Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Lawrence L.P. Wong is active.

Publication


Featured researches published by Lawrence L.P. Wong.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2011

A 32 x 32 element row-column addressed capacitive micromachined ultrasonic transducer

Andrew S. Logan; Lawrence L.P. Wong; Albert I.H. Chen; John T. W. Yeow

This paper presents characterization and initial imaging results of a 32 × 32 element two-dimensional capacitive micromachined ultrasonic transducer array. The devices are fabricated using a wafer bonding process in which both the insulation layer and the membrane are user-deposited silicon nitride. The transducers use a row-column addressing scheme to simplify the fabrication process and beamformer. By adjusting the number of rows and columns that are biased, the effective aperture of the transducer can be adjusted. This is significant because it permits imaging in the near-field of the transducer without the use of a lens. The effect on the transmit beam profile is demonstrated. The transducer has a center frequency of 5.9 MHz and a relative bandwidth of 110%. Images of horizontal and vertical wires are taken to demonstrate image resolution. A three-dimensional image of four pin heads is also demonstrated.


IEEE-ASME Transactions on Mechatronics | 2011

A 1-D Capacitive Micromachined Ultrasonic Transducer Imaging Array Fabricated With a Silicon-Nitride-Based Fusion Process

Andrew S. Logan; Lawrence L.P. Wong; John T. W. Yeow

Capacitive micromachined ultrasonic transducers (CMUTs) are an alternative to the conventional method of generating ultrasound that increases bandwidths, simplifies fabrication, and facilitates the integration with necessary electronics. We report the fabrication, characterization, and initial-phased array imaging results of a 64-element array CMUT fabricated using a fusion bonding process where both the membrane and insulation layers are user deposited silicon nitride. Individual cells have a diameter of 25 μm and a membrane thickness of 500 nm. The center frequency in immersion is 6.6 MHz with a -6 dB fractional bandwidth of 123%. A 90° phased array sector scan is made of a four-wire target using a 32-element subset of the array. Pressures in excess of 2 MPa are measured. An axial resolution of 130 μm and a lateral resolution of 0.03 rad are obtained from a wire target 15 mm away from the transducer.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2012

An FPGA-based ultrasound imaging system using capacitive micromachined ultrasonic transducers

Lawrence L.P. Wong; Albert I.H. Chen; Andrew S. Logan; John T. W. Yeow

We report the design and experimental results of a field-programmable gate array (FPGA)-based real-time ultrasound imaging system that uses a 16-element phased-array capacitive micromachined ultrasonic transducer fabricated using a fusion bonding process. The imaging system consists of the transducer, discrete analog components situated on a custom-made circuit board, the FPGA, and a monitor. The FPGA program consists of five functional blocks: a main counter, transmit and receive beamformer, receive signal pre-processing, envelope detection, and display. No dedicated digital signal processor or personal computer is required for the imaging system. An experiment is carried out to obtain the sector B-scan of a 4-wire target. The ultrasound imaging system demonstrates the possibility of an integrated system-in-a-package solution.


Ultrasonics | 2016

Capacitive micromachined ultrasonic transducers based on annular cell geometry for air-coupled applications

Shuai Na; Albert I.H. Chen; Lawrence L.P. Wong; Zhenhao Li; Mirek Macecek; John T. W. Yeow

A novel design of an air-coupled capacitive micromachined ultrasonic transducer (CMUT) with annular cell geometry (annular CMUT) is proposed. Finite element analysis shows that an annular cell has a ratio of average-to-maximum displacement (RAMD) of 0.52-0.58 which is 58-76% higher than that of a conventional circular cell. The increased RAMD leads to a larger volume displacement which results in a 48.4% improved transmit sensitivity and 127.3% improved power intensity. Single-cell annular CMUTs were fabricated with 20-μm silicon plates on 13.7-μm deep and 1.35-mm wide annular cavities using the wafer bonding technique. The measured RAMD of the fabricated CMUTs is 0.54. The resonance frequency was measured to be 94.5kHz at 170-V DC bias. The transmit sensitivity was measured to be 33.83Pa/V and 25.85Pa/V when the CMUT was excited by a continuous wave and a 20-cycle burst, respectively. The receive sensitivity at 170-V DC bias was measured to be 7.7mV/Pa for a 20-cycle burst, and 15.0mV/Pa for a continuous incident wave. The proposed annular CMUT design demonstrates a significant improvement in transmit efficiency, which is an important parameter for air-coupled ultrasonic transducers.


