongsoo Lee; Dong Hyun Cho; Kyoung Won Jang; Soon-Cheol Chung; Jeong-Whan Lee; Sin Kim; Hyosung Cho

In this study, a fiber-optic radiation sensor with an organic scintillator is fabricated to measure high-energy photon beam from a clinical linear accelerator (CLINAC) and a fiberoptic sensor array is also fabricated to measure two-dimensional, high-resolution and real-time dose distributions for small field radiotherapy dosimetry. The scintillating lights generated from each organic sensor probe embedded and arrayed in a water phantom are guided by 10 m plastic optical fibers to the light- measuring device. The two-dimensional photon beam distributions in a water phantom are measured with different energies and field sizes of photon beams. Also, percent depth dose curves for 6 and 15 MV photon beams are obtained.


Optics Express | 2013

Simultaneous measurements of pure scintillation and Cerenkov signals in an integrated fiber-optic dosimeter for electron beam therapy dosimetry

Wook Jae Yoo; Sang Hun Shin; Dayeong Jeon; Seunghan Hong; Seon Geun Kim; Hyeok In Sim; Kyoung Won Jang; Seunghyun Cho; Bongsoo Lee

In this research, we propose a novel method for detecting thermal neutrons with a fiber-optic radiation sensor using the Cerenkov effect. We fabricate a fiber-optic radiation sensor that detects thermal neutrons with a Gd-foil, a rutile crystal, and a plastic optical fiber. The relationship between the fluxes of electrons inducing Cerenkov radiation in the sensor probe of the fiber-optic radiation sensor and thermal neutron fluxes is determined using the Monte Carlo N-particle transport code simulations. To evaluate the fiber-optic radiation sensor, the Cerenkov radiation generated in the fiber-optic radiation sensor by irradiation of pure thermal neutron beams is measured according to the depths of polyethylene.


IEEE Transactions on Nuclear Science | 2010

Measurements of Relative Depth Doses Using Fiber-Optic Radiation Sensor and EBT Film for Brachytherapy Dosimetry

Bongsoo Lee; Wook Jae Yoo; Kyoung Won Jang; Dong Hyun Cho; Jeong Ki Seo; Ji Yeon Heo; Sang Hun Shin; Joo Hyun Moon; Byung Gi Park; Young-Ho Cho; Sin Kim

In general, Cerenkov light can cause a problem in detecting a real light signal that is generated in a fiber-optic radiation sensor using an organic scintillator for dose measurements of high-energy electron beams. In this study, the intensity of Cerenkov light is measured and characterized as functions of incident angles, energy, and field size of the electron beam from a LINAC (linear accelerator). To remove or minimize Cerenkov light, a subtraction method using a background optical fiber is investigated.


Applied Radiation and Isotopes | 2011

Development and characterization of the integrated fiber-optic radiation sensor for the simultaneous detection of neutrons and gamma rays.

Kyoung Won Jang; Bongsoo Lee; Joo Hyun Moon

For real-time dosimetry in electron beam therapy, an integrated fiber-optic dosimeter (FOD) is developed using a water-equivalent dosimeter probe, four transmitting optical fibers, and a multichannel light-measuring device. The dosimeter probe is composed of two inner sensors, a scintillation sensor and a Cerenkov sensor, and each sensor has two different channels. Accordingly, we measured four separate light signals from each channel in the dosimeter probe, simultaneously, and then obtained the scintillation and Cerenkov signals using a subtraction method. To evaluate the performance of the integrated FOD, we measured the light signals according to the irradiation angle of the electron beam, the depth variation of the solid water phantom, and the electron beam energy. In conclusion, we demonstrated that the pure scintillation and Cerenkov signals obtained by an integrated FOD system based on a subtraction method can be effectively used for calibrating the conditions of high-energy electron beams in radiotherapy.


IEEE Transactions on Nuclear Science | 2008

Characterization of One-Dimensional Fiber-Optic Scintillating Detectors for Electron-Beam Therapy Dosimetry

Bongsoo Lee; Kyoung Won Jang; Dong Hyun Cho; Wook Jae Yoo; Sang Hun Shin; Gye-Rae Tack; Soon-Cheol Chung; Sin Kim; Hyosung Cho; Byung Gi Park; Joo Hyun Moon; Siyong Kim

In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator for brachytherapy dosimetry. Organic scintillators are made from a polystyrene base with wavelength-shifting fluors, and they do not disturb the radiation field due to their tissue or water-equivalent characteristics in a wide range of energies. The fiber-optic radiation sensor developed for this study provides a fast real-time response and convenient usage for brachytherapy dosimetry. For more accurate measurement, we have measured Cerenkov light using a dummy fiber and avoided dose measurement errors arising from high dose gradients in brachytherapy dosimetry. The Cerenkov light has been eliminated using a modified subtraction method. Also, the relative depth dose without the dose generated from Cerenkov lights is measured and compared with the results obtained using conventional EBT dosimetry films.

Collaboration


Dive into the Kyoung Won Jang's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Byung Gi Park

Soonchunhyang University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sin Kim

Jeju National University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge