Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Laura A. Dempsey is active.

Publication


Featured researches published by Laura A. Dempsey.


Biomedical Optics Express | 2016

Functional imaging of the human brain using a modular, fibre-less, high-density diffuse optical tomography system

Danial Chitnis; Robert J. Cooper; Laura A. Dempsey; Samuel Powell; Simone Quaggia; David Highton; Clare E. Elwell; Jeremy C. Hebden; Nick Everdell

We present the first three-dimensional, functional images of the human brain to be obtained using a fibre-less, high-density diffuse optical tomography system. Our technology consists of independent, miniaturized, silicone-encapsulated DOT modules that can be placed directly on the scalp. Four of these modules were arranged to provide up to 128, dual-wavelength measurement channels over a scalp area of approximately 60 × 65 mm2. Using a series of motor-cortex stimulation experiments, we demonstrate that this system can obtain high-quality, continuous-wave measurements at source-detector separations ranging from 14 to 55 mm in adults, in the presence of hair. We identify robust haemodynamic response functions in 5 out of 5 subjects, and present diffuse optical tomography images that depict functional haemodynamic responses that are well-localized in all three dimensions at both the individual and group levels. This prototype modular system paves the way for a new generation of wearable, wireless, high-density optical neuroimaging technologies.


NeuroImage: Clinical | 2014

Mapping cortical haemodynamics during neonatal seizures using diffuse optical tomography: A case study

Harsimrat Singh; Robert J. Cooper; Chuen Wai Lee; Laura A. Dempsey; Andrea D. Edwards; Sabrina Brigadoi; Dimitrios Airantzis; Nick Everdell; Andrew W. Michell; David S. Holder; Jeremy C. Hebden; Topun Austin

Seizures in the newborn brain represent a major challenge to neonatal medicine. Neonatal seizures are poorly classified, under-diagnosed, difficult to treat and are associated with poor neurodevelopmental outcome. Video-EEG is the current gold-standard approach for seizure detection and monitoring. Interpreting neonatal EEG requires expertise and the impact of seizures on the developing brain remains poorly understood. In this case study we present the first ever images of the haemodynamic impact of seizures on the human infant brain, obtained using simultaneous diffuse optical tomography (DOT) and video-EEG with whole-scalp coverage. Seven discrete periods of ictal electrographic activity were observed during a 60 minute recording of an infant with hypoxic–ischaemic encephalopathy. The resulting DOT images show a remarkably consistent, high-amplitude, biphasic pattern of changes in cortical blood volume and oxygenation in response to each electrographic event. While there is spatial variation across the cortex, the dominant haemodynamic response to seizure activity consists of an initial increase in cortical blood volume prior to a large and extended decrease typically lasting several minutes. This case study demonstrates the wealth of physiologically and clinically relevant information that DOT–EEG techniques can yield. The consistency and scale of the haemodynamic responses observed here also suggest that DOT–EEG has the potential to provide improved detection of neonatal seizures.


Journal of Biomedical Optics | 2015

Data-driven approach to optimum wavelength selection for diffuse optical imaging

Laura A. Dempsey; Robert J. Cooper; Tania Roque; Teresa Correia; Elliott Magee; Samuel Powell; Adam Gibson; Jeremy C. Hebden

Abstract. The production of accurate and independent images of the changes in concentration of oxyhemoglobin and deoxyhemoglobin by diffuse optical imaging is heavily dependent on which wavelengths of near-infrared light are chosen to interrogate the target tissue. Although wavelengths can be selected by theoretical methods, in practice the accuracy of reconstructed images will be affected by wavelength-specific and system-specific factors such as laser source power and detector sensitivity. We describe the application of a data-driven approach to optimum wavelength selection for the second generation of University College London’s multichannel, time-domain optical tomography system (MONSTIR II). By performing a functional activation experiment using 12 different wavelengths between 690 and 870 nm, we were able to identify the combinations of 2, 3, and 4 wavelengths which most accurately reproduced the results obtained using all 12 wavelengths via an imaging approach. Our results show that the set of 2, 3, and 4 wavelengths which produce the most accurate images of functional activation are [770, 810], [770, 790, 850], and [730, 770, 810, 850] respectively, but also that the system is relatively robust to wavelength selection within certain limits. Although these results are specific to MONSTIR II, the approach we developed can be applied to other multispectral near-infrared spectroscopy and optical imaging systems.