IEEE\/ASME Journal of Microelectromechanical Systems | 2016

Fabrication of a Curved Row–Column Addressed Capacitive Micromachined Ultrasonic Transducer Array

Albert I.H. Chen; Lawrence L.P. Wong; Shuai Na; Zhenhao Li; Mirek Macecek; John T. W. Yeow

Capacitive micromachined ultrasonic transducers (CMUTs) exhibit wide-bandwidth and can be made into tiny 2-D arrays that are integrable with electronics. A simple implementation of such 2-D array is the row-column addressed CMUT array. However, one critical limitation of a row-column array is its narrow field of view, which can be improved by curving the array. This paper reports a novel fabrication method that realizes a flexible 32 + 32 elements row-column addressed CMUT array using a two stage fabrication process. First, a functional row-column CMUT array is fabricated with a double silicon-on-insulator wafer bonding process. The second stage involves encapsulating the device with a polymer coating, yet leaving the bottom silicon substrate exposed for wet etching. The bottom buried oxide layer will also act as an etch stop layer. Pitch-catch experiments are presented to verify the functionality. Our final device, excluding the encapsulation layer, is less than 5 μm thick with a 12.8-mm × 12.8-mm aperture. The final flexible device exhibits a 4.5-MHz center frequency with a -3-dB fractional bandwidth of 82%.


Ultrasonics | 2014

A row-column addressed micromachined ultrasonic transducer array for surface scanning applications.

Lawrence L.P. Wong; Albert I.H. Chen; Zhenhao Li; Andrew S. Logan; John T. W. Yeow

Row-column addressed arrays for ultrasonic non-destructive testing (NDT) applications are analyzed and demonstrated in this paper. Simulation and experimental results of a row-column addressed 32 by 32 capacitive micromachined ultrasonic transducer (CMUT) array are presented. The CMUT array, which was designed for medical imaging applications, has a center frequency of 5.3MHz. The CMUT array was used to perform C-scans on test objects with holes that have diameters of 1.0mm and 0.5mm. The array transducer has an aperture size of 4.8mm by 4.8mm, and it was used to scan an area of 4.0mm by 4.0mm. Compared to an N by N fully addressed 2-D array, a row-column addressed array of the same number of elements requires fewer (N instead of N(2)) pairs of interconnection and supporting electronic components such as pulsers and amplifiers. Even though the resulting field of view is limit by the aperture size, row-column addressed arrays and the row-column addressing scheme can be an alternative option of 2-D arrays for NDT applications.


Journal of Micromechanics and Microengineering | 2016

Fabrication of capacitive micromachined ultrasonic transducers based on adhesive wafer bonding technique

Zhenhao Li; Lawrence L.P. Wong; Albert I.H. Chen; Shuai Na; Jame Sun; John T. W. Yeow

This paper reports the fabrication process of wafer bonded capacitive micromachined ultrasonic transducers (CMUTs) using photosensitive benzocyclobutene as a polymer adhesive. Compared with direct bonding and anodic bonding, polymer adhesive bonding provides good tolerance to wafer surface defects and contamination. In addition, the low process temperature of 250 °C is compatible with standard CMOS processes. Single-element CMUTs consisting of cells with a diameter of 46 µm and a cavity depth of 323 nm were fabricated. In-air and immersion acoustic characterizations were performed on the fabricated CMUTs, demonstrating their capability for transmitting and receiving ultrasound signals. An in-air resonance frequency of 5.47 MHz was measured by a vibrometer under a bias voltage of 300 V.


