L. Tranchina
University of Rome Tor Vergata
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by L. Tranchina.
Journal of Glaucoma | 2013
L. Tranchina; Marco Lombardo; Francesco Oddone; Sebastiano Serrao; Domenico Schiano Lomoriello; Pietro Ducoli
Purpose:To estimate the influence of corneal properties on intraocular pressure (IOP) differences between an air-puff tonometer (NT530P; Nidek) and the Goldmann applanation tonometer (Haag-Streit). Patients and Methods:The influence of central corneal thickness (CCT), keratometry, and Ocular Response Analyzer (Reichert) measurements of corneal viscoelasticity [corneal hysteresis (CH) and corneal resistance factor (CRF)] on IOP differences between tonometers was evaluated. Results:The CRF was calculated to be the best predictor of the differences in IOP readings between tonometers (r2=0.23; P<0.001), followed by CCT (r2=0.15; P=0.003) and CH (r2=0.14; P=0.003). Keratometry performed very poorly as lone predictor of IOP differences. In a multiple regression model, CRF, CH, and CCT together accounted for 25% (r2=0.25; P<0.01) of the variance in IOP reading differences between tonometers. Conclusions:Corneal resistance to applanation induced by either contact or noncontact tonometers was calculated to be the most determinant factor in influencing IOP differences between applanation tonometers.
The Open Ophthalmology Journal | 2013
D. Schiano Lomoriello; Marco Lombardo; Luca Gualdi; Luca Iacobelli; L. Tranchina; Pietro Ducoli; Sebastiano Serrao
Purpose: To evaluate the position stability of a phakic intraocular lens (Cachet pIOL; Alcon, Laboratories, Inc., Fort Worth, TX) in the anterior chamber (AC) during a 6-months follow-up. Methods: Thirty eyes of 16 subjects underwent a Cachet pIOL implantation for the correction of high myopia from -6.50 to -16.00 D with plano targeted refraction. The position stability of the Cachet pIOL was evaluated using an Anterior Segment-OCT (AS-OCT, Carl Zeiss AG, Oberkochen, Germany) at 1- and 6-months postoperatively. Three measurements have been taken into account: 1) the minimum distance between the anterior surface of the Cachet pIOL optic disk and the central corneal endothelium; 2) the minimum distance between the optic disk’s edges of the pIOL and the endothelium; 3) the minimum distance between the posterior surface of the pIOL optic disk and the anterior surface of the crystalline lens. The endothelial cell density (ECD) was also recorded. Results: No statistically significant changes of the Cachet pIOL position in the AC were found during follow-up. The average changes were ≤0.1 mm between 1- and 6-months postoperatively (P>0.05). At the end of follow-up, The mean ECD loss was 0.7 % (from 2794 ± 337 cell/mm2 to 2776 ± 388 cell/mm2; P>0.05). Conclusion: A high position stability of the Cachet pIOL in the anterior chamber was shown during a 6-months follow-up.
Graefes Archive for Clinical and Experimental Ophthalmology | 2011
L. Tranchina; Marco Centofanti; Francesco Oddone; Lucia Tanga; Gloria Roberti; Laura Liberatoscioli; Claudio Cortese; Gianluca Manni
Graefes Archive for Clinical and Experimental Ophthalmology | 2011
Domenico Schiano Lomoriello; Marco Lombardo; L. Tranchina; Francesco Oddone; Sebastiano Serrao; Pietro Ducoli
Investigative Ophthalmology & Visual Science | 2010
M. Michelessi; Francesco Oddone; M. Centofanti; Lucia Tanga; S. Lotito; Gloria Roberti; L. Tranchina; Gianluca Manni
Investigative Ophthalmology & Visual Science | 2011
L. Tranchina; Marco Lombardo; Francesco Oddone; Sebastiano Serrao; Domenico Schiano Lomoriello; Pietro Ducoli; Marco Centofanti
Investigative Ophthalmology & Visual Science | 2011
Domenico Schiano Lomoriello; L. Tranchina; Luca Iacobelli; Marco Lombardo; Luca Gualdi; Domenico Amato; Pietro Ducoli
Investigative Ophthalmology & Visual Science | 2011
Luca Iacobelli; L. Tranchina; Marco Lombardo; Luca Gualdi; Federica Gualdi; Domenico Amato; Domenico Schiano Lomoriello; Piero Ducoli
Investigative Ophthalmology & Visual Science | 2010
Lucia Tanga; Francesco Oddone; Gianluca Manni; S. Lotito; L. Tranchina; Gloria Roberti; M. Michelessi; Paolo Fogagnolo; M. Centofanti
Investigative Ophthalmology & Visual Science | 2010
Gloria Roberti; Francesco Oddone; M. Centofanti; Lucia Tanga; S. Lotito; L. Tranchina; M. Michelessi; Michele Figus; Gianluca Manni