Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Léo Fradet is active.

Publication


Featured researches published by Léo Fradet.


Advances in Mechanical Engineering | 2016

Geometrical variations in white and gray matter affect the biomechanics of spinal cord injuries more than the arachnoid space

Léo Fradet; Pierre-Jean Arnoux; Virginie Callot; Yvan Petit

Traumatic spinal cord contusions lead to loss of quality of life, but their pathomechanisms are not fully understood. Previous studies have underlined the contribution of the cerebrospinal fluid in spinal cord protection. However, it remains unclear how important the contribution of the cerebrospinal fluid is relative to other factors such as the white/gray matter ratio. A finite element model of the spinal cord and surrounding morphologic features was used to investigate the spinal cord contusion mechanisms, considering subarachnoid space and white/gray matter ratio. Two vertebral segments (T6 and L1) were impacted transversely at 4.5 m s−1, which demonstrated three major results: While the presence of cerebrospinal fluid plays a significant contributory role in spinal cord protection (compression percentage decreased by up to 19%), the arachnoid space variation along the spine appears to have a limited (3% compression decrease) impact. Differences in the white and gray matter geometries from lumbar to thoracic spine levels decrease spinal cord compression by up to 14% at the thoracic level. Stress distribution in the sagittal spinal cord section was consistent with central cord syndrome, and local stress concentration on the anterior part of the spinal cord being highly reduced by the presence of cerebrospinal fluid. The use of a refined spinal cord finite element method showed that all the geometrical parameters are involved in the spinal cord contusion mechanisms. Hence, spinal cord injury criteria must be considered at each vertebral level.


Spine | 2014

Morphometrics of the entire human spinal cord and spinal canal measured from in vivo high-resolution anatomical magnetic resonance imaging.

Léo Fradet; Pierre-Jean Arnoux; Jean-Philippe Ranjeva; Yvan Petit; Virginie Callot

Study Design. Measurements of cervical and thoracolumbar human spinal cord (SC) geometry based on in vivo magnetic resonance imaging and investigation of morphological “invariants.” Objective. The current work aims at providing morphological features of the complete in vivo human normal SC and at investigating possible “invariant” parameters that may serve as normative data for individualized study of SC injuries. Summary of Background Data. Few in vivo magnetic resonance image–based studies have described human SC morphology at the cervical level, and similar description of the entire SC only relies on postmortem studies, which may be prone to atrophy biases. Moreover, large interindividual variations currently limit the use of morphological metrics as reference for clinical applications or as modeling inputs. Methods. Absolute metrics of SC (transverse and anteroposterior diameters, width of anterior and posterior horns, cross-sectional SC area, and white matter percentage) were measured using semiautomatic segmentation of high resolution in vivo T2*-weighted transverse images acquired at 3 T, at each SC level, on healthy young (N = 15) and older (N = 8) volunteers. Robustness of measurements, effects of subject, age, or sex, as well as comparison with previously published postmortem data were investigated using statistical analyses (separate analysis of variance, Tukey-HSD, Bland-Altman). Normalized-to-C3 parameters were evaluated as invariants using a leave-one-out analysis. Spinal canal parameters were measured and occupation ratio border values were determined. Results. Metrics of SC morphology showed large intra- and interindividual variations, up to 30% and 13%, respectively, on average. Sex had no influence except on posterior horn width (P < 0.01). Age-related differences were observed for anteroposterior diameter and white matter percentage (P < 0.05) and all postmortem metrics were significantly lower than in vivo values (P < 0.001). In vivo normalized SC area and diameters seemed to be invariants (R2 > 0.74, root-mean-square deviation < 10%). Finally, minimal and maximal occupation ratio were 0.2 and 0.6, respectively. Conclusion. This study presented morphological characteristics of the complete in vivo human SC. Significant differences linked to age and postmortem state have been identified. Morphological “invariants” that could be used to calculate the normally expected morphology accurately, were also identified. These observations should benefit to biomechanical and SC pathology studies. Level of Evidence: N/A


Medical & Biological Engineering & Computing | 2014

Biomechanics of thoracolumbar junction vertebral fractures from various kinematic conditions