Ultrasonics | 2017

Lumped element modeling of air-coupled capacitive micromachined ultrasonic transducers with annular cell geometry

Shuai Na; Lawrence L.P. Wong; Albert I.H. Chen; Zhenhao Li; Mirek Macecek; John T. W. Yeow

HighlightsWe presented a lumped element model of air‐coupled annular‐cell CMUTs.Explicit resonance frequency and static displacement of a clamped annular plate were developed.The proposed lumped model was verified through both simulation and experimental studies.Detailed analysis of the static, frequency, and transient response was given.The proposed methodology can also be employed to study CMUTs of other cell geometries. Abstract Air‐coupled capacitive micromachined ultrasonic transducers (CMUTs) based on annular cell geometry have recently been reported. Finite element analysis and experimental studies have demonstrated their significant improvement in transmit efficiency compared with the conventional circular‐cell CMUTs. Extending the previous work, this paper proposed a lumped element model of annular‐cell CMUTs. Explicit expressions of the resonance frequency, modal vector, and static displacement of a clamped annular plate under uniform pressure were first derived based on the plate theory and curve fitting method. The lumped model of an annular CMUT cell was then developed by adopting the average displacement as the spatial variable. Using the proposed model, the ratio of average‐to‐maximum displacement was derived to be 8/15. Experimental and simulation studies on a fabricated annular CMUT cell verified the effectiveness of the lumped model. The proposed model provides an effective and efficient way to analyze and design air‐coupled annular‐cell CMUTs.


IEEE\/ASME Journal of Microelectromechanical Systems | 2017

Practical CMUT Fabrication With a Nitride-to-Oxide-Based Wafer Bonding Process

Albert I.H. Chen; Lawrence L.P. Wong; Zhenhao Li; Shuai Na; John T. W. Yeow

The introduction of wafer-bonding technique to capacitive micromachined ultrasonic transducer (CMUT) fabrication offered advantages over the surface micromachining technique, such as simplified fabrication, better membrane uniformity, and increased active area. The conventional wafer-bonding CMUT process employs silicon-on-insulator (SOI) wafers to produce the vibrating membrane layer. However, the use of SOI wafers can lead to poor membrane thickness uniformity despite the high cost. Furthermore, an additional local-oxidation (LOCOS) process should be used for SOI-based wafer bonding process to improve breakdown voltage and reduce parasitic capacitance. This paper reports a nitride-to-oxide bonding process for CMUT fabrication, designed to achieve similar results as the LOCOS-added process reported by Park et al., but without the need for SOIs and fabrication complexity. A fully functional CMUT designed for collapse-mode operation was fabricated and an immersion center frequency was measured to be 4.2 MHz with a 90% bandwidth. [2016-0210]


internaltional ultrasonics symposium | 2016

A CMUT array based on annular cell geometry for air-coupled applications

Shuai Na; Lawrence L.P. Wong; Albert I.H. Chen; Zhenhao Li; Mirek Macecek; John T. W. Yeow

An annular cell has been reported with improved transmit sensitivity over a conventional circular cell for air-coupled CMUTs. The particular geometry of an annular cell also allows multi of them to be arranged in a concentric layout such that high-intensity ultrasound can be focused in the depth direction. This paper presents a 9.3-mm-diameter CMUT array consisting of four concentric annular cells. The wafer-bonded CMUT has a plate thickness of 18.3 μm and cell width of 930 μm. Under atmospheric pressure, the ratio of average-to-maximum displacement (RAMD) of the annular cells was measured to be 0.53 using a profilometer. At 200-V DC bias and 20-Vpp AC actuation voltage, the frequency response of the maximum displacement was measured using a laser Doppler vibrometer, and a resonance frequency of 182.5 kHz was observed. At the same DC bias, the resonance frequency of the array was also measured to be 182.5 kHz using a vector network analyzer. Based on the frequency response, the acoustic filed of the CMUT array was simulated to have an 11.4-mm natural focal depth with -3-dB beam width of 3.14 mm. This study demonstrates the potential of using concentric annular-cell CMUT array to generate focused ultrasound in air.

Collaboration


Dive into the Lawrence L.P. Wong's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Shuai Na

University of Waterloo

View shared research outputs
Top Co-Authors

Avatar

Zhenhao Li

University of Waterloo

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Zhendong Sun

Chinese Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

Zhou Zheng

South China University of Technology

View shared research outputs
Top Co-Authors

Avatar

Ping Liu

Dongguan University of Technology

View shared research outputs
Top Co-Authors

Avatar

Jame Sun

University of Waterloo

View shared research outputs
Top Co-Authors

Avatar

Weijie Sun

South China University of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge