Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Lars C. Ebert is active.

Publication


Featured researches published by Lars C. Ebert.


Surgical Innovation | 2012

You Can’t Touch This: Touch-free Navigation Through Radiological Images

Lars C. Ebert; Gary M. Hatch; Garyfalia Ampanozi; Michael J. Thali; Steffen Ross

Keyboards, mice, and touch screens are a potential source of infection or contamination in operating rooms, intensive care units, and autopsy suites. The authors present a low-cost prototype of a system, which allows for touch-free control of a medical image viewer. This touch-free navigation system consists of a computer system (IMac, OS X 10.6 Apple, USA) with a medical image viewer (OsiriX, OsiriX foundation, Switzerland) and a depth camera (Kinect, Microsoft, USA). They implemented software that translates the data delivered by the camera and a voice recognition software into keyboard and mouse commands, which are then passed to OsiriX. In this feasibility study, the authors introduced 10 medical professionals to the system and asked them to re-create 12 images from a CT data set. They evaluated response times and usability of the system compared with standard mouse/keyboard control. Users felt comfortable with the system after approximately 10 minutes. Response time was 120 ms. Users required 1.4 times more time to re-create an image with gesture control. Users with OsiriX experience were significantly faster using the mouse/keyboard and faster than users without prior experience. They rated the system 3.4 out of 5 for ease of use in comparison to the mouse/keyboard. The touch-free, gesture-controlled system performs favorably and removes a potential vector for infection, protecting both patients and staff. Because the camera can be quickly and easily integrated into existing systems, requires no calibration, and is low cost, the barriers to using this technology are low.


International Journal of Medical Robotics and Computer Assisted Surgery | 2009

Virtobot—a multi‐functional robotic system for 3D surface scanning and automatic post mortem biopsy

Lars C. Ebert; Wolfgang Ptacek; Silvio Naether; Martin Fürst; Steffen Ross; Ursula Buck; Stefan Weber; Michael J. Thali

The Virtopsy project, a multi‐disciplinary project that involves forensic science, diagnostic imaging, computer science, automation technology, telematics and biomechanics, aims to develop new techniques to improve the outcome of forensic investigations. This paper presents a new approach in the field of minimally invasive virtual autopsy for a versatile robotic system that is able to perform three‐dimensional (3D) surface scans as well as post mortem image‐guided soft tissue biopsies.


European Journal of Radiology | 2012

Radiologic identification of disaster victims: A simple and reliable method using CT of the paranasal sinuses

Thomas D. Ruder; Markus Kraehenbuehl; Walther F. Gotsmy; Sandra Mathier; Lars C. Ebert; Michael J. Thali; Gary M. Hatch

OBJECTIVE To assess the reliability of radiologic identification using visual comparison of ante and post mortem paranasal sinus computed tomography (CT). SUBJECTS AND METHODS The study was approved by the responsible justice department and university ethics committee. Four blinded readers with varying radiological experience separately compared 100 post mortem to 25 ante mortem head CTs with the goal to identify as many matching pairs as possible (out of 23 possible matches). Sensitivity, specificity, positive and negative predictive values were calculated for all readers. The chi-square test was applied to establish if there was significant difference in sensitivity between radiologists and non-radiologists. RESULTS For all readers, sensitivity was 83.7%, specificity was 100.0%, negative predictive value (NPV) was 95.4%, positive predictive value (PPV) was 100.0%, and accuracy was 96.3%. For radiologists, sensitivity was 97.8%, NPV was 99.4%, and accuracy was 99.5%. For non-radiologists, average sensitivity was 69.6%, negative predictive value (NPV) was 91.7%, and accuracy was 93.0%. Radiologists achieved a significantly higher sensitivity (p < 0.01) than non-radiologists. CONCLUSIONS Visual comparison of ante mortem and post mortem CT of the head is a robust and reliable method for identifying unknown decedents, particularly in regard to positive matches. The sensitivity and NPV of the method depend on the readers experience.


Legal Medicine | 2010

A new approach in virtopsy: Postmortem ventilation in multislice computed tomography

Tanja Germerott; Ulrich Preiss; Lars C. Ebert; Thomas D. Ruder; Steffen Ross; Patricia M. Flach; Garyfalia Ampanozi; Laura Filograna; Michael J. Thali

Although postmortem imaging has gained prominence in the field of forensic medicine, evaluation of the postmortem lung remains problematic. Specifically, differentiation of normal postmortem changes and pathological pulmonary changes is challenging and at times impossible. In this study, five corpses were ventilated using a mechanical ventilator with a pressure of 40 mbar (40.8 cm H(2)O). The ventilation was performed via an endotracheal tube, a larynx mask or a continuous positive airway pressure mask. Postmortem computed tomographic images of the lungs before and with a ventilation of 40 mbar (40.8 cm H(2)O) were evaluated and the lung volumes were measured with segmentation software. Postmortem ventilation led to a clearly visible decrease of both the density in the dependant parts of the lungs and ground glass attenuation, whereas consolidated areas remained unchanged. Furthermore, a mean increase in the lung volume of 2.10 l was seen. Pathological changes such as septal thickening or pulmonary nodules in the lung parenchyma became more detectable with postmortem ventilation. Intracorporal postmortem mechanical ventilation of the lungs appears to be an effective method for enhancing detection of small pathologies of the lung parenchyma as well as for discriminating between consolidation, ground glass attenuation and position-dependent density.


Journal of Forensic and Legal Medicine | 2008

CT data-based navigation for post-mortem biopsy – A feasibility study

Emin Aghayev; Lars C. Ebert; Andreas Christe; Christian Jackowski; Tobias Rudolph; Jens Kowal; Peter Vock; Michael J. Thali

INTRODUCTION Recent advances in medical imaging have brought post-mortem minimally invasive computed tomography (CT) guided percutaneous biopsy to public attention. AIMS The goal of the following study was to facilitate and automate post-mortem biopsy, to suppress radiation exposure to the investigator, as may occur when tissue sampling under computer tomographic guidance, and to minimize the number of needle insertion attempts for each target for a single puncture. METHODS AND MATERIALS Clinically approved and post-mortem tested ACN-III biopsy core needles (14 gauge x 160 mm) with an automatic pistol device (Bard Magnum, Medical Device Technologies, Denmark) were used for probe sampling. The needles were navigated in gelatine/peas phantom, ex vivo porcine model and subsequently in two human bodies using a navigation system (MEM centre/ISTB Medical Application Framework, Marvin, Bern, Switzerland) with guidance frame and a CT (Emotion 6, Siemens, Germany). RESULTS Biopsy of all peas could be performed within a single attempt. The average distance between the inserted needle tip and the pea centre was 1.4mm (n=10; SD 0.065 mm; range 0-2.3 mm). The targets in the porcine liver were also accurately punctured. The average of the distance between the needle tip and the target was 0.5 mm (range 0-1 mm). Biopsies of brain, heart, lung, liver, pancreas, spleen, and kidney were performed on human corpses. For each target the biopsy needle was only inserted once. The examination of one body with sampling of tissue probes at the above-mentioned locations took approximately 45 min. CONCLUSIONS Post-mortem navigated biopsy can reliably provide tissue samples from different body locations. Since the continuous update of positional data of the body and the biopsy needle is performed using optical tracking, no control CT images verifying the positional data are necessary and no radiation exposure to the investigator need be taken into account. Furthermore, the number of needle insertions for each target can be minimized to a single one with the ex vivo proven adequate accuracy and, in contrast to conventional CT guided biopsy, the insertion angle may be oblique. Navigation for minimally invasive tissue sampling is a useful addition to post-mortem CT guided biopsy.


Journal of Forensic and Legal Medicine | 2012

CT based volume measurement and estimation in cases of pericardial effusion

Lars C. Ebert; Garyfalia Ampanozi; Thomas D. Ruder; Gary M. Hatch; Michael J. Thali; Tanja Germerott

The measurement of fluid volumes in cases of pericardial effusion is a necessary procedure during autopsy. With the increased use of virtual autopsy methods in forensics, the need for a quick volume measurement method on computed tomography (CT) data arises, especially since methods such as CT angiography can potentially alter the fluid content in the pericardium. We retrospectively selected 15 cases with hemopericardium, which underwent post-mortem imaging and autopsy. Based on CT data, the pericardial blood volume was estimated using segmentation techniques and downsampling of CT datasets. Additionally, a variety of measures (distances, areas and 3D approximations of the effusion) were examined to find a quick and easy way of estimating the effusion volume. Segmentation of CT images as shown in the present study is a feasible method to measure the pericardial fluid amount accurately. Downsampling of a dataset significantly increases the speed of segmentation without losing too much accuracy. Some of the other methods examined might be used to quickly estimate the severity of the effusion volumes.