Neurophotonics | 2016

Hemodynamic response to burst-suppressed and discontinuous electroencephalography activity in infants with hypoxic ischemic encephalopathy

Maria Chalia; Chuen Wai Lee; Laura A. Dempsey; Andrea D. Edwards; Harsimrat Singh; Andrew W. Michell; Nick Everdell; Reuben W. Hill; Jeremy C. Hebden; Topun Austin; Robert J. Cooper

Abstract. Burst suppression (BS) is an electroencephalographic state associated with a profound inactivation of the brain. BS and pathological discontinuous electroencephalography (EEG) are often observed in term-age infants with neurological injury and can be indicative of a poor outcome and lifelong disability. Little is known about the neurophysiological mechanisms of BS or how the condition relates to the functional state of the neonatal brain. We used simultaneous EEG and diffuse optical tomography (DOT) to investigate whether bursts of EEG activity in infants with hypoxic ischemic encephalopathy are associated with an observable cerebral hemodynamic response. We were able to identify significant changes in concentration of both oxy and deoxyhemoglobin that are temporally correlated with EEG bursts and present a relatively consistent morphology across six infants. Furthermore, DOT reveals patient-specific spatial distributions of this hemodynamic response that may be indicative of a complex pattern of cortical activation underlying discontinuous EEG activity that is not readily apparent in scalp EEG.


Biomedical Optics Express | 2015

Evaluating real-time image reconstruction in diffuse optical tomography using physiologically realistic test data.

Sabrina Brigadoi; Samuel Powell; Robert J. Cooper; Laura A. Dempsey; Simon R. Arridge; Nick Everdell; Jeremy C. Hebden; Adam Gibson

In diffuse optical tomography (DOT), real-time image reconstruction of oxy- and deoxy-haemoglobin changes occurring in the brain could give valuable information in clinical care settings. Although non-linear reconstruction techniques could provide more accurate results, their computational burden makes them unsuitable for real-time applications. Linear techniques can be employed under the assumption that the expected change in absorption is small. Several approaches exist, differing primarily in their handling of regularization and the noise statistics. In real experiments, it is impossible to compute the true noise statistics, because of the presence of physiological oscillations in the measured data. This is even more critical in real-time applications, where no off-line filtering and averaging can be performed to reduce the noise level. Therefore, many studies substitute the noise covariance matrix with the identity matrix. In this paper, we examined two questions: does using the noise model with realistic, imperfect data yield an improvement in image quality compared to using the identity matrix; and what is the difference in quality between online and offline reconstructions. Bespoke test data were created using a novel process through which simulated changes in absorption were added to real resting-state DOT data. A realistic multi-layer head model was used as the geometry for the reconstruction. Results validated our assumptions, highlighting the validity of computing the noise statistics from the measured data for online image reconstruction, which was performed at 2 Hz. Our results can be directly extended to a real application where real-time imaging is required.


Biomedical Optics Express | 2017

Geometrically complex 3D-printed phantoms for diffuse optical imaging

Laura A. Dempsey; Melissa Persad; Samuel Powell; Danial Chitnis; Jeremy C. Hebden

Tissue-equivalent phantoms that mimic the optical properties of human and animal tissues are commonly used in diffuse optical imaging research to characterize instrumentation or evaluate an image reconstruction method. Although many recipes have been produced for generating solid phantoms with specified absorption and transport scattering coefficients at visible and near-infrared wavelengths, the construction methods are generally time-consuming and are unable to create complex geometries. We present a method of generating phantoms using a standard 3D printer. A simple recipe was devised which enables printed phantoms to be produced with precisely known optical properties. To illustrate the capability of the method, we describe the creation of an anatomically accurate, tissue-equivalent premature infant head optical phantom with a hollow brain space based on MRI atlas data. A diffuse optical image of the phantom is acquired when a high contrast target is inserted into the hollow space filled with an aqueous scattering solution.


