Proceedings of the National Academy of Sciences of the United States of America | 2014
Honor M. Rose; Christopher Witte; Federica Rossella; Stefan Klippel; Christian Freund; Leif Schröder
Significance The field of xenon magnetic resonance imaging (MRI) is moving closer to the development of targeted xenon biosensors for in vivo applications. It is motivated by a ca. 108-fold improved sensitivity compared with conventional proton MRI. This has been enabled by significant improvements to hardware (xenon polarizer design) and sensitivity (through the hyperpolarized 129Xe chemical exchange saturation transfer technique). In this paper, we capitalize on these improvements by demonstrating targeted xenon imaging on cells using a modular xenon biosensor. With this method, we can detect target cells with as little as 20 nM of our xenon contrast agent. Imaging of such low levels of cell-specific xenon hosts is unprecedented and reinforces the potential of xenon–cryptophane biosensors for molecular imaging applications. Magnetic resonance imaging (MRI) is seriously limited when aiming for visualization of targeted contrast agents. Images are reconstructed from the weak diamagnetic properties of the sample and require an abundant molecule like water as the reporter. Micromolar to millimolar concentrations of conventional contrast agents are needed to generate image contrast, thus excluding many molecular markers as potential targets. To address this limitation, we developed and characterized a functional xenon NMR biosensor that can identify a specific cell surface marker by targeted 129Xe MRI. Cells expressing the cell surface protein CD14 can be spatially distinguished from control cells with incorporation of as little as 20 nM of the xenon MRI readout unit, cryptophane-A. Cryptophane-A serves as a chemical host for hyperpolarized nuclei and facilitates the sensitivity enhancement achieved by xenon MRI. Although this paper describes the application of a CD14-specific biosensor, the construct has been designed in a versatile, modular fashion. This allows for quick and easy adaptation of the biosensor to any cell surface target for which there is a specific antibody. In addition, the modular design facilitates the creation of a multifunctional probe that incorporates readout modules for different detection methods, such as fluorescence, to complement the primary MRI readout. This modular antibody-based approach not only offers a practical technique with which to screen targets, but one which can be readily applied as the xenon MRI field moves closer to molecular imaging applications in vivo.
Angewandte Chemie | 2014
Stefan Klippel; Jörg Döpfert; Jabadurai Jayapaul; Martin Kunth; Federica Rossella; Matthias Schnurr; Christopher Witte; Christian Freund; Leif Schröder
Caged xenon has great potential in overcoming sensitivity limitations for solution-state NMR detection of dilute molecules. However, no application of such a system as a magnetic resonance imaging (MRI) contrast agent has yet been performed with live cells. We demonstrate MRI localization of cells labeled with caged xenon in a packed-bed bioreactor working under perfusion with hyperpolarized-xenon-saturated medium. Xenon hosts enable NMR/MRI experiments with switchable contrast and selectivity for cell-associated versus unbound cages. We present MR images with 10(3) -fold sensitivity enhancement for cell-internalized, dual-mode (fluorescence/MRI) xenon hosts at low micromolar concentrations. Our results illustrate the capability of functionalized xenon to act as a highly sensitive cell tracer for MRI detection even without signal averaging. The method will bridge the challenging gap for translation to in vivo studies for the optimization of targeted biosensors and their multiplexing applications.
Angewandte Chemie | 2015
Christopher Witte; Vera Martos; Honor May Rose; Stefan Reinke; Stefan Klippel; Leif Schröder; Christian P. R. Hackenberger
The targeting of metabolically labeled glycans with conventional MRI contrast agents has proved elusive. In this work, which further expands the utility of xenon Hyper-CEST biosensors in cell experiments, we present the first successful molecular imaging of such glycans using MRI. Xenon Hyper-CEST biosensors are a novel class of MRI contrast agents with very high sensitivity. We designed a multimodal biosensor for both fluorescent and xenon MRI detection that is targeted to metabolically labeled sialic acid through bioorthogonal chemistry. Through the use of a state of the art live-cell bioreactor, it was demonstrated that xenon MRI biosensors can be used to image cell-surface glycans at nanomolar concentrations.
Chemistry: A European Journal | 2017
Danila A. Barskiy; Aaron M. Coffey; Panayiotis Nikolaou; Dmitry M. Mikhaylov; Boyd M. Goodson; Rosa T. Branca; George J. Lu; Mikhail G. Shapiro; Igor V. Koptyug; Oleg G. Salnikov; Kirill V. Kovtunov; Valerii I. Bukhtiyarov; Matthew S. Rosen; Michael J. Barlow; Shahideh Safavi; Ian P. Hall; Leif Schröder; Eduard Y. Chekmenev
Nuclear spin polarization can be significantly increased through the process of hyperpolarization, leading to an increase in the sensitivity of nuclear magnetic resonance (NMR) experiments by 4-8 orders of magnitude. Hyperpolarized gases, unlike liquids and solids, can often be readily separated and purified from the compounds used to mediate the hyperpolarization processes. These pure hyperpolarized gases enabled many novel MRI applications including the visualization of void spaces, imaging of lung function, and remote detection. Additionally, hyperpolarized gases can be dissolved in liquids and can be used as sensitive molecular probes and reporters. This Minireview covers the fundamentals of the preparation of hyperpolarized gases and focuses on selected applications of interest to biomedicine and materials science.
Chemistry: A European Journal | 2013
Jagoda Sloniec; Matthias Schnurr; Christopher Witte; Ute Resch-Genger; Leif Schröder; Andreas Hennig
Fluorescent derivatives of the (129)Xe NMR contrast agent cryptophane-A were obtained by functionalization with near infrared fluorescent dyes DY680 and DY682. The resulting conjugates were spectrally characterized, and their interaction with giant and large unilamellar vesicles of varying phospholipid composition was analyzed by fluorescence and NMR spectroscopy. In the latter, a chemical exchange saturation transfer with hyperpolarized (129)Xe (Hyper-CEST) was used to obtain sufficient sensitivity. To determine the partitioning coefficients, we developed a method based on fluorescence resonance energy transfer from Nile Red to the membrane-bound conjugates. This indicated that not only the hydrophobicity of the conjugates, but also the phospholipid composition, largely determines the membrane incorporation. Thereby, partitioning into the liquid-crystalline phase of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine was most efficient. Fluorescence depth quenching and flip-flop assays suggest a perpendicular orientation of the conjugates to the membrane surface with negligible transversal diffusion, and that the fluorescent dyes reside in the interfacial area. The results serve as a basis to differentiate biomembranes by analyzing the Hyper-CEST signatures that are related to membrane fluidity, and pave the way for dissecting different contributions to the Hyper-CEST signal.
NMR in Biomedicine | 2013
Christopher Witte; Leif Schröder
Increasing the sensitivity of NMR experiments is an ongoing field of research to help realise the exquisite molecular specificity of this technique. Hyperpolarisation of various nuclei is a powerful approach that enables the use of NMR for molecular and cellular imaging. Substantial progress has been achieved over recent years in terms of both tracer preparation and detection schemes. This review summarises recent developments in probe design and optimised signal encoding, and promising results in sensitive disease detection and efficient therapeutic monitoring. The different methods have great potential to provide molecular specificity not available by other diagnostic modalities. Copyright
Reviews in Analytical Chemistry | 2008
Elad Harel; Leif Schröder; Shoujun Xu
Nuclear magnetic resonance (NMR) is a well-established analytical technique in chemistry. The ability to precisely control the nuclear spin interactions that give rise to the NMR phenomenon has led to revolutionary advances in fields as diverse as protein structure determination and medical diagnosis. Here, we discuss methods for increasing the sensitivity of magnetic resonance experiments, moving away from the paradigm of traditional NMR by separating the encoding and detection steps of the experiment. This added flexibility allows for diverse applications ranging from lab-on-a-chip flow imaging and biological sensors to optical detection of magnetic resonance imaging at low magnetic fields. We aim to compare and discuss various approaches for a host of problems in material science, biology, and physics that differ from the high-field methods routinely used in analytical chemistry and medical imaging.
ChemPhysChem | 2010
Franz Schilling; Leif Schröder; Krishnan K. Palaniappan; Sina Zapf; David E. Wemmer; Alexander Pines
A new approach to MRI thermometry using encapsulated hyperpolarized xenon is demonstrated. The method is based on the temperature dependent chemical shift of hyperpolarized xenon in a cryptophane-A cage. This shift is linear with a slope of 0.29 ppm °C(-1) which is perceptibly higher than the shift of the proton resonance frequency of water (ca. 0.01 ppm °C(-1)) that is currently used for MRI thermometry. Using spectroscopic imaging techniques, we collected temperature maps of a phantom sample that could discriminate by direct NMR detection between temperature differences of 0.1 °C at a sensor concentration of 150 μM. Alternatively, the xenon-in-cage chemical shift was determined by indirect detection using saturation transfer techniques (Hyper-CEST) that allow detection of nanomolar agent concentrations. Thermometry based on hyperpolarized xenon sensors improves the accuracy of currently available MRI thermometry methods, potentially giving rise to biomedical applications of biosensors functionalized for binding to specific target molecules.
Journal of Magnetic Resonance | 2010
Tyler Meldrum; Leif Schröder; Philipp Denger; David E. Wemmer; Alexander Pines
There have been many proposals to use xenon-based molecular sensors in biological settings. Fundamental to understanding the properties of these sensors in vivo is characterizing their behavior in lipid environments. We report the investigation of xenon-based molecular sensors in suspensions of lipid vesicles with a size comparable to cells. We detail spectroscopic properties of sensors associated with lipid vesicles as well as those in equilibrium in the surrounding solution. We characterize the dependence of the spectral parameters on temperature, relevant for studies at physiological temperatures. We also demonstrate the ability to perform selective saturation transfer (Hyper-CEST) between sensor, both lipid bound and unbound, and the bulk solution. Lastly, we demonstrate the applicability of saturation transfer in the heterogeneous medium as an imaging modality.
Advanced Healthcare Materials | 2015
Matthias Schnurr; Karl Sydow; Honor May Rose; Margitta Dathe; Leif Schröder
A nanoparticulate carrier system is used to efficiently deliver a contrast agent for highly sensitive xenon Hyper-CEST MRI. The carrier system not only improves the biocompatibility and solubility of the contrast agent, it also allows selective cell targeting as demonstrated by the discrimination of human brain capillary and aortic endothelial cells.