Léo Fradet; Yvan Petit; Éric Wagnac; Carl-Eric Aubin; Pierre Jean Arnoux

Thoracolumbar spine fracture classifications are mainly based on a post-traumatic observation of fracture patterns, which is not sufficient to provide a full understanding of spinal fracture mechanisms. This study aimed to biomechanically analyze known fracture patterns and to study how they relate to fracture mechanisms. The instigation of each fracture type was computationally simulated to assess the fracture process. A refined finite element model of three vertebrae and intervertebral connective tissues was subjected to 51 different dynamic loading conditions divided into four categories: compression, shear, distraction and torsion. Fracture initiation and propagation were analyzed, and time and energy at fracture initiation were computed. To each fracture pattern described in the clinical literature were associated one or several of the simulated fracture patterns and corresponding loading conditions. When compared to each other, torsion resulted in low-energy fractures, compression and shear resulted in medium energy fractures, and distraction resulted in high-energy fractures. Increased velocity resulted in higher-energy fracture for similar loadings. The use of a finite element model provided quantitative characterization of fracture patterns occurrence complementary to clinical and experimental studies, allowing to fully understand spinal fracture biomechanics.


The International Journal of Spine Surgery | 2016

Finite Element Analysis of Sacroiliac Joint Fixation under Compression Loads

Claire Bruna-Rosso; Pierre-Jean Arnoux; Rohan-Jean Bianco; Yves Godio-Raboutet; Léo Fradet; Carl-Eric Aubin

Background Sacroiliac joint (SIJ) is a known chronic pain-generator. The last resort of treatment is the arthrodesis. Different implants allow fixation of the joint, but to date there is no tool to analyze their influence on the SIJ biomechanics under physiological loads. The objective was to develop a computational model to biomechanically analyze different parameters of the stable SIJ fixation instrumentation. Methods A comprehensive finite element model (FEM) of the pelvis was built with detailed SIJ representation. Bone and sacroiliac joint ligament material properties were calibrated against experimentally acquired load-displacement data of the SIJ. Model evaluation was performed with experimental load-displacement measurements of instrumented cadaveric SIJ. Then six fixation scenarios with one or two implants on one side with two different trajectories (proximal, distal) were simulated and assessed with the FEM under vertical compression loads. Results The simulated S1 endplate displacement reduction achieved with the fixation devices was within 3% of the experimentally measured data. Under compression loads, the uninstrumented sacrum exhibited mainly a rotation motion (nutation) of 1.38° and 2.80° respectively at 600 N and 1000 N, with a combined relative translation (0.3 mm). The instrumentation with one screw reduced the local displacement within the SIJ by up to 62.5% for the proximal trajectory vs. 15.6% for the distal trajectory. Adding a second implant had no significant additional effect. Conclusion A comprehensive finite element model was developed to assess the biomechanics of SIJ fixation. SIJ devices enable to reduce the motion, mainly rotational, between the sacrum and ilium. Positioning the implant farther from the SIJ instantaneous rotation center was an important factor to reduce the intra-articular displacement. Clinical relevance Knowledge provided by this biomechanical study enables improvement of SIJ fixation through optimal implant trajectory.


Clinical Biomechanics | 2016

Biomechanical analysis of proximal junctional failure following adult spinal instrumentation using a comprehensive hybrid modeling approach

Léo Fradet; Xiaoyu Wang; Lawrence G. Lenke; Carl-Eric Aubin

BACKGROUND Proximal junctional failure is a severe proximal junctional complication following adult spinal instrumentation and involving acute proximal junctional kyphotic deformity, mechanical failure at the upper instrumented vertebra or just above, and/or proximal junctional osseoligamentous disruption. Clinical studies have identified potential risk factors, but knowledge on their biomechanics is still lacking for addressing the proximal junctional failure issues. The objective of this study was to develop comprehensive computational modeling and simulation techniques to investigate proximal junctional failure. METHODS A 3D multibody biomechanical model based on a 47year old lumbar scoliosis surgical case that subsequently had traumatic proximal junctional failure was first developed to simulate patient-specific spinal instrumentation (from T11 to S1), compute the postoperative geometry of the instrumented spine, simulate different physiological loads and movements. Then, a highly detailed finite element model of the proximal junctional spinal segment was created using as input the geometry and displacements from the multibody model. It enabled to perform detailed stress and failure analysis across the anatomical structures. FINDINGS The simulated postoperative correction and traumatic failure (wedge fracture at upper instrumented vertebra) agreed well with the clinical report (within 2° difference). Simulated stresses around the screw threads (up to 4.7MPa) generated during the instrumentation and the buckling effect of post-operative functional loads on the proximal junctional spinal segment, were identified as potential mechanical proximal junctional failure risk factors. INTERPRETATION Overall, we demonstrated the feasibility of the developed hybrid modeling technique, which realistically allowed the simulation of the spinal instrumentation and postoperative loads, which constitutes an effective tool to further investigate proximal junctional failure pathomechanisms.


Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | 2016

Strain rate dependent behavior of the porcine spinal cord under transverse dynamic compression

Léo Fradet; Francis Cliche; Yvan Petit; Jean-Marc Mac-Thiong; Pierre-Jean Arnoux

The accurate description of the mechanical properties of spinal cord tissue benefits to clinical evaluation of spinal cord injuries and is a required input for analysis tools such as finite element models. Unfortunately, available data in the literature generally relate mechanical properties of the spinal cord under quasi-static loading conditions, which is not adapted to the study of traumatic behavior, as neurological tissue adopts a viscoelastic behavior. Thus, the objective of this study is to describe mechanical properties of the spinal cord up to mechanical damage, under dynamic loading conditions. A total of 192 porcine cervical to lumbar spinal cord samples were compressed in a transverse direction. Loading conditions included ramp tests at 0.5, 5 or 50 s−1 and cyclic loading at 1, 10 or 20 Hz. Results showed that spinal cord behavior was significantly influenced by strain rate. Mechanical damage occurred at 0.64, 0.68 and 0.73 strains for 0.5, 5 or 50 s−1 loadings, respectively. Variations of behavior between the tested strain rates were explained by cyclic loading results, which revealed behavior more or less viscous depending on strain rate. Also, a parameter (stress multiplication factor) was introduced to allow transcription of a stress–strain behavior curve to different strain rates. This factor was described and was significantly different for cervical, thoracic and lumbar vertebral heights, and for the strain rates evaluated in this study.


Spine deformity | 2018

Biomechanical Analysis of Acute Proximal Junctional Failure After Surgical Instrumentation of Adult Spinal Deformity: The Impact of Proximal Implant Type, Osteotomy Procedures, and Lumbar Lordosis Restoration*

Léo Fradet; Xiaoyu Wang; Dennis G. Crandall; Carl-Eric Aubin

STUDY DESIGN Computer biomechanical simulations to analyze risk factors of proximal junctional failure (PJF) following adult scoliosis instrumentation. OBJECTIVE To evaluate the biomechanical effects on the proximal junctional spine of the proximal implant type, tissue dissection, and lumbar lordosis (LL) restoration. PJF is a severe proximal junctional complication following adult spinal instrumentation requiring revision surgery. Potential risk factors have been reported in the literature, but knowledge on their biomechanics is still lacking to address the issues. METHODS A patient-specific multibody and finite-element hybrid modeling technique was developed for a 54-year-old patient having undergone instrumented spinal fusion for multilevel stenosis resulting in PJF. Based on the actual surgery, 30 instrumentation scenarios were derived and simulated by changing the implant type at the upper instrumented vertebra (UIV), varying the extent of proximal osteotomy and the degree of LL creation. Five functional loads were simulated, and stresses and strains were analyzed for each of the 30 tested scenarios. RESULTS There was 80% more trabecular bone with stress greater than 0.5 MPa in the UIV with screws compared to hooks. Hooks allowed 96% more mobility of the proximal instrumented functional unit compared to screws. The bilateral complete facetectomy along with posterior ligaments dissection caused a significant increase of the range of motion of the functional unit above the UIV. LL creation increased the flexion moment applied on the proximal vertebra from 7.5 to 17.5 Nm, which generated damage at the bone-screw interface that affected the screw purchase. CONCLUSION Using hooks at UIV and reducing posterior proximal spinal element dissection lowered stress levels in the proximal junctional spinal segment and thus reduced the biomechanical risks of PJF. LL restoration was associated with increased stress levels in postoperative functional upper body flexion.STUDY DESIGN Computer biomechanical simulations to analyze risk factors of proximal junctional failure (PJF) following adult scoliosis instrumentation. OBJECTIVE To evaluate the biomechanical effects on the proximal junctional spine of the proximal implant type, tissue dissection, and lumbar lordosis (LL) restoration. SUMMARY OF BACKGROUND DATA PJF is a severe proximal junctional complication following adult spinal instrumentation requiring revision surgery. Potential risk factors have been reported in the literature, but knowledge on their biomechanics is still lacking to address the issues. METHODS A patient-specific multibody and finite-element hybrid modeling technique was developed for a 54-year-old patient having undergone instrumented spinal fusion for multilevel stenosis resulting in PJF. Based on the actual surgery, 30 instrumentation scenarios were derived and simulated by changing the implant type at the upper instrumented vertebra (UIV), varying the extent of proximal osteotomy and the degree of LL creation. Five functional loads were simulated, and stresses and strains were analyzed for each of the 30 tested scenarios. RESULTS There was 80% more trabecular bone with stress greater than 0.5 MPa in the UIV with screws compared to hooks. Hooks allowed 96% more mobility of the proximal instrumented functional unit compared to screws. The bilateral complete facetectomy along with posterior ligaments dissection caused a significant increase of the range of motion of the functional unit above the UIV. LL creation increased the flexion moment applied on the proximal vertebra from 7.5 to 17.5 Nm, which generated damage at the bone-screw interface that affected the screw purchase. CONCLUSION Using hooks at UIV and reducing posterior proximal spinal element dissection lowered stress levels in the proximal junctional spinal segment and thus reduced the biomechanical risks of PJF. LL restoration was associated with increased stress levels in postoperative functional upper body flexion.


Computer Methods in Biomechanics and Biomedical Engineering | 2013

Prediction of bone anisotropic mechanical properties in osteoporotic human vertebral body from microstructural parameters

Léo Fradet; A. Vachon; A. Levasseur; Pierre-Jean Arnoux; Yvan Petit

Microstructural (Keller et al. 1992) and mechanical (Keaveny and Hayes 1993) properties and anisotropy of trabecular bone have been widely documented in the literature. Both structural and mechanical properties are known to be influenced by age through progression of osteoporosis. The objective of this studywas to find the best prediction model for anisotropic mechanical properties of osteoporotic vertebral trabecular bone based on microstructural parameters. This model will then be used to compare structural anisotropy (SA) and mechanical anisotropy (MA).


22nd Congress of the European Society of Biomechanics | 2016

Assessing mechanical and structural damage in cervical spondylotic myelopathy with FE analysis and multi-parametric MRI

Manuel Taso; Virginie Callot; Léo Fradet; Arnaud Le Troter; Jean-Philippe Ranjeva; Kathia Chaumoitre; Pierre-Hugues Roche; Pierre-Jean Arnoux


Computer Methods in Biomechanics and Biomedical Engineering | 2015

Anteroposterior compression of the spinal cord leading to cervical myelopathy: a finite element analysis.

Manuel Taso; Léo Fradet; Virginie Callot; Pierre-Jean Arnoux

Collaboration


Dive into the Léo Fradet's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yvan Petit

École de technologie supérieure

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Carl-Eric Aubin

École Polytechnique de Montréal

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A. Levasseur

Université de Montréal

View shared research outputs
Top Co-Authors

Avatar

Xiaoyu Wang

École Polytechnique de Montréal

View shared research outputs
Top Co-Authors

Avatar

Éric Wagnac

École de technologie supérieure

View shared research outputs
Top Co-Authors

Avatar

Claire Bruna-Rosso

École Polytechnique de Montréal

View shared research outputs
Top Co-Authors

Avatar

Francis Cliche

École de technologie supérieure

View shared research outputs
Researchain Logo
Decentralizing Knowledge