Leonardo Foti
Oswaldo Cruz Foundation
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Leonardo Foti.
Memorias Do Instituto Oswaldo Cruz | 2009
Leonardo Foti; Bruna de Paula Fonseca e Fonseca; Lílian Dias Nascimento; Christiane de Fátima Silva Marques; Edmilson Domingos da Silva; Cesar A. B. Duarte; Christian Macagnan Probst; Samuel Goldenberg; Antônio Gomes Pinto; Marco A. Krieger
A new multiplex assay platform was evaluated to detect Trypanosoma cruzi infection using the recombinant antigens CRA, FRA, CRAFRA fusion and parasite lysate. The antigens presented different sensitivity and specificity in a singleplex test when compared to a serial dilution of two pools comprising 10 positive serum samples and one pool of 10 negative samples. The recombinant protein CRA presented lower sensitivity (55%) in contrast to the 100% specificity and sensitivity of FRA, CRAFRA and T. cruzi lysate. These antigens also showed good results in a duplex test and the duplex test with CRAFRA/T. cruzi lysate showed better performance with 100% specificity and sensitivity, as well as a lower cut-off value in comparison to the other duplex test, FRA/T. cruzi lysate. Hence, when the antigens were used in duplex format, both tests showed decreased cut-off values and no interference between different bead sets, resulting in increasing sensitivity and specificity. The results of these multiplex tests show that they could be an alternative to singleplex detection for Chagas disease, and also indicate the necessity of using multiplex diagnostic tools to increase the sensitivity and specificity for diagnostic tests. Emerging data from the T. cruzi genome and from its ORFeome project will also allow the identification of new antigens for this disease detection application.
Clinical and Vaccine Immunology | 2011
Bruna de Paula Fonseca e Fonseca; Christiane de Fátima Silva Marques; Lílian Dias Nascimento; Marcelle Bral de Mello; Leila Botelho Rodrigues da Silva; Nara Mazarakis Rubim; Leonardo Foti; Edimilson Domingos da Silva; Antonio G. P. Ferreira; Marco A. Krieger
ABSTRACT Hepatitis C virus (HCV) infection is a major burden to public health worldwide, affecting approximately 3% of the human population. Although HCV detection is currently based on reliable tests, the field of medical diagnostics has a growing need for inexpensive, accurate, and quick high-throughput assays. By using the recombinant HCV antigens NS3, NS4, NS5, and Combined, we describe a new bead-based multiplex test capable of detecting HCV infection in human serum samples. The first analysis, made in a singleplex format, showed that each antigen coupled to an individual bead set presented high-level responses for anti-HCV-positive reference serum pools and lower-level responses for the HCV-negative pools. Our next approach was to determine the sensitivity and specificity of each antigen by testing 93 HCV-positive and 93 HCV-negative sera. When assayed in the singleplex format, the NS3, NS4, and NS5 antigens presented lower sensitivity values (50.5%, 51.6%, and 55.9%, respectively) than did the Combined antigen, which presented a sensitivity of 93.5%. All antigens presented 100% specificity. These antigens were then multiplexed in a 4-plex assay, which resulted in increased sensitivity and specificity values, performing with 100% sensitivity and 100% specificity. The positive and negative predictive values for the 4-plex assay were 100%. Although preliminary, this 4-plex assay showed robust results that, aligned with its small-sample-volume requirements and also its cost- and time-effectiveness, make it a reasonable alternative to tests currently used for HCV screening of potentially infected individuals.
PLOS ONE | 2010
Cesar A. B. Duarte; Leonardo Foti; Sueli M. Nakatani; Irina Nastassja Riediger; Celina de Oliveira Poersch; Daniela Parada Pavoni; Marco A. Krieger
The strategy used to treat HCV infection depends on the genotype involved. An accurate and reliable genotyping method is therefore of paramount importance. We describe here, for the first time, the use of a liquid microarray for HCV genotyping. This liquid microarray is based on the 5′UTR — the most highly conserved region of HCV — and the variable region NS5B sequence. The simultaneous genotyping of two regions can be used to confirm findings and should detect inter-genotypic recombination. Plasma samples from 78 patients infected with viruses with genotypes and subtypes determined in the Versant™ HCV Genotype Assay LiPA (version I; Siemens Medical Solutions, Diagnostics Division, Fernwald, Germany) were tested with our new liquid microarray method. This method successfully determined the genotypes of 74 of the 78 samples previously genotyped in the Versant™ HCV Genotype Assay LiPA (74/78, 95%). The concordance between the two methods was 100% for genotype determination (74/74). At the subtype level, all 3a and 2b samples gave identical results with both methods (17/17 and 7/7, respectively). Two 2c samples were correctly identified by microarray, but could only be determined to the genotype level with the Versant™ HCV assay. Genotype “1” subtypes (1a and 1b) were correctly identified by the Versant™ HCV assay and the microarray in 68% and 40% of cases, respectively. No genotype discordance was found for any sample. HCV was successfully genotyped with both methods, and this is of prime importance for treatment planning. Liquid microarray assays may therefore be added to the list of methods suitable for HCV genotyping. It provides comparable results and may readily be adapted for the detection of other viruses frequently co-infecting HCV patients. Liquid array technology is thus a reliable and promising platform for HCV genotyping.
PLOS ONE | 2016
Fred Luciano Neves Santos; Paola Alejandra Fiorani Celedon; Nilson Ivo Tonin Zanchin; Tatiana de Arruda Campos Brasil; Leonardo Foti; Wayner Vieira de Souza; Edmilson Domingos da Silva; Yara de Miranda Gomes; Marco A. Krieger
The performance of serologic tests in chronic Chagas disease diagnosis largely depends on the type and quality of the antigen preparations that are used for detection of anti-Trypanosoma cruzi antibodies. Whole-cell T. cruzi extracts or recombinant proteins have shown variation in the performance and cross-reactivity. Synthetic chimeric proteins comprising fragments of repetitive amino acids of several different proteins have been shown to improve assay performances to detect Chagasic infections. Here, we describe the production of four chimeric T. cruzi proteins and the assessment of their performance for diagnostic purposes. Circular Dichroism spectra indicated the absence of well-defined secondary structures, while polydispersity evaluated by Dynamic Light Scattering revealed only minor aggregates in 50 mM carbonate-bicarbonate (pH 9.6), demonstrating that it is an appropriate buffering system for sensitizing microplates. Serum samples from T. cruzi-infected and non-infected individuals were used to assess the performance of these antigens for detecting antibodies against T. cruzi, using both enzyme-linked immunosorbent assay and a liquid bead array platform. Performance parameters (AUC, sensitivity, specificity, accuracy and J index) showed high diagnostic accuracy for all chimeric proteins for detection of specific anti-T. cruzi antibodies and differentiated seropositive individuals from those who were seronegative. Our data suggest that these four chimeric proteins are eligible for phase II studies.
PLOS Neglected Tropical Diseases | 2017
Fred Luciano Neves Santos; Paola Alejandra Fiorani Celedon; Nilson Ivo Tonin Zanchin; Wayner Vieira de Souza; Edimilson Domingos da Silva; Leonardo Foti; Marco Aurélio Krieger; Yara de Miranda Gomes
Background The performance of current serologic tests for diagnosing chronic Chagas disease (CD) is highly variable. The search for new diagnostic markers has been a constant challenge for improving accuracy and reducing the number of inconclusive results. Methodology/Principal findings Here, four chimeric proteins (IBMP-8.1 to -8.4) comprising immunodominant regions of different Trypanosoma cruzi antigens were tested by enzyme-linked immunosorbent assay. The proteins were used to detect specific anti-T. cruzi antibodies in the sera of 857 chagasic and 689 non-chagasic individuals to evaluate their accuracy for chronic CD diagnosis. The antigens were recombinantly expressed in Escherichia coli and purified by chromatographic methods. The sensitivity and specificity values ranged from 94.3% to 99.3% and 99.4% to 100%, respectively. The diagnostic odds ratio (DOR) values were 6,462 for IBMP-8.1, 3,807 for IBMP-8.2, 32,095 for IBMP-8.3, and 283,714 for IBMP-8.4. These chimeric antigens presented DORs that were higher than the commercial test Pathozyme Chagas. The antigens IBMP-8.3 and -8.4 also showed DORs higher than the Gold ELISA Chagas test. Mixtures with equimolar concentrations were tested in order to improve the diagnosis accuracy of negative samples with high signal and positive samples with low signal. However, no gain in accuracy was observed relative to the individual antigens. A total of 1,079 additional sera were used to test cross-reactivity to unrelated diseases. The cross-reactivity rates ranged from 0.37% to 0.74% even for Leishmania spp., a pathogen showing relatively high genome sequence identity to T. cruzi. Imprecision analyses showed that IBMP chimeras are very stable and the results are highly reproducible. Conclusions/Significance Our findings indicate that the IBMP-8.4 antigen can be safely used in serological tests for T. cruzi screening in blood banks and for chronic CD laboratory diagnosis.
Journal of Immunological Methods | 2016
Sandra Crestani; Amanda Leitolis; Lucianna Freitas Oliveira Lima; Marco A. Krieger; Leonardo Foti
Diverse techniques have been developed to analyze antibody-mediated responses to infections. However, the most common tests, i.e., enzyme-linked immunosorbent assays, require separate reactions for each antigen and consequently necessitate large sample volumes. Luminex technology allows the detection of multiple antibodies in a single experiment, but nonspecific binding can impair the results. Therefore, we examined the use of Escherichia coli lysates to reduce nonspecific binding and improve the results of liquid microarrays based on Luminex technology. Anti-bacteria antibodies were detected in human serum samples, as evidenced by high median fluorescence intensity (MFI) in assays performed with paramagnetic microspheres coupled with E. coli lysates. Moreover, the addition of an E. coli lysate as a blocker reduced the nonspecific binding of antigens produced by E. coli in a concentration-dependent manner. Tris-HCl reduced MFI values in negative samples, but did not affect MFI for positive samples. For microspheres coupled with different antigens, an E. coli lysate blocker significantly improved the fluorescence signals from positive samples. The addition of Tris-HCl and the E. coli lysate induced antigen-specific differences in MFI. This combination of the E. coli lysate blocker and Tris-HCl yielded a statistically significant improvement in MFI in the assays for Chagas disease and hepatitis C virus samples. However, for the Treponema pallidum p47 antigen improvement in MFI was only observed for the preparation with the E. coli blocker at a concentration of 3%. In conclusion, the addition of an E. coli lysate and Tris-HCl to the microarray assay reduced the nonspecific binding of human anti-bacteria antibodies and, therefore, increased the specific MFI.
Journal of Materials Chemistry B | 2016
B. M. Serafim; A. Leitolis; S. Crestani; B. H. Marcon; Leonardo Foti; Cesar Liberato Petzhold; C. Radtke; M. A. Krieger; Cyro Ketzer Saul
This work presents an Electrospray Induced Surface Activation (EISA) method generalization for electrospinning. It allows an easy way to produce surface functionalized microfiber mats for infectious disease diagnostic purposes. We present the details of both the production and characterization of surface functionalized highly porous poly methyl methacrylate (PMMA) microfiber mats produced using dry (DS) and wet substrate (WS) configurations. The characterization was performed using high-resolution scanning electron microscopy (HRSEM), Size Exclusion Chromatography (SEC), X-ray photoelectron spectroscopy (XPS) and biological essays attaching both the recombinant auto-fluorescent green fluorescent protein (GFP) and the anti-human Ig protein containing a fluorescent reporter R-phycoerythrin (AbPE). The final biological application assay was performed by positively detecting HIV contaminated human samples.
Memorias Do Instituto Oswaldo Cruz | 2017
Priscila T Baschirotto; Marco A. Krieger; Leonardo Foti
BACKGROUND During pregnancy, toxoplasmosis and rubella can cause serious damage to the mother and the foetus through vertical transmission. Early diagnosis enables implementation of health measures aimed at preventing vertical transmission and minimising damage caused by these diseases. OBJECTIVE Here, we report the development of a multiplex assay for simultaneous detection of IgG antibodies produced during toxoplasmosis and rubella infection. METHODS This assay is based on xMap technology. Initially, by singleplex assays, we evaluated the following antigens: one Toxoplasma gondii lysate; two antigenic extracts of T. gondii (TOX8131 and TOX8122); fragments of T. gondii antigens [SAG-1 (amino acids 45-198), GRA-7 (24-100), GRA-1 (57-149), ROP-4, and MIC-3 (234-306)]; two chimeric antigens composed of fragments of SAG-1, GRA-7, and P35 (CTOX and CTOXH); and fragments of Rubella virus antigens [E-1 (157-176, 213-239, 374-390), E-2 (31-105), and C (1-123)]. FINDINGS A multiplex assay to simultaneously diagnose toxoplasmosis and rubella was designed with the best-performing antigens in singleplex and multiplex assays, which included CTOXH, T. gondii lysate, TOX8131, E-1, and E-2. The multiplex assay showed 100% sensitivity and specificity for anti-T. gondii IgG detection and 95.6% sensitivity and 100% specificity for anti-R. virus IgG detection. MAIN CONCLUSIONS We found that, despite the difficulties related to developing multiplex systems, different types of antigens (extracts and recombinant proteins) can be used to develop high-performance diagnostic tests. The assay developed is suitable to screen for prior T. gondii and R. virus infections, because it is a rapid, high-throughput, low-cost alternative to the current standard diagnostic tools, which require multiple individual tests.
Journal of Clinical Microbiology | 2017
Fred Luciano Neves Santos; Paola Alejandra Fiorani Celedon; Nilson Ivo Tonin Zanchin; Amanda Leitolis; Sandra Crestani; Leonardo Foti; Wayner Vieira de Souza; Yara de Miranda Gomes; Marco A. Krieger
ABSTRACT Diagnosing chronic Chagas disease (CD) requires antibody–antigen detection methods, which are traditionally based on enzymatic assay techniques whose performance depend on the type and quality of antigen used. Previously, 4 recombinant chimeric proteins from the Instituto de Biologia Molecular do Paraná (IBMP-8.1 to 8.4) comprising immuno-dominant regions of diverse Trypanosoma cruzi antigens showed excellent diagnostic performance in enzyme-linked immunosorbent assays. Considering that next-generation platforms offer improved CD diagnostic accuracy with different T. cruzi-specific recombinant antigens, we assessed the performance of these chimeras in liquid microarrays (LMAs). The chimeric proteins were expressed in Escherichia coli and purified by chromatography. Sera from 653 chagasic and 680 healthy individuals were used to assess the performance of these chimeras in detecting specific anti-T. cruzi antibodies. Accuracies ranged from 98.1 to 99.3%, and diagnostic odds ratio values were 3,548 for IBMP-8.3, 4,826 for IBMP-8.1, 7,882 for IBMP-8.2, and 25,000 for IBMP-8.4. A separate sera bank (851 samples) was employed to assess cross-reactivity with other tropical diseases. Leishmania, a pathogen with high similarity to T. cruzi, showed cross-reactivity rates ranging from 0 to 2.17%. Inconclusive results were negligible (0 to 0.71%). Bland–Altman and Deming regression analysis based on 200 randomly selected CD-positive and negative samples demonstrated interchangeability with respect to CD diagnostic performance in both singleplex and multiplex assays. Our results suggested that these chimeras can potentially replace antigens currently used in commercially available assay kits. Moreover, the use of multiplex platforms, such as LMA assays employing 2 or more IBMP antigens, would abrogate the need for 2 different testing techniques when diagnosing CD.
Biochemical and Biophysical Research Communications | 2004
Patricia Alves Mörking; Bruno Dallagiovanna; Leonardo Foti; Beatriz Garat; Gisele Fernanda Assine Picchi; Adriana Castilhos Souza Umaki; Christian M. Probst; Marco A. Krieger; Samuel Goldenberg; Stenio Perdigão Fragoso