Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where L. Latronico is active.

Publication


Featured researches published by L. Latronico.


Astroparticle Physics | 2009

On possible interpretations of the high energy electron–positron spectrum measured by the Fermi Large Area Telescope

D. Grasso; Stefano Profumo; A. W. Strong; L. Baldini; R. Bellazzini; Elliott D. Bloom; J. Bregeon; G. Di Bernardo; Daniele Gaggero; N. Giglietto; T. Kamae; L. Latronico; F. Longo; M. N. Mazziotta; A. A. Moiseev; A. Morselli; J. F. Ormes; M. Pesce-Rollins; M. Pohl; M. Razzano; C. Sgrò; G. Spandre; T. E. Stephens

The Fermi-LAT experiment recently reported high precision measurements of the spectrum of cosmic-ray electrons-plus-positrons (CRE) between 20 GeV and 1 TeV. The spectrum shows no prominent spectral features, and is significantly harder than that inferred from several previous experiments. Here we discuss several interpretations of the Fermi results based either on a single large scale Galactic CRE component or by invoking additional electron–positron primary sources, e.g. nearby pulsars or particle dark matter annihilation. We show that while the reported Fermi-LAT data alone can be interpreted in terms of a single component scenario, when combined with other complementary experimental results, specifically the CRE spectrum measured by H.E.S.S. and especially the positron fraction reported by PAMELA between 1 and 100 GeV, that class of models fails to provide a consistent interpretation. Rather, we find that several combinations of parameters, involving both the pulsar and dark matter scenarios, allow a consistent description of those results. We also briefly discuss the possibility of discriminating between the pulsar and dark matter interpretations by looking for a possible anisotropy in the CRE flux.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2004

Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode

R. Bellazzini; F. Angelini; L. Baldini; Francesco Bitti; A. Brez; M. Ceccanti; L. Latronico; Marco Maria Massai; M. Minuti; N. Omodei; M. Razzano; C. Sgrò; G. Spandre; Enrico Costa; Paolo Soffitta

Abstract In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 μ m and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the individual pixel to the external electronics chain. For this reason a custom CMOS array of 2101 active pixels with 80 μ m pitch, directly used as the charge collecting anode of a GEM amplifying structure, has been developed and built. Each charge collecting pad, hexagonally shaped, realized using the top metal layer of a deep submicron VLSI technology is individually connected to a full electronics chain (pre-amplifier, shaping-amplifier, sample & hold, multiplexer) which is built immediately below it by using the remaining five active layers. The GEM and the drift electrode window are assembled directly over the chip so the ASIC itself becomes the pixelized anode of a MPGD. With this approach, for the first time, gas detectors have reached the level of integration and resolution typical of solid-state pixel detectors. Results from the first tests of this new read-out concept are presented. An Astronomical X-ray Polarimetry application is also discussed.


Physical Review D | 2017

Cosmic-ray electron-positron spectrum from 7 GeV to 2 TeV with the Fermi Large Area Telescope

S. Abdollahi; M. Ackermann; M. Ajello; W. B. Atwood; L. Baldini; G. Barbiellini; D. Bastieri; R. Bellazzini; E. D. Bloom; R. Bonino; T. Brandt; J. Bregeon; P. Bruel; R. Buehler; R. A. Cameron; R. Caputo; M. Caragiulo; Daniel Castro; E. Cavazzuti; C. Cecchi; A. Chekhtman; S. Ciprini; J. Cohen-Tanugi; F. Costanza; A. Cuoco; S. Cutini; F. D'Ammando; F. de Palma; R. Desiante; S. W. Digel

We present a measurement of the cosmic-ray electron+positron spectrum between 7 GeV and 2 TeV performed with almost seven years of data collected with the Fermi Large Area Telescope. We find that the spectrum is well fit by a broken power law with a break energy at about 50 GeV. Above 50 GeV, the spectrum is well described by a single power law with a spectral index of 3.07 ± 0.02 (stat+syst) ± 0.04 (energy measurement). An exponential cutoff lower than 1.8 TeV is excluded at 95% CL. PACS numbers: 98.70.Sa, 96.50.sb, 95.85.Ry, 95.55.Vj


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2008

Low energy polarization sensitivity of the Gas Pixel Detector

Fabio Muleri; Paolo Soffitta; L. Baldini; R. Bellazzini; J. Bregeon; A. Brez; Enrico Costa; M. Frutti; L. Latronico; M. Minuti; Maria Barbara Negri; N. Omodei; M. Pesce-Rollins; Michele Pinchera; M. Razzano; A. Rubini; C. Sgrò; G. Spandre

An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) positive measurement of polarized X-ray emission from an astrophysical source. The estimated sensitivity of the current prototype peaks at an energy of about 3 keV, but the lack of readily available polarized sources in this energy range has prevented the measurement of detector polarimetric performances. In this paper we present the measurement of the Gas Pixel Detector polarimetric sensitivity at energies of a few keV and the new, light, compact and transportable polarized source that was devised and built to this aim. Polarized photons are produced, from unpolarized radiation generated with an X-ray tube, by means of Bragg diffraction at nearly 45 ◦ . The diffraction angle is constrained with two orthogonal capillary plates, which allow good collimation with limited size thanks to the 10 µm diameter holes. Polarized photons at energy as low as a few keV can be produced with a proper choice of diffracting crystal, while the maximum energy is limited by the X-ray tube voltage, since all the orders defined by the crystal lattice spacing are diffracted. The best trade-off between reasonable fluxes and high degree of polarization can be achieved selecting the degree of collimation provided by capillary plates. The employment of mosaic graphite and flat aluminum crystals allow the production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from the diffraction of unpolarized continuum or line emission. The measured modulation factor of the Gas Pixel Detector at these energies is in good agreement with the estimates derived from a Monte Carlo software, which was up to now employed for driving the development of the instrument and for estimating its low energy sensitivity. In this paper we present the excellent polarimetric performance of the Gas Pixel Detector at energies where the peak sensitivity is expected. These measurements not only support our previous claims of high sensitivity but confirm the feasibility of astrophysical X-ray photoelectric polarimetry.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2010

Spectral and polarimetric characterization of the Gas Pixel Detector filled with dimethyl ether

Fabio Muleri; Paolo Soffitta; L. Baldini; R. Bellazzini; A. Brez; Enrico Costa; Sergio Fabiani; F. Krummenacher; L. Latronico; F. Lazzarotto; M. Minuti; Michele Pinchera; A. Rubini; C. Sgrò; G. Spandre

The Gas Pixel Detector belongs to the very limited class of gas detectors optimized for the measurement of X-ray polarization in the emission of astrophysical sources. The choice of the mixture in which X-ray photons are absorbed and photoelectrons propagate, deeply affects both the energy range of the instrument and its performance in terms of gain, track dimension and ultimately, polarimetric sensitivity. Here we present the characterization of the Gas Pixel Detector with a 1 cm thick cell filled with dimethyl ether (DME) at 0.79 atm, selected among other mixtures for the very low diffusion coefficient. Almost completely polarized and monochromatic photons were produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg diffraction at nearly 45 degrees. For the first time ever, we measured the modulation factor and the spectral capabilities of the instrument at energies as low as 2.0 key, but also at 2.6, 3.7, 4.0, 5.2 and 7.8 key. These measurements cover almost completely the energy range of the instrument and allows to compare the sensitivity achieved with that of the standard mixture, composed of helium and DME


The Astrophysical Journal | 2017

Fermi-LAT Observations of High-energy Behind-the-limb Solar Flares

M. Ackermann; A. Allafort; L. Baldini; G. Barbiellini; D. Bastieri; R. Bellazzini; E. Bissaldi; R. Bonino; E. Bottacini; J. Bregeon; P. Bruel; R. Buehler; R. A. Cameron; M. Caragiulo; P. A. Caraveo; E. Cavazzuti; C. Cecchi; E. Charles; S. Ciprini; F. Costanza; S. Cutini; F. D'Ammando; F. de Palma; R. Desiante; S. W. Digel; N. Di Lalla; M. Di Mauro; L. Di Venere; P. S. Drell; C. Favuzzi

We report on the Fermi-LAT detection of high-energy emission from the behind-the-limb (BTL) solar flares that occurred on 2013 October 11, and 2014 January 6 and September 1. The Fermi-LAT observations are associated with flares from active regions originating behind both the eastern and western limbs, as determined by STEREO. All three flares are associated with very fast coronal mass ejections (CMEs) and strong solar energetic particle events. We present updated localizations of the >100 MeV photon emission, hard X-ray (HXR) and EUV images, and broadband spectra from 10 keV to 10 GeV, as well as microwave spectra. We also provide a comparison of the BTL flares detected by Fermi-LAT with three on-disk flares and present a study of some of the significant quantities of these flares as an attempt to better understand the acceleration mechanisms at work during these occulted flares. We interpret the HXR emission to be due to electron bremsstrahlung from a coronal thin-target loop top with the accelerated electron spectra steepening at semirelativistic energies. The >100 MeV gamma-rays are best described by a pion-decay model resulting from the interaction of protons (and other ions) in a thick-target photospheric source. The protons are believed to have been accelerated (to energies >10 GeV) in the CME environment and precipitate down to the photosphere from the downstream side of the CME shock and landed on the front side of the Sun, away from the original flare site and the HXR emission.


1st Gamma-ray Large Area Space Telescope Symposium, GLAST, 5 February 2007 through 8 February 2007, Stanford, CA, United States | 2007

Preliminary results of the LAT Calibration Unit beam tests

L. Baldini; G. Barbiellini; R. Bellazzini; J.R. Bogart; G. Bogaert; E. Bonamente; J. Bregeon; A. Brez; M. Brigida; A. W. Borgland; P. Bruel; G. A. Caliandro; C. Cecchi; F. P. Ceglie; E. Charles; A. Chekhtman; R. Claus; J. Cohen-Tanugi; E. Do Couto E Silva; R. Dubois; J. Conrad; D. Dumora; C. Favuzzi; Z. Fewtrell; W. B. Focke; S. Funk; P. Fusco; F. Gargano; S. Germani; B. Giebels

The calibration strategy of the GLAST Large Area Telescope (LAT) combines analysis of cosmic ray data with accelerator particle beams measurements. An advanced Monte Carlo simulation of the LAT, based on the Geant4 package, was set up to reproduce the LAT response to such radiation and to benchmark the event reconstruction and the background rejection strategy before launch and during operation. To validate the LAT simulation, a massive campaign of beam tests was performed between July and November 2006, in parallel with the LAT integration and test, on the LAT Calibration Unit. This is a detector built with spare flight modules and flight‐like readout electronics, which was exposed to a large variety of beams, representing the whole spectrum of the signal that will be detected by the LAT, using the CERN and the GSI accelerator facilities. Beams of photons (0 – 2.5 GeV), electrons (1 – 300 GeV), hadrons (π and p, a few GeV – 100 GeV) and ions (C; Xe, 1.5 GeV/n) were shot through the CU to measure the phys...


IEEE Transactions on Nuclear Science | 2002

X-ray polarimetry with a micro pattern gas detector with pixel readout

R. Bellazzini; F. Angelini; L. Baldini; A. Brez; Enrico Costa; L. Latronico; N. Lumb; M.M. Massai; N. Omodei; Paolo Soffitta; G. Spandre

In astronomy there are basically four kinds of observations to extract the information carried by electromagnetic radiation: photometry, imaging, spectroscopy, and polarimetry. By optimal exploitation of the first three techniques, X-ray astronomy has been able to unveil the violent world of compact high-energy sources. Here, we report on a new instrument that brings high efficiency also to X-ray polarimetry, the last unexplored field of X-ray astronomy. It will then be possible to resolve the internal structures of compact objects, which otherwise would remain inaccessible even to X-ray interferometry. The new instrument derives the polarization information from the track of the photoelectron imaged by a finely subdivided gas pixel detector. Its great improvement of sensitivity (at least two order of magnitude) will allow direct exploration of the most dramatic objects of the X-ray sky.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1997

Technique for the characterization of discharges in micro-strip gas chambers

R. Bellazzini; A. Brez; L. Latronico; N. Lumb; G. Spandre; M. Bozzo; A. Cattai; A. Tsirou

A method is described for the characterization and counting of discharges in MSGCs. It is shown that the technique is sensitive enough to detect the micro-discharges which occur prior to full sparking, with a detection efficiency of 0.8. Some example results are presented, showing the variation of micro-discharge rate with gain.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2003

Techniques and detectors for polarimetry in X-ray astronomy

Paolo Soffitta; L. Baldini; R. Bellazzini; A. Brez; Enrico Costa; G. Di Persio; L. Latronico; N. Omodei; Luigi Pacciani; G. Spandre

Abstract Polarimeters flown so far were based on the Thomson scattering and Bragg diffraction with intrinsically limited sensitivity. In the present paper, we review the experiments based on those techniques and discuss possible optimization and implementation for X-ray astronomy.

Collaboration


Dive into the L. Latronico's collaboration.

Top Co-Authors

Avatar

L. Baldini

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A. Brez

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

C. Sgrò

Scuola Normale Superiore di Pisa

View shared research outputs
Top Co-Authors

Avatar

N. Omodei

SLAC National Accelerator Laboratory

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. Minuti

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Researchain Logo
Decentralizing Knowledge