Journal of The Mechanical Behavior of Biomedical Materials | 2014

Specimen specific parameter identification of ovine lumbar intervertebral discs: On the influence of fibre–matrix and fibre–fibre shear interactions

Christoph Reutlinger; Alexander Bürki; Vaclav Brandejsky; Lars C. Ebert; Philippe Büchler

Numerical models of the intervertebral disc, which address mechanical questions commonly make use of the difference in water content between annulus and nucleus, and thus fluid and solid parts are separated. Despite this simplification, models remain complex due to the anisotropy and nonlinearity of the annulus and regional variations of the collagen fibre density. Additionally, it has been shown that cross-links make a large contribution to the stiffness of the annulus. Because of this complex composite structure, it is difficult to reproduce several sets of experimental data with one single set of material parameters. This study addresses the question to which extent the ultrastructure of the intervertebral disc should be modelled so that its moment-angle behaviour can be adequately described. Therefore, a hyperelastic constitutive law, based on continuum mechanical principles was derived, which does not only consider the anisotropy from the collagen fibres, but also interactions among the fibres and between the fibres and the ground substance. Eight ovine lumbar intervertebral discs were tested on a custom made spinal loading simulator in flexion/extension, lateral bending and axial rotation. Specimen-specific geometrical models were generated using CT images and T2 maps to distinguish between annulus fibrosus and nucleus pulposus. For the identification of the material parameters the annulus fibrosus was described with two scenarios: with and without fibre-matrix and fibre-fibre interactions. Both scenarios showed a similar behaviour on a load displacement level. Comparing model predictions to the experimental data, the mean RMS of all specimens and all load cases was 0.54±0.15° without the interaction and 0.54±0.19° when the fibre-matrix and fibre-fibre interactions were included. However, due to the increased stiffness when cross-links effects were included, this scenario showed more physiological stress-strain relations in uniaxial and biaxial stress states. Thus, the present study suggests that fibre-matrix and fibre-fibre interactions should be considered in the constitutive law when the model addresses questions concerning the stress field of the annulus fibrosus.


Legal Medicine | 2012

Format preferences of district attorneys for post-mortem medical imaging reports: Understandability, cost effectiveness, and suitability for the courtroom: A questionnaire based study

Garyfalia Ampanozi; David Zimmermann; Gary M. Hatch; Thomas D. Ruder; Steffen Ross; Patricia M. Flach; Michael J. Thali; Lars C. Ebert

AIMS The objective of this study was to explore the perception of the legal authorities regarding different report types and visualization techniques for post-mortem radiological findings. METHODS A standardized digital questionnaire was developed and the district attorneys in the catchment area of the affiliated Forensic Institute were requested to evaluate four different types of forensic imaging reports based on four cases examples. Each case was described in four different report types (short written report only, gray-scale CT image with figure caption, color-coded CT image with figure caption, 3D-reconstruction with figure caption). The survey participants were asked to evaluate those types of reports regarding understandability, cost effectiveness and overall appropriateness for the courtroom. RESULTS AND CONCLUSION 3D reconstructions and color-coded CT images accompanied by written report were preferred regarding understandability and cost/effectiveness. 3D reconstructions of the forensic findings reviewed as most adequate for court.


European Journal of Radiology | 2012

Post-mortem virtual estimation of free abdominal blood volume

Garyfalia Ampanozi; Gary M. Hatch; Thomas D. Ruder; Patricia M. Flach; Tanja Germerott; Michael J. Thali; Lars C. Ebert

PURPOSE The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. MATERIALS AND METHODS Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). RESULTS The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. CONCLUSION Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed.


Computer Methods and Programs in Biomedicine | 2008

MARVIN: a medical research application framework based on open source software

Tobias Rudolph; Marc Puls; Christoph Anderegg; Lars C. Ebert; Martina Broehan; Adrian Rudin; Jens Kowal

This paper describes the open source framework MARVIN for rapid application development in the field of biomedical and clinical research. MARVIN applications consist of modules that can be plugged together in order to provide the functionality required for a specific experimental scenario. Application modules work on a common patient database that is used to store and organize medical data as well as derived data. MARVIN provides a flexible input/output system with support for many file formats including DICOM, various 2D image formats and surface mesh data. Furthermore, it implements an advanced visualization system and interfaces to a wide range of 3D tracking hardware. Since it uses only highly portable libraries, MARVIN applications run on Unix/Linux, Mac OS X and Microsoft Windows.

Collaboration


Dive into the Lars C. Ebert's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gary M. Hatch

University of New Mexico

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge