Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Leonardo Puppulin is active.

Publication


Featured researches published by Leonardo Puppulin.


Acta Biomaterialia | 2010

Raman tensor analysis of ultra-high molecular weight polyethylene and its application to study retrieved hip joint components

Yasuhito Takahashi; Leonardo Puppulin; Wenliang Zhu; Giuseppe Pezzotti

The angular dependences of the polarized Raman intensity of A(g), B(1g), B(2g), and B(3g) modes have been preliminary investigated on a model fiber sample of ultra-high molecular weight polyethylene (UHMWPE) in order to retrieve the Raman tensor elements, i.e. the intrinsic parameters governing the vibrational behavior of the orthorhombic structure of polyethylene. Based on this Raman analysis, a method is proposed for determining unknown crystallographic orientation patterns in UHMWPE biomedical components concurrently with the orientation distribution functions for orthorhombic lamellae. An application of the method is shown, in which we quantitatively examined the molecular orientation patterns developed on the surface of four in vivo exposed UHMWPE acetabular cups vs. an unused cup. Interesting findings were: (i) a clear bimodal distribution of orientation angles was observed on worn surfaces; and (ii) a definite and systematic increase in both molecular orientation and crystallinity in main wear zones vs. non-wear zones was found in all retrieved acetabular cups. The present crystallographic analysis is an extension of our previous Raman studies of UHMWPE acetabular cups related to assessments of oxidation and residual strain and suggests a viable path to track back wear-history information from the surface of UHMWPE, thus unfolding the in vivo kinematics of the bearing surfaces in hip joints on the microscopic scale.


Journal of Biomedical Optics | 2007

Confocal Raman spectroscopic analysis of cross-linked ultra-high molecular weight polyethylene for application in artificial hip joints

Giuseppe Pezzotti; Tsuyoshi Kumakura; Kiyotaka Yamada; Toshiyuki Tateiwa; Leonardo Puppulin; Wenliang Zhu; Kengo Yamamoto

Confocal spectroscopic techniques are applied to selected Raman bands to study the microscopic features of acetabular cups made of ultra-high molecular weight polyethylene (UHMWPE) before and after implantation in vivo. The micrometric lateral resolution of a laser beam focused on the polymeric surface (or subsurface) enables a highly resolved visualization of 2-D conformational population patterns, including crystalline, amorphous, orthorhombic phase fractions, and oxidation index. An optimized confocal probe configuration, aided by a computational deconvolution of the optical probe, allows minimization of the probe size along the in-depth direction and a nondestructive evaluation of microstructural properties along the material subsurface. Computational deconvolution is also attempted, based on an experimental assessment of the probe response function of the polyethylene Raman spectrum, according to a defocusing technique. A statistical set of high-resolution microstructural data are collected on a fully 3-D level on gamma-ray irradiated UHMWPE acetabular cups both as-received from the maker and after retrieval from a human body. Microstructural properties reveal significant gradients along the immediate material subsurface and distinct differences are found due to the loading history in vivo, which cannot be revealed by conventional optical spectroscopy. The applicability of the confocal spectroscopic technique is valid beyond the particular retrieval cases examined in this study, and can be easily extended to evaluate in-vitro tested components or to quality control of new polyethylene brands. Confocal Raman spectroscopy may also contribute to rationalize the complex effects of gamma-ray irradiation on the surface of medical grade UHMWPE for total joint replacement and, ultimately, to predict their actual lifetime in vivo.


Journal of Biomaterials Science-polymer Edition | 2009

In-Depth Oxidation and Strain Profiles in UHMWPE Acetabular Cups Non-Destructively Studied by Confocal Raman Microprobe Spectroscopy

Tsuyoshi Kumakura; Leonardo Puppulin; Kengo Yamamoto; Yasuhito Takahashi; Giuseppe Pezzotti

Raman spectroscopy is used for the characterization of the two main mechanisms responsible for the degradation of acetabular cups in hip joints: creep deformation and oxidation. The term creep refers to the permanent deformation that occurs under the effect of body weight and does not completely recover after load release. This mechanism involves no mass loss from the sample, but packing and adjustment of the polyethylene molecules in their reciprocal positions under pressure. Conversely, oxidation triggers wear, which is accompanied by irreversible mass loss from the material: surface molecules of the polyethylene body oxidize, delaminate and are progressively peeled off, involving volumetric changes and resulting in debris formation. Both degradation mechanisms negatively interact and converge toward cup loosening, which requires revision surgery. In this paper, we show that confocal Raman spectroscopy can be used to separate the contributions to the dimensional change observed in acetabular cups arising from creep and from wear. Raman measurements are completely non-destructive and contactless, and can guide surgeons and materials technologists to optimize surface treatments and molecular structure of polyethylene cups, thus maximizing their in vivo lifetime.


Langmuir | 2016

Silicon Nitride Bioceramics Induce Chemically Driven Lysis in Porphyromonas gingivalis

Giuseppe Pezzotti; Ryan M. Bock; Bryan J. McEntire; Erin N. Jones; Marco Boffelli; Wenliang Zhu; Greta Baggio; Francesco Boschetto; Leonardo Puppulin; Tetsuya Adachi; Toshiro Yamamoto; Narisato Kanamura; Yoshinori Marunaka; B. Sonny Bal

Organisms of Gram-negative phylum bacteroidetes, Porphyromonas gingivalis, underwent lysis on polished surfaces of silicon nitride (Si3N4) bioceramics. The antibacterial activity of Si3N4 was mainly the result of chemically driven principles. The lytic activity, although not osmotic in nature, was related to the peculiar pH-dependent surface chemistry of Si3N4. A buffering effect via the formation of ammonium ions (NH4(+)) (and their modifications) was experimentally observed by pH microscopy. Lysis was confirmed by conventional fluorescence spectroscopy, and the bacterias metabolism was traced with the aid of in situ Raman microprobe spectroscopy. This latter technique revealed the formation of peroxynitrite within the bacterium itself. Degradation of the bacterias nucleic acid, drastic reduction in phenilalanine, and reduction of lipid concentration were observed due to short-term exposure (6 days) to Si3N4. Altering the surface chemistry of Si3N4 by either chemical etching or thermal oxidation influenced peroxynitrite formation and affected bacteria metabolism in different ways. Exploiting the peculiar surface chemistry of Si3N4 bioceramics could be helpful in counteracting Porphyromonas gingivalis in an alkaline pH environment.


Journal of The Mechanical Behavior of Biomedical Materials | 2016

Chemically driven tetragonal-to-monoclinic polymorphic transformation in retrieved ZTA femoral heads from dual mobility hip implants.

Marco Boffelli; A. Doimo; Elia Marin; Leonardo Puppulin; Wenliang Zhu; Nobuhiko Sugano; I.C. Clarke; Giuseppe Pezzotti

Two short-term (two and nine months) retrieved zirconia-toughened alumina (ZTA) femoral heads and nine pristine femoral heads from the same manufacturer have been investigated with respect to their surface stability by means of confocal Raman spectroscopy. Quantitative estimations of monoclinic volume fraction have been carried out in both non-wear and main wear zones of the retrieved heads, which invariantly showed high volume fractions of monoclinic polymorph. In-depth (sub-surface) profiles, non-destructively collected in the main wear zones with the Raman probe in confocal configuration, indeed confirmed that polymorphic transformation was extended down to 100μm below the bearing surface of the femoral heads. Acceleration of tetragonal-to-monoclinic transformation rate leads to unexpectedly high fractions of monoclinic phase within very short-term in-vivo exposures. Phase transformation in-vivo is much more marked than what one could actually predict according to simply simulating a hydrothermal environment in-vitro and could not be simply ascribed to the mechanical stress fields generated during normal service at the bearing surface. Instead, the chemical consequences of metal contamination on the ZTA femoral head surface are shown to play the most detrimental role in phase destabilization.


Journal of Biomaterials Science-polymer Edition | 2011

Non-destructively differentiating the roles of creep, wear and oxidation in long-term in vivo exposed polyethylene cups.

Giuseppe Pezzotti; Yasuhito Takahashi; Seita Takamatsu; Leonardo Puppulin; Takashi Nishii; Hidenobu Miki; Nobuhiko Sugano

Wear of polyethylene acetabular cups in patients of total hip arthroplasty is routinely deduced from the penetration of the femoral head into the acetabular liner as observed in the radiographs. However, the linear penetration thus measured represents the cumulative contribution of two components, one due to wear, and the other due to creep or irreversible deformation of the polyethylene structure. The erroneous attribution to wear of the entire penetration displacement of the head in the cup might lead to misinterpretation of the actual performance of acetabular cups. The aim of this study was to quantify the head displacement components due to wear and to creep, as they occur in vivo in acetabular cups, and to relate them to the oxidation state of the material by means of advanced Raman spectroscopy procedures. Throughout the investigation, we compared the behaviors on the molecular scale of acetabular cups subjected to different sterilization methods (i.e., γ-irradiation and ethylene oxide treatment).


Scientific Reports | 2016

Silicon Nitride: A Synthetic Mineral for Vertebrate Biology

Giuseppe Pezzotti; Bryan J. McEntire; Ryan M. Bock; Marco Boffelli; Wenliang Zhu; Eleonora Vitale; Leonardo Puppulin; Tetsuya Adachi; Toshiro Yamamoto; Narisato Kanamura; B. Sonny Bal

The remarkable stoichiometric flexibility of hydroxyapatite (HAp) enables the formation of a variety of charged structural sites at the material’s surface which facilitates bone remodeling due to binding of biomolecule moieties in zwitterionic fashion. In this paper, we report for the first time that an optimized biomedical grade silicon nitride (Si3N4) demonstrated cell adhesion and improved osteoconductivity comparable to highly defective, non-stoichiometric natural hydroxyapatite. Si3N4’s zwitterionic-like behavior is a function of the dualism between positive and negative charged off-stoichiometric sites (i.e., N-vacancies versus silanols groups, respectively). Lattice defects at the biomaterial’s surface greatly promote interaction with positively- and negatively-charged functional groups in biomolecules, and result in the biologically effective characteristics of silicon nitride. These findings are anticipated to be a starting point for further discoveries of therapeutic bone-graft substitute materials.


Acta Biomaterialia | 2011

Polarized Raman analysis of the molecular rearrangement and residual strain on the surface of retrieved polyethylene tibial plates

Leonardo Puppulin; Yasuhito Takahashi; Wenliang Zhu; Nobuhiko Sugano; Giuseppe Pezzotti

The response to applied strain of EtO-sterilized and γ-irradiated polyethylene materials belonging to tibial inserts has been studied by polarized Raman spectroscopy. Initial calibrations on as-received samples from three different makers were employed to clarify the rearrangement of molecular chains under strain, expressed in terms of Euler angular displacements in space and orientation distribution functions. This body of information was then applied to a quantitative analysis of four tibial inserts (from the same three makers of the unused samples) retrieved after in vivo exposures ranging between 7 months and 5 years 8 months. The main results of the Raman analysis can be summarized as follows: (i) γ-irradiated samples experienced lower texturing on the molecular scale compared to EtO-sterilized samples, likely due to a higher strain recovery capability; and (ii) independent of sterilization method, the amount of plastic strain was mainly developed early after in vivo implantation, whereby out-of-plane molecules rotated under load onto planes parallel to the sample surface until saturation of angular displacements was reached.


Journal of The Mechanical Behavior of Biomedical Materials | 2014

In situ measurements of local temperature and contact stress magnitude during wear of ceramic-on-ceramic hip joints.

Wenliang Zhu; Leonardo Puppulin; Andrea Leto; Yasuhito Takahashi; Nobuhiko Sugano; Giuseppe Pezzotti

Fluorescence microprobe spectroscopy was applied to in situ assessments of contact stress and local temperature at the contact point of dry-sliding couples during wear tests of two commercially available ceramic-on-ceramic femoral heads. The investigated ceramic hip implants consisted of either monolithic Al2O3 or Al2O3/ZrO2 composite. A specially designed pin-on-ball tribometer was employed, which enabled directly testing the femoral head components as received from the maker without further manipulation. The strong fluorescence emission from Cr(3+) impurities contained in Al2O3 served as a responsive sensor for both temperature and stress. Analytical corrections for the averaging effects arising from the finite size of the laser probe were made according to a probe response formalism in which geometrical conditions of the sliding couple were incorporated as boundary conditions. The sample-probe interaction at the contact point was then experimentally calibrated by obtaining probe response functions for the two materials investigated. Based on such theoretical and experimental procedures, deconvolutive computational routines could be set up and the true variations of local temperature and stress at the contact point of the bearing surfaces retrieved from the observed time-dependent broadening and shift of a selected spectral band, respectively. The main result of the in situ investigation was that the monolithic sliding couple showed both significantly lower temperature and lower magnitude of compressive stress at the contact point as compared to the composite one, although the composite couple wore at a significantly lower specific wear rate than the monolithic one.


Journal of The Mechanical Behavior of Biomedical Materials | 2014

Innovative tribometer for in situ spectroscopic analyses of wear mechanisms and phase transformation in ceramic femoral heads.

Leonardo Puppulin; Andrea Leto; Zhu Wenliang; Nobuhiko Sugano; Giuseppe Pezzotti

The literature on tribological assessments of artificial hip joints usually focuses on correlations between joint composition, size, and specific wear rates, but conspicuously ignores the physical aspects behind the occurrence of degradation mechanisms of friction and wear. Surface degradation in artificial joints occurs because of increases in temperature and local exacerbation of contact stresses inside the moving contact as a consequence of physical and chemical modifications of the sliding surfaces. This article reports about the development of a new pin-on-ball spectroscopy-assisted tribometer device that enables investigating also physical rather than merely engineering aspects of wear processes using in situ Raman and fluorescence techniques. This innovative tribometer is designed to bring about, in addition to conventional tribological parameters, also information of temperature, stress and phase transformations in the femoral heads as received from the manufacturer. Raman and fluorescence spectra at the point of sliding contact are recorded durilng reciprocating hard-on-hard dry-sliding tests. Preliminary results were collected on two different commercially available ceramic-on-ceramic hip joint bearing couples, made of monolithic alumina and alumina-zirconia composites. Although the composite couple showed direct evidence of tetragonal-to-monoclinic phase transformation, which enhanced the coefficient of friction, the specific wear rate was significantly lower than that of the monolithic one (i.e., by a factor 2.63 and 4.48 on the pin and head side, respectively). In situ collected data compared to ex situ analyses elucidated the surface degradation processes and clarified the origin for the higher wear resistance of the composite as compared to the monolithic couple.

Collaboration


Dive into the Leonardo Puppulin's collaboration.

Top Co-Authors

Avatar

Giuseppe Pezzotti

Kyoto Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Wenliang Zhu

Kyoto Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kengo Yamamoto

Tokyo Medical University

View shared research outputs
Top Co-Authors

Avatar

Marco Boffelli

Kyoto Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge