L. I. Fedoseev
Russian Academy of Sciences
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by L. I. Fedoseev.
Instruments and Experimental Techniques | 2016
V. I. Nosov; O. S. Bolshakov; G. M. Bubnov; Vyacheslav F. Vdovin; I. I. Zinchenko; A. S. Marukhno; P. L. Nikiforov; L. I. Fedoseev; A. A. Shvetsov
The MIAP-2 radiometric complex intended for measuring the atmospheric absorption in the millimeter wavelength range (2 and 3 mm) is described. The complex is based on two solid-state modulation radiometers with wave ranges of 84–99 GHz and 132–148 GHz, which are equipped with horn-lens antennas. The device determines an optical depth in the millimeter wave range using the atmospheric-dip method and the absolute signal calibration method in the fully automated mode under the remote control via the Internet. A set of observations was performed in the stationary mode and in mountain expedition conditions. The reliability of the device was evaluated from 2-year operation results.
Radiophysics and Quantum Electronics | 1999
V. G. Bozhkov; V. A. Genneberg; Yu. A. Dryagin; L. I. Fedoseev
We describe the design of a superheterodyne receiver with a balanced monolithic integrated mixer and describe the technique and results of parameter measurements of the receiver and mixer over the frequency range 287–365 GHz. In the middle of this range, the double-band noise temperature of the receiver is 1500±50 K, while the double-band noise temperature and conversion loss of the mixer are 1250±50 K and 10±0.5 dB, respectively. Comparison with mixers and receivers of other types is performed.
Instruments and Experimental Techniques | 2011
A. A. Shvetsov; L. I. Fedoseev; O. S. Bol’shakov; D. A. Karashtin
A laboratory model of the spectroradiometer for the complex for thermal sounding of middle atmosphere has been designed. Based on the self-radiation spectra of the atmosphere measured by this instrument in the frequency range of 52.45–53.20 GHz, it is possible to retrieve the vertical temperature profile in the stratosphere and the upper troposphere. The temperature profiles obtained in the test cycle of round-theclock observations in the altitude range of 10–55 km are in good agreement with the satellite data.
Instruments and Experimental Techniques | 2016
A. A. Shvetsov; V. G. Ryskin; M. Yu. Kulikov; L. M. Kukin; L. I. Fedoseev; A. M. Shchitov; A. M. Feigin
The laboratory model of a mobile solid-state uncooled microwave spectroradiometer, operating in the frequency range of 50 to 55 GHz is described. It is designed for remote passive monitoring of the tropospheric temperature. The spectroradiometer consists of a heterodyne receiver with a low noise amplifier at input and 8-channel spectrum analyzer. To ensure the internal calibration of the intensity of the received atmospheric radio emission using the built-in unit type modulator-calibrator based on GaAs diodes with the Schottky barrier. The antenna system of the spectroradiometer consists of a teflon enlightened lens and conical corrugated horn. The device is equipped with an automated control system process measurement, calibration, and data pre-processing.
international crimean conference microwave and telecommunication technology | 2008
L. I. Fedoseev; A. A. Shvetsov; A. P. Shkaev; V. M. Demkin; D. A. Karashtin; L.M. Kukin; V. G. Bozhkov; V. A. Genneberg; I. V. Petrov; A. M. Schitov
Features of the functional scheme and design of millimeter wave radiometers with a new device - a solid state modulator-calibrator using planar Schottky barrier diode microcircuit - are presented.
Radiophysics and Quantum Electronics | 2002
V. G. Bozhkov; V. A. Genneberg; Yu. A. Dryagin; L. M. Kukin; L. I. Fedoseev; A. A. Shvetsov
We describe the technique, apparatus, and the results of studies of the possibility of millimeter-wave single-sideband reception with minimum loss, associated with conversion into image. The single-sideband noise temperature of the receivers is improved by a factor of 1.4-1.9 in the N and Y bands.
Radiophysics and Quantum Electronics | 2000
V. G. Bozhkov; V. A. Genneberg; L. M. Koukin; L. I. Fedoseev
We briefly describe the design and the method and results of measurements of a miniature mixer-amplifier module (MAM). The double-sideband noise temperature is less than 1000 K at 81-121 GHz frequencies and is 390±30 K at 115 GHz. The gain is between 49 and 56 dB and the intermediate frequency band is from 1 to 2 GHz.
Radiophysics and Quantum Electronics | 1998
A. A. Krasil’nikov; Yu. Yu. Kulikov; V. G. Ryskin; L. I. Fedoseev
We describe the equipment and methods of observation of variation of the state of some stratospheric and mesospheric gas components and present the results of measurements of the time and space ozone variations at altitudes of from 20 to 70 km above Nizhny Novgorod: the seasonal and diurnal variation and “ozone clouds.” The seasonal variation of ozone content at altitudes exceeding 22 km and the vertical distribution of ozone are compared with the measurement results obtained from the TOMS and CRISTA satellites. We also show the results of observations of mesospheric carbon monoxide.
Instruments and Experimental Techniques | 2017
A. A. Krasilnikov; M. Yu. Kulikov; L. M. Kukin; V. G. Ryskin; L. I. Fedoseev; A. A. Shvetsov; O. S. Bolshakov; A. M. Shchitov; A. M. Feigin
The work presents the results of upgrading of microwave spectroradiometer for ground-based remote sensing of Earth’s ozone layer improving essentially the noise temperature (up to value less 1500 K). For this, the low-noise high frequency amplifier was set up in front of the receiver and temperature control of the instrument was changed for stable work of the amplifier.
Instruments and Experimental Techniques | 2017
A. A. Krasilnikov; M. Yu. Kulikov; V. G. Ryskin; L. I. Fedoseev; A. A. Shvetsov; V. G. Bozhkov; O. S. Bol’shakov
A system for automatic internal calibration of millimeter-range radiometers is described. This system is based on an electrically controlled modulator–calibrator, which is a compact solid-state device that combines the functions of a modulator and a source of stable noise calibration signals. Stability of the calibration levels is provided by thermostatting the modulator–calibrator case and stabilization of the control currents. The calibration and data-collection process is governed by software using a special digital module and a personal computer.