Biomedical optics | 2016

Real-time dynamic image reconstruction in time-domain diffuse optical tomography

Samuel Powell; Laura A. Dempsey; Robert J. Cooper; Adam Gibson; Jeremy C. Hebden; Simon R. Arridge

Through application of spatio-temporal regularisation techniques, we demonstrate the real-time three-dimensional dynamic reconstruction of the optical properties of a hemispherical infant head phantom, with moving absorption and scattering targets.


Advances in Experimental Medicine and Biology | 2016

Neurovascular Interactions in the Neurologically Compromised Neonatal Brain

Harsimrat Singh; Robert J. Cooper; C. W. Lee; Laura A. Dempsey; Sabrina Brigadoi; A. Edwards; D. Airantzis; Nick Everdell; A. Michell; D. Holder; T. Austin; Jc Hebden

Neurological brain injuries such as hypoxic ischaemic encephalopathy (HIE) and associated conditions such as seizures have been associated with poor developmental outcome in neonates. Our limited knowledge of the neurological and cerebrovascular processes underlying seizures limits their diagnosis and timely treatment. Diffuse optical tomography (DOT) provides haemodynamic information in the form of changes in concentration of de/oxygenated haemoglobin, which can improve our understanding of seizures and the relationship between neural and vascular processes. Using simultaneous EEG-DOT, we observed distinct haemodynamic changes which are temporally correlated with electrographic seizures. Here, we present DOT-EEG data from two neonates clinically diagnosed as HIE. Our results highlight the wealth of mutually-informative data that can be obtained using DOT-EEG techniques to understand neurovascular coupling in HIE neonates.


In: Dehghani, H and Taroni, P, (eds.) (Proceedings) Conference on Diffuse Optical Imaging V. SPIE-INT SOC OPTICAL ENGINEERING (2015) | 2015

Whole-head functional brain imaging of neonates at cot-side using time-resolved diffuse optical tomography

Laura A. Dempsey; Robert J. Cooper; Samuel Powell; Andrea D. Edwards; Chuen-Wai Lee; Sabrina Brigadoi; Nick Everdell; Simon R. Arridge; Adam Gibson; Topun Austin; Jeremy C. Hebden

We present a method for acquiring whole-head images of changes in blood volume and oxygenation from the infant brain at cot-side using time-resolved diffuse optical tomography (TR-DOT). At UCL, we have built a portable TR-DOT device, known as MONSTIR II, which is capable of obtaining a whole-head (1024 channels) image sequence in 75 seconds. Datatypes extracted from the temporal point spread functions acquired by the system allow us to determine changes in absorption and reduced scattering coefficients within the interrogated tissue. This information can then be used to define clinically relevant measures, such as oxygen saturation, as well as to reconstruct images of relative changes in tissue chromophore concentration, notably those of oxy- and deoxyhaemoglobin. Additionally, the effective temporal resolution of our system is improved with spatio-temporal regularisation implemented through a Kalman filtering approach, allowing us to image transient haemodynamic changes. By using this filtering technique with intensity and mean time-of-flight datatypes, we have reconstructed images of changes in absorption and reduced scattering coefficients in a dynamic 2D phantom. These results demonstrate that MONSTIR II is capable of resolving slow changes in tissue optical properties within volumes that are comparable to the preterm head. Following this verification study, we are progressing to imaging a 3D dynamic phantom as well as the neonatal brain at cot-side. Our current study involves scanning healthy babies to demonstrate the quality of recordings we are able to achieve in this challenging patient population, with the eventual goal of imaging functional activation and seizures.


Biomedical Optics Express | 2018

A spread spectrum approach to time-domain near-infrared diffuse optical imaging using inexpensive optical transceiver modules

Konstantinos I. Papadimitriou; Laura A. Dempsey; Jeremy C. Hebden; Simon R. Arridge; Samuel Powell

Collaboration


Dive into the Laura A. Dempsey's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nick Everdell

University College London

View shared research outputs
Top Co-Authors

Avatar

Samuel Powell

University College London

View shared research outputs
Top Co-Authors

Avatar

Harsimrat Singh

University College London

View shared research outputs
Top Co-Authors

Avatar

Topun Austin

Cambridge University Hospitals NHS Foundation Trust

View shared research outputs
Top Co-Authors

Avatar

Adam Gibson

University College London

View shared research outputs
Top Co-Authors

Avatar

Andrea D. Edwards

Cambridge University Hospitals NHS Foundation Trust

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge